• Title/Summary/Keyword: VOCs

Search Result 1,346, Processing Time 0.031 seconds

Characterization of Volatile Organic Compounds concentrations in the ambient air of the Kumi industrial complex (구미산업단지 대기중 휘발성유기화합물(VOCs)의 농도특성)

  • Choe, U Geon;Bae, Sang Ho;Park, Deok Sin;Jeong, Yeon Gu;Kim, Tae O
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.205-214
    • /
    • 2004
  • This study focuses on the measurement of airborne Volatile Organic Compounds (VOCs) in the Kumi electronic industrial complex during the time periods of August and September, 2002 and January and February, 2003. This study was based on the US-EPA method TO-14 while the VOCs were analyzed with GC/MSD. The toluene level revealed high concentration at all measurement sites. The areal rank of average concentrations of VOCs is as follows: industry1 > industry2 > urban > middle > residential. Concentrations of VOCs in Kumi electronic industrial ones were generally higher than at Yeochon and Ulsan industrial complexes. Dichloromethane and trichloroethylene, which are used as a cleaner in the process of electronic industries, were observed 4 to 8 times higher than those of other areas. Among the aromatic compounds, toluene showed the highest level, while the concentrations of dichloromethane and trichloroethylene were higher than those of other halogen compounds. In Kumi, toluene, trichloroethylene, and dichloromethane were confirmed as the major compounds of VOCs by this research.

Quality Control(QC) Analysis of Ambient VOCs in Canisters Using GC/MSD Method (Canister와 GC/MSD를 이용한 대기 중 VOCs 분석시스템의 정도관리(QC))

  • Jeon, Jun-Min;Hur, Dang;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.527-538
    • /
    • 2002
  • In this study, the performance of sampling and of analytical methodology was examined against a number of selected volatile organic compounds (VOCs) in the ambient air. The canister-based sampling method for VOCs has been a viable and widely used approach that is based on research and evaluation performed over the past several years. VOCs were determined using canisters by GCMSD analysis. A total of target analyses in this study included approximately 30 VOCs designated in TO-l4A categories including BTEX. The methodology for QC(quality control) was intensively investigated with a wide range of performance criteria such as; (1) cleanliness of canisters, (2) reproducibility of diluter, (3) instrumental detection limits of preconcentrator and GCMSD, and (4) precision and accuracy of GCMSD. For most of the compounds tested, precision was less than $\pm$5%, IDL was 0.2 ppbv, accuracy was $\pm$5%, respectively. This study demonstrated that the combination of canister sampling and GC/MSD analysis could be reliably applied to the measurements of BTEX in ppbv levels that are typically observed in/outdoor air environment.

A Study on the Distributions of VOC Concentrations in Shiwha Area (시화지구에서 발생되는 VOCs 농도분포 특성 연구)

  • Kim Jin-Yong;Lee Hyo-Song;Yu Jae-Keun;Kil In-Sub;Kim Duk-Hyun;Rhee Young-Woo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.6
    • /
    • pp.613-624
    • /
    • 2005
  • In this study, we investigated the characteristic of volatile organic compounds (VOCs) concentrations in Shiwha area, which were measured using the Open-path FTIR Gas Analyzer. The passive samplers were set for a certain period of time to obtain the average concentration of toluene, ethylbenzene, o-xylene and styrene. In addition, VOCs concentration contour maps were constructed using the Tecplot program to illustrate the VOCs concentration distribution. The residential area showed higher concentrations than the industrial area. And the summer had higher concentration value than the winter. Also, we confirmed that the VOCs concentrations ranged from 2 to several tens ppb in the vicinity of an industry than diffused VOC concentration, whereas those ranged from 0 to 5 ppb in most other areas. It was conferred that the wind change with seasons significantly affects the distribution of VOCs concentrations such as a northwesterly wind in the winter or a southwestern wind in the summer.

VOCs Reduction of Visible-light Responsive Photocatalyst coated nylon/polyester composite fiber for Vehicle Interior Parts and Materials (가시광 감응형 광촉매가 코팅처리된 자동차내장재용 Nylon/Polyester 복합섬유의 VOCs 저감)

  • Choi, Sei-Young
    • Elastomers and Composites
    • /
    • v.49 no.1
    • /
    • pp.53-58
    • /
    • 2014
  • In this study, characteristics of visible-light responsive photocatalyst Weltouch, especially VOCs reduction of visible-light responsive photocatalyst coated nylon/polyester composite fiber for vehicle interior parts and materials were evaluated. Visible-light responsive photocatalyst Weltouch was observed for both anatase phase and rutile phase. It is activated by light longer than 420nm. VOCs and formaldehyde generated from visible-light responsive photocatalyst treated nylon/polyester composite fiber were reduced confirmly. Visible-light responsive photocatalyst was firmly attached to the surface of nylon/polyester composite fiber without elimination even after 25 times repeated washing. And washing durability of nylon/polyester composite fiber confirmed the excellence that reduction effects of VOCs after repeated washing has appeared as much as before washing.

Removal of VOCs from Water by Vapor Permeation through PU/PDMS Membrane (PU/PDMS 막을 이용한 증기투과공정에 의한 물로부터 휘발성 유기화합물 제거)

  • 임지원;남상용;김영진;천세원
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.157-165
    • /
    • 2004
  • PU/PDMS(Poly urethane/poly(dimethylsiloxane ) membranes were prepared to enhance chemical resistance over VOCs from 4,4'-diphenylmethane diisocyanate (MDI), poly(dimethylsiloxane) (PDHS). Swelling characteristics and vapor permeation performance of toluene, 1,2-dichloroethane, hexane through PU/PDMS membrane with various feed VOCs concentration were investigated. Swelling ratio of VOCs showed tendency of Toluene > 1,2-dichloroethane > hexane. Fiux of toluene and 1,2-dichloroethane increased with increasing fled concentration while the flux of hexane maintained with increasing feed. VOCs concentration in permeate maintained 50 wt% oi concentration due to high affinity of PU/PDHS membranes to VOCs.

The Characteristic of Volatile Organic Compounds(VOCs) Emission from the Type of Indoor Building Materials as the Temperature and Humidity (온.습도에 따른 건축 내장재별 휘발성유기화합물의 방출특성)

  • Seo, Byeong-Ryang;Kim, Shin-Do;Park, Seong-Kyu
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.4 s.91
    • /
    • pp.292-303
    • /
    • 2006
  • The Volatile Organic Compounds(VOCs) are emitted from various sources and have lots of different form. Recently human are spending the many times at indoor area and indoor air pollution is issued the important social problem. The emission sources of indoor air pollutants are very various, also indoor building materials are composed of very complex chemical compounds, these indoor building materials discharge very much VOCs and other hazardous compounds. In this study, we performed the small chamber test to investigate the VOCs emission concentration and characteristics involving five kinds of the indoor building materials(furniture material, wooden floor, wall paper, paint and tile) under different conditions of four temperature and relative humidity as account of the air flow rate(AFR), air exchange rate(AER), loading factor and air velocity respectively. As the result, It was showed that building materials are emitted the highest VOCs concentration at the beginning of experiment and furniture material is emitted the highest VOCs concentration. Most of the materials were affected by temperature, but paint and tile material were affected by humidity.

The Characteristics of Biodegradation for VOCs in Unsaturated Soil by Bio-filter (Bio-filter에 의한 토양중의 VOCs 분해특성)

  • Sohn Jong-Ryeul;Jang Myung-Bae;Cho Kwang-Myung
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.4 s.54
    • /
    • pp.19-24
    • /
    • 2004
  • The objective of this study was to develop a mechanistically based mathematical model that would consider the interdependence of VOCs transport, microbial activity, and sorptive interactions in a moist, unsaturated soil. Because the focus of the model was on description of natural attenuation, the advective VOCs transport that is induced in engineered remediation processes such as vapor extraction was not considered. The utility of the model was assessed through its ability to describe experimental observations from diffusion experiments using toluene as a representative VOCs in well-defined soil columns that contained a toluene degrading bacterium, Pseudomonas putida G7 md Fl, as the sole active microbial species. The gas-liquid mass-transfer was found to be a key parameter controlling the ability of bacteria to degrade VOCs. This finding indicates that soil size and geometry are likely to be important parameters in assessing the possible success of natural attenuation of VOCs in contaminated unsaturated soils. Therefore we found that Pseudomonas putida G7 and Fl were very effective to remove of refractory pollutants such as toluene in soil by Bio-filter

VOCs Emission Characteristics and Mass Contribution Analysis at Wanju Industrial Area (완주지역의 VOCs 배출특성에 따른 공단지역과 일반지역의 기여도 분석)

  • Kim, Deug-Soo;Yang, Go-Soo;Park, Bi-O
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.5
    • /
    • pp.562-573
    • /
    • 2008
  • Concentrations of volatile organic compounds (VOCs) measured from the local industrial sources in Wanju industrial complex during June $2007{\sim}January$ 2008. The samples were collected from the primary sources (6 emission points) in 4 major factories in Wanju industrial complex as well as two general sources in Wanju County to elucidate the abundances of speciated VOCs and their spacial and temporal distributions depending on source bases. Industrial sources are as follows; fabricated metal manufacture, motor vehicle manufacture, rubber and plastic manufacture, and chemical manufacture factories. Two general source samples were collected from gasoline gas station and dry cleaning shop in urban area. In order to understand the near source influence at receptor, samples from the two receptor sites (one is at center of the industrial complex and the other site is at distance residential area downwind from the center) were collected with sample canister, and analyzed by using GC/MSD. The concentrations from different sources were compared and discussed. The mass contributions of the speciated VOCs to total VOCs measured from industrial sources and ambient ai r at two receptors were presented and discussed.

Photocatalytic Oxidation of Indoor Air Volatile Organic Compounds (VOCs) in pub Level

  • Jo, Wan-Kuen;Kim, Dong-Hyun;Ki, Jae-Chang;Huh, Jeung-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E4
    • /
    • pp.157-168
    • /
    • 2003
  • This study evaluated the technical feasibility of the application of titanium oxide (TiO$_2$) photocatalysis for the removal of VOCs in low ppb concentrations commonly associated with non -occupational indoor air quality issues. A series of experiments were conducted to evaluate four parameters (relative humidity (RH), hydraulic diameter (HD), photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) for the PCO destruction efficiencies of the selected target VOCs. None of the target VOCs presented significant dependency on the RH, which is inconsistent with a few previous studies. However, it is noted that the three parameters (HD, RM and IPS) should be considered for better VOCs removal efficiencies for the application of TiO$_2$ photocatalytic technology for cleansing non -occupational indoor air. The PCO destruction of VOCs at concentrations associated with non-occupational indoor air quality issues can be up to nearly 100%. The amount of CO generated during PCO would be negligible in comparison to the indoor CO levels. These results can make the PCO reactor an important tool in the effort to improve non-occupational indoor air quality.

Analysis of VOCs Produced from Incineration of Plastic Wastes Using a Small- Electric Furnace (소형전기로를 이용한 플라스틱류 소각시 발생하는 VOCs 농도분석)

  • Lee Byeong-Kyu;Kim Haengah
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.759-771
    • /
    • 2004
  • This study analyzed concentrations of volatile organic compounds (VOCs) produced from incineration of plastic wastes at $600^{\circ}C$. The plastic wastes used in this study included polyethyleneterephthlate (PETE), high density polyethylene (HOPE), polyvinyl chloride (PVC), low density polyethylene (LOPE), polypropylene (PP), polystyrene (PS) and other. Plastic wastes were heated from room temperature upto $600^{\circ}C$ providing the compressed air inside of a small-scale electric furnace for 90 minutes and then they were oxidized (incinerated) for 60 minutes at $600^{\circ}C$ maintaining the same air supply. VOCs emitted from the incineration process were sampled using an air sampling pump and Tedlar air bags for 150 minutes and then the components and concentrations of the VOCs were analyzed by a GC-MS. The most prominent chemical structure of the VOCs obtained from the incineration process of the HOPE, LOPE and PP, which include ethylene groups in their main chains, was identified as aliphatic hydrocarbons such as 1-hexene. However, aromatics such as benzene were major chemical structure from the incineration of PETE, PVC and PS which include benzene rings in their main chains. This study estimated the total VOC production from the incineration of the plastic wastes based on the real plastic waste production and the emission factors. 64% and 27% of the total VOC emissions consisted of aliphatic hydrocarbons and aromatics, respectively, which have double bonds within their molecular structure and thus a high ground level ozone formation potential.