• 제목/요약/키워드: VOCs

검색결과 1,348건 처리시간 0.03초

복합자재에서의 VOCs 방출량 예측에 관한 연구 (Prediction of VOCs Emissions from Multi-layers Materials)

  • 윤창현;권경우;박준석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.9-14
    • /
    • 2005
  • The purpose of this study is to predict VOCs emission rates from multi-layers materials, which are composed of single-layer materials having various VOCs emission rates, by using effective diffusion coefficients of the single-layer materials. The study was consisted of two parts; the one is the prediction of VOCs emission rates from multi-layer materials through numerical methods. The other is the measurement of VOCs emissions rates of wall composite and floor composite in Mock-up rooms for comparing the prediction and the experiments' values. The results of the study show that the short-term VOCs emission rates of multi-layers materials can be predicted from the effective diffusion coefficients of single materials in odor accuracy.

  • PDF

DAF(Dissolved Air Flotation)를 이용한 정수처리에서 처리조건에 따른 VOCs(Volatile Organic Compounds)의 처리효율에 대한 연구 (Removal Rates of VOCs(Volatile Organic Compounds) for Treatment Condition using DAF(Dissolved Air Flotation) in Water Treatment)

  • 김미정;전세진
    • 상하수도학회지
    • /
    • 제13권3호
    • /
    • pp.91-100
    • /
    • 1999
  • Treatment conditions of DAF(Dissolved Air Flotation) and removal rates of VOCs(Volatile Organic Compounds) in mixed water of H raw water and VOCs were investigated. The used VOCs were benzene, toluene, ethylbenzene, and xylene in aromatic compounds and iso propyl mereaptan, n-butyl mereaptan, dimethyl disulfide, and iso butyl mercaptan in odors. The related parameters include water type, treatment method, clay concentration, pH condition, flocculation time, flotation time, per-cent recycle, water temperature, pressure. The removal rates of VOCs were different on treatment process and water condition. Treatment time was longer, removal rates of VOCs was higher. Water temperature was more important than pressure in DAF parameters. Molecular weight was related with removal rate in several kinds of VOCs were decraesed by competition of each component in II raw water. When algac blooming D water was treated by DAF, TCOD(Total chemical Oxygen Demand) and chorophyll a was removed over 96%.

  • PDF

광양만 해수의 휘발성 유기화합물에 대한 시.공간적 분포 (Temporal and Spatial Distribution of VOCs in Seawater of Kwangyang Bay)

  • 주현수;이우범;박종천
    • 환경생물
    • /
    • 제17권4호
    • /
    • pp.513-519
    • /
    • 1999
  • 광양만 해수를 대상으로 총 17개의 조사정점을 선정, 1996년 7월부터 1997년 4월까지 계절별로 19종류의 VOCs를 분석.조사하였다. 조사대상 VOCs 중 methylene chloride, tetrachloromethane, 1, 1, 1-trichloroethane, trichloroethane, 1, 1, 1, 2-tetrachloroethane, trichloroethylene, bromoethane, dibromoethane, bromobenzene, 1-ethyl-3-methylbenzene등 총 10개 항목은 전체 조사지점 및 조사 시기 동안에 검출되지 않았으며, chloroform, 1, 2-dichloroethane, ethylbenzene, benzene, toluene, m, p-xylene, methylethylketone, styrene, hexane 등의 조사항목은 소량의 범위에서 조사시기와 정점을 달리하여 검출되었다. 특히 chloroform과 toluene은 0.6~49.9$\mu$g/1, 0.42~48.3$\mu$g/1로서 높은 농도의 범위를 나타내었으며, 검출빈도도 다른 조사 대상 VOCs에 비해 높은 것으로 조사되었다. 이화학적 환경요인과 VOCs와의 상관관계에서 toluene만이 수온(r=-0.524), pH(r=0.319)가 비교적 높은 상관성을 보였으며 나머지 항목은 매우 낮은 상관성을 보였다. VOCs 상호간의 상관성에서 benzene의 경우 toluene, m, p-xylene, ethylbenzene과 높은 상관계수(r=0.549~0.662)를 보였다. 이러한 결과는 광양만에서 VOCs의 배출이 같은 시기에 이루어지고 있음을 시사하는 것으로 추측된다.

  • PDF

실내외 공기중 휘발성 유기화학물질(VOCs)의 농도조사에 관한 연구 (Measurements of Indoor and Outdoor Volatile Organic Compounds(VOCs) Concentrations in Ambient Air)

  • 신혜수;김윤신;허귀석
    • 한국대기환경학회지
    • /
    • 제9권4호
    • /
    • pp.310-319
    • /
    • 1993
  • A pilot study was conducted in order to investigate the concentrations of indoor and outdoor VOCs (Volatile Organic Compounds) at ten homes and four building offices in Seoul during March-April, 1993. The five components of VOCs(Benzene, Toluene, Ethylbenzene, o-Xylene, m/p-Xylene) were collected using charcoal tube and were analysed using Gas Chromatography(GC) with a Flame Ionization Detector(FID). The mean concentations of indoor VOCs were shown as Benzene of 38.9 .mu.g/m$^{3}$. Toluene of 165.0 .mu.g/m$^{3}$, Ethylbenzene of 21.7 .mu.g/m$^{3}$, o-Xylene of 11.6 .mu.g/m$^{3}$ and m/p-Xylene of 29.3 .mu.g/m$^{3}$, but those corresponding that indoor levels of VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs were higher than corresponding outdoor levels. The ratio of indoor and outdoor VOCs concentrations was 0.99 for Benzene, 1.23 for Toluene, 5.86 for Ethylbenzene, 5.23 for o-Xylene, 2.41 for m/p-Xylene in homes, while 2.02 for Benzene, 1.15 for Toulene, 0.96 for Ethylbenzene, 1.41 for o-Xylene, 1.38 for m/p-Xylene in offices, respectively. The mean concentrations of VOCs in homes were higher than those levels in offices, while the mean concentration of VOCs during active hour of occupants in a day were higher 1-3 times than the levels during non-active hour. Comparing VOCs levels by building's age, the mean concentrations of Benzene, o-Xylene and m/p-Xylene were higher in new building than old building, but the mean concentrations of Toluene and Etylbenzene in new building were lower than old building. The mean concentrations in all components of VOCs in smoking area were higher than non-smoking area. These results suggested that the VOC levels were affected by various indoor characteristics and behavioral activity of occupants.

  • PDF

토양 흡착에 대한 유기탄소와 온도의 영향 (Influence of Organic Matter and Temperature on the Sorption of Volatile Organic Compounds on Soil)

  • 김희경
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.57-59
    • /
    • 1998
  • The headspace method has been acknowledged as a cost-effective and convenient method to analyze volatile organic compounds(VOCs) in soil. The headspace analysis is based on equilibrium partitioning of VOCs among water, air and soil in a closed system. However, the headspace method cannot be applied to soils where most of the VOCs remain sorbed even at high temperature. In this study, it was investigated how the sorption characteristics of VOCs varied with soil with different organic carbon contents and temperature. This study showed that all the VOCs were volatilized, not sorved, only in the soil with 5% organic carbon at 45$^{\circ}C$ or higher. Some fraction of VOCs remained in soil with 8% organic carbon at $65^{\circ}C$ of higher. Most of the VOCs remained sorbed in soil with 12% organic content even at 95$^{\circ}C$. This result suggested that the headspace method can be applied only to soils with little organic carbon content (less than 5%). In this case, 45$^{\circ}C$ seems to be high enough to volatilize all the VOCs from soil. Large particles still showed a significant sorption capacity for VOCs from soil. Large Particles still showed a significant sorption capacity for VOCs despite of their low level of organic carbon content. It was also shown that the organic carbon sorption coefficients (Koc) of VOCs varied with soils with different organic carbon content. This suggests that not only the organic matter content of soil but also the property of the organic matter in soil influence the sorption of VOCs to soil.

  • PDF

하계 실내 및 실외환경의 공기 중 휘발성 유기화합물 농도 및 개인노출 (Volatile Organic Compounds Concentrations and Its Personal Exposure in Indoor and Outdoor Environments in Summer)

  • 양원호;손부순;박종안;장봉기;박완모;김윤신;어수미;윤중섭;류인철
    • 한국환경과학회지
    • /
    • 제12권9호
    • /
    • pp.967-976
    • /
    • 2003
  • Volatile organic compounds (VOCs) are present in essentially all natural and synthetic materials from petrol to flowers. In this study, indoor and outdoor VOCs concentrations of houses, offices and internet-cafes were measured and compared simultaneously with personal exposures of each 50 participants in Asan and Seoul, respectively. Also, factors that influence personal VOCs exposure were statistically analyzed using questionnaires in relation to house characteristics, time activities, and health effects. All VOCs concentrations were measured by OVM passive samplers (3M) and analyzed with GC/MS. Target pollutants among VOCs were Toluene, o-Xylene, m/p-Xylene, Ethylbenzene, MIBK, n-Octane, Styrene, Trichloroethylene, and 1,2-Dichlorobenzene. Indoor and outdoor VOCs concentrations measured in Seoul were significantly higher than those in Asan except Ethylbenzene. Residential indoor/outdoor (I/O) ratios for all target compounds ranged from 0.94 to 1.51 and I/O ratios of Asan were a little higher than those of Seoul. Relationship between personal VOCs exposure, and indoor and outdoor VOCs concentrations suggested that time-activity pattern could affect the high exposure to air pollutant. Factors that influence indoor VOCs level and personal exposure with regard to house characteristics in houses were building age, inside smoking and house type. In addition insecticide and cosmetics interestingly affected the VOCs personal exposure. Higher exposure to VOCs might be caused to be exciting increase and memory reduction, considering the relationship between measured VOCs concentrations and questionnaire (p<0.05).

낙동강 유역 일부 폐수처리장 방류수 및 공단배수로의 휘발성유기화합물(VOCs)의 분포현황 (The Detection of VOCs in Effluents from Several Wastewater Treatment Plants and Industry Drains in Nakdong River Basin)

  • 배헌균
    • 대한환경공학회지
    • /
    • 제34권4호
    • /
    • pp.254-259
    • /
    • 2012
  • 낙동강 유역 일부공단지역에 위치한 일곱 개소의 폐수처리장 및 두 개소의 공단배수로에서 휘발성유기화합물(Volatile Organic Compounds, VOCs)의 분포특성을 조사하였다. 시료는 2008년 5월부터 2008년 11월 사이 총 4회에 걸쳐 채취하였으며 총 17종의 VOCs를 분석하였다. 실험 결과, 8종의 VOCs가 일부 시료에서 검출이 되었고 검출농도는 종류와 시료채취 위치에 따라 달랐지만 모두 0.11 (Trichloroethylene)~5.81 (Toluene) ${\mu}g/L$ 의 범위인 것으로 확인되었다. VOCs는 미량으로도 인간의 건강이나 수중 생태계에 심각한 영향을 미칠 수 있으므로 이들 물질이 비록 미량의 수준을 보였으나 검출이 된 이상 이들 물질에 대한 적절한 관리대책이 강구되어야 할 것으로 사료되며 본 연구에서 이들 물질에 대한 관리방안을 제안하였다.

PCA와 ANN을 이용한 VOC 측정기기 개발 (The Development of VOC Measurement System Uging PCA & ANN)

  • 이장훈;권혁구;박승호;김동진;홍철호
    • Environmental Analysis Health and Toxicology
    • /
    • 제19권2호
    • /
    • pp.161-167
    • /
    • 2004
  • Air quality monitoring is a primary activity for industrial and social environment. The government identifies the pollutants that each industry must monitor. Especially, the VOCs (Volatile Organic Compounds), which are very harmful to human body and environment atmosphere, should be controlled under the government policy. However, the VOCs, which have not been confirmed in emission sources are very difficult to monitor. It is needed to develop the monitoring system that allow the continuous and in situ measurement of VOCs mixture in different environmental matrices. Gas chromatography and mass spectrometry are the most prevalent current techniques among those available for the analysis of VOCs. But, they need a large size analytical instrument, which costs a great deal for purchase and operation. In addition, it has some limitations for realtime environmental monitoring such as location problems and slow processing time. Recently, several companies have commercialized a portable VOCs measurement systems, which cannot classify various kinds of VOCs but total quantities. We have developed a VOCs measurement system, which recognizes various kinds and quantities of VOCs, such as benzene, toluene, and xylene (BTX). Also, it can be used as a stand- alone type and/or fixed type in the vehicle with rack for real -time environmental monitoring.

카페트에서 방출되는 VOCs의 방출특성 (Emission Characteristics of Volatile Organic Compounds (VOCs) from a Carpet)

  • 신동민;김창녕;김동술
    • 설비공학논문집
    • /
    • 제15권1호
    • /
    • pp.40-49
    • /
    • 2003
  • This study has been conducted to identify and quantify the emissions of Volatile Organic Compounds (VOCs) from a new carpet. The carpet sample consists of polypropylene cushion and latex backing. The VOCs have been sampled on sorbent tubes and analyzed by thermal desorption unit and GC/MSD. For over 240 hours, concentration of VOCs has been measured in a small chamber made of stainless steel. With the measured data, emission factor and mass balance have been considered. The experiments have been conducted in accordance with ASTM D5116-97. The carpet has emitted a variety of VOCs, but in this study, 7 VOCs compounds have been considered: chlorobenzene, ethylbenzene, styrene, isopropylbenzene, bromobenzene, 2-chlorotoluene, and 1,2,3-trimethylbenzene. The results show that the concentrations of VOCs and the emission factors have exponentially decayed from relatively high level to low level with time. The gradients of the concentration of VOCs and emission factors are different for various components. It is found that styrene, 2-chlorotoluene are emitted more than others with higher concentrations.

Determination of Volatile Organic Compounds (VOCs) Using Tedlar Bag/Solid-phase Microextraction/Gas Chromatography/Mass Spectrometry (SPME/GC/MS) in Ambient and Workplace Air

  • Lee, Jae-Hwan;Hwang, Seung-Man;Lee, Dai-Woon;Heo, Gwi-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권3호
    • /
    • pp.488-496
    • /
    • 2002
  • SPME techniques have proven to be very useful tools in the analysis of wide VOCs in the air. In this study, we estimated VOCs in ambient and workplace air using a Tedlar ba /SPME/GC/MS system. The calibration curve was set to be linear over the range of 1-30 ppbv. The detection limits ranged from 10 pptv to 0.93 ppbv for all VOCs. Reproducibility of TO-14 target gas mixtures by SPME/GC/MS averaged at 8.8 R.S.D (%). Air toxic VOCs (hazardous air pollutants, HAPs) containing a total of forty halohydrocarbons, aromatics, and haloaro-matic carbons could be analyzed with significant accuracy, detection limit and linearity at low ppbv level. Only reactive VOCs with low molecular weight, such as chloromethane, vinylchloride, ethylchloride and 1,2-dichloro-ethane, yielded relatively poor results using this technique. In ambient air samples, ten VOCs were identified and quantified after external calibration. VOC concentration in ambient and workplace air ranged from 0.04 to 1.85 ppbv. The overall process was successfully applied to identify and quantify VOCs in ambient/workplace air.