• 제목/요약/키워드: VOCs(Volatile Organic Compounds)

검색결과 686건 처리시간 0.028초

기존 공동주택의 실내 유해화학물질 오염발생원에 대한 특성 분석 (An Analysis on Characteristics of the Pollutants and the Real Condition State of the Indoor Air Pollution in Occupied Apartment Units)

  • 유복희
    • 한국주거학회논문집
    • /
    • 제21권6호
    • /
    • pp.11-18
    • /
    • 2010
  • The aims of this study were to grasp the real condition state and clarify the characteristics and influence of pollutants on the indoor air pollution in occupied apartment units. The research method was to measure the pollution levels of indoor air pollution, and investigate characteristics of the pollutants such as the outdoor environment, elapsed time after construction, finished materials, temperature, relative humidity, space extension, purchase with furniture and electric appliances, built-in closets, and method for cleaning the air. And these were made a comparition between industrial and residential area. The VOCs and formaldehyde concentration in indoor air were measured the 6 household in residental area and 5 household in industrial area. In conclusion, the concentration such as benzene, ethylbenzene, toluene, xylene, styrene showed the pollution state within permissible levels, however formaldehyde concentration has need a lot of attention as ever. And it turned out that the influence with reference to emission from building materials on indoor air pollution lessened under 18 months elapsed time after construction.

백화점 내 업종별 판매매장에 따른 오염물질 배출현황 평가 (Evaluation of Pollutants Emissions according to the Selling Store in Department Store)

  • 왕형석;황준석;장성진;김수민
    • 한국가구학회지
    • /
    • 제26권1호
    • /
    • pp.71-76
    • /
    • 2015
  • It is important thing that air quality affects human health. And It is more important thing that Indoor Air Quality more affects human health than Outdoor Air Quality. The cause of that is indoor air pollutants are more absorbed than outdoor air pollutants. By the way, in case of Multi-use facility for example office, department store, school etc., it has a feature that there are more people than any other buildings. therethrough, effects of Indoor Air Quality of Multi-use facility affect more people's health than Indoor Air Quality of any other buildings. However, in multi-use facility, specifically retail store, chemical treated materials are used for interior finishing, showcase finishing and product finishing because esthetic element is more added for detention of customer. Consequently, in place where demands brisk sales, possibility that indoor air is polluted by VOCs is high. This study considered retail store's Indoor Air Quality. as result of experiment, figure of department store's air pollution exceed about 5~20 times in guideline of multi-use facility's Indoor Air Quality in any kind of shop of department store (guideline : $500{\mu}g/m^3$).

연직배수재를 이용한 토양증기추출법의 적용 (Application of Enhanced Soil Vapor Extraction Using PVDs)

  • 신은철;박정준;김종인;최민근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 지반공학 공동 학술발표회
    • /
    • pp.382-388
    • /
    • 2005
  • Soil vapor extraction(SVE) is an effective and cost efficient method of removing volatile organic compounds(VOCs) and petroleum hydrocarbons from unsaturated soils. However, soil vapor extraction becomes ineffective in soils with low gas permeability, for example soils with air permeabilities less than 1 Darcy. Prefabricated vertical drains(PVDs) have been used for dewatering fine-grained soils for more than 25 years. Incorporating PVDs in and SVE system can extend the effectiveness of SVE to lower permeability soils by shortening the air flow-paths and ultimately expediting contaminant removal. The objective of the work described herein was to effectively incorporate PVDs into a SVE remediation system and to demonstrate a PVDs enhanced SVE system at full scale. The finding from this research will facilitate the design of field PVD-SVE systems in terms by providing insight into the optimal spacing between PVDs, the radius of influence of the wells and the flow rates to be used to capture and extract gas phase contaminants.

  • PDF

서브 피피엠 레벨 미세기전 가스 센서 (Sub-ppm level MEMS gas sensor)

  • 고상춘;전치훈;송현우;박선희
    • 센서학회지
    • /
    • 제17권3호
    • /
    • pp.183-187
    • /
    • 2008
  • A sub-ppm level MEMS gas sensor that can be used for the detection of formaldehyde (HCHO) is presented. It is realized by using a zinc oxide (ZnO) thin-film material with a Ni-seed layer as a sensing material and by bulk micromachining technology. To enhance sensitivity of the MEMS gas sensor with Ni-seed layer was embedded with ZnO sensing material and sensing electrodes. As experimental results, the changed sensor resistance ratio for HCHO gas was 9.65 % for 10 ppb, 18.06 % for 100 ppb, and 35.7 % for 1 ppm, respectively. In addition, the minimum detection level of the fabricated MEMS gas sensor was 10 ppb for the HCHO gas. And the measured output voltage was about 0.94 V for 10 ppb HCHO gas concentration. The noise level of the fabricated MEMS gas sensor was about 50 mV. The response and recovery times were 3 and 5 min, respectively. The consumption power of the Pt micro-heater under sensor testing was 184 mW and its operating temperature was $400^{\circ}C$.

Glidarc 워터젯 플라즈마를 이용한 톨루엔 분해 특성 (Decomposition Characterist of Toluene Using a Glidarc Water-jet Plasma)

  • 김성천;전영남
    • 한국대기환경학회지
    • /
    • 제24권3호
    • /
    • pp.329-335
    • /
    • 2008
  • Volatile organic compounds emitted to the atmosphere can cause adverse effects on human health and participate in photochemical smog formation reactions. The destruction of a series of VOCs has been carried out by non-thermal plasma in other researches. And the characteristic of non-thermal plasma was operated at atmospheric pressure and low temperature. A new type non-thermal plasma reactor was investigated combined Glidarc plasma with water jet in this research. Also, it was found that the water-jet had an significant effect on the toluene removal efficiency. But too much water content does not favor toluene decomposition by decreasing of reaction temperature. The input toluene concentration, gas flow rate, water flow rate and specific energy input were used as experiment variables. The toluene removal efficiency, energy efficiency and specific energy input were 75.3%, 146.6 g/kWh and $1.12kWh/m^3$ at a water flow rate of 100 mL/min.

가을철 도심지역 학교교사의 실내환경 측정연구 (Measurement of Classroom Air Quality in large cities in autumn)

  • 김윤덕;서동연
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.37-42
    • /
    • 2010
  • Together with the concern about the indoor air quality as sick house syndrome, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. The law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. School also have its own indoor air quality guideline. Indoor air quality in school is very important because, children who very weak to indoor pollutants reside long time in there. The purpose of this paper is to to survey indoor air quality in school by field measurement. Field measurements were performed in 11 schools which were selected from 3 major cities(Incheon, Dae-jeon, chuncheon) in korea, Totally concentration of indoor pollutants were determined in 32 classroom. Target air pollutants were TVOC, formaldehyde, dust, CO, CO2. For the result of this investigation, Indoor air quality in classroom was very poor and it was found that some pollutants(TVOC, float bacteria) exceed the guideline.

목욕시 Chloroform에 대한 흡기 및 피부 접촉 노출 (Inhalation and Dermal Exposures to Chloroform while Bathing)

  • 조완근
    • 한국환경과학회지
    • /
    • 제7권3호
    • /
    • pp.301-310
    • /
    • 1998
  • Recently, bathes have been suspected to an Important source of indoor exposure to volatile organic compounds(VOCs). Two experiments were conducted to evaluate chloroform exposure and corresponding body burden by exposure routes while bathing. Another experiment was conducted to ekamine the chloro- form dose during dermal exposure and the chloroform decay In breath after dermal exposure. The chioroform dose was determined based on exhaled breath analysis. The ekamine breath concentration measured after normal baths (2.8 Vg/$m^3$) was approxidmately 13 tomes higher that measured prior to normal bathes (0.2 ug/$m^3$). Based on the means of the normalized post exposure chloroform breath concentration. the dermal exposure was estimated to contribute to 74% of total chloroform body burden while bathing. The Internal dose from bathing (Inhalation plus dermal) was comparable to the dose ostimated Srom dally water Ingestion. The rusk associated 10 a weekly, 30-min bath was estimated to be 1 x 10.5, while the rusk firom dally Ingestion of tap water was to be $0.5{\times}0^{-5} for 0.151 and 6.5{\times}10^{-5}$ for 2. 0 1. Chloroform breath concentration Increased gradually during the 60 minute dermal exposure. The breath decay after the dermal exposure showed two-phase mechanism, with early raped decay and the second slow decay. The mathematical model was developed to describe the relationship between water and air chloroform concentrations, with $R^2$ : 0.4 and p<0.02.

  • PDF

실내용 공기청정기 유형별 실내환경개선 성능에 대한 비교평가 (Comparative Efficiency Evaluation of Air Cleaners for Improving Indoor Air Quality)

  • 나경호;손진석;성기준;장영기
    • 환경영향평가
    • /
    • 제14권3호
    • /
    • pp.109-115
    • /
    • 2005
  • This study was conducted to evaluate the efficiency of indoor air cleaners and to inform how to select them correctly to the users. The efficiencies of removing suspended bacteria per hour were $64.3{\pm}13.1%$ for filter, wet, and complex type, respectively, which showed the complex type was the most efficient. The removal efficiencies of formaldehyde (HCHO) after two hours operation of air cleaners showed 88.3% and 81.1% for filter and wet type, respectively. The efficiency of complex type, with removal rate of 55.5~58.4%, was decreased after 30 minutes operation. Therefore, it is recommended to perform over 60 minutes when doing air cleaner certification test for HCHO removal efficiency. Generally, air cleaners having low wind volume showed higher efficiency. All tested air cleaners had no potential for removing of volatile organic compounds (VOCs), which is toxic substances, and it is desirable to develop a device which can control these substances. The results also confirmed that there was no ozone production from all tested air cleaners. And it is recommended to ventilate for 20 minutes every four hours to maintain 50% ventilation status.

입자 크기에 따른 ITO 후막 센서의 가스 감지 특성 (Gas Sensing Properties of Nanocrystalline ITO Thick Films with Different Particle Sizes)

  • 신동원;이상태;전희권;이덕동;임정옥;허증수
    • 한국재료학회지
    • /
    • 제13권2호
    • /
    • pp.106-110
    • /
    • 2003
  • Nano-sized powders of Indium Tin Oxide(ITO) were synthesized by a coprecipitation method. In order to investigate the gas sensing characteristics in the nanocrystalline ITO thick films with various particle sizes, ITO powders with the average particle diameter of 15, 30, and 70 nm respectively were synthesized. And the sensitivity of ITO thick films was measured upon exposure to a target gas($C_2$$H_{5}$ /OH) and some other Volatile Organic Compounds(VOCs), such as, toluene, methanol, benzene, chloroform. As a result, ITO thick films had high sensitivity for ethanol and higher sensitivity with smaller particle size.

여름철 대도심 학교교실의 실내공기환경 측정연구 (Measurement of Classroom Air Quality in large cities in summer)

  • 김윤덕
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.63-74
    • /
    • 2007
  • Together with the concern about the indoor all quality as sick house syndrome, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. In Dec 2005, the law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. School also have its own indoor air quality guideline, Indoor air quality in school is very important because, children who very weak to indoor pollutants reside long time in there. The purpose of this paper is to survey indoor air qualify in school by field measurement. Field measurements were performed in 11 schools which were selected from 3 major cities(Incheon, Dae-jeon, chuncheon) in korea, during July, 2004. Totally concentration of Indoor pollutants were determined in 27 classroom. Target air pollutants were TVOC, formaldehyde, dust, CO, CO2 and NO2. For the result of this investigation, Indoor air quality in classroom was very poor and it was found that some pollutants (TVOC, float bacteria) exceed the guideline.