• Title/Summary/Keyword: VOCs(Volatile Organic Compounds)

Search Result 686, Processing Time 0.027 seconds

Effect of IgY on Periodontitis and Halitosis Induced by Fusobacterium nucleatum

  • Wang, Fang;Qiao, Wu;Bao, Bin;Wang, Shujun;Regenstein, Joe Mac;Shi, Yilei;Wu, Wenhui;Ma, Ming
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.2
    • /
    • pp.311-320
    • /
    • 2019
  • Fusobacterium nucleatum is a morbific agent in periodontitis and halitosis. Egg yolk antibody (IgY) was obtained from egg yolks from chickens stimulated with F. nucleatum. This study was to assess the effectiveness of IgY on periodontitis and halitosis caused by F. nucleatum in vitro and in vivo. The growth of F. nucleatum was inhibited (p <0.05) by different concentrations of IgY in vitro and the results of a Halimeter show volatile sulfur compounds (VSCs) were reduced to $904{\pm}57ppb$ at a concentration 40 mg/ml of IgY. The changes of fatty acids of F. nucleatum were determined using GC-MS. The scores for odor index of rat saliva were decreased. The major constituent of volatile organic compounds (VOCs) including short-chain acids decreased 46.2% in 10 mg/ml IgY, ammonia decreased 70% in 40 mg/ml IgY, while aldehydes and olefine ketones were almost unchanged. The ELISA assay revealed that IL-6 and TNF-${\alpha}$ were decreased after 4 weeks' IgY treatment. Morphometric (X-ray) and histological analyses (HE) showed that IgY reduced alveolar bone loss and collagen fibers became orderly in rat models. As a result, IgY may have the potential to treat periodontitis and halitosis.

Concentration of volatile organic compounds(VOCs) in ambient air and level of residents in industrial area (산단지역 공기 중 휘발성유기화합물농도와 지역주민의 노출 수준)

  • Woo, Kyungsook;Park, Heejin;Kang, Tackshin;Kim, Geunbae;Jeon, Junmin;Jang, Bongki;Lee, Jongwha;Son, Busoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.104-114
    • /
    • 2015
  • Objectives: The purpose of this study is to investigate the atmospheric concentration of VOCs and the urinary concentration of t,t-MA, HA, MA in the industrial complex of Yeosu, South Jeolla Province. Methods: In order to study seasonal patterns of air concentration of VOCs, measurements were taken at five sampling sites around Yeosu from June 2013 to June 2014. Urinary metabolite excretionsfrom 671 subjects, exposure and comparison area were analyzed. Results: The average concentration of VOCs in the air was 1.53ppb for benzene, 0.73ppb for toluene, 0.22ppb for ethylbenzene, 0.52ppb for xylene and 0.12ppb for styrene. The concentration of benzene was somewhat higher than the year-average standard ($5{\mu}g/m^3$, about 1.5ppb) of the domestic air-environment criteria newly established in 2010.The metabolic concentration of VOCs in the urine of the entire sample was analyzed at $47.76{\mu}g/g\;cr.$, 213.07mg/g cr., and $290.09{\mu}g/g\;cr.$ for t,t-MA, HA, and MA, respectively. Compared with the average values for Korea as presented in the first basic survey of national environmental conservation ( $49.8{\mu}g/g\;cr.$ for t,t-MA, 0.17g/g cr. for HA, and 0.26mg/g cr. for MA), the metabolic concentrations of HA and MA in urine were higher than the average values. Conclusions: The concentration of VOCs in the air and urinary metabolites of the exposed and control areas showed that the concentrations of all substances were higher in the exposed area than in the control area.

Critical Evaluation of and Suggestions for the VOCs Measurement Method Established as the Korean Indoor Air Quality Standard Method (실내공기질 공정시험법 중 VOCs 측정방법의 문제점 고찰 및 개선방안에 관한 연구)

  • Ye, Jin;Jung, Dong-Hee;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.586-599
    • /
    • 2014
  • During the last two decades, indoor air quality and volatile organic compounds (VOCs) have been of concern in Korean society due to their nature of potential health impacts. In order to investigate the pollution levels of VOCss in indoor environments, establishment of a solid test method for monitoring the airborne VOCss is essential. In Korea, a method based on adsorbent sampling and GC analysis coupled with thermal desorption was proclaimed as the Korea Standard Method for Indoor Air Quality Test. This study was carried out to examine some inherent problems of the VOCs measurement method. The VOCs method does not describe in detail preparing the standard samples. The standard samples may be prepared by impregnation of either liquid standard solutions or a mixture of standard gases. In this study, we investigated the optimal temperature condition for transferring the liquid standards onto a standard adsorbent tube. As a result, keeping the impregnation temperature at $250^{\circ}C$ will be recommended in regard of the boiling points of multiple target analytes and the thermal stability of the adsorbent. We also demonstrated some problems associated with handling of a syringe used for transferring the standard solutions onto the adsorbent tubes, and a best way to get rid of the syringe problems was suggested. Finally, a number of field works were conducted to evaluate the performance of adsorbent sampling methods. Comparison of different adsorbent tubes, i.e. tube packed with single sorbent (Tenax) and double sorbents (Tenax with Carbotrap), revealed that 30 to 40% differences between the two groups, implying that sampling efficiency is depending on the volatility and the strength of adsorbents. However, duplicate precisions for VOCs sampling with a same type of adsorbent and at same flow rates appeared to be satisfactory to be all within 20%, which is a quality control guideline. Distributed volume precisions were also found to be within a guideline value, 25%, although the precision was in general inferior to the duplicate precision. The Korea indoor VOCs test method should be more refined and improved in many aspects, particularly procedure and instrumentation for preparing the standard samples and specification of quality control assessment.

Catalytic Oxidation of Volatile Organic Compounds Over Spent Three-Way Catalysts (배기가스 정화용 폐 자동차 촉매를 이용한 휘발성 유기화합물의 제거)

  • Shim, Wang Geun;Kim, Sang Chai
    • Applied Chemistry for Engineering
    • /
    • v.19 no.5
    • /
    • pp.574-581
    • /
    • 2008
  • The optimum regeneration conditions for the regeneration of three way spent catalysts (TWCs), which were taken from automobiles with different driving conditions, were investigated to evaluate the suitability as alternative catalysts for removing VOCs. The spent catalysts were washed with five different acids ($HNO_3$, $H_2SO_4$, $C_2H_2O_4$, $C_6H_8O_7$, and $H_3PO_4$) to remove contaminants and examine the optimum conditions for recovering the catalytic activity. The physicochemical properties of spent and its regenerated TWCs were evaluated by using nitrogen adsorption-desorption isotherms, XRD, and ICP. The relative atomic ratios of contaminants and platinum group metals (PGMs) of the spent TWCs were greatly dependent on the placed positions. The main contaminants formed were lubricant oil additives and metallic components. Also, the regeneration treatment increased the PGMs ratio, BET surface area, and average pore diameter of TWCs. The catalytic activity results indicated that the spent TWCs have the possibility for removing VOCs. Moreover, the employed acid treatments greatly enhanced the catalytic activity of the spent TWCs. Especially, nitric and oxalic acids provided the most improvement in the catalytic behavior. The catalytic activities of the regenerated TWCs were significantly influenced by the containing platinum ratios rather than the removal ratios of contaminants and the changes in the structural properties offered by the acid treatments.

Removal/Recovery of VOCs Using a Rubbery Polymeric Membrane (Rubbery 고분가 막을 이용한 휘발성 유기화학물의 제거 및 회수)

  • Cha, Jun-Seok
    • Membrane Journal
    • /
    • v.6 no.3
    • /
    • pp.173-181
    • /
    • 1996
  • Common volatile organic compounds(VOCs) such as toluene and methanol were removed successfully from N$_{2}$ using a novel silicone-coated hollow fiber membrane module. This novel membrane is a thin film composite(TFC) and was highly efficient in removing VOCs selectively from a N$_{2}$ stream. This membrane had some innate advantages over other silicone-based membrane in that the selective barrier was ultrathin(~1 $\mu$m) and the porosity of the polypropylene substrate was high which leads to a low permeation resistance. The substram was very strongly bonded to the coating layer by plasma polymerization and can withstand a very high pressure. A small hollow fiber module having a length of 25cm and 50 fibers could remove 96~99% of toluene as well as methanol vapors when the feed flow rate was up to 60cc/min. The percent removal of VOCs were even higher when the feed inlet concentration was higher. This process is especially suitable for treating streams having a low flow rate and high VOCs concentration. The permeances of VOCs through this membrane was in the range of $4~30 \times 10^{-9}gmol/sec \cdot cm^{2}\cdot cmHg$ for both toluene and methanol, and nitrogen permeance was between $3~9 \times 10^{-10}gmol/sec \cdot cm^{2} \cdot cmHg$. High separation factor between 10~55 for toluene/N$_{2}$ and 15~125 for methanol/N$_{2}$ were obtained depending on the feed flow rate ranges and feed VOCs concentration levels.

  • PDF

A Study on the Emission of VOCs in Parking Lot Floor Coating (주차장 바닥 코팅제의 휘발성유기화합물 배출에 관한 연구)

  • Lee, Seung-Chan;Yoon, Gil-Ho;Park, Yong-Soon;Kil, Bae-Su;Yoon, Hyun-Do
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.152-158
    • /
    • 2019
  • Measure the type and content of VOCs for A-company epoxy coating and B-company floor coating(Type A, B), which are used as flooring materials for parking lots. Than the VOCs used gas detectors to measure gas emissions, assuming the worst environment to reduce errors in external environments in the formaldehyde, toluene and xylene harmful to workers and tenants. As a result, A-company epoxy coating has the largest amount of VOCs, and compared to A-company epoxy coating, B-company floor coating of A type represented about 79% less and B type about 96% less. In addition, A-company epoxy coating was also the highest in gas emission measurement for formaldehyde, toluene and xylene using gas detector after 1 hour and 8 hours in closed environment conditions. B-company floor coating A type was less than A-company epoxy coating, which was about 42.3% less measured. And type B satisfied all TWA even in closed environment conditions.

Biofiltration of Odorous Compounds in Municipal Solid Waste Landfill Gases (생물탈취상에 의한 도시폐기물 매립지가스내 악취물질의 처리)

  • 남궁완;박준석;황의영;이노섭;인병훈;김정대
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.1
    • /
    • pp.85-96
    • /
    • 1999
  • Biofiltration is an attractive technique for elimination of VOCs and odorous compounds from low-concentration, high-volume waste gas streams because of its simplicity and cost-effectiveness. The objective of this study was to estimate the removal characteristics of Odorous Compounds including $H_2$S, $NH_3$End BTEX in MSW landfill gases. This Study was conducted at Nanjido landfill site. A compost from the Nanjido composting facility was used as a filling material for biofiltration. Extracted landfill gases were injected into biofilter reactors after mixing with air. Experiments were performed in an incubator being set to $20^{\circ}C$ $H_2$S concentrations were monitored at the depths of 25, 50, 75 and 100cm from the bottom Of the biofilter reactors. 98% of $H_2$S was removed at the filling depth of only 25cm. NH$_3$removal rate was about 85%. Toluene removal rate was the highest among BTEX. Significant pH drop of a filling material was not observed during the biofilter operation of 1 month. Without mixing the landfill gas stream with all, the removal rate of $H_2$S decreased down to 30%.

  • PDF

Pervaporation Separation of Trace Dicholoromethane from Water Using Fluorinated Polysiloxaneimide do Membranes (불소계 폴리실록산이미드 공중합체막을 이용한 저농도 Dichloromethane 수용액의 투과증발)

  • Kim, Jeong-Hoon;Chang, Bong-Jun;Lee, Soo-Bok
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.184-190
    • /
    • 2007
  • This study reports on the pervaporation separation of a volatile organic compound(VOC), dichloromethane(DCM) from water using fluorinated copolysiloxaneimide membranes. The copolysiloxaneimide membranes were prepared from 4,4'-(hexafluoroisopropylidene)diphthalic anhydride(6FDA) and two diamines(polysiloxane diamine(SIDA), 2-(perfluorohexyl)ethyl-3,5-diaminobenzene(PFDAB)). By varying the ratio of flexible polysiloxane diamine(SIDA)/rigid fluorinated aromatic diamine(PFDAB) from 0/100 to 100/0 mol%, five copolysiloxaneimide membranes were prepared success- fully. The pervaporation properties of DCM/water were examined in terms of two diamine monomer ratio at room temperature and the feed composition of 0.05 wt% in water. It was found that the increase in SIDA content led to high permeation flux and pervaporation selectivity towards DCM by the enhanced sorption/sorption selectivity and diffusion coefficient/diffusion selectivity due to the increased hydrophobicity and fractional free volume.

Measurement and Evaluation of Indoor Air Quality in Small-scale apartments in Daegu (대구지역의 신축 소규모 공동주택에 있어서 실내공기질 측정 및 평가)

  • Park, Hyun-Sik;Kim, Hyun-Tae;Hong, Won-Hwa
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.217-223
    • /
    • 2019
  • The purpose of this study was to measure the indoor air quality of small-scale apartments and then proposed a method to improve the indoor air quality of the small-scale apartments by comparing with the result of indoor air quality in the Clean-Healthy House. In case of formaldehyde, a highly volatile organic compound, the concentrations of indoor measured both in small-scale apartments and the Clean Healthy houses did not exceed- the guideline of Korea. The guideline of Korea for acetaldehyde was not available, so the guidelines of Japan and the World Health Organization were used to measure the concentration of acetaldehyde. The study results demonstrated that three out of seven small-scale apartments investigated exceeded the guideline of Japan; and the preliminary research on the Clean-Health Houses was low at about 30-60% of the guideline of Japan. The result of the VOCs measurement showed that toluene, ethylbenzene, and styrene in some small-scale apartments exceeded the guideline of Korea. However, the Clean-Healthy Houses in the previous studies did not exceed the guideline of Korea with regard to all the pollutants. Therefore, this study suggests the application of the construction standards of the Clean-Healthy house in order to improve the indoor air quality of small-scale apartments. In addition, the current study anticipates that improvement of the indoor air quality in the residential environments should be universally applied, not limited to the type and size of the residence.

Characteristics of concentration distribution for indoor air pollutants (VOCs and Carbonyl compounds) in new apartments (신축 공동주택에서 실내공기오염물질(휘발성유기화합물 및 카보닐화합물) 농도분포 특성)

  • Jang, Seong-Ki;Chun, Jae-Young;Lee, Tae-Young;Lim, Soo-Gil;Lu, Jung-Min;Seo, Soo-Yun;Lim, Jeong-Yun
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.17-24
    • /
    • 2007
  • This study was performed to investigate the distributions of volatile organic compounds and carbonyl compounds at the 120 households in new apartments before occupation. The concentration of toluene, m, p-xylene, formaldehyde, acetone and ethylbenzene dominated as $272.81{\mu}g/m^3$, $98.90{\mu}g/m^3$, $71.68{\mu}g/m^3$, $70.58{\mu}g/m^3$ and $49.76{\mu}g/m^3$, respectively. The identified compounds by standards occupied 42.5% of the TVOCs, also the concentration of toluene occupied the largest part of the identified compounds as 18.5%. The concentration of formaldehyde and acetone were 43.1% and 42.4% among carbonyl compounds. The indoor/outdoor ratio of the concentration of benzene, toluene, formaldehyde and o-xylene were investigated 1.29, 3.59, 10.76 and 28.74, respectively.