• Title/Summary/Keyword: VIS

Search Result 2,260, Processing Time 0.028 seconds

The Proposed Validation Guidelines and Their Application for Performance Verification of UV-VIS Spectrophotometer (UV-VIS 분광기기의 성능검증을 위한 밸리데이션 가이드라인의 제정 및 응용)

  • Jin, Jing-Yu;Kang, Young-Koo;Lee, Won-Jae
    • YAKHAK HOEJI
    • /
    • v.50 no.3
    • /
    • pp.154-159
    • /
    • 2006
  • For the increasing demand for the validation of analytical results, one of the important concerns of the analyst is to be assured that the instrumentation is working to qualified conditions. In this study, we have investigated and compared several validation guidelines of the performance verification of UV-VIS spectrophotometer used in pharmacopoeias of major countries and UV-VIS instrument analytical companies, and we proposed the practically useful validation guidelines of UV-VIS spectrophotometer. Based on our proposed validation guidelines of UV-VIS spectrophotometer, several UV-VIS spectrophotometers used in drug manufacturing laboratories were validated for their performances.

A Design of the Safe Zone Managing Algorithm with the Variable Interval Sensing Scheme for the Sensor Networks

  • Cha, Hyun-Chul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.10
    • /
    • pp.29-35
    • /
    • 2016
  • In this paper, we propose a scheme to prolong the lifetime of the sensor network by reducing the power consumption of the sensor node. The proposed algorithm reduces the number of transmissions and sensing at the application layer. We combine the VIS scheme with the MSZ algorithm and call it as the SZM/VIS algorithm. The actual temperature data was collected using the sensor nodes to assess the performance of the proposed algorithm. The proposed algorithm was implemented through the programming and was evaluated under various setting values. Experimental results show that the SZM/VIS has a slightly improved transmission ratio than that of the MSZ while has the periodic transmission capability like as the MSZ. Also the SZM/VIS can significantly reduces the sensing ratio like that of the VIS. Our algorithm has the advantages of instantaneous, simplicity, small overhead and robustness. Our algorithm has just negligible side effects by controlling the parameter properly depending on the application types. The SZM/VIS algorithm will be able to be used effectively for the applications that need to be managed within a certain range of specific properties, such like crop management.

Reflectance estimation for infrared and visible image fusion

  • Gu, Yan;Yang, Feng;Zhao, Weijun;Guo, Yiliang;Min, Chaobo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.8
    • /
    • pp.2749-2763
    • /
    • 2021
  • The desirable result of infrared (IR) and visible (VIS) image fusion should have textural details from VIS images and salient targets from IR images. However, detail information in the dark regions of VIS image has low contrast and blurry edges, resulting in performance degradation in image fusion. To resolve the troubles of fuzzy details in dark regions of VIS image fusion, we have proposed a method of reflectance estimation for IR and VIS image fusion. In order to maintain and enhance details in these dark regions, dark region approximation (DRA) is proposed to optimize the Retinex model. With the improved Retinex model based on DRA, quasi-Newton method is adopted to estimate the reflectance of a VIS image. The final fusion outcome is obtained by fusing the DRA-based reflectance of VIS image with IR image. Our method could simultaneously retain the low visibility details in VIS images and the high contrast targets in IR images. Experiment statistic shows that compared to some advanced approaches, the proposed method has superiority on detail preservation and visual quality.

Development of Visible-light Responsive $TiO_2$ Thin Film Photocatalysts by Magnetron Sputtering Method and Their Applications as Green Chemistry Materials

  • Matsuoka, Masaya
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.3.1-3.1
    • /
    • 2010
  • Water splitting reaction using photocatalysts is of great interest in the utilization of solar energy [1]. In the present work, visible light-responsive $TiO_2$ thin films (Vis-$TiO_2$) were prepared by a radio frequency magnetron sputtering (RF-MS) deposition method and applied for the separate evolution of $H_2$ and $O_2$ from water as well as the photofuel cell. Special attentions will be focused on the effect of HF treatment of Vis-$TiO_2$ thin films on their photocatalytic activities. Vis-$TiO_2$ thin films were prepared by an RF-MS method using a calcined $TiO_2$ plate and Ar as the sputtering gas. The Vis-$TiO_2$ thin films were then deposited on the Ti foil substrate with the substrate temperature at 873 K (Vis-$TiO_2$/Ti). Vis-$TiO_2$/Ti thin films were immersed in a 0.045 vol% HF solution at room temperature. The effect of HF treatments on the activity of Vis-$TiO_2$/Ti thin films for the photocatalytic water splitting reaction have been investigated. Vis-$TiO_2$/Ti thin films treated with HF solution (HF-Vis-$TiO_2$/Ti) exhibited remarkable enhancement in the photocatalytic activity for $H_2$ evolution from a methanol aqueous solution as well as in the photoelectrochemical performance under visible light irradiation as compared with the untreated Vis-$TiO_2$/Ti thin films. Moreover, Pt-loaded HF-Vis-$TiO_2$/Ti thin films act as efficient and stable photocatalysts for the separate evolution of $H_2$ and $O_2$ from water under visible light irradiation in the presence of chemical bias. Thus, HF treatment was found to be an effective way to improve the photocatalytic activity of Vis-$TiO_2$/Ti thin films. Furthermore, unique separate type photofuel cell was fabricated using a Vis-$TiO_2$ thin film as an electrode, which can generate electrical power under solar light irradiation by using various kinds of biomass derivatives as fuel. It was found that the introduction of an iodine ($I^-/{I_3}^-$) redox solution at the cathode side enables the development of a highly efficient photofuel cell which can utilize a cost-efficient carbon electrode as an alternative to the Pt cathode.

  • PDF

Basin modelling with a MATLAB-based program, BasinVis 2.0: A case study on the southern Vienna Basin, Austria (MATLAB 기반의 프로그램 BasinVis 2.0을 이용한 분지 모델링: 오스트리아 비엔나 분지의 남부 지역에 대한 사례 연구)

  • Lee, Eun Young;Wagreich, Michael
    • Journal of the Geological Society of Korea
    • /
    • v.54 no.6
    • /
    • pp.615-630
    • /
    • 2018
  • Basin analysis is a research field to understand the formation and evolution of sedimentary basins. This task requires various geoscientific datasets as well as numerical and graphical modelling techniques to synthesize results dimensionally in time and space. For basin analysis and modelling in a comprehensive workflow, BasinVis 1.0 was released as a MATLAB-based program in 2016, and recently the software has been extended to BasinVis 2.0, with new functions and revised user-interface. As a case study, this work analyses the southern Vienna Basin and visualizes the sedimentation setting and subsidence evolution to introduce the basin modelling functions of BasinVis 2.0. This is a preliminary study for a basin-scale modelling of the Vienna Basin, together with our previous studies using BasinVis 1.0. In the study area, during the late Early Miocene, sedimentation and subsidence are significant along strike-slip and en-echelon listric normal faults. From the Middle Miocene onwards, however, subsidence decreases abruptly over the area and this situation continues until the Late Miocene. This is related to the development of the pull-apart system and corresponds to the episodic tectonic subsidence in strike-slip basins. The subsidence of the Middle Miocene is confined mainly to areas along the strike-slip faults, while, from the late Middle Miocene, the depocenter shifts to a depression along the N-S trending listric normal faults. This corresponds to the regional paleostress regime transitioning from NE-SW trending transtension to E-W trending extension. This study applies various functions and techniques to this case study, and the modelled results demonstrate that BasinVis 2.0 is effective and applicable to the basin modelling.

The Determination of Germanium(IV) by Linear Sweep Voltammetry and UV-VIS Spectrophotometry (Linear Sweep Voltammetry와 UV-VIS Spectrophotometry를 이용한 게르마늄 분석)

  • Choi, Won-Hyung;Lee, Jin-Sik;Kim, Jae-Soo;Kim, Do-Hun
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.7-15
    • /
    • 1992
  • Germainium(IV) was determined in perchloate supporting electrolyte solution containing phenylfluorone by hanging mercury drop electrode(HMDE) of Linear Sweep Voltammetry(LSV) and in hydrochloric acid solution by UV-VIS Spectrophotometry. The complex germanium(IV) with phenylfluorone was shown linear calibration curve in the range of $2.5{\sim}80{\mu}g/L$ by LSV and in the range of $10{\sim}300{\mu}g/L$ by UV-VIS Spectrophotometry.

  • PDF

Early Detection of Clear Egg in Incubation Using VIS/NIR Spectroscopy (VIS/NIR 분광분석법을 이용한 미부화란의 조기 검출)

  • Kim, Hak Sung;Kim, Ghi Seok;Kim, Yong Ro;Kang, Seok Won;Noh, Sang Ha
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.104-104
    • /
    • 2017
  • 정상적인 부화 여부를 판별하기 위한 1차 검란은 일반적으로 5일~7일 이후에 시행된다. 미부화란을 이보다 더 빠른 시간 안에 검출할 경우 부화에 소요되는 에너지의 감소 효과 및 미부화란을 다른 용도로 활용하는 것을 기대할 수 있다. 시중에서 쉽게 구입할 수 있는 산란계인 하이라인 브라운 품종의 유정란 29개와 인위적인 미부화란을 만들기 위한 동일 품종의 무정란 11개를 사용하였으며 $38^{\circ}C$, 70% 조건의 항온항습기에서 96시간 동안 부화하였다. 스펙트럼 획득 장치의 광원은 녹색영역을 발광하는 LED램프와 일반 할로겐 광원을 별도로 사용하였으며 스펙트로미터는 VIS/NIR 영역인 520~1,180nm영역과 NIR영역인 900~1,700nm영역의 것을 사용하였다. 부화 시작 전과 부화 시작 후 1일 간격으로 각각 1개의 샘플에 대한 1개의 스펙트럼을 측정하였다. 측정 영역은 LED광원을 이용한 경우는 520~1,1800nm, 할로겐광원을 이용한 경우에는 520~1,180nm와 900~1,700nm이었다. 정상 부화여부는 4일차에서 할란하여 확인하였고, 측정 일자별로 PLS-DA분석법을 이용한 판별 모델을 개발하였다. 4일차에서 유정란 29개 중 11개가 정상 부화하였고, 18개는 미부화하였다. 3일차에서 판별 모델의 정확도는 LED광원의 VIS/NIR 영역 스펙트럼을 이용한 경우는 100%, 할로겐 광원의 VIS/NIR 영역 스펙트럼을 이용한 경우는 70%, 할로겐 광원의 NIR영역 스펙트럼을 이용한 경우는 70%였다. 4일차에서 판별 모델의 정확도는 LED광원의 VIS/NIR 영역 스펙트럼을 이용한 경우는 100%, 할로겐 광원의 VIS/NIR 영역 스펙트럼을 이용한 경우는 90%, 할로겐 광원의 NIR영역 스펙트럼을 이용한 경우는 100%였다. 부화 3일차는 정상 부화할 경우 피가 생성되는 시기이다. 피가 형성된 이후의 부화 여부를 판단하는 광원으로는 할로겐램프보다 LED램프를 사용하는 것이 더 적합한 것으로 나타났다.

  • PDF

Eine Untersuchung $\"{u}ber$ Ciceros Partitiones oratoriae (키케로의 수사학 교본 Partitiones oratoriae 연구)

  • Yang Tae-zong
    • Koreanishche Zeitschrift fur Deutsche Sprachwissenschaft
    • /
    • v.10
    • /
    • pp.25-44
    • /
    • 2004
  • Der Rhetorik Ciceros wird such im heutigen Rhetorik-Boom als innerhalb der westlichen Tradition am einflussreichsten angesehen. Deshalb versucht diese Arbeit, anhand seines Buches Partitiones Oratoriae die Grundkonzepte seines Denkens heraus zu arbeiten. Das Hauptthema dieses Buches ist die Redelehre, die aus VIS ORATORIS, ORATIO und QUAESTIO besteht. Jeder Hauptteil hat seinerseits Subsektionen. Vis Oratoris wird z.B. in weitere funf Bereiche eingeteilt: INVENTIO, CONLOCATIO, ELOCUTIO, ACTIO und MEMORIA. Oratio in vier: PRINCIPIUM, NARRATIO, ARGUMENTATIO und PERORATIO; die Quaestio in zwei: CONSULTATIO und CAUSA. Unser Ausgangspunkt ist die erste Klassifikation der Redelehre. Unsere Untersuchung hat gezeigt, dass die Quaestio nicht nor mil der Vis Oratoris sondern auch mil der Oratio Gemeinsamkeiten hat. 'Der Gedanke'(RES) der Consultatio ist ein Teil von Inventio und Conlocatio im Bereich der Vis Oratoris, und ein Teil von Narratio und Peroratio im Bereich der Oratio. Das gilt auch fur die Cauga, einen anderen Teil der Quaestio. Daraus ergibt sich die Moglichkeit der Integration der Qaestio z.B. in Vis, weil der Ausdruck (VERBA) sicherlich zur Eiocutio $geh\"{o}rt$ - bei der Darstellung der Quaestio wie bei der der Vis geht Cicero von der Unterscheidung res-verba aus. Aus solch reduktionistischer Sicht $k\"{o}nnen$ wir auch die Oratio in die Vis integrieren, weil die Funktionen der Redeteile der Stoff der Inventio sind. Die Inventio sucht nach Wegen, sich $vertrauensw\"{u}rdig$ zu machen und Emotionen zu wecken. Der erste Weg dahin ist die Funktion von Narratio und Argumentatio, und der zweite Weg die von Principium und Peroratio. Es gibt weitere interessante Punkte: die Ausweichung der Memoria von der $\"{u}blichen$ Produktionsstufe der Rede, die Gewichtsverlagerung der Oratio auf die Narratio, die Hervorhebung der gerichtlichen Rede wegen ihres dialektischen Zuges, die Bevorzugung der $Vertrauensw\"{u}rdigkeit$ (der Emotionen gegeniuber) usw. Es bleibt naturlich strittig, welche Sichtweise zwischen den Polen Integration und der Ausdifferenzierung angemessen ist. Trotzdem ist klar, dass Cicero $gro{\ss}en$Wert nicht auf VERBA, sondern auf RES gelegt hat. $F\"{u}r$ ihn ist vor allem Vertrauenswurdigkeit am wichtigsten.

  • PDF

기술연재 / 'VIS'저작툴, 플레이어, 서버 등 토탈 솔루션 제공

  • Jeong, Gu-Min
    • Digital Contents
    • /
    • no.6 s.121
    • /
    • pp.146-148
    • /
    • 2003
  • IMT-2000의 궁극적인 목표가 멀티미디어 서비스의 자유로운 제공과 그 향유에 있다면, 멀티미디어 솔루션의 발전과 진화는 매우 중요한 부분이다. 지난 호에서는 무선인터넷 멀티미디어 기술의 필요성, 현재 국내외 무선인터넷 현황과 멀티미디어 솔루션 현황을 정리했다. 그리고 무선인터넷 멀티미디어의 새로운 장을 열어줄 VIS의 개요와 의의에 대해 설명하고 간단한 VIS 콘텐츠의 예를 들었다.이번 호에서는 VIS 콘텐츠의 구성, 기능, 특징 및 기술적인 부분에 대해 정리하도록 했다.

  • PDF

Food Powder Classification Using a Portable Visible-Near-Infrared Spectrometer

  • You, Hanjong;Kim, Youngsik;Lee, Jae-Hyung;Jang, Byung-Jun;Choi, Sunwoong
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.4
    • /
    • pp.186-190
    • /
    • 2017
  • Visible-near-infrared (VIS-NIR) spectroscopy is a fast and non-destructive method for analyzing materials. However, most commercial VIS-NIR spectrometers are inappropriate for use in various locations such as in homes or offices because of their size and cost. In this paper, we classified eight food powders using a portable VIS-NIR spectrometer with a wavelength range of 450-1,000 nm. We developed three machine learning models using the spectral data for the eight food powders. The proposed three machine learning models (random forest, k-nearest neighbors, and support vector machine) achieved an accuracy of 87%, 98%, and 100%, respectively. Our experimental results showed that the support vector machine model is the most suitable for classifying non-linear spectral data. We demonstrated the potential of material analysis using a portable VIS-NIR spectrometer.