• Title/Summary/Keyword: V2C

Search Result 9,802, Processing Time 0.064 seconds

A Review of Responses of Nursing Students Following Clinical Maternity Nursing Practice (모성 간호 실습 후 분만과정에 대한 간호학생의 심리적 반응 고찰 -모성 간호 실습, 실습에 대한 간호학생의 심리적 반응-)

  • Cho, Cheong-Ho
    • 모자간호학회지
    • /
    • v.4 no.1
    • /
    • pp.41-51
    • /
    • 1994
  • The purposes of this study were to identify responses of nursing students following clinical maternity nursing practice, to develop data of further effective clinical maternity nursing practice, to understand nursing students perceive the natural maturation process toward pregnancy delivery and puerperal process, to help the nursing students achieve personality growth and development through clinical maternity nursing practice. The subjects were 35 senior nursing students from the Department of Nursing Science of Chung-Ang University. The data were collected from the 1st semester (Feb.22$\sim$June 9) to the 2nd semester(Aug.23$\sim$Nov.10), 1993 through self-reporting using an open ended questionnaire about perception and feelings regarding the normal delivery process. The data analysis used descriptive method. Results of the study were as follows : 1. Following clinical practice in maternity nursing, the responses of the nursing students were collected included both positive and negative aspects. The positive responses were classified in to four categories and each category included subgroups. One group, labelled as $\ulcorner$The birth of noble life$\lrcorner$ had a subgroup, (I felt the mystery and wonder of life), another group, $\ulcorner$After delivery, comfort and satisfaction$\lrcorner$ with the subgroup (I can bear to see the comfort and relief beyond pain) (C/S is better than vaginal delivery) (Very easy), the 3rd group, $\ulcorner$ I realized family friendship and support$\lrcorner$ with subgroup (Honorable, Magnificient) (I thank my parents ) (It's good to looking at my husband's support), and the 4th group, $\ulcorner$The birth of a healthy baby$\lrcorner$, with its subgroup, (baby looks pretty and healthy). 2. The negative responses were classified in eight categories and each category included subgroups. One group labelled as $\ulcorner$Fear$\lrcorner$, had subgroups of (Terrible, Horrible) (Shock) (Dread), another group, $\ulcorner$Tension$\lrcorner$, and its subgroup, (I became tense about stories heard before clinical practice), the 3rd group, $\ulcorner$surprise$\lrcorner$ and its subgroup (I was surprised at the delivery process), the 4th group, $\ulcorner$Power lessness$\lrcorner$ and its subgroup, (I watched the labor pain impatiently), the 5th group $\ulcorner$Apathy$\lrcorner$ ; and its subgroup, (I didn't feel the empathy for the labor pain of the pregnant women), the 6th group, $\ulcorner$Disgust$\lrcorner$ and its subgroup, (Disgust, Embarrassed), the 7th group, $\ulcorner$Inevitable destiny$\lrcorner$ and its subgroups (necessity of self-sacrifice and difficulty) (I accepted it as a women's destiny) (I can't do it), the last group, $\ulcorner$There seems to be trouble$\lrcorner$ and its subgroup, (It seems to have been a little too hard for mother and baby). Suggestions for further studies are as follows : 1. Nursing students should receive intensive education about $\ulcorner$The birth of noble life$\lrcorner$ $\ulcorner$After delivery, comfort and satisfaction$\lrcorner$ $\ulcorner$I realized family friendship and support$\lrcorner$ $\ulcorner$The birth of a healthy baby$\lrcorner$, so that a more positive attitude can be developed before clinical maternity nursing. 2. Nursing students should be given an orientation which is reality based and related clinical maternity nursing (using for A.V. Materials), so that they will not feel they tension, of the negative categories. 3. Nursing students should be received articles on Pain Relief Method, so that they will be prepared activie and positive in the clinical practice, and therefore they will not feel the powerlessness, of the negative categories. 4. F/U for responses of nursing students should be checked following clinical maternity nursing to evaluate the effects of the instruction.

  • PDF

The Effects of Inductive Activities Using GeoGebra on the Proof Abilities and Attitudes of Mathematically Gifted Elementary Students (GeoGebra를 활용한 귀납활동이 초등수학영재의 증명능력 및 증명학습태도에 미치는 영향)

  • Kwon, Yoon Shin;Ryu, Sung Rim
    • Education of Primary School Mathematics
    • /
    • v.16 no.2
    • /
    • pp.123-145
    • /
    • 2013
  • This study was expected to yield the meaningful conclusions from the experimental group who took lessons based on inductive activities using GeoGebra at the beginning of proof learning and the comparison one who took traditional expository lessons based on deductive activities. The purpose of this study is to give some helpful suggestions for teaching proof to mathematically gifted elementary students. To attain the purpose, two research questions are established as follows. 1. Is there a significant difference in proof abilities between the experimental group who took inductive lessons using GeoGebra and comparison one who took traditional expository lessons? 2. Is there a significant difference in proof attitudes between the experimental group who took inductive lessons using GeoGebra and comparison one who took traditional expository lessons? To solve the above two research questions, they were divided into two groups, an experimental group of 10 students and a comparison group of 10 students, considering the results of gift and aptitude test, and the computer literacy among 20 elementary students that took lessons at some education institute for the gifted students located in K province after being selected in the mathematics. Special lesson based on the researcher's own lesson plan was treated to the experimental group while explanation-centered class based on the usual 8th grader's textbook was put into the comparison one. Four kinds of tests were used such as previous proof ability test, previous proof attitude test, subsequent proof ability test, and subsequent proof attitude test. One questionnaire survey was used only for experimental group. In the case of attitude toward proof test, the score of questions was calculated by 5-point Likert scale, and in the case of proof ability test was calculated by proper rating standard. The analysis of materials were performed with t-test using the SPSS V.18 statistical program. The following results have been drawn. First, experimental group who took proof lessons of inductive activities using GeoGebra as precedent activity before proving had better achievement in proof ability than the comparison group who took traditional proof lessons. Second, experimental group who took proof lessons of inductive activities using GeoGebra as precedent activity before proving had better achievement in the belief and attitude toward proof than the comparison group who took traditional proof lessons. Third, the survey about 'the effect of inductive activities using GeoGebra on the proof' shows that 100% of the students said that the activities were helpful for proof learning and that 60% of the reasons were 'because GeoGebra can help verify processes visually'. That means it gives positive effects on proof learning that students research constant character and make proposition by themselves justifying assumption and conclusion by changing figures through the function of estimation and drag in investigative software GeoGebra. In conclusion, this study may provide helpful suggestions in improving geometry education, through leading students to learn positive and active proof, connecting the learning processes such as induction based on activity using GeoGebra, simple deduction from induction(i.e. creating a proposition to distinguish between assumptions and conclusions), and formal deduction(i.e. proving).

LC-MS/MS analysis and anti-inflammatory effects of crude extract from Coptidis Rhizoma (황련 추출물의 LC-MS/MS 분석 및 항염증 효과)

  • Min-Jung, Kim;Ye-Jin, Yang;Kwang-Youn, Kim;Hun Hwan, Kim;Jae Dong, Son;Ju-Hye, Yang;Dong bin, Lee;Woo Hyun, Kim;Hu-Jang, Lee;Seon Been, Bak;Kwang-Il, Park
    • Herbal Formula Science
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • Objectives : The main aim of this study was to examine the LC-MS/MS used to identify phenolic compounds of CRE(Coptidis Rhizoma 70% EtOH Extract). Also, we investigated antioxidative activities and Anti-inflammatory activities. Methods : LC-MS/MS Analysis HPLC and LC-MS/MS were performed on a 1260 series HPLC system (Agilent Technologies, Inc., California, USA) and 3200 QTrap tandem mass system (Sciex LLC) operated in positive ion mode (spray voltage set at -4.5 kV). The solvent used was DW and Acetonitrile containing 0.1% formic acid, a gradient system was used at a flow rate of 0.5 mL/min for analysis, and a Prontosil C18 column (length, 250 mm; inner diameter, 4.6 mm; particle size, 5 ㎛; Phenomenex Co., Ltd., California, USA, Biochoff Chromatography) was used. The solvent conditions used in the mobile phases were 0-10 min at 10-15% B, 10-20 min at 20% B, 20-30 min at 25%, 30-40 min at 40%, 40-50 min at 70%, 50-60 min at 95%, and 60-70 min at 95%. The analysis was performed at a wavelength of 284 nm and a temperature of 35℃. The cell viability was measured using a 3-(4,5-dimethyethiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay and 1,1-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging activity. We examined the effects of CRE on the lipopolysaccharide (LPS)-induced production of nitric oxide (NO) in a RAW 264.7 cells Results : The chemical analysis CRE by Liquid chromatography-tandem mass spectrometry (LC-MS/MS) confirmed that Rosmarinic acid, Ferrulic acid, 3-O-feruloylquinic acid, and 5-O-feruloylquinic acid as phenolic components. DPPH radical scavenging activity was the inhibitory activity of CRE showed at 200 ㎍/mL a statistically significant level. MTT assay demonstrated that the CRE did not have a cytotoxic effect in RAW 264.7 and LPS-induced RAW264.7 cells. Also, CRE reduced NO production in RAW 264.7 cells stimulated with LPS. Conclusions : Based on these findings, The chemical analysis 4 major components CRE such as Rosmarinic acid, Ferrulic acid, 3-O-feruloylquinic acid, and 5-O-feruloylquinic acid. Moreover, we confirmed that CRE has effects antioxidant and anti-inflammatory. The results demonstrate that CRE can be used as an antioxidant and a powerful chemopreventive ingredient against inflammatory diseases.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Importance of End User's Feedback Seeking Behavior for Faithful Appropriation of Information Systems in Small and Medium Enterprises (중소기업 환경에서의 합목적적 정보시스템 활용을 위한 최종사용자 피드백 탐색행위의 중요성)

  • Shin, Young-Mee;Lee, Joo-Ryang;Lee, Ho-Geun
    • Asia pacific journal of information systems
    • /
    • v.17 no.4
    • /
    • pp.61-95
    • /
    • 2007
  • Small-and-medium sized enterprises(SMEs) represent quite a large proportion of the industry as a whole in terms of the number of enterprises or employees. However researches on information system so far have focused on large companies, probably because SMEs were not so active in introducing information systems as larger enterprises. SMEs are now increasingly bringing in information systems such as ERP(Enterprise Resource Planning Systems) and some of the companies already entered the stage of ongoing use. Accordingly, researches should deal with the use of information systems by SME s operating under different conditions from large companies. This study examined factors and mechanism inducing faithful appropriation of information systems, in particular integrative systems such as ERP, in view of individuals` active feedback-seeking behavior. There are three factors expected to affect end users` feedback-seeking behavior for faithful appropriation of information systems. They are management support, peer IT champ support, and IT staff support. The main focus of the study is on how these factors affect feedback-seeking behavior and whether the feedback-seeking behavior plays the role of mediator for realizing faithful appropriation of information systems by end users. To examine the research model and the hypotheses, this study employed an empirical method based on a field survey. The survey used measurements mostly employed and verified by previous researches, while some of the measurements had gone through minor modifications for the purpose of the study. The survey respondents are individual employees of SMEs that have been using ERP for one year or longer. To prevent common method bias, Task-Technology Fit items used as the control variable were made to be answered by different respondents. In total, 127 pairs of valid questionnaires were collected and used for the analysis. The PLS(Partial Least Squares) approach to structural equation modeling(PLS-Graph v.3.0) was used as our data analysis strategy because of its ability to model both formative and reflective latent constructs under small-and medium-size samples. The analysis shows Reliability, Construct Validity and Discriminant Validity are appropriate. The path analysis results are as follows; first, the more there is peer IT champ support, the more the end user is likely to show feedback-seeking behavior(path-coefficient=0.230, t=2.28, p<0.05). In other words, if colleagues proficient in information system use recognize the importance of their help, pass on what they have found to be an effective way of using the system or correct others' misuse, ordinary end users will be able to seek feedback on the faithfulness of their appropriation of information system without hesitation, because they know the convenience of getting help. Second, management support encourages ordinary end users to seek more feedback(path-coefficient=0.271, t=3.06, p<0.01) by affecting the end users' perceived value of feedback(path-coefficient=0.401, t=6.01, p<0.01). Management support is far more influential than other factors that when the management of an SME well understands the benefit of ERP, promotes its faithful appropriation and pays attention to employees' satisfaction with the system, employees will make deliberate efforts for faithful appropriation of the system. However, the third factor, IT staff support was found not to be conducive to feedback-seeking behavior from end users(path-coefficient=0.174, t=1.83). This is partly attributable to the fundamental reason that there is little support for end users from IT staff in SMEs. Even when IT staff provides support, end users may find it less important than that from coworkers more familiar with the end users' job. Meanwhile, the more end users seek feedback and attempt to find ways of faithful appropriation of information systems, the more likely the users will be able to deploy the system according to the purpose the system was originally meant for(path-coefficient=0.35, t=2.88, p<0.01). Finally, the mediation effect analysis confirmed the mediation effect of feedback-seeking behavior. By confirming the mediation effect of feedback-seeking behavior, this study draws attention to the importance of feedback-seeking behavior that has long been overlooked in research about information system use. This study also explores the factors that promote feedback-seeking behavior which in result could affect end user`s faithful appropriation of information systems. In addition, this study provides insight about which inducements or resources SMEs should offer to promote individual users' feedback-seeking behavior when formal and sufficient support from IT staff or an outside information system provider is hardly expected. As the study results show, under the business environment of SMEs, help from skilled colleagues and the management plays a critical role. Therefore, SMEs should seriously consider how to utilize skilled peer information system users, while the management should pay keen attention to end users and support them to make the most of information systems.

Drainage Performance of Various Subsurface Drain Materials- (배수개선공법개발에 관한 연구(I) -각종 지하배수용 암거재료의 배수성능-)

  • 김철회;이근후;유시조;서원명
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.21 no.3
    • /
    • pp.104-120
    • /
    • 1979
  • I. Title of the Study Studies on the Development of Improved Subsurface Drainage Methods. -Drainage Performance of Various Subsurface Drain Materials- II. Object of the Study Studies were carried out to select the drain material having the highest performance of drainage; And to develop the water budget model which is necessary for the planning of the drainage project and the establishment of water management standards in the water-logged paddy field. III. Content and Scope of the Study 1. The experiment was carried out in the laboratory by using a sand tank model. The drainage performance of various drain materials was compared evaluated. 2. A water budget model was established. Various parameters necessary for the model were investigated by analyzing existing data and measured data from the experimental field. The adaptability of the model was evaluated by comparing the estimated values to the field data. IV. Results and Recommendations 1. A corrugated tube enveloped with gravel or mat showed the highest drainage performance among the eight materials submmitted for the experiment. 2. The drainage performance of the long cement tile(50 cm long) was higher than that of the short cement tile(25 cm long). 3. Rice bran was superior to gravel in its' drain performance. 4. No difference was shown between a grave envelope and a P.V.C. wool mat in their performance of drainage. Continues investigation is needed to clarify the envelope performance. 5. All the results described above were obtained from the laboratory tests. A field test is recommended to confirm the results obtained. 6. As a water balance model of a given soil profile, the soil moisture depletion D, could be represented as follows; $$D=\Sigma\limit_{t=1}^{n}(Et-R_{\ell}-I+W_d)..........(17)$$ 7. Among the various empirical formulae for potential evapotranspiration, Penman's formular was best fit to the data observed with the evaporation pans in Jinju area. High degree of positive correlation between Penman;s predicted data and observed data was confirmed. The regression equation was Y=1.4X-22.86, where Y represents evaporation rate from small pan, in mm/100 days, and X represents potential evapotranspiration rate estimated by Penman's formular. The coefficient of correlation was r=0.94.** 8. To estimate evapotranspiration in the field, the consumptive use coefficient, Kc, was introduced. Kc was defined by the function of the characteristics of the crop soil as follows; $Kc=Kco{\cdot}Ka+Ks..........(20)$ where, Kco, Ka ans Ks represents the crop coefficient, the soil moisture coefficient, and the correction coefficient, respectively. The value of Kco and Ka was obtained from the Fig.16 and the Fig.17, respectively. And, if $Kco{\cdot}Ka{\geq}1.0,$ then Ks=0, otherwise, Ks value was estimated by using the relation; $Ks=1-Kco{\cdot}Ka$. 9. Into type formular, $r_t=\frac{R_{24}}{24}(\frac{b}{\sqrt{t}+a})$, was the best fit one to estimate the probable rainfall intensity when daily rainfall and rainfall durations are given as input data, The coefficient a and b are shown on the Table 16. 10. Japanese type formular, $I_t=\frac{b}{\sqrt{t}+a}$, was the best fit one to estimate the probable rainfall intensity when the rainfall duration only was given. The coefficient a and b are shown on the Table 17. 11. Effective rainfall, Re, was estimated by using following relationships; Re=D, if $R-D\geq}0$, otherwise, Re=R. 12. The difference of rainfall amount from soil moisture depletion was considered as the amount of drainage required. In this case, when Wd=O, Equation 24 was used, otherwise two to three days of lag time was considered and correction was made by use of storage coefficient. 13. To evaluate the model, measured data and estimated data was compared, and relative error was computed. 5.5 percent The relative error was 5.5 percent. 14. By considering the water budget in Jinju area, it was shown that the evaporation amount was greater than the rainfall during period of October to March in next year. This was the behind reasonning that the improvement of surface drainage system is needed in Jinju area.

  • PDF

Standardization and Reliability and Validity of the Korean Edition of Profile of Mood States(K-POMS) (한국판 기분상태척도(K-POMS)의 표준화와 신뢰도와 타당도 평가)

  • Kim, Eui-Joong;Lee, Sang-Ick;Jeong, Do-Un;Shin, Min-Sup;Yoon, In-Young
    • Sleep Medicine and Psychophysiology
    • /
    • v.10 no.1
    • /
    • pp.39-51
    • /
    • 2003
  • Objectives: The Profile of Mood States (POMS) has been used broadly and frequently in various medical studies with various subjects. For the development and application of the Korean edition of POMS, called K-POMS, we translated POMS into Korean and then evaluated the reliability and validity of K-POMS. Methods: The subjects were 161 male students with a mean age of 18.1 years (15-30) and 244 female students with a mean age of 16.6 years (14-23). They were requested to perform K-POMS and SCL-90-R (Korean version) at the same time. Means, reliability coefficients, and test-retest correlations of K-POMS were calculated. Content validities, correlations with SCL-90-R, and discrimination validities in comparison with 76 depressive patients were obtained, and factor analyses were carried out. Results: Mean scores of Total Mood Disturbance (TMD) and some subscales (T, F, C, V factor) showed a significant difference between male and female students. The internal consistency coefficient ($\alpha$) of the total 65 items was 0.93, and ranged from 0.67 to 0.90 for subscales. Test-retest correlations of 43 subjects ranged from 0.27 to 0.63. Seven psychiatrists rated the properness of the content of each item as more than moderate degree (mean scale points=2.66, in the range of 0 to 4). Every subscale of KPOMS exhibited significant correlation with the matching subscale of SCL-90-R. Mean scores of K-POMS of the total 405 subjects were significantly different from those of the 76 depressive subjects after age correction. Six factors were extracted, accounting for 51.2% of total variance. Factor 6 consisted of 6 items which came from various subscales of POMS and represented "uncertainty and helplessness," which may be somewhat different to depression or sadness proper. Conclusion: The validity and reliability of K-POMS could be confirmed. The significant difference in K-POMS scores between depressive subjects and normal subjects suggests that K-POMS can be used clinically for the evaluation and screening of depression. The main structure of K-POMS is very similar to that of POMS, except the Confusion-Bewilderment factor which shows weak factor consistency in K-POMS. This may reflect some emotional characteristic of Koreans such as an undifferentiated aspect of cognitive efficiency. The sixth factor newly extracted from K-POMS also may be indicative of an unique emotional aspect of young Koreans.

  • PDF

A Study of Deconstruction in Clothing -Comparison of Clothing with Architecture- (복식에 나타난 해체주의 양식연구 -건축과 복식의 비교-)

  • 전혜정
    • Journal of the Korean Society of Costume
    • /
    • v.32
    • /
    • pp.293-312
    • /
    • 1997
  • Deconstructionism is a philosophical stream in the latter half of 20'th century which goes against western metaphysics and tries to deconstruct the dualism e.g. eastern/west-ern man/woman. Its main concepts are 'indi-vidual' 'other' 'difference' 'restoration of the repressed' 'decentralization' 'Today it shows strong influences in literature art, and other social fields. This study investigated inner meanings and exterior forms represented in clothing on the base of Jacques Derrida's theory in order to re-search modes of deconstruction in is. And it compared clothing with architecture among other genres of art in order to discover similarities between through and modes of art in a certain period. For illuminating concept of deconstruction I referred to the literatures of preceding studies and for deconstruction's characteristics in both clothing and architec-ture I referred work's collection book $\ulcorner$collec-tions$\lrcorner$ and other related books dealing from 1960's to this point. As a rsult there are four modes of decons-truction in both clothing and architecture as follows; 1) Differenance which is a concept of the dif-ference in time and space as being trace. 2) In termeaning of meanings which is not present in reality but re-interpreted a new in the future. 3) Interxtuality in which a texte is not alone but with others 4) Dis.De phenomenon in which distortion and fragmentation forms occur as the result of the denial of perfection and reson. There are characteristics of modes of de-construction in clothing as follows; 1) Differance; R.Gigli, P. Rabanne. G.Bersace, V.Westwood are representatives of the cloth-ing which is combined with the past the pres-ent and the future or is re-viewed as the clothing of the past in the present point of view. J. Watanabe R. Dawakubo I miyake are representatives of the clothing which is out-date but re-viewed in the sense of recollec-tion and re-usage. 2) Intermeaning of meanings: R. kawakubo I, Miyake Y,Yamamoto are representatives of the clothing which is incomplete but re-interpreted in the future and appears to be new-fashioned according to ways of bnding wearing throwing on and tying J.C. Castel-bajac K.Hamnett S.Sprouse are representa-tives of the clothing which is made up of ab -stract forms scribbling or symbolic letters which appears to be different according to view-point of observers. 3) Intertextuality ;J.P.Gaultier K.Hamnett, Comme des Gar ons are representatives of intertextuality of gender which avoids the 여-ality of man/woman J.P Gaultier G,Versace J. galliano are representatives of the intertex-tuality of time place and occasion which mixes temporality extensity and purposiveness. J.P Gaultier G,Versace are representatives of the intertextuality of coordination which combines items different in image purpose and use. P.Rabanne A,Courr ges R,Gernreic I,Miyake are representatives of the intertextuality of mat-ter which uses heterogeneous matter different from cloth. 4) Dis.De-phenomenon: R, Kawakubo I.Mi-yake J.P.Gaultier are representatives of the de-composition which discloses distortion and exag-geration of form through destructing the estab-lished way of construction J.Galliano R.Kawa-kubo Devota Y Lomba arte representatives of the decentring which restores the repressed and the alienated on the one hane and shows front-centrality on the other. Comme des Gar ones is representative of the discontinuity because of which right and left up and down are not in har-mony with one another. J,Galliano J.P,Gaultier T,Mugler are representatives of the disruption by way of which one makes one's body exposed through intentional slashes or holes. As a consequence deconstructionism enabled us to investigate similarities between through of deconstruction and modes of art interms of diffrance Intermeaning of meanings intertextuality and Dis De-phenomenon. And we found that deconstruction was a phase of development in that it as a all-comprising and multiple concept tries to pursue the new through deconstruction.

  • PDF

Biological Activities of Pharbitis nil and Partial Purification of Anticancer Agent from Its Extract (견우자의 생리활성 분석과 추출물로부터 항암 활성물질의 분리)

  • Choi, Hyeun Deok;Yu, Sun Nyoung;Park, Sul-Gi;Kim, Young Wook;Nam, Hyo Won;An, Hyun Hee;Kim, Sang Hun;Kim, Kwang-Youn;Ahn, Soon Cheol
    • Journal of Life Science
    • /
    • v.27 no.2
    • /
    • pp.225-232
    • /
    • 2017
  • This study aimed to evaluate several biological activities of Pharbitis nil and to isolate an anticancer agent from its methanol extract. Pharbitis nil seeds were extracted with methanol (PNM). Then, PNM was fractionated into solvent layers such as ethyl acetate fraction (PNE), butanol fraction (PNB), and water fraction (PNW). The biological activities of the fractions were analyzed for tyrosinase inhibition, lipase inhibition, DPPH-free radical scavenging, and cell growth inhibition. PNM showed strong growth inhibition of prostate cancer PC-3 cells. PNM was subjected to Diaion HP-20 and eluted stepwise with 50%, 80%, and 100% methanol. Then, for activity-guided fraction, each fraction was analyzed for growth inhibition of prostate cancer PC-3 cells by using an MTT assay. Because the 100% fraction showed significantly strong inhibitory activity, the fraction was further separated in the reverse phase C18, which was eluted with 80% and 90% methanol. The 90% fraction was further subjected to Sephadex LH-20 using a mobile solvent of 100% methanol. Finally, the compound PN was partially purified for HPLC analysis. PN showed cell growth inhibitory activity and induced the apoptosis and cell cycle arrest of prostate cancer PC-3 cells, as measured by flow cytometry. The results together suggest that Pharbitis nil possesses various biological activities, especially the inhibitory activity for the proliferation of prostate cancer PC-3 cells, suggesting the possibility of its use as an anticancer agent.