• Title/Summary/Keyword: V2C

Search Result 9,803, Processing Time 0.041 seconds

Synthesis and Characteristics of Partially Fluorinated Poly(vinylidene fluroide)(PVDF) Cation Exchange Membrane via Direct Sulfonation (직접술폰화반응에 의한 부분불소화 Poly(vinylidene fluroide)(PVDF) 양이온교환막의 합성 및 특성)

  • Kang, Ki Won;Hwang, Taek Sung
    • Membrane Journal
    • /
    • v.25 no.5
    • /
    • pp.406-414
    • /
    • 2015
  • In this study, partially fluorinated cation exchange membranes were prepared by direct sulfonation of Poly(VDF-co-hexafluoropropylene) copolymers (PVDF-co-HFP) followed by a casting method for application in the Membrane capacitive deionization (MCDI). The structure of sulfonated PVDF-co-HFP (SPVDF) was confirmed by Fourier-transform infrared (FT-IR) and $^1H$ Nuclear magnetic resonance ($^1H$ NMR) analysis. For quantitative analysis of the chemical composition, the X-ray Photoelectron Spectroscopy (XPS) was used. The membrane properties such as water uptake, ion exchange capacity and electrical resistance were measured. It was suggested that the optimum direct sulfonation condition of PVDF-co-HFP ion exchange membranes was $60^{\circ}C$ and 7 hours for temperature and duration of sulfonation, respectively. The water uptake of the SPVDF ion exchange membrane was 21.5%. The ion exchange capacity and electrical resistance were 0.89 meq/g and $3.70{\Omega}{\cdot}cm^2$, respectively. It was investigated that if it is feasible to apply these membranes in MCDI at various cell potentials (0.9~1.5 V) and initial flow rates (10~40 mL/min). In the MCDI process, the maximum salt removal rate was 62.5% in repeated absorption-desorption cycles.

Synthesis and Properties of Nonlinear Optical Polymer Derived from α-Methyl Styrene/Maleic Anhydride by Polymer Reaction (고분자 반응을 이용한 Maleic anhydride계 비선형 광학 고분자의 합성 및 전기광학 특성)

  • Park, Lee Soon;Keum, Chang Dae;Song, Jae Won;Kim, Kwang Taek;Kim, Gi Heon;Kang, Shin Won
    • Applied Chemistry for Engineering
    • /
    • v.9 no.5
    • /
    • pp.704-709
    • /
    • 1998
  • Non-linear optical polymer based on poly (${\alpha}$-methylstyrene-co-maleic anhydride) (MSMA) substrate polymer was prepared by polymer reaction method and its thermal and electro-optic properties were examined. In the polymer reaction between MSMA substrate polymer and 2-[4-(4-nitrophenylazo)-N-ethylphenylamino]ethanol (DR1) chromophore, the degree of substitution of DR1 into MSMA was higher with the 4-dimethylaminopyridine (DMAP) as catalyst and 3-dicyclohexyl carbodiimide (DCC) as dehydrating agent (sample, MSMA-DC) than the one with just 4-dimethylaminopyridine as catalyst (sample, MSMA-D). The synthesized NLO polymer (MSMA-DC) exhibited electro-optic coefficient of 18 pm/V (632.8 nm) and glass transition temperature ($T_g$) of about $175^{\circ}C$.

  • PDF

A Study on Selective Catalytic Reduction on Diesel Particulate Filter Catalyst and Coating Technology the Removal of Particulate Matters and NOx for Old Special Cargo Vehicles (노후 특수·화물 차량 PM/NOx 저감을 위한 SDPF 촉매 및 코팅 기술 연구)

  • Jeong, Kwanhyoung;Seo, Philwon;Oh, Hungsuk;Kim, Jongkook;Kang, Soyeon;Kang, Jeongho;Kim, Hyunjun;Shin, Byeongseon
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.695-699
    • /
    • 2021
  • In this study, Selective Catalytic Reduction on Diesel Particulate Filter (SDPF) after-treatment system was introduced to simultaneously remove NOx and Particulate Matters (PM) emitted from trucks and special cargo vehicles using old engine. First, in order to select an Selective Catalytic Reduction (SCR) catalyst for SDPF, the de-NOx performance of V/TiO2 and Cu-Zeolite catalysts were compared, and the SCR catalyst characteristics were analyzed through Brunauer Emmett Teller (BET), X-ray Diffraction (XRD) and NH3-TPD (Temperature Programmed Desorption). From the activity test results, the Cu-zeolite catalyst showed the best thermal stability. For optimal coating of SDPF, slurry was prepared according to the target particle size. From the coating stability and back pressure test results of SDPF according to the amount of SCR coating, As a result of comparing coating stability, back pressure, and de-NOx performance by producing A, B, and C samples for each loading amount of the SDPF catalyst, the best results were found in the B sample. The engine dynamometer test was conducted for the optimal SDPF after-treatment system, and the test results satisfied Eu-5 regulations.

The association of vitamin D and urine microalbumin/creatinine and obesity in Korean adults (한국 여성에서 혈청 ferritin과 25-hydroxyvitamin D 및 대사 증후군의 관련성)

  • Choi, Jung-Hun;Kim, Sung-Gil;Eun, Sung-Jong;Song, Mi-Ok
    • Journal of the Health Care and Life Science
    • /
    • v.9 no.1
    • /
    • pp.161-167
    • /
    • 2021
  • The present study was conducted to assess the association between serum ferritin and 25-hydroxyvitamin D [25(OH)D] and metabolic syndrome (MetS) in Korean women. The data of a total of 9,256 adults (4,196 premenopausal women and 4,340 postmenopausal women) aged ≥ 20 years from the Fifth Korean National Health and Nutrition Examination Survey (KNHANES V) (2010-2012) were analyzed. The key study results were as follows: First, in women without MetS, after adjusting for related variables (age, smoking, alcohol consumption, regular exercise, SBP, DBP, WM, TC, TGs, HDL-C, FPG, Hb, Hct, and Fe), vitamin D status was positively associated with serum ferritin levels (premenopausal, p < 0.001; postmenopausal, p = 0.027). Second, in women with MetS, after adjusting for related variables, vitamin D status was not associated with serum ferritin levels (premenopausal, p = 0.739; postmenopausal, p = 0.278). In conclusions, vitamin D status was positively associated with serum ferritin levels in women without MetS but not in women with MetS.

Area Classification of Hazardous Gas Facility According to KGS GC101 Code (KGS GC101을 통한 가스시설 폭발위험장소의 설정)

  • Kim, Jeong Hwan;Lee, Min-Kyung;Kil, Seong-Hee;Kim, Young-Gyu;Ko, Young Kyu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.46-64
    • /
    • 2019
  • Technical practice code, KGS GC101 2018, for explosion hazard area selection and distance calculation of gas facility was enacted and implemented from July 12, 2018. This code includes whole contents of IEC60079-10-1 2015 (Explosive atmospheres Part 10-1: Classification of areas - Explosive gas atmospheres), and clarifies the interpretation of ambiguous standards or adds guidelines for standards. KGS GC101 is a method for classifying explosion hazard place types: (1) Determination of leak grade (2) Determination of leakage hole size (3) Determination of leakage flow (4) Determination of dilution class (5) Determination of ventilation effectiveness, finally (6) Determination of danger place (7) Explosion The range of dangerous places can be estimated. In order to easily calculate this process, the program (KGS-HAC v1.14, C-2018-020632) composed by Visual Basic for Application (Excel) language was produced by Korea Gas Safety Corporation. We will discuss how to use codes and programs to select and set up explosion hazard zones for field users.

Relationship between Corrosion in Reinforcement and Influencing Factors Using Half Cell Potential Under Saturated Condition (습윤 상태에서의 반전위를 이용한 철근 부식과 영향 인자 간의 상관성 분석)

  • Jeong, Gi-Chan;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.191-199
    • /
    • 2021
  • In this study, the correlation between the influencing factors on corrosion and Half Cell Potential(HCP) measurement was analyzed considering the three levels of W/C ratio, cover depth, and chloride concentration. The HCP increased with enlarged cover depth, so it was confirmed that the increment of cover depth was effective for control of corrosion. Based on the criteria, the case of 60mm cover depth showed excellent corrosion control with under -200mV, indicating increase of cover depth is an effective method for reducing intrusion of external deterioration factors. When fresh water was injected to the upper part of specimens, very low level of HCP was monitored, but in the case that concentrations of chloride were 3.5% and 7.0%, HCP dropped under -200mV. In addition, the case with high volume of unit binder showed lower HCP measurement like increasing cover depth. Multiple regression analysis was performed to evaluate the correlation between the corrosive influence factors and HCP results, showing high coefficient of determination of 0.97. However, there were limitations such as limited number of samples and measuring period. Through the additional corrosion monitoring and chloride content evaluation after dismantling the specimen, more reasonable prediction can be achieved for correlation analysis with relevant data.

Evaluation of CPTu Cone Factors for Busan Clay Using Pore Pressure Ratio (간극수압비를 이용한 부산점토의 CPTu 콘계수 추정)

  • Hong, Sung-Jin;Lee, Moon-Joo;Kim, Tai-Jun;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.1
    • /
    • pp.77-88
    • /
    • 2009
  • Cone factors, $N_{kt}$, $N_{ke}$ and $N_{{\Delta}u}$, for estimating undrained shear strength of Busan clay are evaluated in this study. For this, CPTu and field vane tests are performed for clay layers at two sites, Busan new-port and Noksan, and also $CK_0U$ triaxial tests with undisturbed samples taken from the same site are carried out. From experimental results, it is observed that the undrained shear strengths of clay increases with depth, and the undrained shear strength obtained from triaxial tests is 1.5 times higher than one obtained from vane tests. The normalized undrained shear strengths of Busan clay from triaxial and vane shear tests are $0.26{\sim}0.44$ and $0.20{\sim}0.23$, respectively. In CPTu results, cone tip resistance ($q_c$) and pore pressure ($u_2$) linearly increase with depth, and the pore pressure ratio ($B_q$) of Busan clay is within the range of $0.3{\sim}1.0$. The cone factors, which are determined by comparing the CPTu results with $CK_0U$ triaxial and vane shear test results, are found to be $5{\sim}20$ and $10{\sim}35$, respectively. It is also observed that the cone factors are inversely proportional to the pore pressure ratio. From this, the prediction methods for evaluating the cone factors of Busan clay are developed.

Analysis of coenzyme Q10 in human plasma by high performance liquid chromatography (고성능액체크로마토그라피를 이용한 혈장 내 코엔자임 큐텐 분석)

  • Park, Yong-Sun;Park, Sang-Boem;Song, Sean-Mi;Kim, Yong-Woo;Lee, Kyoung-Ryul
    • Analytical Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.514-518
    • /
    • 2009
  • Coenzyme $Q_{10}$($CoQ_{10}$), a vitamin E-like substance, represents a components of the complex antioxidant system of the human organism. $CoQ_{10}$ levels in human plasma were determined by high performance liquid chromatography (HPLC) with UV detection. It was dissociated from lipoproteins by methanol and extracted into n-hexane with liquid-liquid extraction procedure, after centrifugation, the supernatant was dried under nitrogen gas stream. The residue was dissolved in the absolute ethanol. Determination of $CoQ_{10}$ was performed on a $C_{18}$ reversed-phase analytical column with ultraviolet detection at 275 nm and the mobile phase containing 15% (v/v) ethanol in methanol at a flow rate of 1.7 mL/min. The low limit of quantitation was 0.02 mg/L (S/N=10), the linearity between the concentration and peak height is from 0.1 to 2.0 mg/L. Twenty-four randomly selected plasma samples from apparently healthy, 27 to 44 year old individuals (males and females) were analyzed for total $CoQ_{10}$. The average level in these subjects was $0.62{\pm}0.13mg/L$ with the range of 0.41-0.98 mg/L. This method has a specific and a sufficient limit of quantitation (LOQ) for analysis of $CoQ_{10}$ in human plasma in both a clinical study and research at laboratories.

Regional Differences in Voltage-tension Relationship of Gastric Smooth Muscles in Guinea-pig (위 평활근의 부위별 전압-장력 관계에 관한 연구)

  • Kim, Ki-Whan;Lee, Sang-Jin;Suh, Suk-Hyo
    • The Korean Journal of Physiology
    • /
    • v.23 no.2
    • /
    • pp.263-275
    • /
    • 1989
  • Mechanical contractions and electrical activities of the fundic longitudinal and antral circular muscle fibers were investigated in order to elucidate topical differences of gastric motility. K-induced contracture was produced by exposure of muscle strips to high K Tyrode solution. Membrane potential and mechanical contraction were simultaneously recorded by conventional glass microelectrode method and single sucrose-gap technique. All experiments were performed in tris-buffered Tyrode solution which was aerated with $100%\;O_2\;and\;kept\;35^{\circ}C$. The results obtained were as follows: 1) The resting membrane potential of circular muscle cells in the antral region was about 10 mV more negative than that in the fundic region. 2) The membrane potentials decreased almost linearly as the extracellular KCI concentration was increased both in antral circular muscle cells and in fundic longitudinal muscle cells. 3) The thresholdal K concentration of K-contracture was 15 mM (membrane potential, -48 mV) for the antral circular muscle strip and 20 mM for the fundic longitudinal muscle cells. 4) The ratio of membrane permeability coefficient for $Na^+\;and\;K^+,\;P_{Na}/P_K\;({\alpha})$ was 0.065 for antral circular muscle cells and was 0.108 for fundic longitudinal muscle cells. 5) K-contracture of antral and fundic smooth muscle strips showed the contracture composed of phasic and tonic components. The amplitude of the phasic component increased sigmoidally in a dose-dependent manner, whereas that of the tonic component was maximal at a concentration of 40 mM KCI and at the concentrations above or below 40 mM KCI the amplitude was reduced. 6) The inverse relationship between the amplitude of tonic component and extracellular KCI concentration in the range of 40 to 150 mM KCI was more prominent in the antral circular muscle strip than in the fundic longitudinal muscle strip, where the amplitude of the tonic component decreased less steeply and was maintained higher at the same high K concentrations. 7) The tonic component was totally dependent on the external $Ca^{2+}$ and completely abolished by verapamil, while tile phasic component was far less dependent on the external $Ca^{2+}$ and partially suppressed by verapamil. From the above results, the following conclusions could be made. 1) The phasic component of K-contracture is produced both by intracellular $Ca^{2+}$ mobilization and by $Ca^{2+}$-influx from outside, while the tonic component is generated and maintained by the $Ca^{2+}-influx$ through the potential-dependent $Ca^{2+}$ channel. 2) The mechanism of reducing the free $Ca^{2+}$ concentration in the myoplasm seems to be more developed in the antral circular muscle than in the fundic longitudinal muscle. 3) The lower resting membrane potential of the fundic longitudinal muscle cell reflects a relatively high $P_{Na}/P_K$ ratio of about 0.108.

  • PDF

Purification and Characterization of Acidic Chitinases from Gizzards of Broiler (Gallus gallus L.)

  • Han, Beom-Ku;Moon, Jong-Kook;Ryu, Yeon-Woo;Park, Yun-Hee;Jo, Do-Hyun
    • BMB Reports
    • /
    • v.33 no.4
    • /
    • pp.326-331
    • /
    • 2000
  • Acidic chitinases from the gizzards of a broiler were purified to homogeneity, using precipitation with $(NH_{4})_{2}SO_{4}$, ion exchanger chromatography, gel filtration, chromatofocusing and hydrophobic interaction chromatography. The enzymes, GAC1 and GAC2, were purified 180- and 194- folds with a recovery of 4.9% and 2.7%, respectively. The molecular mass of GAC1 and GAC2 were 48.2 kDa and 57.8 kDa, respectively. Chromatofocusing resulted in a pI of 3.1 for both enzymes. The purified enzymes were endochitinases that were devoid of ${\beta}-N-acetylglucosaminidase$ and lysozyme activity. Kinetic studies using $[^3H]chitin$ indicate that GAC1 has a $K_m$ and $V_{max}$ of 1.97 mg/ml and 185 mg/mg protein/h, respectively. The GAC2 has a $K_m$ and $V_{max}$ of 0.42 mg/ml and 92.3 mg/mg protein/h, respectively at optimal pH and temperature (pH 5.0 and $60^{\circ}C$). When the pentamer and hexamer of N-acetylglucosamine (GlcNAc) were used as a substrate, the major product by GAC1 was the dimer of GlcNAc with a differential accumulation of the monomer and trimer, depending upon the substrate. However, the GAC2 produced the dimer and trimer in an equal quantity, regardless of the substrate used. The first 9 $NH_2-terminal$ amino acid residues of the purified gizzard chitinase GAC1 and GAC2 shared a 100% homology. The first 25 $NH_2-terminal$ amino acid residues of GAC1 also shared 55-60% homology with animal chitinases and some animal proteins, such as whey protein and oviduct-specific proteins. However, little homology was found with either microbial and plant chitinases, or egg white lysozyme.

  • PDF