Enrofloxacin is one of the second-generation quinolones which have been widely used to treat bacterial infections in various species including chicken, pig, horse and cattle. The objective of the present study was to describe the serum bactericidal activity(SBA) of enrofloxacin, its pharmacokinetic behaviors after intramuscular or intravenous administration to Korean native goats in the dose rate of 5mg/kg b.w. The results obtained through this study were as follows : 1. Sera collected from both sexes of Korean native goats administered 5mg/kg i.v. or i.m. showed potent antibacterial activities up to the 12 hours by way of the serum bactericidal activity. 2. Concentrations of enrofloxacin in the biological samples were measured by high-performance liquid chromatography(HPLC) so as to study pharmacokinetic characteristics. For detection of enrofloxacin, 10% TCA was optimal for protein precipitation and the mobile phase was 0.01M citric acid/methanol/acetonitrile(7/2/1, pH 3.5) with solid phase being the $C_{18}$ reversephase column and detection wavelength being 278nm. The limit of detection of enrofloxacin on HPLC was $0.05{\mu}g/ml$. 3. Pharmacokinetic profile of enrofloxacin administered 5mg/kg i.v. in Korean native goats was best described by two-compartment open model and that administered i.m. the same rate by one-compartment model. There were no sex differences in pharmacokineticl parameters. In conclusion, enrofloxacin showed potent in vivo antibacterial activity and excellent pharmacokinetic properties in Korean native goats, hence it may be used as a potential antibacterial in the veterinary clinical settings.
반사방지막은 태양전지 표면에서의 광 반사를 낮춰주며, Si wafer 표면에서의 carrier의 재결합을 줄이는 passivation 역할을 한다. 이를 위한 다양한 물질이 반사방지막으로 사용된다. 단일박막은 passivation 효과가 미미하여 최근 passivation 향상에 도움이 되는 이중구조 반사방지막이 널리 연구되어지고 있다. 하지만 물질이 다양해짐에 따라 공정시간 및 비용이 늘어나고, passivation에 최적화된 물질사용이 필수적으로 요구되는 단점이 있다. 따라서 본 연구에서는 기존에 passivation 효과가 뛰어나다고 알려진 SiNx의 굴절률 가변을 통하여 이중구조를 갖는 박막을 반사방지막으로 이용하여 그 특성을 비교, 분석하였다. SiNx 이중반사방지막은 0.8 Torr~1 Torr의 압력에서 $450^{\circ}C$의 기판온도로 PECVD를 이용하여 증착되었으며 이때의 plasma power는 180mW/$cm^2$으로 고정 하였다. 굴절률 1.9 및 2.3을 갖는 가스 조성비를 이용하여 각 layer의 두께를 20/60nm, 30/50nm, 40/40nm로 가변하였다. 샘플 제작 후 Sun-Voc 측정을 통하여 implied Voc 및 효율을 측정하였다. 단일반사방지막을 사용한 샘플의 경우 608mV의 implied Voc가 측정되었으며, FF는 82.8%, 효율은 17.6%로 측정되었다. 가장 우수한 특성을 나타낸 20/60nm의 두께로 증착된 샘플의 경우 implied Voc는 625mV, FF는 84.1%, 효율은 18.3%로 우수한 결과를 나타내었다. 반사도 측정 결과 단일반사방지막은 2.27%로 높았으나 SiNx 이중구조를 이용한 반사방지막은 1.67%로 낮은 값을 확인 하여 이중구조의 반사방지막이 반사도 저감 및 passivation 효과 향상에 도움이 되는 것을 확인할 수 있었다.
결정질 실리콘 태양전지의 효율을 향상시키기 위하여 수광면에 서로 다른 도핑농도를 가지는 고농도 도핑영역과 저농도 도핑영역으로 이루어진 emitter를 형성하는 것이 요구되며 이를 selective emitter라 칭한다. Selective emitter를 형성하면 고농도 도핑영역에서 금속전극과 저항 접촉이 잘 형성되기 때문에 직렬 저항이 최소화되고 저농도 도핑영역에서는 전하 재결합의 감소로 인하여 태양전지의 변환효율이 상승하는 이점이 있다. Selective emitter의 형성방법은 이미 다양한 방법이 제안되고 있으나, 본 연구에서는 기존에 제시된 방법과는 다르게 열산화 시 dopant redistribution에 의한 Boron depletion 현상을 이용하여 selective emitter를 형성하는 방법을 제안하였고, 이를 Simulation을 통하여 검증하였다. 초기 emitter 확산 후 junction depth는 0.478um, 면저항은 $104.2{\Omega}/sq.$ 이었으며, nitride masking layer 두께는 0.3um로 설정하였다. $1100^{\circ}C$에서 30분간 습식산화 공정을 거친 후 nitride mask가 있는 부분의 junction depth는 1.48um, 면저항은 $89.1{\Omega}/sq$의 값을 보였고, 산화막이 형성된 부분의 junction depth는 1.16um, 면저항은 $261.8{\Omega}/sq$의 값을 보였다. 위 조건의 구조를 가진 태양전지의 변환 효율은 19.28%의 값을 나타내었고 Voc, Jsc 및 fill factor는 각각 645.08mV, $36.26mA/cm^2$, 82.42%의 값을 보였다. 한편 일반적인 구조로 설정한 태양전지의 변환 효율, Voc, Isc 및 fill factor는 각각 18.73%, 644.86mV, $36.26mA/cm^2$, 80.09%의 값을 보였다.
Journal of the Institute of Electronics Engineers of Korea SD
/
v.40
no.2
/
pp.111-116
/
2003
In this paper, a CMOS baseband analog receiver for wireless home network is discussed. It is composed of a Gilbert type mixer, an Elliptic 6th order 1ow pass filter, and a 6-bit A/D converter. The main role of the mixer is generating a mixed analog signal between the 200MHz output signal of CMOS RF stage and the 199MHz local oscillator. After the undesired high frequency component of the mixed signal comes out. Finally, the analog signal is converted into digital code at the 6-bit A/D converter, The proposed receiver is fabricated with 0.25${\mu}{\textrm}{m}$ 1-poly 5-metal CMOS technology, and the chip area is 200${\mu}{\textrm}{m}$ X1400${\mu}{\textrm}{m}$. the receiver consumes 130㎽ at 2.5V power supply.
Journal of the Korean Institute of Telematics and Electronics A
/
v.32A
no.2
/
pp.89-95
/
1995
The structure of boron ion-implanted pn junctio in the vacancy-doped p-type HgCdTe was investigated with the differential Hall measurement. The as-implanted junction showed the electron concentration as high as 1${\times}10^{18}/cm^{3}$ and the junction depth of 0.6.mu.m. When the HgCdTe junction was heated in oven, the electron concentration near the junction decreased and the junction depth increased as the annealing temperature and time increased. The junction structure after the thermal annealing was n$^{+}$/n$^{-}$/p. For the 200.deg. C 20min annealed sample, the electron mobility was 10$^{4}cm^{2}/V{\cdot}$s near the surface(n$^{+}$), and was larger thatn 10$^{5}cm^{2}/V{\cdot}$s near the junction(n$^{+}$). The junction formation mechanism is conjectured as follows. When HgCdTe is ion-implanted, the ion energy generates crystal defecis and displaced Hg atoms HgCdTe is ion-implanted, the ion energy generates crystal defecis and displaced Hg atoms near the surface. The displaced Hg vacancies diffuse in easily by the thernal treatment and a fill the Hg vacancies in the p-HgCdTe substrate. With the Hg vacancies filled completely, the GfCdTe substrate becomes n-type because of the residual n-type impurity which was added during the wafer growing. Therefore, the n$^{+}$/n$^{-}$/p regions are formed by crystal defects, residual impurities, and Hg vacancies, respectively.
Kim, Hyung-Rae;Park, Sang-Hune;Jang, Young-Chan;Jung, Sun-Y;Kim, Ted;Park, Hong-June
Proceedings of the IEEK Conference
/
2005.11a
/
pp.777-780
/
2005
모바일 오디오 적용을 위한 저전력 ${\Sigma}{\Delta}$ Modulator 에 대한 설계와 layout 을 보였다. 전체 구조는 3 차 단일 피드백 루프이며, 해상도는 16bit 을 갖는다. 샘플링 주파수에 따른 Over-sampling Ratio 는 128(46kHz) 또는 64(96kHz) 가 되도록 하였다. 차동 구조를 사용한 3 차 ${\Sigma}{\Delta}$ modulator 내의 적분기에 사용된 Op-Amp 는 DC-Gain 을 높이기 위해서 Gain-boosting 기법이 적용되었다. ${\Sigma}{\Delta}$ modulator 의 기준 전압은 전류 모드 Band-Gap Reference 회로에서 공급이 되며, PVT(Process, Voltage, Temperature) 변화에 따른 기준 전압의 편차를 보정하기 위하여, binary 3bit 으로 선택하도록 하였다. DAC 에서 사용되는 단위 커패시터의 mismatch 에 의한 성능 감소를 막기 위해, DAC 신호의 경로를 임의적으로 바꿔주는 scrambler 회로를 이용하였다. 4bit Quantizer 내부의 비교기 회로는 고해상도를 갖도록 설계하였고, 16bit thermometer code 에서 4bit binary code 변환시 발생하는 에러를 줄이기 위해 thermometer-to-gray, gray-to-binary 인코딩 방법을 적용하였다. 0.18um CMOS standard logic 공정 내 thick oxide transistor(3.3V supply) 공정을 이용하였다. 입력 전압 범위는 2.2Vp-p,diff. 이며, Typical process, 3.3V supply, 50' C 시뮬레이션 조건에서 2Vpp,diff. 20kHz sine wave 를 입력으로 할 때 SNR 110dB, THD 는 -95dB 이상의 성능을 보였고, 전류 소모는 6.67mA 이다. 또한 전체 layout 크기는 가로 1100um, 세로 840um 이다.
In this work, Pd/Pt gate MISFET sensor using Pd membrane was fabricated to detect the hydrogen in DI water. A differential pair-type was used to minimize the intrinsic voltage drift of the MISFET. To avoid hydrogen induced drift of the sensor, the silicon dioxide/silicon nitride double layer was used as the gate insulator of the FET's. In order to eliminate the blister formation on the surface of the hydrogen sensing gate metal, Pd/Pt double metal layer was deposited on the gate insulator. For this type of application sensors need to be isolated from the DI water, and a Pd membrane was used to separate the sensor from the DI water. The output voltage change due to the variation of hydrogen concentration is linear from 100ppm to 500 ppm.
The objective of the present investigation was to study pharmacokinetics of promethazine in Korean healthy subjects using a validated HPLC method. The HPLC analysis was performed on a Capcell Pak CN column with a mixture of acetonitrile-0.02M potassium dihydrogen phosphate (42:58, v/v, pH 6.0) and the analyte was quantified with UV detection at 251 nm. The calibration curve of the drug was linear over the range of 1-40ng/mL in human serum and the limit of quantification (LOQ) was 1 ng/mL. This analytical method was validated and shown to be specific, accurate, precise and reproducible. This method was applied to pharmacokinetic study of promethazine in Korean healthy volunteers following an oral administration of two 25 mg Himazin tablets (50 mg promethazine ${\cdot}$HCI) after overnight fasting. Serum samples were collected at given intervals over a 36-hour period (12 points) and pharmacokinetic parameters were determined from serum concentration-time profile using WinNonlin program. The estimated $AUC_{0__\infty}$, $AUC_{0_\infty}$, $C_{max}$, $T_{max}$ and $t_{1/2}$ of promethazine obtained from Korean healthy subjects were 103.84 ${\pm}$84.30 ng${\cdot}$hr/mL, 87.94${\pm}$81.02 ng${\cdot}$hr/mL, 13.43${\pm}$10.92 ng/mL, 2.00${\pm}$1.16 hr and 5.88${\pm}$3.47 hr, respectively.
Background: An increasing number of elderly are referred for open heart surgeries(OHS). These patients are assumed to have significantly increased morbidity and mortality because of compromised functional reserves in their vital organs. We reviewed the results of OHS patients who were 70 years old or older. Material and Method: Thirty six consecutive septuagenarians underwent OHS from 1995 to 1997. Operations were coronary artery bypass grafting(CABG) in 26 including 3 left main surgical angioplasty, valve replacement in 7, MVR+CABG in 2, and ASD closure+TAP in 1. Statistical tests were carried out to compare survivor group with nonsurvivor group in respect to risk factors including NYHA functional class, LVEF, emergent operation, IABP support, CPB/ACC time, ventilator time cardiac index, ICU stay and hospital stay for operative mortality. Result: Operative mortality rate and postoperative complication were 16%(6/36) and 50%(18/36). One-year and 3-year actuarial survival rates were 76%. Nine patients(25%) had major complications including third-degree A-V block(2), respiratory failure(1), stroke(3), renal failure requiring dialysis(3) and postoperative hemorrhage(2). The causes of death were pneumonia(1), bleeding(1), acute renal failure(1), low cardiac output(1), third-degree A-V block(1), and ventricular tachycardia(1). The univariate analysis of mortality shows that NYHA class IV, LVEF<40%, lesser values for C.I, and longer time for ventilatory support were associated with the risk factors(p value=0.03, 0.001, 0.007, and 0.014). The emergent operation, CPB/ACC time, IABP support, ICU stay and hospital stay were not significant. Conclusion: We conclude that cardiac operation can be performed in septuagenarians with acceptable outcomes when done in patients with normal to moderately depressed left ventricular function and adequate functional reserves in their vital organs.
Kim, Ghee-Hwan;Kim, Won;Kim, Jin-Sung;Jin, Qingri;Kang, Won-Ku;Lee, Jong-Hwa;Ha, Jung-Heun;Jeong, Eun-Ju
Journal of Pharmaceutical Investigation
/
v.37
no.3
/
pp.179-186
/
2007
A simple, sensitive and selective liquid chromatographic/tandem mass spectrometric method (LC-MS/MS) was developed and validated for doxifluridine and 5-fluorouracil (5-FU) quantification in dog heparinized plasma. Sample preparation was based on liquid-liquid extraction using a mixture of isopropanol/ethyl acetate (1/9 v/v) to extract doxifluridine, 5-FU and 5-chlorouracil (5-CU, an internal standard) from plasma. Chromatography was performed on a C-18 analytical column and the retention times were 2.7, 1.5 and 1.7 min for doxifluridine, 5-FU and 5-CU, respectively with shorter analysis time within 5 min than previously reported methods. The ionization was optimized using ESI negative mode and selectivity was achieved by tandem mass spectrometric analysis by multiple reaction monitoring (MRM) using the transformations of m/z 244.8>107.6, 129.0>42.0 and 144.9>42.1 for doxifluridine, 5-FU and 5-CU, respectively. The achieved low limit of quantification was 20.0 ng/mL and the assay exhibited linear range of 20-2000 ng/mL ($R^2>0.99957$ for doxifluridine and $R^2>0.99857$ for 5-FU), using $100{\mu}L$ of plasma. Accuracy and precision of quality control samples for both doxifluridine and 5-FU met KFDA and FDA Guidance criteria of 15% for accuracy with coefficients of variation less than 15%. This method demonstrated adequate sensitivity, specificity, accuracy, precision and stability to support the simultaneous analysis of doxifluridine and 5-FU in dog plasma samples in pharmacokinetic and bioequivalence studies.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.