• Title/Summary/Keyword: V2C

Search Result 9,802, Processing Time 0.046 seconds

A Study on the Underdrainage of wet paddy fields by using P.V.C Pipe (P.V.C관을 이용한 저혼답의 이순작에 관한 연구)

  • 주재홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.2
    • /
    • pp.3002-3006
    • /
    • 1973
  • The study on the drainage has been performed for long time in Korea. The 4th attempt of study on under-drainage by use P.V.C. suction pipe were made in 1971. Drainage method, soil temperature, growth of crop and yield were observed and compared with the 3 drained Plots and at the 3 undrained ones. Obtained results were as follows; 1. The soil temperatures in the drained plots were $1.8^{\circ}C$ higher than that in the undrained ones during the irrigation period. 2. 20% of increased yield were resulted from practicing of P.V.C. suction pipe drainage. 3. The annual net income per 1ha of paddy rice field with P.V.C. suction pipe drainge was 82,900 won.

  • PDF

Clinical study on C.V.A patients in Hospital attached to college of oriental medicine and N.M.C. department oriental medicine (대학부속한방병원 및 국립의료원 한방진료부 뇌졸증환자에 대한 한방치료 현황 분석)

  • Shin, Hyun-Kyoo
    • Korean Journal of Oriental Medicine
    • /
    • v.1 no.1
    • /
    • pp.1-14
    • /
    • 1995
  • The clinical study was carried out on 1737 cases of inpatient and outpatient which have been diagnosed as C.V.A at hospital attached to 8 colleges of oriental medicine in Korea or National Medical Center from January 1st 1994 to December 31st 1994. The results were as follows; 1. In this study, the case of Occlusive C.V.D was 70.1%, Cerebral hemorrhage was 20.5%, Transient ischemic attack (T.I.A) was 5.3%, Subdural hemorrhage was 3.0%, Subarachnoid hemorrhage was 0.8% 2. It was confirmed by C.T (20%), E.K.G. (19%), X-ray (19%), Urinalysis (19%), Hematoscopy (20%). 3. The mean days of hospital treatment was 27.88 days, mean days of ambulation was 70.34 days. The mean days of hospital treatment of Occlusive C.V.D, Cerebral hemorrhage, T.I.A., Subdural hemorrhage, Subarachnoid hemorrhage were 25.79, 39.32, 12.49, 16.23, 23.40 days, respectively. The mean days of ambulation of Occlusive C.V.D, Cerbral hemorrhage, T.I.A., Subdural hemorrhage, Subarachnoid hemorrhage were 74.40, 93.68, 69.10, 29.75, 32.57 days, respectavely. 4. Oriental medical treatment of C.V.A was mainly Acupuncture (25%), Paper of Chinese herbs (22%), Chinese physiotherapy (14%), Extract of Chinese herbs (11%). 5. Oriental medical physiotherapy for C.V.A was mostly E.S.T., Kinesiatrics, electric negative therapy, others Aerohydrotherapy, interferential current therapy (I.C.T.), Carbon, Samhogi, T.E.N.S., Ultra-sound, Infra-red, Microwave, T.D.P., Ultraviolet, S.S.P., Chinese herbs beth, Prarffin bath, Magnetic treatment and tractions.

  • PDF

Electrical Characteristics of Organic Thin Film Transistors with Dual Layer Insulator on Plastic Substrates (이중 절연막 구조를 가전 플라스틱 유기 박막트랜지스터의 전기적 특성)

  • 최승진;이인규;박성규;김원근;문대규
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.194-197
    • /
    • 2002
  • Applying dual layer insulator on plastic substrates improved electrical characteristics of organic thin film transistor(TFT). A high-quality silicon dioxide(SiO$_2$) suitable for a insulator was deposited on plastic substrates by e-beam evaporation at 110$^{\circ}C$. The insulator film which was treated by N$_2$ annealing at 150$^{\circ}C$ showed excellent I-V, C-V characteristics. The dual layer insulator structure of polyimide-SiO$_2$ improved the roughness of SiO$_2$ surface and showed very low leakage current. In addition, the flat band voltage has been reduced from -2.5V to about 0.5V.

  • PDF

NO REDUCTION PROPERTY OF Pt-V2O5-WO3/TiO2 CATALYST SUPPORTED ON PRD-66 CERAMIC FILTER

  • Kim, Young-Ae;Choi, Joo-Hong;Bak, Young-Cheol
    • Environmental Engineering Research
    • /
    • v.10 no.5
    • /
    • pp.239-246
    • /
    • 2005
  • The effect of Pt addition over $V_2O_5-WO_3/TiO_2$ catalyst supported on PRO-66 was investigated for NO reduction in order to develop the catalytic filter working at low temperature. Catalytic filters, $Pt-V_2O_5-WO_3/TiO_2/PRD$, were prepared by co-impregnation of Pt, V, and W precursors on $TiO_2$-coated ceramic filter named PRD (PRD-66). Titania was coated onto the pore surface of the ceramic filter using a vacuum aided-dip coating method. The Pt-loaded catalytic filter shifted the optimum working temperature from $260-320^{\circ}C$(for the catalytic filter without Pt addition) to $190-240^{\circ}C$, reducing 700 ppm NO to achieve the $N_x$ slip concentration($N_x\;=\;NO+N_2O+NO_2+NH_3$) less than 20 ppm at the face velocity of 2 cm/s. $Pt-V_2O_5-WO_3/TiO_2$ supported on PRD showed the similar catalytic activity for NO reduction with that supported on SiC filter as reported in a previous study, which implies the ceramic filter itself has no considerable interaction for the catalytic activity.

Effect of Sintering Temperature on Electrical Stability of $Pr_{6}O_{11}$-Based ZnO Varistors ($Pr_{6}O_{11}$계 ZnO 바리스터의 전기적 안정성에 소결온도의 영향)

  • 남춘우;류정선
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.8
    • /
    • pp.640-646
    • /
    • 2001
  • The electrical stability for DC stress of Pr$_{6}$O$_{11}$-based ZnO varistos consisting of ZnO-Pr$_{6}$O$_{11}$-CoO-Cr$_2$O$_3$-Er$_2$O$_3$-based ceramics were investigated with sintering temperature in the range of 1325~1345$^{\circ}C$. A the sintering temperature is raised, the nonlinear exponent of varistors was decreased, whereas the stability was markedly improved. The density of ceramics was found to greatly affect the electrical stability for DC stress. The varistors sintered at 13$25^{\circ}C$ were completely degraded because of thermal runaway attributing to low density. The varistors sintered at 1335$^{\circ}C$ exhibited the highest nonlinearity, with a nonlinear exponent of 70.53 and a leakage current of 1.92$\mu$A, whereas they did not exhibit relatively high stability. On the contrary, the varistors sintered at >134$0^{\circ}C$ exhibited not only a high nonlinearity marking the nonlinear exponent above 50 and the leakage current below 3$\mu$A, but also a high stability marking the variation rate of the varistor voltage below 2%, even under DC stress such as (0.80V$_{1mA}$/9$0^{\circ}C$/12h)+(0.85V$_{1mA}$/115$^{\circ}C$/12h)+(0.90V$_{1mA}$/12$0^{\circ}C$/12h)+(0.95V$_{1mA}$/1$25^{\circ}C$/12h)+(0.95V$_{1mA}$/15$0^{\circ}C$/12h). In particular, ti was found that the varistors sintered at 134$0^{\circ}C$ were more nonlinear and more stable, compared with that of 1345$^{\circ}C$.EX>.}C$.EX>.

  • PDF

Norovirus Quantification in Oysters Crassostrea gigas Collected from Tongyeoung, Korea (통영시 연안의 양식굴(Crassostrea gigas)에서 검출된 노로바이러스의 정량분석)

  • Shin, Soon Bum;Oh, Eun-Gyoung;Lee, Hee-Jung;Kim, Yeon Kye;Lee, Tae Seek;Kim, Ji-Hoe
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.47 no.5
    • /
    • pp.501-507
    • /
    • 2014
  • Norovirus (NoV) is a major cause of food poisoning outbreaks in Korea. Most NoV outbreaks originate from environmental contamination, but bivalves such as oysters are also important vectors. Oyster Crassostrea gigas contamination by NoV has been reported in Korea, but no quantitative analyses of NoV have been performed. We investigated the NoV concentration in 21 oyster samples from a Korean commercial oyster-growing area with confirmed fecal contamination from January to December 2012, using real-time reverse transcription-polymerase chain reaction. Additionally, we assessed the NoV concentration after heating to investigate the effects of heat treatment on NoV-infected oysters. In NoV-positive samples, the cycle threshold (Ct) values were 37.43-39.41 and 36.77-39.30, while viral concentrations were $8.97{\times}10^2-2.24{\times}10^2$ and $3.05{\times}10^2-7.47{\times}10^1$ copies/g for genogroups I and II, respectively. After heat treatment, NoV genogroup I decreased by 83.4%, 88.0%, 89.4% and 100% at $60^{\circ}C$, $68^{\circ}C$, $70^{\circ}C$, and $100^{\circ}C$, respectively, for 15 min, while genogroup II respectively decreased by 67.3%, 76.3%, 80.1%, and 89.8% under the same conditions.

Fabrication of polycrystalline 3C-SiC diode for harsh environment micro chemical sensors and their characteristics (극한 환경 마이크로 화학센서용 다결정 3C-SiC 다이오드 제작과 그 특성)

  • Shim, Jae-Cheol;Chung, Gwiy-Sang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.195-196
    • /
    • 2009
  • This paper describes the fabrication and characteristics of polycrystalline 3C-SiC thin film diodes for extreme environment applications, in which the this thin film was deposited onto oxidized Si wafers by APCVD using HMDS In this work, the optimized growth temperature and HMDS flow rate were $1,100^{\circ}C$ and 8sccm, respectively. A Schottky diode with a Au, Al/poly 3C-SiC/$SiO_2$/Si(n-type) structure was fabricated and its threshold voltage ($V_d$), breakdown voltage, thickness of depletion layer, and doping concentration ($N_D$) values were measured as 0.84V, over 140V, 61nm, and $2.7{\times}10^{19}cm^2$, respectively. To produce good ohmic contact, Al/3C-SiC were annealed at 300, 400, and $500^{\circ}C$ for 30min under a vacuum of $5.0{\times}10^{-6}$Torr. The obtained p-n junction diode fabricated by poly 3C-SiC had similar characteristics to a single 3C-SiC p-n junction diode.

  • PDF

The Studies on the Thermal Resistant Properties of $WO_3/TiO_2$ and $V_2O_5-WO_3/TiO_2$ Catalysts for NOx Reduction of Flue Gases from Industrial Boiler and on Catalyst Surface Acid Characteristics (産業用 보일러의 燃燒 排가스 中 NOx 處理를 위한 SCR 用 $WO_3/TiO_2$$V_2O_5/TiO_2$ 觸媒들의 耐熱特性과 表面 酸特性에 關한 硏究)

  • 이중범;임상윤;정석진;성준용
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.6 no.1
    • /
    • pp.31-42
    • /
    • 1990
  • In order to suggest an efficient catalyst systems for NOx reduction of flue gases from industrial boilers, $TiO_2$ supported $WO_3-V_2O_5, V_2O_5$ and $WS_2$ catalysts were tested for the performances of NOx reduction at high reactin temperature range (250-500$^\circ$C) using a simulated flue gas system. It was found that while the proposed $WO_3/TiO_2$ and $WO_3-V_2O_5/TiO_2$ catalysts showed a significant high NOx reduction efficiency at about 350-400$^\circ$C, the conventional commercial catalyst of $V_2O_5/TiO_2$ showed a significant drop in NOx reduction efficiency due to the excessive $NH_3$ oxidation. From the measurement of surface acidities of those catalysts, it was found that the acidity are well correlated with the activities of NOx reduction. The reason of high activity of $WO_3$ series catalysts at high reaction temperature seems due to the low value of surface excess oxygen compared with that of $V_2O_5/TiO_2$ seems equivalent to the acid site of that catalyst.

  • PDF

Assessment of the Usefulness of an IMRT Plan Using a Shell-Type Pseudo Target with Patients in Stage III or IV of NSCLC (비소세포폐암 III, IV기 환자에 있어서 Shell-Type Pseudo Target을 이용한 세기 조절 방사선치료계획기법의 유용성 평가)

  • Lee, Sang-Bong;Park, Ki-Ju;Park, Du-Chan;Kim, Man-Wo;Kim, Jun-Gon;Noh, Sung-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.95-106
    • /
    • 2012
  • Purpose: The objective of this study was to investigate the usefulness of an IMRT treatment plan according to whether there was a shell-type pseudo target during radiation therapy for patients in Stage III or IV of non-small cell lung cancer (NSCLC). Materials and Methods: After setting an IMRT (Intensity-Modulated Radiation Therapy, IMRT) plan for when there was a shell-type pseudo target (SPT) and when there was none (WSPT) with 22 patients in Stage III or IV of NSCLC, the investigator analyzed dose-volume histograms (DVHs) and made assessment with dosimetric comparisons such as homogeneity index (HI) inside the tumor target, conformity index (CI) of the tumor target, spinal cord maximum dose, Esophagus $V_{50%}$, mean lung dose (MLD), and $V_{40%}$, $V_{30%}$, $V_{20%}$, $V_{10%}$, $V_{5%}$. Results: The mean CI of WSPT and SPT was $1.22{\pm}0.04$ and $1.16{\pm}0.032$ ($.000^*$), respectively, and the mean HI of WSPT and SPT was $1.06{\pm}0.015$ and $1.07{\pm}0.014$ ($.000^*$), respectively. In SPT, the mean of each CI difference decreased by $-5.16{\pm}2.54%$, while HI increased by average $0.81{\pm}0.47%$. Esophagus $V_{50%}$ recorded $14.54{\pm}12.01%$ (WSPT) and $12.14{\pm}11.09%$ ($.000^*$, SPT) with the mean of SPT differences dropping by $-26.37{\pm}25.05%$. Mean spinal cord maximum dose was $3,898.44{\pm}1,075.0$ cGy (WSPT) and $3,810.8{\pm}1,134.9$ cGy ($.004^*$, SPT) with SPT dropping by average $-3.36{\pm}5.81%$. As for lung $V_{X%}$, the mean of $V_{5%}$ and $V_{10%}$ differences was $-1.62{\pm}2.29%$ ($.006^*$) and $-1.98{\pm}5.02%$ ($.005^*$), respectively with SPT making a decrease. The mean of V20%, V30%, and V40% differences was $-3.51{\pm}3.07%$ ($.000^*$), $-4.84{\pm}6.01%$ ($.000^*$), and $-6.16{\pm}8.46%$ ($.001^*$), respectively, with SPT making a decrease with statistical significance. In MLD assessment, SPT also dropped by average $-2.83{\pm}2.41%$ ($.000^*$). Those results show that SPT allows for mean 169 cGy (Max: 547 cGy, Min: 6.4 cGy) prescription dose. Conclusion: An IMRT treatment plan with SPT during radiation therapy for patients in Stage III or IV of NSCLC will help to reduce the risk of lung toxicity and radiation-induced pneumonia by cutting down radiation doses entering the normal lung, reduce the local control failure rate during radiation therapy due to increasing prescription doses to a certain degree, and increase treatment effects.

  • PDF

Effect of V and Nb on Mechanical Properties of Non-Heattreated Hot Forging Steels (열간단조용 비조질강의 기계적 성질에 미치는 V, Nb의 영향)

  • Wee, Kyeom-Bok;Jeong, Woon-Tae;Lee, Kyeong-Seop;Wang, Seong-Do
    • Korean Journal of Materials Research
    • /
    • v.2 no.1
    • /
    • pp.65-75
    • /
    • 1992
  • 0.4wt%C steel added with V and/or Nb were forged and followed by air cooling. The structure-property relationships were examined and multiple regression analysis was conducted to quantify the magnitudes of effects of microalloying elements on the properties of the steels. All material's tensile strength are greater than $70kg/\textrm{mm}^2$, so they are equal to or superior to Q/T material's(S45C). Their impact energies are less than 40J, so they are 50% of Q/T material's. Increasing the content of V from 0.10 to 0.15 wt% had brought improvement in UTS about 20% but with some sacrifice of impact energy. These were the results from the precipitation strengthening by fine dispersion of VC in ferrite, increment of pearlite volume fraction and decrement of pearlite interlamellar spacings. However, increasing the content of Nb from 0.05 to 0.l0wt % slightly improved UTS and impact energy. NbC precipitates were more effective in suppression of austenite grain coarsening than VC precipitates. Combined additions of V+Nb were more effective to bring impact toughness than sole addition. Optimum combination of strength and toughness was accomplished wish 0.4C-1. 19Mn-0.05S-0.12V-0.07Nb steel.

  • PDF