• Title/Summary/Keyword: V-tie

Search Result 54, Processing Time 0.031 seconds

Effect of Bending Angle and Embedment Length on the Bond Characteristics of V-shaped Tie Reinforcement (절곡각 및 묻힘길이에 따른 V형 띠철근의 부착특성)

  • Kim, Won-Woo;Yang, Keun-Hyeok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.5
    • /
    • pp.465-471
    • /
    • 2015
  • This study proposed V-shaped tie bar method as an alternative of internal cross-tie for reinforced concrete columns in order to enhance the constructability and confinement effectiveness of the lateral tie bars. A total of 35 pull-out specimens were prepared with the parameters of concrete compressive strength and bending angle and embedment length of the V-shaped bar to examine the bond stress-slip relationship of the V-shaped tie bar. The bond strength of the V-shaped tie bars with the bending angle not exceeding $60^{\circ}$ was higher than the predictions obtained from the equations of CEB-FIP provision. Considering the constructability and bond behavior of the V-shpaed tie bar, the bending angle and embedment length of such bar can be optimally recommended as $45^{\circ}$ and 6db, respectively, where db is the diameter of the tie bar.

A Study on the Application of SFCL on 22.9 kV Bus Tie for Parallel Operation of Power Main Transformers in a Power Distribution System (배전계통에 전력용 변압기 병렬운전시 22.9 kV SFCL Bus Tie 적용방안에 관한 연구)

  • On, Min-Gwi;Kim, Myoung-Hoo;Kim, Jin-Seok;You, Il-Kyoung;Lim, Sung-Hun;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • This paper analyzed the application of Superconducting Fault Current Limiter (SFCL) on 22.9 [kV] bus tie in a power distribution system. Commonly, the parallel operations of power main transformers offer a lot of merits. However, when a fault occurs in the parallel operation of power main transformer, the fault currents might exceed the interruption capacity of existing protective devices. To resolve this problem, thus, the SFCL has been studied as the fascinating device. In case that, Particularly, the SFCL could be installed to parallel operation of various power main transformers in power distribution system of the Korea Electric Power Corporation (KEPCO) on 22.9 [kV] bus tie, the effect of the resistance of SFCL could reduce the increased fault currents and meet the interruption capacity of existing protective devices by them. Therefore, we analyzed the effect of application and proposed the proper impedance of the R-type SFCL on 22.9 [kV] bus tie in a power distribution system using PSCAD/EMTDC.

Bond-Slip Tests of V-ties as a Supplementary Lateral Reinforcement (보조 띠철근으로써 V-타이의 부착-미끄러짐 관계 실험)

  • Kwon, Hyuck-Jin;Yang, Keun-Hyeok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.157-158
    • /
    • 2017
  • This tests examined bond stress-slip relationship of V-ties embedded into concrete as a supplementary lateral reinforcement proposed for ductility of concrete flexural members. The different leg shapes of V-ties were prepared as a test parameter. The V-tie with pressed end-legs exhibited 28% higher bond strength than the conventional V-ties, whereas bond stress-slip curves were insignificantly affected by the embedment length of V-ties.

  • PDF

A Study on the Bus-Tie Application of 154kV HTS-FCL in Korean Power System (실계통에서의 154kV HTS-FCL Bus-Tie 최적 적용방안에 관한 연구)

  • Kim Jong-Yul;Yoon Jae Young;Lee Seung Rvul
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.5
    • /
    • pp.226-233
    • /
    • 2005
  • As the power demand has been increasing, a fault current problem is becoming more serious in real power system. Various ways like bus-split operation, transmission line open operation, are used in Korean power system for solving the problem. In this time, superconducting FCL(Fault Current Limiter) has been developed as a vary attractive alternative since HTS(High Temperature Superconductivity) was discovered. Korea, a project developing superconducting FCL to apply to 154kV transmission system is proceeding. Therefore, a power system analysis for SFCL application to power system is necessary, This paper presents the determination of quenching resistance and the selection of optimal cites when 154kV HTS-FCL is applied to Korean power system.

Inelastic Behavior and Seismic Retrofit of Inverted V Braced Steel Frames (역V형 철골 가새골조의 비탄성거동 및 내진성능향상 방안에 관한 연구)

  • Kim, Nam Hoon;Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.571-578
    • /
    • 2003
  • An effective seismic retrofit scheme for inverted V braced (or chevron type) steel frames was proposed by studying the redistribution of forces in the post-buckling range. The steel frames with chevron bracing are highly prone to soft story response once the compression brace buckles under earthquake loading. This paper shows that the seismic performance of such frames could be significantly improved by supplying tie bars to redistribute the inelastic deformation demand over the height of the building. A practical design method of the retrofit tie bars was also proposed by considering the sequence of buckling occurrence.

A Study on the Minimization of Tie-plate Loss of Cast Resin Transformer using Surface Impedance Boundary Condition (표면 임피던스 경계조건을 이용한 몰드변압기 Tie-plate 손실 최소화에 관한 연구)

  • Hwang, Sung-Ryul;Shin, Pan Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1334-1340
    • /
    • 2017
  • In this paper, a tie-plate shape is optimized by using the numerical technique to reduce the stray load loss of the tie-plate which is a mechanical structure for assembling and supporting of the transformer core. The eddy current loss of the structure is calculated by an electromagnetic field FEM program and the results are compared with 4 different shapes of tie-plates. Since the thickness of the tie-plate is very thin, and the skin depth is very small, the number of FE elements for 3-D transformer model is too big to solve. So, the surface impedance boundary condition (SIBC) is used to reduce the system matrix size and its computing time. To verify the method a 2.5 MVA 22,900/380V distribution transformer is simulated using one objective function and three design variables with some constraints. The final optimized tie-plate has three slots of 6 mm width and 23 mm gap, and the loss is reduced by 75 %. Consequently, the proposed algorithm seems to be considerably applicable to electric machinery as well as power transformer.

Pattern and thermal durability of flexible copper clad laminate depends on the ternary tie-coating material (삼원계 tie-coating 물질에 따른 FCCL(연성동박적층판)의 패터닝성과 내열성의 관한 연구)

  • Kim, Si-Myeong;Kim, Sang-Ho
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.275-276
    • /
    • 2015
  • 기존의 상용화된 Ni-Cr tie-coating 물질은 내열성 시험 후 강도가 저하되고, Cr 성분이 patterning후에 완벽하게 제거 되지 않아서 누설 전류를 만드는 단점을 갖고 있다. 따라서 이 연구에서는 기존의 Ni-Cr 과 삼원계 Ni-Cr-X(X는 Nb, V, Mo, Ti) 물질의 패터닝성과 내열성을 비교하였다.

  • PDF

Proposals of Reliable Shapes of Supplementary V-ties for Section Jacketing Method of Columns (기둥의 단면 확대보강을 위한 V-타이 보조 띠철근의 형상 제시)

  • Kwon, Hyuck-Jin;Yang, Keun-Hyeok;Sim, Jae-Il
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.2
    • /
    • pp.99-107
    • /
    • 2018
  • The objective of the present study is to propose a reliable shape of supplementary V-ties in the section jacketing approach for seismic strengthening of reinforced concrete columns. A total of 24 pull-out specimens were prepared. The test parameters selected with regard to bond strength of V-ties were the shape of V-ties, embedment length of V-tie legs, and compressive strength of concrete. The measured bond strength of V-ties with different shapes were compared with that of the conventional V-ties and predictions using CEB-FIP equation. Ultimately, V-ties with pressed end-details at their legs could be recommended for the supplementary lateral reinforcement of strengthening columns with jacketing thickness less than the embedment length [= max (75mm, $6d_b$)] of conventional V-ties, where $d_b$ is the diameter of the reinforcing bar used for V-ties.

Diffusion Kinetics of Si in GaAs and Related Defect Chemistry (GaAs에서의 Si의 확산기구와 그에 관련된 격자 결함 화학)

  • Lee, Gyeong-Ho
    • ETRI Journal
    • /
    • v.11 no.4
    • /
    • pp.75-83
    • /
    • 1989
  • The diffusion mechanism of Si in GaAs was investigated using different diffusion sources based on the Si-Ga-As ternary phase equilibria. The Si profiles are measured with secondary ion mass spectrometry and differ significantly for sources taken from the different phase fields in the ternary phase diagram. Neutral As vacancy diffusion is proposed for acceptor Si diffusion anneals using a Ga - Si - GaAs source. Donor Si diffusion using As - rich sources and a Si -GaAs tie line source shows concentration dependent diffusion behavior. Concentration dependent diffusion coefficients of donor Si for As - rich source diffusion were found to be related to net ionized donor concentration and showed three regimes of different behavior: saturation regime, intermediate regime,and intrinsic regime. Ga vacancies are proposed to be responsible for donor Si diffusionin GaAs: $Si_Ga^+V_Ga^-$ (donor Si -acceptor Gavacancy) complex for the extrinsic regime and neutral $V_G$a, for the intrinsic regime.The Si - GaAs tie line source resulted in two branch profiles, intermediate between the As - rich and the Ga - rich source diffusion cases.

  • PDF

Multi Area Economic Dispatch using Secant Method

  • Sudhakar, A.V.V.;Chandram, Karri;Jayalaxmi, A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.744-751
    • /
    • 2013
  • In this paper, Secant method is proposed to solve multi area economic dispatch (MAED) problem. Generator limits of all generators in each area are calculated at given area power demands plus export (or import) using secant method and the generator limits of all generators are modified as modified generator limits. Central economic dispatch (CED) problem is used to determine the output powers of all generators. Here, Secant method is applied to solve the CED problem. The proposed approach has been tested on two-area (two generators in each area) system and four-area (four generators in each area) system. It is observed from various cases that the proposed approach provides optimally best solution in terms of cost with tie line loss with less computational burden.