• 제목/요약/키워드: V-model

검색결과 3,796건 처리시간 0.035초

낮은 위상잡음을 갖는 위성 중계기용 Engineering Model 발진기의 비선형 설계 (Nonlinear Design of Engineering Model Oscillator with a Very Low Phase Noise fot Satellite Transponder)

  • 이문규;류근관;염인복;이성팔
    • 한국전자파학회논문지
    • /
    • 제12권4호
    • /
    • pp.622-629
    • /
    • 2001
  • 본 논문에서는 Ku 대역 위성중계기에 사용되는 저위상잡음 특성을 갖는 Engineering Model 전압제어 발진기를 비선형 설계방법으로 설계하였다. 제작한 발진기의 주파수는 1~5 V의 제어전압으로 1.745~1.577MHz의 발진범위를 갖는다. 공급전력은 5V, 6.9mA를 요구한다. 제작한 발진기의 위상잡음은 -114 dBc/Hz @10kHz offset, -131 dBc/hz @100kHz offsetf을 갖고 출력전력으로 5 dBm을 얻었다.

  • PDF

헴트 소자의 해석적 직류 모델 (AN ANALYTICAL DC MODEL FOR HEMTS)

  • 김영민
    • ETRI Journal
    • /
    • 제11권2호
    • /
    • pp.109-119
    • /
    • 1989
  • Based on the 2-dimensional charge-control simulation[4], a purely analytical model for MODFET's is proposed. In this model, proper treatment of the diffusion effect in the 2-DEG transport due to the gradual channel opening along the 2-DEG channel was made to explain the enhanced mobility and increased thershold voltage. The channel thickness and gate capacitance are experssed as functions of gate vlotage including subthreshold characteristics of the MODFET's analytically. By introducing the finite channel opening and an effective channel-length modulation, the slope of the saturation region of the I-V curves was modeled. The smooth transition of the I-V curves from linear-to-saturation region of the I-V curves was possible using the continuous Troffimenkoff-type of field-dependent mobility. Furthermore, a correction factor f was introduced to account for the finite transtition section forming between the GCA and the saturated section. This factor removes the large discrepanicies in the saturation region fo the I-V curves presicted by existing 1-dimensional models. The fitting parameters chosen in our model were found to be predictable and vary over relatively small range of values.

  • PDF

A Coherent Methodology for the Evaluation of a Steam Explosion Load Using TEXAS-V

  • Song, Jin-Ho;Park, Ik-Kyu;Kim, Jong-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제36권6호
    • /
    • pp.571-581
    • /
    • 2004
  • A methodology is proposed for the evaluation of a steam explosion load on a reactor scale by evaluating the steam explosion model against the experimental data. Being part of the OECD/SERENA program,, appropriate data was selected by international experts and the analytical model of TEXAS-V was chosen. The procedure consists of two steps. the pre-mixing model was verified against the FARO L-14 and FARO L-28 data. The explosion model was verified against the experimental data of KROTOS-44, FARO L-33, TROI-13, and TROI-34. The capabilities and deficiencies of the fundamental models of the TEXAS-V are reviewed in terms of their adequacy in a simulation of steam explosion on a reactor scale.

AC Loss를 고려한 22.9kV급 Mini-Model 변압기의 절연 설계 및 시험 (Insulating Design and Test of 22.9kV Class Mini-Model Transformer Considering AC Loss)

  • 백승명;정종만;곽동순;김해종;석복렬;김상현
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권8호
    • /
    • pp.420-424
    • /
    • 2004
  • This paper presents experimental data from model windings with different arrangement of coil in order to provide information to design a 22.9kV class HTS transformer. Before experiment, the composite insulation of two different type of HTS transformers are investigated. The first basic of investigation is a breakdown characteristic of liquid nitrogen and flashover characteristic on the GFRP surface under ac and impulse, The second investigation is insulation design, manufacture and test of model windings. These include a AC withstand voltage test of 50 kV rms and a lighting impulse test of 150 kV at peak.

25.8kV 25kA 3상 GIS 모선의 온도상승 예측 (Temperature Rise Prediction of 25.8kV 25kA Three-phase GIS Bus Bar)

  • 김중경;한성진;오연호;박경엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.894-895
    • /
    • 2007
  • This paper presents coupled analysis between finite element method and analytic technique for predicting temperature rise of 25.8kV 25kA three-phase GIS bus bar. The power losses and temperature distribution of three-phase GIS bus bar model are analyzed by magneto-thermal finite element method. The heat transfer coefficients on the boundaries are analytically calculated by applying Nusselt number considering material constant and model geometry for the natural convection. And these are used as the input data to predict the temperature rise of three-phase GIS bus bar model by coupled magneto-thermal F.E.A. The predicted temperature of 25.8kV 25kA three-phase GIS bus bar model shows good agreement with the experimental data.

  • PDF

Software Reliability of Safety Critical FPGA-based System using System Engineering Approach

  • Pradana, Satrio;Jung, Jae Cheon
    • 시스템엔지니어링학술지
    • /
    • 제14권2호
    • /
    • pp.49-57
    • /
    • 2018
  • The main objective of this paper is come up with methodology approach for FPGA-based system in verification and validation lifecycle regarding software reliability using system engineering approach. The steps of both reverse engineering and re-engineering are carried out to implement an FPGA-based of safety critical system in Nuclear Power Plant. The reverse engineering methodology is applied to elicit the requirements of the system as well as gain understanding of the current life cycle and V&V activities of FPGA based-system. The re-engineering method is carried out to get a new methodology approach of software reliability, particularly Software Reliability Growth Model. For measure the software reliability of a given FPGA-based system, the following steps are executed as; requirements definition and measurement, evaluation of candidate reliability model, and the validation of the selected system. As conclusion, a new methodology approach for software reliability measurement using software reliability growth model is developed.

이중에너지 전산화단층촬영을 이용한 요로결석의 성분 분석에 관한 연구 (Classification of Urinary Stone into Uric Acid & Non-uric Acid by Dual-Energy)

  • 정명진;김성길
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.835-841
    • /
    • 2023
  • 팬텀모델에서 이중에너지 전산화단츨촬영(DECT)를 이용한 요로결석의 성분분석을 통해 임상적 유용성에 대해 알아보고자 한다. 17명의 환자로부터 요로결석을 추출하여, 작은 플라스틱 병(Plastic Bottle) 안에 각각의 요로결석을 삽입한 후, 인체와 비슷한 돈육을 이용하여 실험팬텀을 제작하였다. 640-Slice MSCT(Auquilion ONE, Toshiba Medical Center, Japan)의 이중에너지 방식에서 Volume scan 방식을 사용하여 촬영하였고, 얻어진 두 가지의 영상을 Dual-energy software("DE stone Analysis" software version 4.3, Toshiba)에서 요산석과 비요산석의 성분분석하고 HU값을 각각 측정하였다. 요로결석의 성분은 전체 17개의 요로결석 중에서 요산석은 6개(35.29%)였고, 비요산석은 11개(64.71%)로 나타났다. 요산석의 경우 135kV는 348.87±166.37, 100kV는 345.33±151.18, 80kV는 337.94±172.77로 나타났고, 비요산석의 경우 135kV는 551.93±297.09, 100kV는 747.04±351.31, 80kV는 958.19±424.72로 나타났다. 80kV에서는 요산석과 비요산석의 HU값의 차이가 통계적으로 유의한 차이를 보였고(P<0.05), 비요산석의 경우에 80kV와 135kV의 HU값은 통계적의 유의한 차이를 보였다(P<0.05). 시술 후 적출된 요로결석을 이용한 팬텀실험연구에서는 DECT를 이용하여 에너지에 따라 서로 다르게 변화하는 HU값의 차이로 요산석과 비요산석을 구분할 수 있었다. 향후, 이중에너지에 대한 연구와 재구성방법의 연구가 진행된다면, 요로결석의 치료에 DECT가 유용할 것으로 기대된다.

Analysis of a Parasitic-Diode-Triggered Electrostatic Discharge Protection Circuit for 12 V Applications

  • Song, Bo Bae;Lee, Byung Seok;Yang, Yil Suk;Koo, Yong-Seo
    • ETRI Journal
    • /
    • 제39권5호
    • /
    • pp.746-755
    • /
    • 2017
  • In this paper, an electrostatic discharge (ESD) protection circuit is designed for use as a 12 V power clamp by using a parasitic-diode-triggered silicon controlled rectifier. The breakdown voltage and trigger voltage ($V_t$) of the proposed ESD protection circuit are improved by varying the length between the n-well and the p-well, and by adding $n^+/p^+$ floating regions. Moreover, the holding voltage ($V_h$) is improved by using segmented technology. The proposed circuit was fabricated using a $0.18-{\mu}m$ bipolar-CMOS-DMOS process with a width of $100{\mu}m$. The electrical characteristics and robustness of the proposed ESD circuit were analyzed using transmission line pulse measurements and an ESD pulse generator. The electrical characteristics of the proposed circuit were also analyzed at high temperature (300 K to 500 K) to verify thermal performance. After optimization, the $V_t$ of the proposed circuit increased from 14 V to 27.8 V, and $V_h$ increased from 5.3 V to 13.6 V. The proposed circuit exhibited good robustness characteristics, enduring human-body-model surges at 7.4 kV and machine-model surges at 450 V.