• Title/Summary/Keyword: V-PASS

Search Result 339, Processing Time 0.022 seconds

High Current MIG Welding of Al 5083 Alloy under Ar/He Mixed Gas Shielding (Ar/He 보호가스분위기에서 Al 5083 합금의 대전류 MIG 용접특성)

  • Choi, Young-Bae;Hwang, In-Sung;Kang, Mun-Jin;Kim, Dong-Cheol
    • Journal of Welding and Joining
    • /
    • v.32 no.1
    • /
    • pp.87-92
    • /
    • 2014
  • Recently, use of thick Al 5083 plate has increased in production of LNG storage tank. In general, multi-pass welding has been used to achieve sufficient penetration in thick plate welding. High current welding which enables high deposition and deep penetration is preferred in thick plate welding because the increase of number of pass increases manufacturing cost and formation of weld defect. In this study, welding characteristics according to various Ar/He shielding gas composition was investigated in high current MIG welding. The bead-on-plate welding and V groove welding were conducted on Al 5083 alloy with a thickness of .25 mm. The effect of shielding gas composition on bead shape was evaluated and proper shielding gas composition was proposed. Also arc stability was examined under selected shielding gas composition. One side-one pass welding experiments were conducted for V groove specimen with a thickness of 25 mm. Mechanical properties and hardness profiles were measured for the V groove specimens.

Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

  • Jeon, Hosang;Kim, Dong Woon;Joo, Ji Hyeon;Ki, Yongkan;Kim, Wontaek;Park, Dahl;Nam, Jiho;Kim, Dong Hyeon
    • Progress in Medical Physics
    • /
    • v.32 no.1
    • /
    • pp.18-24
    • /
    • 2021
  • Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the accuracies of target delineation and treatment dose calculation are inevitably lowered. We evaluated the accuracy of the calculated doses using an image restoration method with hybrid CT, which was introduced in our previous study. Methods: A cylindrical phantom containing four metals, namely, silver, copper, tin, and tungsten, was scanned using kV-CT and megavoltage CT to produce hybrid CT images. We created six verification plans for three head and neck patients on kV-CT and hybrid CT images of the phantom and calculated their doses. The actual doses were measured with film patches during beam delivery using tomotherapy. We used the gamma evaluation method to compare dose distribution between kV-CT and hybrid CT with three gamma criteria, namely, 3%/3 mm, 2%/2 mm, and 1%/1 mm. Results: The gamma pass rates decreased as the gamma criteria were strengthened, and the pass rate of hybrid CT was higher than that of kV-CT in all cases. When the 1%/1 mm criterion was used, the difference in gamma pass rates between them was up to 13%p. Conclusions: According to our findings, we expect that the use of hybrid CT can be a suitable approach to avoid the effect of severe metal artifacts on the accuracy of dose calculation and contouring.

Precipitation and Recrystallization of V-Microalloyed Steel during Hot Deformation (V 첨가강의 고온변형시 석출 및 재결정에 관한 연구)

  • 조상현;김성일;유연철
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1996.03b
    • /
    • pp.48-54
    • /
    • 1996
  • The continuous deformation , multistage deformation and stress relaxation were carried out to investigate the strain induced procipitation by torsion tests in the range of 1000∼800$^{\circ}C$, 0.05/sec∼5/sec for V-microalloyed steel. The starting temperature and time for the initiation of precipitation were determined by stress relaxation tests and the distribution of percipitates increased at higher strain rate and the mean size of precipitates was found to be about 50nm. The precipitation starting time decreased with increasing strain rate from 0.05/sec to 5 /sec and pre-strain. The effect of deformation conditions on the no-recrystallization temperature(Tnr) was determined in the multistage deformation with declining temerature. The Tnr decreased with increasing strain and strain rae. In the controlled rolling, grain refinement and precpitation hardening effects could be achieved by the alternative large pass strain at the latter half pass stage under the condition of low temperature and high strain rate.

  • PDF

Implementation of V-Band Filter using MCM-D Technology (MCM-D 기판 공정 기술을 이용한 V-Band Filter 구현)

  • Yoo, Chan-Sei;Song, Sang-Sub;Park, Jong-Chul;Seo, Kwang-Seok
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.169-170
    • /
    • 2006
  • A band pass filter for the V-band application with unique circuit and structure was designed and implemented using 2-metals, 3-BCB layers. In the mean while the effective electrical conductivity of metal layer was extracted and its value was $4{\times}10^7S/m$. The insertion loss of band pass filter at 60 GHz was 3.0 dB and group delay was below 0.1 ns.

  • PDF

Tunable Band-pass Filters using Ba0.5Sr0.5TiO3 Thin Films for Wireless LAN Application (무선랜 대역용 Ba0.5Sr0.5TiO3 박막을 이용한 가변 대역 통과 여파기)

  • Kim, Ki-Byoung;Yun, Tae-Soon;Lee, Jong-Chul;Kim, Il-Doo;Lim, Mi-Hwa;Kim, Ho-Gi;Kim, Jong-Heon;Lee, Byungje;Kim, Na-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.8
    • /
    • pp.819-826
    • /
    • 2002
  • In this paper, the performance of Au / $Ba_{0.5}Sr_{0.5}TiO_3$ (BST) / Magnesium oxide (MgO) two-layered electrically tunable band-pass Filters (BPFs) is demonstrated. The devices consist of microstrip, coplanar waveguide (CPW), and conductor-backed coplanar waveguide (CBCPW) structures. These BST thin film band-pass filters have been designed by the 2.5 D field simulator, IE3D, Zeland Inc., and fabricated by thin film process. The simulation results, using the 2-pole microstrip, CPW, and CBCPW band-pass filters, show the center frequencies of 5.89 GHz, 5.88 GHz, and 5.69 GHz, and the corresponding insertion losses are 2.67 dB, 1.14 dB, and 1.60 dB, with 3 %, 9 %, and 7 % bandwidth, respectively. The measurement results show the center frequencies of 6.4 GHz, 6.14 GHz, and 6.04 GHz, and their corresponding insertion losses are 6 dB, 4.41 dB, and 5.41 dB, respectively, without any bias voltage. With the bias voltage of 40 V, the center frequencies for the band-pass filters are measured to be 6.61 GHz, 6.31 GHz, and 6.21 GHz, and their insertion losses are observed to be 7.33 dB, 5.83 dB, and 6.83 dB, respectively. From the experiment, the tuning range for the band-pass filters are determined as about 3 % ~ 8 %.

A 41dB Gain Control Range 6th-Order Band-Pass Receiver Front-End Using CMOS Switched FTI

  • Han, Seon-Ho;Nguyen, Hoai-Nam;Kim, Ki-Su;Park, Mi-Jeong;Yeo, Ik-Soo;Kim, Cheon-Soo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.675-681
    • /
    • 2016
  • A 41dB gain control range $6^{th}$-order band-pass receiver front-end (RFE) using CMOS switched frequency translated impedance (FTI) is presented in a 40 nm CMOS technology. The RFE consists of a frequency tunable RF band-pass filter (BPF), IQ gm cells, and IQ TIAs. The RF BPF has wide gain control range preserving constant filter Q and pass band flatness due to proposed pre-distortion scheme. Also, the RF filter using CMOS switches in FTI blocks shows low clock leakage to signal nodes, and results in low common mode noise and stable operation. The baseband IQ signals are generated by combining baseband Gm cells which receives 8-phase signal outputs down-converted at last stage of FTIs in the RF BPF. The measured results of the RFE show 36.4 dB gain and 6.3 dB NF at maximum gain mode. The pass-band IIP3 and out-band IIP3@20 MHz offset are -10 dBm and +12.6 dBm at maximum gain mode, and +14 dBm and +20.5 dBm at minimum gain mode, respectively. With a 1.2 V power supply, the current consumption of the overall RFE is 40 mA at 500 MHz carrier frequency.

High Frequency Noise Reduction Method Using a Newly Designed Low-pass Filter in DFT-Based Phasor Estimation (DFT 기반 페이저 연산 시 새로운 저역통과필터를 이용한 고주파 노이즈 경감 방법)

  • Baek, Min-Woo;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.898-904
    • /
    • 2017
  • DFT(Discrete Fourier Transform) is one of the most widely used method to estimate the phasor of a relaying signal. The harmonics are eliminated by the DFT. However, high frequency components, except for harmonics, are not removed and cause an error in DFT-based phasor estimation process. This paper suggests high frequency noise reduction method by using a newly designed low-pass filter to estimate a signal phasor. When selecting a stop-band cut-off frequency of the low-pass filter, high frequency components generated by faults are considered. To reduce the phasor estimation delay caused by a low-pass filter, this paper proposes a low-pass filter whose settling time is reduced. An adverse effect of high frequency noise on DFT-based phasor estimation is reduced. To evaluate the performance of the proposed method, signals which are collected under a fault condition at a 345[kV] transmission system modeled by EMTP-RV are used.

Application of band-pass filtering techniques for improvement on 3D tomogram (3D Tomogram 향상을 위한 Band-pass Filtering 기술의 활용)

  • Ryu, Keun-Yong;Kim, Soo-Jin;Jung, Hyun-Suk;Kweon, Hee-Seok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2011.04a
    • /
    • pp.382-383
    • /
    • 2011
  • 초고전압 투과전자현미경으로부터 생산된 2D 이미지들에는 고전압(1250 kV)의 사용으로 인한 다양한 노이즈가 발생한다. 따라서 2D 이미지로부터 3D tomogram으로 재구성시 선명도 향상을 위하여 2D 이미지의 노이즈 제거 과정은 필수적이다. 본 연구에서는 band-pass filtering 기법을 활용하여 노이즈를 상당 부분 제거하였고, 필터링된 이미지로부터 3D tomogram으로 재구성한 경우 band-pass filtering의 효과가 2D 이미지에서 뿐만아니라 3D tomogram으로 재구성 했을 경우에 어떤 대역의 filter radius를 적용해야 더욱 효과가 크다는 사실을 확인하였다.

Design and Implementation of a 9V Mini-Electrocardiograph(ECG) system (9V 초소형 심전도계의 설계 및 구현)

  • Song, Myeong-Kil;Park, Kwang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.5
    • /
    • pp.1130-1133
    • /
    • 2008
  • In this paper, a mini-Electrocardiograph(ECG) system operated by a general 9V alkaline battery is designed and implemented. The manufactured ECG consists of the instrumentation amplifier stage for detecting and amplifying the heart signal, the high pass filter(HPF), the low pass filter(LPF), the differentiator cirduit, and the peak detector. The detected heart signal through three leads is displayed cleanly on the oscilloscope, which shows the good operation of our ECG. As the detected heart signal is digitalized and displayed on the small LCD unit, the convenience of easy checkup and portability of the implemented ECG can be largely improved. Therefore, whenever and wherever anyone may checkup his/her cardiac state with ease.

Modified neocognitron for recognizing multi-patterns (복수 패턴 인식을 위한 변형된 네오코그니트론)

  • 김태우;최병욱
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.10
    • /
    • pp.140-148
    • /
    • 1994
  • In this paepr, the modified neocognitron, which has capability of recognizing multi-patterns in input image in one pass, is proposed. It is the hierarchical neural network composed of S and V layer which are able to extract features and of C layer with little effect from deformation, changes in size, shifts in position. S and V cells extract the features of all patterns in input image by applying DCC(don't care condition) to those cells. S and C cells also have position informations of extracted patterns. Position information is used in extracting good features without extracted features beting interfered one another. The proposed method is shorter in recognition time than the selective attention method with backward connection, because of recognizing multi-patterns in one passe. The modified neocognitron can recognizze attached multi-patterns because of using DCC and position informations.

  • PDF