• Title/Summary/Keyword: V-Factor

Search Result 2,490, Processing Time 0.03 seconds

A Novel Parameter Extraction Method for the Solar Cell Model (새로운 태양전지 모델의 파라미터 추출법)

  • Kim, Wook;Kim, Sang-Hyun;Lee, Jong-Hak;Choi, Woo-Jin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.372-378
    • /
    • 2009
  • With the increase in capacity of photovoltaic generation systems, studies are being actively conducted to improve system efficiency. In order to develop the high performance photovoltaic power system it is required to understand the physical characteristics of the solar cell. However, solar cell models have a non-linear form with many parameters entangled and conventional methods suggested to extract the parameters of the solar cell model require some kind of assumptions, which accompanies the calculation errors, thereby lowering the accuracy of the model. Therefore, in this paper a novel method is proposed to calculate the ideality factor and reverse saturation current of the solar cell from the I-V curve measured and announced by solar cell manufacturers, derive the ideal I-V curve, and then extract the series and shunt resistances value from the difference between the ideal and measured I-V curve. Also, validity of the proposed method is demonstrated by calculating the correlation between I-V curve based on modeling parameters and I-V curve actually measured through least squares method.

A Study on the absorbed dose to water for high energy electron beams using Water equivalency of plastic phantom (고 에너지 전자선에서 물등가 고체팬톰을 이용한 물 흡수선량 측정에 관한 연구)

  • Sin, Dong-Ho;Sin, Dong-Oh;Kim, Sung-Hoon;Park, Sung-Yong;Ji, Young-Hoon;Ahn, Hee-Kyung;Kang, Jin-Oh;Hong, Seong-Eon
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.166-169
    • /
    • 2004
  • In the International Code of Practice for dosimetry TRS-398 published by International Atomic Energy Agency(IAEA), water equivalency plastic phantom may be used under certain circumstances for electron beam dosimetry for beam quality E0${\leq}$ 10 MeV. In this study, Palstic Water$^{TM}$ and Virtual Water$^{TM}$ were evaluated in order to determine fluence scaling factor hpl. Plastic phantom was evaluated for five electron energy from 6 MeV to 20 MeV. From the measured data of Palstic Water$^{TM}$, the fluence scaling factor hpl was found to be average 0.9964 and Virtual Water$^{TM}$ fluence scaling factor was 1.0156.

  • PDF

The Characteristics Analysis of New Dc 48[V] Telecommunication Power System using Forward Type three Phase Rectifier (포워드형 3선 PWM 정류기를 이용한 새로운 DC 48[V] 통신용 전원시스템의 특성 해석)

  • Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.34-40
    • /
    • 2006
  • This paper proposed power system for new DC 49[V] telecommunication using forward three-phase PWM rectifier power factor and efficiency for improvement of ripple voltage. Proposed power system for DC 48[V] telecommunication that consists of power conversion devices including switch, inductor and condenser were made between each line, in power inverter device of each switch control turn-on in period of continuity time control to get power factor '1' of sine wave current and on-off of switch lessens peak current that was happened and got conversion efficiency 92.1[%] composing in PWM rectifier of forward form instead of general PWM rectifier. Also, harmonic input regulation value(IEC61000-3-2 Class-As) satisfy input current and reduce ripple factor of output voltage in state that distortion of three-phase supply is overlapped each other.

Design and Electromagnetic Characteristics of Planar Transformer (평면변압기의 설계와 전자기적 특성)

  • Kim, Hyun-Sik;Lee, Hae-Yeon;Kim, Jong-Ryung;Oh, Young-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.3
    • /
    • pp.109-116
    • /
    • 2002
  • We designed the flyback planar transformer, which had 8 W capacity, with 70 V input voltage and 8.2 V output voltage for the establishment of design method and the confirmation of application possibility. The numerical value of inductance measured under the switching frequency of 120 kHz was 1650 $\mu$H, which was the inductance efficiency of'85∼87% against theoretical value. The A.C. resistance of primary and secondary coil was 4.2 Ω and 0.25 Ω respectively, On the other hand, the quality factor for each wound numbers showed quite a high value of 158 and 75 respectively. And the Coupling Factor was 0.96∼0.97 under 120 kHz switching frequency. The inductance rapidly increased as the thickness of the core plane increased until it became 1.4 mm but under the thickness more than 1.4 mm, there was no substantial change. Therefore, the critical value of the plane thickness of core was 1.4 mm. And the shape of the output wave of the planar transformer at 70V input voltage was a stable square wave.

A study on AC-powered LED driver IC (교류 구동 LED 드라이버 IC에 관한 연구)

  • Jeon, Eui-Seok;An, Ho-Myoung;Kim, Byungcheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.4
    • /
    • pp.275-283
    • /
    • 2021
  • In this study, a driver IC for an AC-powered LED that can be manufactured with a low voltage semiconductor process is designed and the performances of the driver IC were simulated. In order to manufacture a driver IC that operates directly at AC 220V, a semiconductor manufacturing process that satisfies a breakdown voltage of 500V or higher is required. A semiconductor manufacturing process for a high-voltage device requires a much higher manufacturing cost than a general semiconductor process for a low-voltage device. Therefore, the LED driver IC is designed in series so that it can be manufactured with semiconductor process technology that implements a low-voltage device. This makes it possible to divide and apply the voltage to each LED block even if the input voltage is high. The LED lighting circuit shows a power factor of 96% at 220V. In the pnp transistor circuit, a very high power factor of 99.7% can be obtained, and it shows a very stable operation regardless of the fluctuation of the input voltage.

Experimental Study on the Expression of Hair Growth Related Factors after Bee Venom Acupuncture Therapy (봉독약침요법(蜂毒藥鍼療法)에 의한 발모관련 인자들의 발현에 대한 연구)

  • Kim, Ho-Il;Kim, Cheong-Moo;Shin, Hyun-Jong;Lee, Chang-Hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.496-502
    • /
    • 2011
  • The present study was undertaken to investigate the effect of bee venom acupuncture therapy on the hair follicle growth by macroscopic, microscopic and immunohistochemical observation of skin 10 and 17 days after treatment. The results were as follows : Macroscopic hair follicle growth of 0.2 ml S.B.V. acupuncture treated group was more prominent than those of 0.1 ml S.B.V. acupuncture treated group and control group. Microscopic observation indicated that the hair follicle growth of control group reached anagen phase IV of hair growing cycle, and that of 0.1 ml and 0.2 ml S.B.V. acupuncture treated groups reached anagen phase VI and catagen, respectively. Immunohistochemical observations of the expression of various cytokines, enzymes and receptors in association with hair follicle cycle after local treatment of S.B.V. acupuncture therapy are as follows: Expression of fibroblast growth factor was more intense in epidermis and outer root sheath in 0.2 ml S.B.V. acupuncture treated group than that of 0.1 ml S.B.V. acupuncture treated group and control group. Expression of epidermal growth factor was more intense in bulge and outer root sheath in 0.2 ml S.B.V. acupuncture treated group than that of 0.1 ml S.B.V. acupuncture treated group and control group. Expression of c-kit receptor was more intense in epidermis, bulge and outer root sheath in 0.2 ml S.B.V. acupuncture treated group than that of control group. Expression of vascular endothelial growth factor was more intense in epidermis, bulge and outer root sheath in 0.2 ml S.B.V. acupuncture treated group than that of control group. Expression of protein kinase C-${\alpha}$ was more intense in epidermis, bulge and outer root sheath in 0.2 ml S.B.V. acupuncture treated group than control group. It is concluded that bee venom acupuncture therapy promoted the expression of various cytokines, enzymes and receptors related to the hair growth cycle for hair growth. This findings indicates that bee venom acupuncture therapy is applicable to the treatment of hair loss.

Microwave Dielectric Properties of Ultra-Low Temperature Co-firable Ba3V4O13-BaV2O6 Ceramics (Ba3V4O13-BaV2O6계 초저온 동시소성 세라믹스의 마이크로파 유전 특성)

  • Yoon, Sang-Ok;Hong, Seoyoung;Cho, Hyung-Hwan;Kim, Shin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.342-347
    • /
    • 2021
  • Phase evolution, sintering behavior, microstructure, and microwave dielectric properties of (1-x) mol Ba3V4O13 - (x) mol BaV2O6 system were investigated. The sintered specimens of all compositions consisted of Ba3V4O13 and BaV2O6, and no secondary phase was observed. As x increased, the linear shrinkage decreased to the composition of x=0.5, and then increased again, implying that Ba3V4O13 and BaV2O6 phases interfered mutually with each other during sintering. All compositions showed a dense microstructure with a large grain growth. Cracks were observed in some compositions because of the relatively high sintering temperature of 620~640℃. As x increased, the dielectric constant increased, while the quality factor was maintained from about 50,000 GHz to about 70,000 GHz up to the composition of x=0.9, and then decreased to 20,987~27,180 GHz at the composition of x=1.0. As x increased, the temperature coefficient of the resonance frequency showed a (+) value from a (-) value. The dielectric constant, the quality factor, and the temperature coefficient of resonant frequency of x=0.7 composition sintered at 640℃ for 4 hours were 10.61, 71,126 GHz, and -4.9 ppm/℃, respectively. This composition showed a good chemical compatibility with Al powder, indicating that the Ba3V4O13-BaV2O6 ceramics are a candidate material for ULTCC (Ultra-Low Temperature Co-fired Ceramics) applications.

Effect of V$_2$O$_5$ Addition on Microwave Dielectric Properties of (Zr$_{0.8}$,Sn$_{0.2}$)TiO$_4$ (V$_2$O$_5$의 첨가가 (Zr$_{0.8}$,Sn$_{0.2}$)TiO$_4$의 마이크로파 유전특성에 미치는 영향)

  • 이경호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.1
    • /
    • pp.27-32
    • /
    • 2001
  • The effect of $V_2O_5$, a donor-type dopant on the degradation of quality factor of ($Zr_{0.8}, Sn_{0.2})TiO_4$was compared with Ta$_2$O$_{5}$ doped ($Zr_{0.8}, Sn_{0.2})TiO_4$ in terms of microstructure, electrical conductivity, and oxidation state of the dopant. It is well known that the addition of the donor type species such as $Ta_2O_5,Nb_2O_5, Sb_2O_5, WO_{3}$, increases the quality factor of ($Zr_{0.8}, Sn_{0.2})TiO_4$due to decrease the oxygen vacancy concentration. Unlike other dopants, however, the addition of $V_2O_5$ decreased the quality factor. The degradation of quality factor of ($Zr_{0.8}, Sn_{0.2})TiO_4$was resulted from the formation of grain boundary phase and $V_2O_5$rich fiber shaped secondary phase, and the increasing the oxygen vacancy concentration due to unstability of oxidation state of vanadium ions in ($Zr_{0.8}, Sn_{0.2})TiO_4$ceramic.c.

  • PDF

Estimation on Affecting Factors and Contribution Rate for Air Permeability of Sawdust as Bulking Agent on Composting (퇴비화 첨가재인 톱밥의 공기투과성에 미치는 영향요인 및 기여도 평가에 관한 연구)

  • Kim, Byung Tae
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.4
    • /
    • pp.52-62
    • /
    • 2015
  • This study estimated the contribution rates of inlet air flow, moisture content, air-filled porosity and particle size on the total pressure drop for the sawdust used as the bulking agent in the composting. The statistical model for pressure drop including the affecting factors was proposed.($R^2=0.998{\sim}0.950$) While the laminar air flow(v) and particle size(SIZE*v) had the positive relations to the total pressure drop, the turbulent air flow($v^2$), moisture content(MC*v) and air-filled porosity(AFP*v) had the negative relations. Total pressure drop sharply increased with increasing of the inlet air flow. And the most significant factors affecting to total pressure drop were the particle size(SIZE*v) as positive factor and air-filled porosity(AFP*v) as negative factor. The contribution rate to total pressure drop by the particle size(SIZE*v) was continuously increased with increasing of the inlet air flow, but the contribution rate by air-filled porosity(AFP*v) was decreased. And total pressure drop was little changed even though the increasing of moisture content above the range of dry moisture content 0.25. The contribution rates of affecting factors had the different tendencies with increasing of the moisture content, especially in the negative factors as air-filled porosity(AFP*v) and moisture content(MC*v). For effective composting process, it is preferable to select the sawdust with higher air-filled porosity as bulking agent to enhance the air permeability.

The Response Modification Factor of Inverted V-type Braced Steel Frames (역V형 가새골조의 반응수정계수)

  • Ahn, Hyung Joon;Jin, Song Mei
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • In this study of Eccentric Braced Frames have identified the following target eccentricity on the length of the inelastic behavior of the reaction by calculating the correction factor by comparing it to the value suggested by the earthquake provided material for the rational design aims to There are. As a variable-length V-braced frame analysis model stations were set up. Eccentricity faults in the model according to the length stiffness ratio, the maximum amount of energy dissipation were analyzed base shear and multi-layered model of the reaction from the eccentricity correction factor calculated on the length of the building standards proposed by KBC 2009 in response eccentricity correction factor calculated from The length varies. does not have the same response modification factor was confirmed.