• Title/Summary/Keyword: V-곡선

Search Result 773, Processing Time 0.027 seconds

Thermoluminescence Kinetics of LYGBO Crystal (LYGBO 단결정의 열형광 전자포획준위 인자)

  • Sunghwan, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2023
  • In this study, the thermoluminescence kinetics of electron trap in Li6Y0.5Gd0.5(BO3)3 (LY0.5G0.5BO) scintillator for neutron detection composed of Li, Gd, and B with a high neutron response cross-section were investigated. The thermoluminescence glow curve of the LY0.5G0.5BO scintillation single crystal was measured and analyzed using the peak shape method, the initial rise method, and the machine learning algorithm to evaluate the physical parameters of the electron trap. The glow curve of the LY0.5G0.5BO scintillation single crystal consisted of a single peak. As a result of analyzing this peak, the activation energy, emission order, and frequency factor of the electron trap were 0.61 eV, 1.1, and 1.7×107 s-1, respectively. In addition, the possibility of thermoluminescence analysis of scintillators using machine learning was confirmed.

Efficiency Calibration of HPGe Detector in Normal ana Coincidence Mode for the Determination of Prompt Gamma-ray (즉발감마선 측정을 위한 HPGe 검출기의 전계수 또는 동시계수모드에서의 광대역 계측효율 보정)

  • 송병철;박용준;지광용
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.2 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy(NIPS) system measures the prompt gamma-ray emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many element in either solid or liquid wastes. In this study, the full-energy-peak (FEP) efficiency calibration for a HPGe detector was constructed in the ${\gamma}$-ray energy range from 80 keV to 8 MeV, using $^{l33}$Ba and >TEX>$^{152}Eu$ RI sources and $ ^{35}Cl(n, ${\gamma}$)^{36}Cl$ thermal neutron captured reaction. The FEP efficiency curve for the higher energies using the $^{35}Cl(n, ${\gamma}$)^{36}Cl$ reaction was normalized with the curve obtained from the RI sources, since the accurate activity of its prompt ${\gamma}$-ray is unknown. The average thermal neutron flux was theoretically calculated using the FEP efficiency curve for the KCl standard solutions. The NIPS system equipped with a ${\gamma}$-${\gamma}$ coincidence setup with two n-type coaxial HPGe detectors was considered in order to reduce the interfering ${\gamma}$-ray background. The FEP efficiency curve for the ${\gamma}$-${\gamma}$ coincidence system was also obtained for full energy range. The performance of the normal and coincidence NIPS system was tested by comparing signal-to-noise ratio in each mode using the reference sample.e.

  • PDF

Fracture Toughness Prediction of RPV Steels Using Crack Arrest Load of Load-Displacement Curve in Charpy V - Notch Impact Test (샤피 V - 노치 충격 하중-변위 곡선의 균열정지하중을 이용한 원자로압력용기강의 파괴인성 예측)

  • Park, Jeong-Yong;Kim, Ju-Hak;Lee, Yun-Gyu;Hong, Jun-Hwa
    • Korean Journal of Materials Research
    • /
    • v.10 no.4
    • /
    • pp.305-311
    • /
    • 2000
  • Applicability of crack arrest load measured from the Charpy V-notch impact test has been investigated to predict the fracture toughness of nuclear reactor pressure vessel (RPV) steels (ASME SA508 Cl.3). The temperature dependence of the crack arrest load was well described by the type of exponential function characterized by an index temperature at which the crack arrest load is 2kN. The specific index temperature, which also well correlated with $T_{NDT}\;and\;T_{41J}$ is expected to be representative index temperature characterizing the crack arrest fracture toughness of RPV steels. Also, the crack arrest load correlated well with the stable crack length measured from the fracture surface. From the measurements of the crack arrest load and the stable crack length, the lower bound fracture toughness, $K_{Ia}$ of RPV steels could be predicted with sufficient accuracy.

  • PDF

The Predicted Normal Value of Volume of Isoflow on Smokers and Nonsmokers (흡연자와 비흡연자에서 등기류용량(Volume of Isoflow)의 추정정상치에 관한 연구)

  • Park, Jung-Gook;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.2
    • /
    • pp.141-149
    • /
    • 1992
  • In order to establish predicted normal values of volume of isoflow($V_{iso}\dot{V}$), $V_{iso}\dot{V}$ were measured in a total 234 healthy adults, consisting of 78 male nonsmokers, 108 male smokers and 48 female nonsmokers. The volumes of isoflow were determined through analysis of maximal expiratory flow volume curves recorded with a mixture of 80% helium and 20% oxygen(He-$O_2$ gas) following one(1VC) and three vital capacity(3VC) maneuver and with room air. Based upon the correlation of the observed values of the parameters to age and physical characteristics, the following regression formulars for the prediction of the parameters, using age in year(A) as a variable, were obtained. 1VC method ($V_{iso}\dot{V}_1$) Male smoker : 0.614A+2.347 Male nonsmoker : 0.370A-2.792 Female nonsmoker : 0.588A-2.459 3VC method ($V_{iso}\dot{V}_3$) Male smoker : 0.467A+1.696 Male nonsmoker : 0.288A-1.538 Female nonsmoker : 0.367A-0.114.

  • PDF

Maximum Power Point Tracking Method Without Input side Voltage and current Sensor of DC-DC Converter for Thermoelectric Generation (열전발전을 위한 DC-DC Converter의 입력측 전압·전류 센서없는 최대전력점 추적방식)

  • Kim, Tae-Kyung;Park, Dae-Su;Oh, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.569-575
    • /
    • 2020
  • Recently, research on renewable energy technologies has come into the spotlight due to rising concerns over the depletion of fossil fuels and greenhouse gas emissions. Demand for portable electronic and wearable devices is increasing, and electronic devices are becoming smaller. Energy harvesting is a technology for overcoming limitations such as battery size and usage time. In this paper, the V-I characteristic curve and internal resistance of thermal electric devices were analyzed, and MPPT control methods were compared. The Perturbation and Observation (P&O) control method is economically inefficient because two sensors are required to measure the voltage and current of a Thermoelectric Generator(TEG). Therefore, this paper proposes a new MPPT control method that tracks MPP using only one sensor for the regulation of the output voltage. The proposed MPPT control method uses the relationship between the output voltage of the load and the duty ratio. Control is done by periodically sampling the output voltage of the DC-DC converter to increase or decrease the duty ratio to find the optimal duty ratio and maintain the MPP. A DC-DC converter was designed using a cascaded boost-buck converter, which has a two-switch topology. The proposed MPPT control method was verified by simulations using PSIM, and the results show that a voltage, current, and power of V=4.2 V, I=2.5 A, and P=10.5 W were obtained at the MPP from the V-I characteristic curve of the TEG.

Numerical Verification of HWAW Method in the Near Field (근거리장에서 HWAW 기법의 수치해석적 검증)

  • Bang, Eun-Seok;Park, Hyung-Choon;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.2
    • /
    • pp.5-17
    • /
    • 2007
  • Various field setup and filtering criteria have been suggested to avoid the near field effects in surface wave methods. Unlike other surface wave methods HWAW method uses the near field component positively. It is possible by using maximum energy point based on time-frequency map and inversion method to consider receiver locations from the source point and body wave component. To verify the HWAW method in the near field numerical study was performed and the wave propagation in the stratified soil media was simulated due to a surface point load. All of five representative soil models were used. The experimental dispersion curves, determined by HWAW method at the various receiver distances in the region of near field, all coincided well with the theoretical dispersion curves determined by 3D forward modeling (Kausel's method). Consequently, it was considered that the HWAW method can provide reliable $V_s$ profiles effectively in the near field.

The Structures and Dielectric Properties of Plasma Polymerized Polyethylene (플라즈마 중합 폴리에틸렌 구조와 유전특성)

  • 김두석
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.3
    • /
    • pp.38-42
    • /
    • 2000
  • Plasma polymerized thin films were manufactured inter-electrode coupled plasma polymerization apparatus. The deposition rate reached its maximum between 40[W] and 100[W]. In the ESCA analysis, peaks revealing -CH2, -CH, -C- were present at 285.4 and 285.5[eV] respectively. The C=O peak at 532.8[eV] and the C-O peak at 533.8[eV], which were grouped with an unignorable amount of oxygen were conformed. In ESR analysis, the curve revealing strong amplification was in saturation, which was affected by weak power. This is considered as a -CH-Ch=Ch- structure containing the Allyl group. The relative permittivity of the plasma polymerized thin films was about 3.5 at a frequency of 100[Hz]∼200[kHz]. The dissipation factor showed allow value of 0.008.

  • PDF

Study on Parallel Processing of ECDSA Verification for V2X Communication (V2X 통신을 위한 ECDSA 서명 검증 병렬처리 연구)

  • Lee, Sokjoon;Choi, Joongyong;Chung, Byungho;Kwon, Hyeokchan
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.10a
    • /
    • pp.216-217
    • /
    • 2018
  • IEEE 1609.2 표준은 WAVE (Wireless Access in Vehicular Environment) 표준에서 차량간(V2V, Vehicle-to-Vehicle) 혹은 차량과 인프라간(V2I, Vehicle-to-Infrastructure)통신 상의 응용 메시지 보호를 위해 제정되었다. 이 표준은 메시지 이증 및 무결성 검증을 위하여 NIST p256 타원 곡선 커브 기반의 ECDSA 전자서명 기법을 사용한다. 매우 복잡한 도신 상의 출퇴근 환경에서는 수백대의 자동차가 전송하는 메시지를 정상적으로 처리하기 위하여, 차량의 OBU(On-Board Unit) 혹은 노상의 RSU(Road-Side Unit)에서 서명된 메시지의 검증 성능이 매우 중요한 이슈가 될 수 있다. 본 논문에서는 V2X 통신에서 효율적인 ECDSA 서명 검증을 위하여, OBU 혹은 RSU 환경에서 CPU 상의 병렬 처리 성능을 테스트 한 후 시사점을 살펴본다.

CHARACTERISTICS OF THE PALATAL MORPHOLOGY OF THE CHILDREN WITH CROSSBITE IN MIXED DENTITION BY 3-DIMENSIONAL LASER SCANNER (3차원 스캐너를 이용한 혼합치열기 반대교합아동의 구개형태에 관한 연구)

  • Kim, Dong-Won;Park, Ho-Won
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.132-142
    • /
    • 2003
  • This study is performed to investigate the characteristics of the palatal morphology of the children with anterior crossbite in Hellman dental age IIIA by 3-dimensional laser scanner. Totally 40 study casts were taken; 20 were from children with crossbite and another 20 were from normal occlusion as a control. Each cast was scanned by 3 dimension laser scanner and shaped by the 3 dimension image by rapidform 2000 program(INUS, Korea). And finally it was calculated by Rhino 3D program(Rhinoceros, USA). The intercanine, intermolar cross-sectioned transverse plane and sagittal plane were measured. Due to the variations in palatal morphology, each group was standardized into 25mm, 35mm, 35mm. By sectioning standardized curves of the Palatal morphology per 1mm, the palatal depth of each point was calculated. Through these complex methods, the mean curves of the palatal morphology could be obtained and the values were statistically compared and evaluated by T-test with 95% of significance level. The results were as follows: 1. In the intercanine cross-sectioned transverse plane, the mean curve of palatal morphology of crossbite group was flatter V shape than that of control group, however, there was no statistical significance was found between two groups(P>0.05). 2. In the intermolar cross-sectioned transverse plane, the mean curve of palatal morphology of crossbite was deeper all over the area than that of control group, and the statistical significance was found in the middle area from point 8 to 21(P<0.05). 3. In the sagittal plane, the mean curve of palatal morphology of crossbite group was more deepening as approaching posteriorly than that of control group, and the statistical significance was found in all over the area(P<0.01).

  • PDF

Evaluation on Material Properties of 3Cr-lMo-0.25V Steel by Electromagnetic Methods (전자기법을 이용한 3Cr-lMo-0.25V 강의 물성 평가)

  • Nam, Young-Hyun;Ahn, Bong-Young;Lee, Seung-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.2
    • /
    • pp.255-261
    • /
    • 2003
  • It is advantageous to use NDE methods to assess the mechanical properties of materials since the conventional method is time-consuming and sometimes requires cutting of sample from the component. The NDE parameters such as ultrasonic velocity and attenuation, electric resistivity, and magnetic coercive force and remanance have been utilized to evaluate changes of material properties due to heat treatment condition. It has been found that changes of materials properties under quenched and tempered/PWHT treatments could not be detected using EMAT and Electrical resistivity methods. However, victors hardness and magnetic hysteresis loop decreased with heat treatment procedures. These results were obtained using 3Cr-lMo-0.25V steel. The magnetic parameters were found to be most sensitive to changes of material properties.