Design of a Frequency Synthesizer for UHF RFID Reader Application (UHF 대역 RFID 리더 응용을 위한 주파수합성기 설계)

  • Kim, Kyung-Hwan;Oh, Kun-Chang;Park, Jong-Tae;Yu, Chong-Gun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.5
    • /
    • pp.889-895
    • /
    • 2008
  • In this paper a Fractional-N frequency synthesizer is designed for UHF RFID readers. It satisfies the ISO/IEC frequency band($860{\sim}960MHz$) and is also applicable to mobile RFID readers. A VCO is designed to operate at 1.8GHz band such that the LO pulling effect is minimized. The 900MHz differential I/Q LO signals are obtained by dividing the differential signal from an integrated 1.8GHz VCO. It is designed using a $0.18{\mu}m$ RF CMOS process. The measured results show that the designed circuit has a phase noise of -103dBc/Hz at 100KHz offset and consumes 9mA from a 1.8V supply. The channel switching time of $10{\mu}s$ over 5MHz transition have been achieved, and the chip size including PADs is $1.8{\times}0.99mm^2$.

Localization of partial discharge in power transformer by detecting UHF PD signal (UHF 부분방전 신호를 이용한 전력용 변압기 내부의 부분방전 위치 추정)

  • Ju, Hyung-Jun;Goo, Seun-Gun;Han, Ki-Sun;Park, Ki-Jun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.147-148
    • /
    • 2008
  • In this paper two kinds of techniques were compared for localization of PD(partial discharge) in power transformer and more useful method was suggested. Both of them, the time of arrival and the energy content method, were tested in 154kV single phase experimental transformer using UHF signal measurement. The former was using the difference of arrival time of recorded signals from four UHF sensors, the latter was based on the energy content in frequency spectra of signals detected at all sensors.

  • PDF

Ultra-wide bandwidth versus narrow bandwidth PD detection techniques for UHF partial discharge monitoring system (초광대역과 단일주파수(협대역) UHF 부분방전 검출기법 비교)

  • Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1655-1657
    • /
    • 2002
  • Ultra-wide bandwidth (UWB), narrow bandwidth (single frequency), and a combination of both technologies have been studied for the ultra-high frequency (UHF) partial discharge (PD) monitoring system as a detection scheme. We have experimentally compared those detection methods using a mock-up of 362 kV class single phase gas-insulated switchgear (GIS) and a stable PD source. A rolling-ball type PD cell that produces PDs of about 10 pC, is placed at one end of the GIS. An internal UHF PD sensor was attached several meters away from the PD source. The PD spectrum was measured up to 3 GHz. A useable bandwidth of more than 1 GHz was used to measure UWB signals from the PD. To simulate the narrow bandwidth scheme a bandwidth of 100 kHz centered at several different frequencies was used.

  • PDF

Partial Discharge Detection on Site GIS Using UHF Technique (GIS 부분방전 검출을 위한 UHF 신호측정법 현장 적용)

  • Yoon, Jin-Yeol;Park, Ki-Jun;Goo, Sun-geun;Jo, Sung-Hoon;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1915-1917
    • /
    • 2000
  • Laboratory experiments and on site measurements were conducted to detect partial discharges in GIS(Gas Insulated Switchgear) using the UHF(Ultra High Frequency) technique that has been applied many places in the world. Experimental results were in good agreement with calculation in locating a partial discharge source using mock-up GIS. Defect type and its location were inferred after a measurement on 345 kV GIS that showed some abnormal phenomenon. Precise examination inside the GIS coincided with the results inferred from the measurement. High reliability of UHF technique for site application was confirmed.

  • PDF

Design of a Wireless Self-Powered Temperature Sensor for UHF Sensor Tags (무선 전력 구동 센서 태그 내장형 온도센서의 설계)

  • Kim, Hyun-Sik;Cho, Jung-Hyun;Kim, Shi-Ho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.10
    • /
    • pp.1-6
    • /
    • 2007
  • Wireless Self-Powered Temperature Sensor for UHF Sensor Tags which are basic device for construction of ubiquitous sensor network is proposed. The key parameters of the target specification are resolution of $0.1\;^{\circ}C$ per output bit, below 1.5 V of operating voltage and below 5 uW of power consumption during sensing operation. Temperature sensor circuit consists of PTAT current generator, band gap reference circuit generating both reference voltage and current, Sigma-Delta Converter, and Digital Counter. Simulated maximum resolution was $0.23\;^{\circ}C/bit$ in 11-bit output. The proposed temperature sensor was fabricated by using a 0.25 m CMOS process. The chip area is $0.32\;{\times}\;0.22\;mm$ and the operating frequency is 2 MHz. Measured resolution from fabricated temperature sensor was $4\;^{\circ}C/bit$ in 8-bit output for the temperature range from $10^{\circ}C$ to $80^{\circ}C$.

A Study on Estimation of Breakdown Location using UHF Sensors for Gas Insulated Transmission Lines (UHF센서를 이용한 가스절연송전선로 절연파괴 위치 추정에 관한 연구)

  • Park, Hung-Sok;Han, Sang-Ok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.805-810
    • /
    • 2011
  • This paper deals with the method and algorithm used to find fault locations in gas insulated transmission line. The method uses UHF sensors and digital oscilloscope to detect discharge signals emitted to the outside through insulating spacer in the event of breakdown inside GIL. UHF sensors are the external type and installed at outside of insulating spacers of GIL. And we used wavelet signal processing to analyze the discharge signals and confirm the exact fault location findings in the GIL test line. This method can overcome demerit of TDR(Time Domain Reflectometer) method having been applied to detect fault location for conventional underground transmission lines, and Ground Fault Sensors used in conventional GIS systems. TDR method requires high level of specialty and experience in analyzing the measured signals. Ground fault sensors are installed inside GIL and can be destroyed by high transient voltage. This paper's method can simplify the fault location process and minimize the damage of sensors. In addition, this method can estimate the fault location only by the time difference when discharge signals are arrived to detecting sensors at the ends of GIL sections without reasons of breakdown. To test the performance of our method, we installed sensors at the ends of test line of GIL(84m) and sensed discharge signals occurred in GIL, energized with AC voltage generator up to 700kV.

Low-Power 512-Bit EEPROM Designed for UHF RFID Tag Chip

  • Lee, Jae-Hyung;Kim, Ji-Hong;Lim, Gyu-Ho;Kim, Tae-Hoon;Lee, Jung-Hwan;Park, Kyung-Hwan;Park, Mu-Hun;Ha, Pan-Bong;Kim, Young-Hee
    • ETRI Journal
    • /
    • v.30 no.3
    • /
    • pp.347-354
    • /
    • 2008
  • In this paper, the design of a low-power 512-bit synchronous EEPROM for a passive UHF RFID tag chip is presented. We apply low-power schemes, such as dual power supply voltage (VDD=1.5 V and VDDP=2.5 V), clocked inverter sensing, voltage-up converter, I/O interface, and Dickson charge pump using Schottky diode. An EEPROM is fabricated with the 0.25 ${\mu}m$ EEPROM process. Power dissipation is 32.78 ${\mu}W$ in the read cycle and 78.05 ${\mu}W$ in the write cycle. The layout size is 449.3 ${\mu}m$ ${\times}$ 480.67 ${\mu}m$.

  • PDF

noise discrimination case of UHF partial discharge signal in GIS (변전소 GIS에서 UHF 부분방전신호의 노이즈 판별 사례)

  • Kim, Kyung-Tak;Goo, Sun-Geun;Han, Ki-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.145-146
    • /
    • 2008
  • OO변전소 154 kV GIS에서 부분방전측정 수행을 하였다. GIS내부 결함유무 및 위치를 판정하기 위해 현장 정밀측정을 한 결과 GIS 내부에서 발생하는 부분방전신호가 아닌 외부노이즈임을 세가지 측정방법을 통해 판별할 수 있었다.

  • PDF

Design of V/UHF band Small Dipole Circular Array Active Antenna (V/UHF대역 소형다이폴 원형배열 능동안테나 설계)

  • Ko, Ji-Hwan;Lee, Cheol-Soo;Kim, Kang-Uk;Cho, Young-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.1
    • /
    • pp.6-16
    • /
    • 2009
  • For the application to the direction finding(DF) antenna for V/UHF bands, circular active array composed of 9 dipole element has been investigate. For miniaturization of the overall size array, the element has been chosen to be of the top-hat dipole type. For the broadband operation over 20-1300MHz, some number of pin diodes have been inserted in each arms of each dipole element. By employing this type of each element dipole, the effective dipole length can be increased or decreased according as the inserted pin diodes is on or off. The active array antenna has been design to be directly connected to the balanced push full amplifier such that the amplifier may play a role as a balloon and may improve the sensitivity as a receiver as well. The active array antenna has been designed and fabricated. Some experimental results have been presented in comparison with simulated results.

Analysis of Partial Discharge Signal Propagation Characteristics in GIS Using FEM (FEM을 이용한 GIS내 부분방전 신호의 전파특성 해석)

  • Lee, D.H.;Lee, H.D.;Lee, Y.H.;Park, K.H.;Ryu, K.Y.;Sin, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1835-1837
    • /
    • 2004
  • The UHF electromagnetic waves excited by PD pulses propagate along the GIS busbar not only TEM mode, but also TE and TM mode. Generally the waves detected by the UHF sensors are those of high order modes and such waves can only propagate the higher than cut-off frequency. In this paper, computed cut-off frequency of 362[kV] GIS by each modes and simulated electromagnetic field of each propagation modes by FEM(Finite Element Method) program. Frequency band of each TEmn/TMmn modes were determinated by simulation results and were discussed optimal position of UHF sensor from this results.

  • PDF