• Title/Summary/Keyword: V/H ratio

Search Result 951, Processing Time 0.026 seconds

The Duration and H/V ratio of the Ground Motion in Southern Korea (남한 지진의 지속시간과 H/V 비율)

  • 최호선;박창업;조남대
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.42-50
    • /
    • 2002
  • The duration and H/V ratio(the amplitude ratio of the horizontal to vertical components) of ground motions caused by earthquakes in southern Korea are analyzed. Total 329 seismograms of horizontal component recorded at hypocentral distances of 10 to 350 km from 27 earthquakes with local magnitude 2 to 4 are used for the analysis. Simplified relation between the duration of ground motion( $T_{d}$) and the ratio($\chi$) of Arias intensity( $I_{A}$) and squared maximum acceleration($\alpha$$_{max}$$^{2}$) is determined to be $T_{d}$ = 3.423$\chi$$^2$+ 8.200$\chi$ + 0.029, which is useful for the estimation of the duration in southern Korea. There are three distinct distance ranges with different linear variations of the duration in hypocentral distance. They are distance intervals of 10~80km, 80~140km, and the distance greater than 140km. The duration in southern Korea shows clear proportionality to the local magnitude at magnitudes greater than 3.1. The value 1.37 of the H/V ratio obtained in southern Korea is similar to the value 1.4 of ENA(Eastern North America). The H/V ratio in southern Korea increases in the frequency range from 0.3 to 10Hz. The duration and H/V ratio of ground motions derived in this study could be used in the stochastic simulation of strong ground motion.ion.n.n.

  • PDF

The Effect of Pile Length on the Handle and Physical Properties of Velvet (Velvet의 pile 길이가 촉감 및 물리적 특성에 미치는 영향)

  • 장정애;류덕환
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.3
    • /
    • pp.471-482
    • /
    • 1995
  • Using the acetate velvet and viscose velvet whose pile lengths were sheared as 1.45, 1.55, 1 65, 1.75, 1.85, 1.90mm under the condition equating the weaving process of ground fabric, the conclusions were as follows through the results of the sensory assessments estimated by women students in our university and the physical properties, H. V and T. H. V obtained by KES-F system. 1. In the sensory assessments estimated by the method of paired comparison and ranking of samples, the longer pile length was, the more the hand values of smoothness, softness, thickness, heaviness increased on the whole. 2. The H V. and T. H. V. measured by KES-F system were as follows; Kohi increased to pile length 1.85mm and then decreased a little at 1.90mm. hummer increased as pile length was longer. Fukurami increased to pile length 1.75mm and then decreased gradually as pile length was longer. Total hand value increased gradually from 1. 45mm to 1.85mm, had the top value at 1.85mm, and then decreased a little at 1.90mm. 3. In the results of summarizing $\ulcorner$the physical properties correlated closely with the H. V obtained by sensory assessments$\lrcorner$ and tithe Physical properties correlated closely with the H. V. and T. H. V obtained by KES-F systems, it showed that all the sensory properties correlated closely with compressive energy, flexural rigidity, thickness, weight and pile ratio in the former and that the physical properties correlated closely with each H V and T. H. V were different in the latter. 4. It showed that factor 1 was related to compressive energy, thickness, weight, pile ratio, factor 2 was related to recovery energy, compressive resilience, compressive index, and factor 3 was related to compressive recovery ratio in the result of factor analysis. 5. In the multiple repression analysis, the expressions of all sensory properties had compressive ratio, frictional coefficient in the regression expressions of $\ulcorner$H. V. obtained by sensory assessments$\lrcorner$, while the expressions of each H. V. and different physical properties in the regression expressions of $\ulcorner$H. V. obtained by KES-F system$\lrcorner$.

  • PDF

Water Addition Ratio Affected Texture Properties of Cooked Rice (취반 가수율에 따른 품종별 쌀밥의 텍스쳐 특성)

  • 이수정
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.25 no.5
    • /
    • pp.810-816
    • /
    • 1996
  • This study was conducted to measure the hydration characteristics at $20^{\circ}C$ and investigated the effect of water to rice ratio(v/w) on the texture properties of cooked rice of ten different varieties based on maturity. Water absorptions during soaking were completed between 30min and 35min at $20^{\circ}C$. The ranges of equilibrium moisture content were between 0.3247g $H_2O/g$ dry matter and 0.3577g H201g dry matter. During the cooking process, the water content of cooked rice increased 6~7% with increased the ratio of water to rice from 1.4 to 1.6(v/w). The hardness(H) of cooked rice decreased, while the stickiness(-H) and -H/H ratio increased with increased ratio of water to rice.

  • PDF

The effects of vertical earthquake motion on an R/C structure

  • Bas, Selcuk;Kalkan, Ilker
    • Structural Engineering and Mechanics
    • /
    • v.59 no.4
    • /
    • pp.719-737
    • /
    • 2016
  • The present study investigated the earthquake behavior of R/C structures considering the vertical earthquake motion with the help of a comparative study. For this aim, the linear time-history analyses of a high-rise R/C structure designed according to TSC-2007 requirements were conducted including and excluding the vertical earthquake motion. Earthquake records used in the analyses were selected based on the ratio of vertical peak acceleration to horizontal peak acceleration (V/H). The frequency-domain analyses of the earthquake records were also performed to compare the dominant frequency of the records with that of the structure. Based on the results obtained from the time-history analyses under the earthquake loading with (H+V) and without the vertical earthquake motion (H), the value of the overturning moment and the top-story vertical displacement were found to relatively increase when considering the vertical earthquake motion. The base shear force was also affected by this motion; however, its increase was lower compared to the overturning moment and the top-story vertical displacement. The other two parameters, the top-story lateral displacement and the top-story rotation angle, barely changed under H and H+V loading cases. Modal damping ratios and their variations in horizontal and vertical directions were also estimated using response acceleration records. No significant change in the horizontal damping ratio was observed whereas the vertical modal damping ratio noticeably increased under H+V loading. The results obtained from this study indicate that the desired structural earthquake performance cannot be provided under H+V loading due to the excessive increase in the overturning moment, and that the vertical damping ratio should be estimated considering the vertical earthquake motion.

Changes in the Spinal Motor Neuron Excitability Depending on Postural Changes in Post Stoke Hemiplegics (뇌졸중 후 편마비 환자의 체위변화에 따른 척수운동신경원 흥분성 변화)

  • Park, Young-Hyun;Kim, Yong-Nam;Kim, Su-Hyon;Oh, Seok;Choi, Ji-Ho;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.4
    • /
    • pp.15-20
    • /
    • 2010
  • Purpose: The purpose of this study was to measure changes in the H-reflex and V wave under loading conditions (e.g. prone and standing position) and to investigate whether postural change would affect the H-reflex and V wave in post stroke hemiplegic patients. Methods: Thirty persons with hemiplegia resulting from stroke (20 males, 10 females) participated in this study. Electromyography (EMG) was used to electrically stimulate and record the soleus H-reflexes and V waves under various loading conditions. The normality of the distribution of each variable (H latency, $H_{max}/M_{max}$ ratio, $V_{max}/M_{max}$ ratio) was tested using the Kolmogorov-Smirnov test. The means of normally distributed continuous data were assessed by independent t-test (${\alpha}$=0.05). Results: There were statistically significant differences in $H_{max}/M_{max}$ ratio (p<0.01), $V_{max}/M_{max}$ ratio (p<0.01), H latency (p<0.01) among the prone and standing position. Conclusion: We found that the H-reflex and V wave in standing position was more active to weight bearing load than prone position.

Design of CVT Composed of a K-H-V type Differential Gear Unit and a V-Belt Drive (K-H-V형 차동기어장치와 V-벨트식 기구를 결합한 무단변속기의 설계)

  • 김연수;박재민;정찬길;최상훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.799-802
    • /
    • 2002
  • Continuously variable transmission(CVT) mechanisms considered here combine the functions of a K-H-V type differential gear unit and a V-belt type continuously variable unit(CVU). As combining the functions of a K-H-V type differential gear unit and a V-belt type CVU, 24 different mechanisms are presented. Some useful theoretical formula related to speed ratio, power flow and efficiency are derived and analyzed. These mechanisms have many advantages which are the decrease of CVT size, the increase of overall efficiency, the extension of speed ratio range, and the generation of geared neutral.

  • PDF

A Study on Characteristics of Sn-37Pb and Sn-4.0Ag-0.5Cu Solder Joints as Various A:V Ratio (A:V Ratio 변화에 따른 Sn-37Pb, Sn-4.0Ag-0.5Cu Solder 접합부의 특성 연구)

  • Han, Hyun-Joo;Lim, Seok-Jun;Moon, Jung-Tak;Lee, Jin
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2001.11a
    • /
    • pp.67-73
    • /
    • 2001
  • To investigate the relationships of solder joint characteristics with solder composition and A:V ratio (solder volume per pad area), Sn-37Pb and Sn-4.0Ag-0.5Cu solder balls with 330, 400, 450 and $457{\mu}{\textrm}{m}$ size were reflowed on same substrate. Sn-37Pb and Sn-4.0Ag-0.5Cu was reflowed at $220^{\circ}C$ and $240^{\circ}C$ respectively by IR-type soldering machine. As a result of reflowed solder- ball diameter(D) and height(H) measurement, D/H was decreased with solder ball size increment in range of 330~450 ${\mu}{\textrm}{m}$. But, D/H was increased in the solder joint for 457 ${\mu}{\textrm}{m}$ size, it was caused possibly by decrement of solder ball height increment compared with solder volume increment. As a result of shear and pull test, joint strength with A:V ratio was high. Joint strength of Sn-4.0Ag-0.5Cu was higher than Sn-37Pb. However, Sn-37Pb had more stable solder joint of small standard deviation. A thick and clean scallop type Ni-Cu-Sn intermetallic compound layer was formed in high A:V ratio and Sn-4.0Ag-0.5Cu solder joint interface.

  • PDF

ANALYTIC EXPRESSION OF HYDRAULIC FALL IN THE FREE SURFACE FLOW OF A TWO-LAYER FLUID OVER A BUMP

  • Park, Jeong-Whan;Hong, Bum-Il;Ha, Sung-Nam
    • Communications of the Korean Mathematical Society
    • /
    • v.12 no.2
    • /
    • pp.479-490
    • /
    • 1997
  • We consider long nonlinear waves in the two-layer flow of an inviscid and incompressible fluid bounded above by a free surface and below by a rigid boundary. The flow is forced by a bump on the bottom. The derivation of the forced KdV equation fails when the density ratio h and the depth ratio $\rho$ yields a condition $1 + h\rho = (2-h)((1-h)^2 + 4\rho h)^{1/2}$. To overcome this difficulty we derive a forced modified KdV equation by a refined asymptotic method. Numerical solutions are given and hydraulic fall solution of a two layer fluid is expressed analytically in the case that derivation of the forced KdV (FKdV) equation fails.

  • PDF

Analysis of Site Amplification Characteristics of Several Seismic Stations Distributed in the Southern Korean Peninsula (국내 지진관측소 부지의 지반증폭특성 연구)

  • Kim, Jun-Kyoung
    • Tunnel and Underground Space
    • /
    • v.16 no.6 s.65
    • /
    • pp.486-494
    • /
    • 2006
  • The horizontal to vertical (H/V) ratio technique in spectral domain is a common useful technique to estimate empirical site transfer function. The technique, originally proposed by Nakamura, is proposed to analyse the surface waves in the micrortremor records. The purpose of this paper is to estimate spectral ratio using observed data at the seismic stations distributed within Southern Korean Peninsula from the Fukuoka earthquake including 11 aftershocks. The results show that most of the stations have fairly good amplification characteristics in low frequency band. However, some of the seismic stations show one (resonant frequency specific to the site) or several local peaks of amplification factors with narrow high frequency band. Even though the site amplification characteristics are important information, we should be careful to analyse the observed ground motions from the seismic stations which have several very high amplification peaks for the deconvolution of seismic source and attenuation parameters.