• 제목/요약/키워드: V/C ratio

검색결과 1,325건 처리시간 0.03초

접근로별 포화도를 고려한 Roundabout Signal Metering 운영방법에 관한 연구 (Roundabout Signal Metering Operation Methods by Considering Approach Lane's Degree of Saturation)

  • 안우영;이소영
    • 한국도로학회논문집
    • /
    • 제15권5호
    • /
    • pp.217-226
    • /
    • 2013
  • PURPOSES : Under the capacity conditions with balanced approach flows, roundabouts give less delay than existing signalized intersections; however, flows over 450 vehicles/hour/lane with unbalanced approach flow conditions, roundabouts efficiency drops due to the short time difference between the critical gap and the follow-up headway. The purpose of this study is developing a roundabout Signal Metering operation method by considering approach lanes degree of saturation. METHODS : A four-way-approach with one-lane roundabout is selected to compare the Signal Metering performance for the case of 16 different unbalanced flow conditions. Based on these traffic conditions, the performance is evaluated for 64 different cases of Signal Metering combinations by using SIDRA software. A degree of saturation(V/C ratio) sum for two adjoined approaches is used for the performance index of choosing Metered Approach and Controlling Approach. RESULTS : When the V/C ratio sum is 0.29~0.81 and Metered Approach flow is less than Controlling Approach flow, the average delay saving per vehicle is about 7 seconds; however, after this rage the delay saving decreases gradually until the V/C ratio sum reaches around 1.0. The range of V/C ratio sum 0.93~1.09 provides average delay saving per vehicle about 3 seconds. In case of V/C ratio sum is grater than 1.0 and the flows of Metered Approach is grater than Controlling Approach, the average delay per vehicle increases 3~11 times respectively. CONCLUSIONS : As expected, the Signal Metering provides substantial improvements in delay saving for the case of V/C ratio sum is 0.3~1.0 under the traffic flow conditions of Metered Approach is less than Controlling Approach.

연직드레인 공법에 의한 연약지반의 압밀거동 (Consolidation Behavior of Soft Ground by Prefabricated Vertical Drains)

  • 이달원;강예묵
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.376-381
    • /
    • 1998
  • The large scaled field test by prefabricated vertical drains was performed to evaluate the superiority of vertical discharge capacity for drain materials through compare and analyze the time-settlement behavior with drain spacing and the compression index and consolidation coefficient obtained by laboratory experiments and field monitoring system 1. The relation of measurement settlement( $S_{m}$) versus design settlement( $S_{t}$) and measurement consolidation ratio( $U_{m}$) versus design consolidation ratio( $U_{t}$) were shown $S_{m}$=(1.0~l.1) $S_{t}$, $U_{m}$=(1.13~l.17) $U_{t}$, at 1.0m drain spacing and $S_{m}$=(0.7~0.8) $S_{t}$, $U_{m}$=(0.92~0.99) $U_{t}$ at 1.5m drain spacing, respectively. 2. The relation of field compression index( $C_{cfield}$) and virgin compression index( $V_{cclab}$) was shown $C_{cfield}$=(1.0~1.2) $V_{cclab}$, But it was nearly same value when considered the error with determination method of virgin compression index and prediction method of total settlement. 3. field consolidation coefficient was larger than laboratory consolidation coefficient, and the consolidation coefficient ratio( $C_{h}$/ $C_{v}$) were $C_{h}$=(2.4 ~ 3.0) $C_{v}$. $C_{h}$=(3.5 ~ 4.3) $C_{v}$ at 1.0m and 1.5m drain spacing and increased with increasing of drain spacingngasing of drain spacingng spacingng

  • PDF

장방형 기둥-슬래브 접합부의 이력거동에 대한 철근비의 영향 (Influence of Reinforcement Ratio on the Hysteratic Behavior of Rectangle Column-Slab Connection)

  • 조인중;최명신;신성우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.53-56
    • /
    • 2008
  • 본 연구는 주거용 고층 건물에서 폭넓게 사용되고 있는 플랫 플레이트 구조에서 장방형 기둥-슬래브 접합부를 대상으로 실시한 6개의 실험결과를 분석한 것이다. 연구의 목적은 지진하중과 같이 반복적으로 작용하는 횡하중에 대하여 기둥 단면의 형상비(${\beta}$c=$c_1/c_2$)에 따른 접합부의 이력거동을 비교 평가 하는 것이다. 기둥 형상비는 $b_o$가 일정해 지도록 0.33${\sim}$3($c_1/c_2$=1/3, 1/1, 3/1)으로 선정하였다. 슬래브 휨철근비는 1.0%, 1.5%로 변화시켰으며, 중력전단력비($V_g/V_c$) 등 접합부의 이력거동에 영향을 줄 수 있는 다른 영향인자들은 일정한 조건으로 계획하여 기둥 형상비의 영향을 고찰할 수 있도록 하였다. 실험을 통해서 뚫림전단파괴 양상과 균열 패턴, 접합부의 강성, 변형능력 등을 변수에 따라 분석하였다.

  • PDF

식생모듈박스를 이용한 저토심 무관리형 옥상녹화 - 토양 배합비가 식물생육에 미치는 영향을 중심으로 - (Roof Greening applied a Sallow Green Roof Module System Out of Management - Focused on the Effects on the Growth of Plants by Difference of Soil Mixture Ratio -)

  • 강태호;조홍하;이홍;강성훈
    • 한국조경학회지
    • /
    • 제40권3호
    • /
    • pp.91-98
    • /
    • 2012
  • 본 연구는 저토심 무관리형 옥상녹화시스템을 위한 토양배합이 세덤류 생육에 미치는 영향을 연구하여 생육 적정성 토양배합을 파악하고자 하였다. 식생모듈박스를 이용하여 토심 7cm, 5종 토양배합비가 있어 2010년 12월부터 5층 옥상에서 실시하였다. 식물의 생육현황은 P5C7P2V1이 가장 우수한 것으로 나타났으며, 다음으로 P10C7P2V1과 P1P1V1, P1과 C1의 생육이 가장 저조한 것으로 나타났다. 실험 경과, P5C7P2V1의 토양배합비에서 효과가 가장 양호하게 나타나, 도시내 대면적 녹화에 기여할 수 있는 토양배합비로 판단된다.

고속도로 시설물 구간의 교통혼잡도와 사고율의 관계 분석 (신갈-안산 고속도로를 중심으로) (Relationship between V/C and Accident Rate for Freeway Facility Sections (focused on Shingal-Ansan Freeway))

  • 오철;장재남;장명순
    • 대한교통학회지
    • /
    • 제17권2호
    • /
    • pp.21-27
    • /
    • 1999
  • 고속도로 시설물 구간의 교통혼잡도(V/C)와 사고율의 관계를 분석하는 것이 본 연구의 목적이다. 본 연구에서 분석된 사고율과 V/C의 관계는 교통사고의 예측과 예방을 위한 기초 자료로 유용하게 쓰일 수 있을 것으로 판단된다. 본 연구에서는 신갈-안산간 고속도로의 개통시(92년)부터 97년까지의 교통량과 사고 자료를 이용하였으며, 시간당 사고율과 V/C를 계산하여 기본구간, 터널구간, 영업소구간의 V/C와 사고율(AR)을 비교·분석하였다. V/C와 사고율의 관계는 모든 구간에서 "U"형의 곡선 형태를 나타냈다. 분석 결과를 보면 V/C가 낮을 때 사고율이 가장 높았으며 V/C가 증가함에 따라 사고율이 감소하다가 일정수준 이상에서는 다시 사고율이 증가하는 것으로 나타났다. 영업소구간의 사고율이 V/C의 전 범위에 걸쳐 기본구간이나 터널구간보다 높게 나타났다. 터널구간의 경우 기본구간과 비교 시 V/C=0.67을 기준으로 그 이하에서는 기본구간이, 그 이상에서는 터널구간이 기본구간보다 사고율이 높은 것으로 분석되었다. V/C가 0.5∼0.8 구간에서는 기본구간과 터널구간의 사고 율이 큰 차이가 없는 것으로 나타났다. 기본구간 터널구간 영업소구간의 V/C가 각각 0.78, 0.75, 0.57일 때 사고율이 가장 낮은 것으로 나타났다.

  • PDF

인산형 연료전지용 SiC-SiC Whisker 전해질 매트릭스의 특성 (Characterization of SiC-SiC Whisker Matrix Retaining Electrolyte in Phosphoric Acid Fuel Cell)

  • 윤기현;이현임;이근행;김창수
    • 한국세라믹학회지
    • /
    • 제29권8호
    • /
    • pp.587-592
    • /
    • 1992
  • Sheets of SiC-SiC whisker maxed matrix were prepared from the mixed slurry of SiC whisker and SiC matrix by the rolling method. With the increase of SiC whisker, the pore size, the porosity and the phosphoric acid absorbency of the matrix were increased, while the bubble pressure was decreased. The activation energy for the transfer of H+ ion was decreased with the increase of mixing ratio of SiC whisker to the SiC matrix from the measurement of hydrogen ion conductivity. The activation energy was evaluated as 0.25 eV when the mixing ratio of SiC whisker to the SiC matrix was 1 : 2 and the activation energy was 0.16 eV for the 2 : 1 matrix. It means that SiC whisker matrix contributes to attain a better microstructure for the diffusion of hydrogen ion. From the measurement of single cell performance of matrix with various mixing ratio, it is concluded that if SiC-SiC whisker maxed matrix has a sufficient bubble pressure to prevent the crossover of H2 gas, the current density of a fuel cell is increased with the increase of acid absorbency of the matrix. Current density was improved from 140 mA/$\textrm{cm}^2$ for 0.25 mm thickness of matrix to 170 mA/$\textrm{cm}^2$ for the 0.20 mm one at 700 mV.

  • PDF

Chest compression quality, exercise intensity, and energy expenditure during cardiopulmonary resuscitation using compression-to-ventilation ratios of 15:1 or 30:2 or chest compression only: a randomized, crossover manikin study

  • Kwak, Se-Jung;Kim, Young-Min;Baek, Hee Jin;Kim, Se Hong;Yim, Hyeon Woo
    • Clinical and Experimental Emergency Medicine
    • /
    • 제3권3호
    • /
    • pp.148-157
    • /
    • 2016
  • Objective Our aim was to compare the compression quality, exercise intensity, and energy expenditure in 5-minute single-rescuer cardiopulmonary resuscitation (CPR) using 15:1 or 30:2 compression-to-ventilation (C:V) ratios or chest compression only (CCO). Methods This was a randomized, crossover manikin study. Medical students were randomized to perform either type of CPR and do the others with intervals of at least 1 day. We measured compression quality, ratings of perceived exertion (RPE) score, heart rate, maximal oxygen uptake, and energy expenditure during CPR. Results Forty-seven students were recruited. Mean compression rates did not differ between the 3 groups. However, the mean percentage of adequate compressions in the CCO group was significantly lower than that of the 15:1 or 30:2 group ($31.2{\pm}30.3%$ vs. $55.1{\pm}37.5%$ vs. $54.0{\pm}36.9%$, respectively; P<0.001) and the difference occurred within the first minute. The RPE score in each minute and heart rate change in the CCO group was significantly higher than those of the C:V ratio groups. There was no significant difference in maximal oxygen uptake between the 3 groups. Energy expenditure in the CCO group was relatively lower than that of the 2 C:V ratio groups. Conclusion CPR using a 15:1 C:V ratio may provide a compression quality and exercise intensity comparable to those obtained using a 30:2 C:V ratio. An earlier decrease in compression quality and increase in RPE and heart rate could be produced by CCO CPR compared with 15:1 or 30:2 C:V ratios with relatively lower oxygen uptake and energy expenditure.

선형 저밀도 폴리에틸렌과 에틸렌 비닐아세테이트의 혼합비에 따른 박막의 전기적 특성 (The Electrical Properties of Film due to the Mixture Ratio of Linear Lour Density Polyethylene and Ethylene Vinyl Acetate)

  • 이충호;박찬원
    • 한국안전학회지
    • /
    • 제14권2호
    • /
    • pp.83-89
    • /
    • 1999
  • The electrical properties due to mixture ratio of linear low density polyethylene(LLDPE) and ethylene vinyl acetate(EVA) films are studied. An experimental specimen is selected as LLDPE/EVA of thickness 200${\mu}{\textrm}{m}$ produced by mixture ratio of 50 : 50, 60 : 40, 70 : 30 and 80 : 2 wt%. In temperature range from $25^{\circ}C$ to 12$0^{\circ}C$, the measurement of volume resistivity using a highmegohm meter is performed within 10 minutes since each voltage of DC 100 V, 250 V, 500 V and 1000 V is applied, according to the step voltage method. From FT-IR spectrum for an analysis of physical properties, it can be confirmed that LLDPE blended with EVA shows an absence of carbonyl groups(1735 $cm^{-1}$, C=0) and ether groups(1242 $cm^{-1}$, C-O). The peak of LLDPE and EVA made of mixture ratio of 70 : 30 at 2$\theta$ =21.4$^{\circ}$ in the results of XRD is higher than the others. In the experiment for volume resistivity characteristics in order to investigate the electrical properties of specimen, it is confirmed that volume resistivity is decreased with the increase of the molecular motion and temperature.

  • PDF

The effects of vertical earthquake motion on an R/C structure

  • Bas, Selcuk;Kalkan, Ilker
    • Structural Engineering and Mechanics
    • /
    • 제59권4호
    • /
    • pp.719-737
    • /
    • 2016
  • The present study investigated the earthquake behavior of R/C structures considering the vertical earthquake motion with the help of a comparative study. For this aim, the linear time-history analyses of a high-rise R/C structure designed according to TSC-2007 requirements were conducted including and excluding the vertical earthquake motion. Earthquake records used in the analyses were selected based on the ratio of vertical peak acceleration to horizontal peak acceleration (V/H). The frequency-domain analyses of the earthquake records were also performed to compare the dominant frequency of the records with that of the structure. Based on the results obtained from the time-history analyses under the earthquake loading with (H+V) and without the vertical earthquake motion (H), the value of the overturning moment and the top-story vertical displacement were found to relatively increase when considering the vertical earthquake motion. The base shear force was also affected by this motion; however, its increase was lower compared to the overturning moment and the top-story vertical displacement. The other two parameters, the top-story lateral displacement and the top-story rotation angle, barely changed under H and H+V loading cases. Modal damping ratios and their variations in horizontal and vertical directions were also estimated using response acceleration records. No significant change in the horizontal damping ratio was observed whereas the vertical modal damping ratio noticeably increased under H+V loading. The results obtained from this study indicate that the desired structural earthquake performance cannot be provided under H+V loading due to the excessive increase in the overturning moment, and that the vertical damping ratio should be estimated considering the vertical earthquake motion.

한냉에 노출된 인체의 냉각과 총지방량 및 S/V 비율 사이의 관계 (Relationship between Total Body Fat and S/V Ratio and Body Cooling for Two Hours at $15^{\circ}C$)

  • 정관옥;남기용
    • The Korean Journal of Physiology
    • /
    • 제3권1호
    • /
    • pp.19-28
    • /
    • 1969
  • Skin temperatures on 10 sites and rectal temperature at every 10 minutes, oxygen consumption at every 20 minutes were measured on 18 male subjects (ages between 14 and 47 years) after exposure to cold air at $15^{\circ}C$ for two hours in a climatic room. Total body fat measured by means of a skinfold method and ratio of body surface area (S) to body volume (V), S/V, were utilized as basis of observations. Surface area was calculated after DuBois equation and body volume was calculated by our original formula. In influencing on the heat loss from the body core to the cold environment, % fat showed inverse relations, whereas, S/V ratio showed direct relations. Thus these two factors acted antagonistically on the body heat loss. Local skin temperatures showed negative correlations with skinfold thickness on the same site, nemaly, on chest, r=-.567; on back, r=-.507; and on upper arm, r=-.353. The other 7 skin sites showed low correlations with % fat. Minimum mean weighted skin temperature (MWST) showed a negative correlation (r=-.443) with % fat, and showed no correlation with S/V ratio. Oxygen consumption in the cold air at $15^{\circ}C$ increased from the first measurement at 20 minutes after exposure and maintained the same increasing trend up to 120 minutes. ${\Delta}T_R$ was greater in tile lean subjects who showed a greater % change in oxygen consumption. The antagonistic actions of % fat and S/V ratio on the heat loss were manifested by observations as follows: minimum rectal temperature was higher In fat subjects (r=.600) and lower in subjects with a greater S/V ratio (=-.582), ${\Delta}T_R$ was smaller in fat subjects (r=-.738) and greater in subjects with a greater S/V ratio (r=.618). Temperature difference between body core and skin surface (minimum rectal temperature minus minimum MWST) showed a positive correlation with % fat (r=.600) and a negative correlation with S/V ratio (r=-.881). Decrease in the mean body temperature and heat debt, respectively, showed negative correlations with % fat and positive correlations with S/V ratio.

  • PDF