• Title/Summary/Keyword: V$_{}$ 50/

Search Result 5,470, Processing Time 0.038 seconds

A Study on the Carbothermic Reduction and Refining of V, Ta and B Oxides by Ar/Ar-H2 Plasma (Ar/Ar-H2 플라즈마에 의한 V, Ta, B 산화물의 탄소용융환원 및 정련)

  • Chung, Yong-Sug;Park, Byung-Sam;Hong, Jin-Seok;Bae, Jung-Chan;Kim, Moon-Chul;Baik, Hong-Koo
    • Journal of Hydrogen and New Energy
    • /
    • v.7 no.1
    • /
    • pp.81-92
    • /
    • 1996
  • The Ar/Ar-$H_2$ plasma method was applied to reduce oxides and refine metals of V, Ta and B. In addition, the high temperature chemical reaction in Ar plasma and of the refining reaction in the Ar-(20%)$H_2$ plasma were analyzed. The crude V of 96wt% purity was obtained at the ratio of $C/V_{2}O_{5}=4.50$ by the Ar plasma reduction grade and the maximum reduction was obtained at $C/V_{2}O_{5}=4.50$ due to the $O_{2}$ loss from the thermal decomposition of vanadium oxide. In the Ar-(20%)$H_2$ plasma refining, the metallic V of 99.2wt% was produced at the ratio of $C/V_{2}O_{5}=4.40$. It was considered that a main refining reaction resulted from the chemical reaction between the residual carbon and residual oxygen. The metallic Ta of 99.8wt% was obtained at the ratio of $C/Ta_{2}O_{5}=5.10$ in a Ar plasma reduction and the Oz loss from the thermal decomposition of tantalum pentoxide did not take place. The deoxidation reaction was more significant than the decarburization reaction in the Ar-(20%)$H_2$ plasma refining and the metallic Ta of 99.9wt% was produced within the range of $C/Ta_{2}O_{5}$ ratio of 4.50 to 5.10. The Vickers hardness of Ta in the above mentioned range was about 220Hv due to the decrease in a residual oxygen by the deoxidation reaction. On the other hand, C is no suitable agent for the reduction of $B_{2}O_{3}$ by the Ar and Ar-$H_2$ plasma. But Fe-B-Si alloy was produced with the reduction of $B_{2}O_{3}$ in the melt when Fe, C, $B_{2}O_{3}$, and ferroboron mixtures were melted by the high frequency induction melting.

  • PDF

A Study on perforation behavior of Aluminum 5052-H34 alloy by high velocity impact (고속충격에 의한 A1 5052-H34 합금의 관통거동에 관한 연구)

  • Sohn, Se-Won;Lee, Doo-Sung;Hong, Sung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.174-179
    • /
    • 2001
  • In order to investigate the fracture behaviors(perforation modes) and resistance to perforation during ballistic impact of aluminum alloy plate, ballistic tests were conducted. Depth of penetration experiments with 5.56mm-diameter ball projectile launched into 25mm-thickness Al 5052-H34 targets were conducted. A powder gun launched the 3.55g projectiles at striking velocities between 0.6 and 1.0 km/s. radiography of the damaged targets showed different penetration modes as striking velocities increased. Resistance to perforation is determined by the protection ballistic limit($V_{50}$), a statistical velocity with 50% probability for complete perforation. Fracture behaviors and ballistic tolerance, described by perforation modes, are respectfully observed at and above ballistic limit velocities, as a result of $V_{50}$ test and Projectile Through Plates (PTP) test methods. PTP tests were conducted with $0^{\circ}$ obliquity at room temperature using 5.56mm ball projectile. $V_{50}$ tests with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete perforation during PTP tests. The effect of various impact velocity are studied with depth of penetration.

  • PDF

A Study on the high velocity impact behavior of titanium alloy by PVD method (PVD처리한 티타늄 합금의 고속충격 거동에 관한 연구)

  • Sohn, Se-Won;Lee, Doo-Sung;Hong, Sung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.567-572
    • /
    • 2001
  • In order to investigate the fracture behaviors(penetration modes) and resistance to penetration during ballistic impact of Titanium alloy laminates and nitrified Titanium alloy laminates which were treated by PVD(Physical Vapor Deposition) method, ballistic tests were conducted. Evaporation, sputtering, and ion plating are three kinds of PVD method. In this research, Ion plating was used to achieve higher surface hardness and surface hardness test were conducted using a Micro vicker's hardness tester. Resistance to penetration is determined by the protection ballistic limit($V_{50}$), a statistical velocity with 50% probability for complete penetration. Fracture behaviors and ballistic tolerance, described by penetration modes, are respectfully observed at and above ballistic limit velocities, as a result of $V_{50}$ test and Projectile Through Plates (PTP) test methods. PTP tests were conducted with $0^{\circ}$ obliquity at room temperature using 5.56mm ball projectile. $V_{50}$ test with $0^{\circ}$ obliquity at room temperature were conducted with projectiles that were able to achieve near or complete penetration during PTP tests. Surface hardness, resistance to penetration, and penetration modes of Titanium alloy laminates are compared to those of nitrified Titanium alloy laminates.

  • PDF

A Study on Development of High Voltage Mica Capacitors (고전압 마이카 커패시터 개발에 관한 연구)

  • Yun, Eui-Jung;Choi, Cheal-Soon;Kim, Jae-Wook;Lee, Dong-Hyuk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1229-1234
    • /
    • 2008
  • In this work, ultra high-voltage (17 - 50 kV AC), reliable 80 pF mica capacitors for partial discharge system application were investigated. Mica was used as the dielectric of the capacitors. Using the conservative design rule, over 3 individual $50\;{\mu}m$ thick mica sheets with a size of 30mm{\times}35mm were used with lead foils to form a parallel capacitor element and 20 mica sheets were interleaved with lead foils to form a series stack of parallel capacitor element to meet the requirements of the capacitors. The dimensions of the fabricated 80 pF capacitors for 17 kV AC and 50 kV AC were $90\;mm{\times}90\;mm$ and $95\;mm{\times}180\;mm$, respectively. The high-frequency characteristics of the capacitance (C) and dissipation factor (D) of the developed capacitors were measured using a capacitance meter. The developed capacitors exhibited C of 79.5 - 87.5 pF, had D of 0.001% over the frequency ranges of 150 kHz to 50 MHz, had a self-resonant frequency of 65 MHz, and showed results comparable to those measured for the capacitors prepared recently by $Adwel^{Tm}$. The developed capacitors also showed excellent characteristics for thermal shock test and temperature cycling test.

High Efficiency Output Filter Design and Application for High Accuracy and High Stable Switching Type MPS (고정밀, 고안정 스위칭 전자석 전원장치를 위한 고효율 출력필터의 설계 및 응용)

  • Kim, S.C.;Ha, K.M.;Huang, J.Y.;Choi, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.998-999
    • /
    • 2006
  • 포항가속기 연구소의 선형가속기에는 22개의 솔레노이드 전자석, 16개의 사극전자석 그리고 전자빔의 궤도 조절을 위한 16개의 2극 전자석이 있다. 선형가속기의 빔을 저장링으로 공급해주는 빔 전송선에는 22개의 사극전자석과 13개의 빔 궤도 조절용 이극 전자석이 있다. 전자빔의 정밀 제어를 위하여 전자석의 전원장치는 출력전류 분해능은 16bit 이상이고 출력전류의 안정도는 최대출력에 대하여 ${\pm}50ppm$ 이하의 고정밀 고안정도가 요구된다. 이를 위하여 풀-브릿지 4상한 DC/DC 컨버터를 이용한 전자석전원장치를 개발 하였다. 전원장치의 입력전압 직류 40V이고 출력전류는 단방향 전원장치는 최대 50A/50V 이고 양방향 전원장치는 ${\pm}20A/20V$이다. 스위칭 주파수는 50 kHz이다. 전원장치의 출력부에 필터가 없으면 출력전류에는 스윗칭과 관련된 주파수 성분이 포함 되고 전자빔은 이들 주파수 성분에 대하여 영향을 받게 된다. 이러한 이유로 출력 필터의 cut-off 주파수는 5 kHz 이하가 되어야 한다. 본 논문에서는 고정밀 고안정 스윗칭 전자석전원장치를 위한 출력필터의 설계, 제작 그리고 이를 적용한 전자석전원장치에 대하여 논의 하고자 한다.

  • PDF

Development of a device to improve the precision of water surface identification for MeV electron beam dosimetry

  • F. Okky Agassy;Jong In Park;In Jung Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1431-1440
    • /
    • 2024
  • The study aimed to develop a laser-based distance meter (LDM) to improve water surface identification for clinical MeV electron beam dosimetry, as inaccurate water surface determination can lead to imprecise positioning of ionization chambers (ICs). The LDM consisted of a laser ranging sensor, a signal processing microcontroller, and a tablet PC for data acquisition. I50 (the water depth at which ionization current drops to 50 % of its maximum) measurements of electron beams were performed using six different types of ICs and compared to other water surface identification methods. The LDM demonstrated reproducible I50 measurements with a level of 0.01 cm for all six ICs. The uncertainty of water depth was evaluated at 0.008 cm with the LDM. The LDM also exposed discrepancies between I50 measurements using different ICs, which was partially reduced by applying an optimum shift of IC's point of measurement (POM) or effective point of measurement (EPOM). However, residual discrepancies due to the energy dependency of the cylindrical chamber's EPOM caused remained. The LDM offers straightforward and efficient means for precision water surface identification, minimizing reliance on individual operator skills.

Performance of Seedling Grafts of Tomato as Influenced by Root Medium Formulations and Leaching Fractions in Irrigation or Fertigation (혼합상토 조성과 관수 또는 관비시 배액률이 토마토 접목묘 생장에 미치는 영향)

  • Choi, Jong Myung
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.235-243
    • /
    • 2014
  • This research was conducted to investigate the influence of leaching fractions (LF) in each irrigation or fertigation on plant growth and changes in chemical properties of root media during the production of seedling grafts of tomato. Two root media containing Sphagnum peat moss plus vermiculite (5:5, v/v, PV) and coir dust plus vermiculite (5:5, v/v, CV) were formulated and pre-planting fertilizers were incorporated during formulation. Then, each medium was packed into 50 cell (volume 33 cc) and 105 cell (volume 18 cc) trays and the rootstock (cv. J3B Strong) and scion (cv. Sunmyung) were grown, respectively. The seedlings were grafted at 31 days after sowing and then the cut seedling grafts (Sunmyung scion/J3B Strong rootstock) were planted into 50 cell plug trays containing each of the two root media. After induction of the graft union and new adventitious roots for 7 days, the seedling grafts were fed with fertilizer solution once a week containing 4 different N concentrations (0, 50, 100, $200mg{\cdot}L^{-1}$). When determined after 31 days from seed sowing, the highest fresh weights of the root stock seedlings were obtained with 0.75 LF in PV (8.96g/seedling) and CV (7.11g/seedling) mixes. The EC of the both mixes were 0.93 and $1.09dS{\cdot}m^{-1}$, respectively. The fresh weights of the scion seedlings 31 days after seed sowing were 4.29g with 0.50 LF in the PV and 3.13g with 0.50 LF in the CV. The root medium ECs of the two treatments were 0.76 and $1.34dS{\cdot}m^{-1}$, respectively. Fresh weights of the seedling grafts grown for 31 days were greatly influenced by post-planting fertilizer concentrations. The heavier plants were obtained in $100mg{\cdot}L^{-1}$ N treatment than any other treatments in same mixes. The substrate ECs in these two treatments were 0.98 and $1.93dS{\cdot}m^{-1}$, respectively, indicating that the desirable range of soluble salts in soil extracts is higher in the CV mix than the PV mix. Results of this study suggest that optimum EC range is different in each medium and LF need to be adjusted differently for each root medium to produce high quality seedling grafts of tomato.

Optimization of Total Arc Degree for Stereotactic Radiotherapy by Using Integral Biologically Effective Dose and Irradiated Volume (정위방사선치료 시 적분 생물학적 유효선량 및 방사선조사용적을 이용한 Total Arc Degree의 최적화)

  • Lim Do Hoon;Lee Myung Za;Chun Ha Chung;Kim Dae Yong
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.199-204
    • /
    • 2001
  • Purpoe : To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. Methods and Materials : With Xknife-3 planning system & 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, $100^{\circ},\;200^{\circ},\;300^{\circ},\;400^{\circ}C,\;500^{\circ},\;600^{\circ}$ or total arc degrees, and $30^{\circ}\;or\;45^{\circ}$ or arc intervals were used. After the completion of planning, the plans were compared each other using $V_{50}$ (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. Results : At $30^{\circ}$ of arc interval, the values of $V_{50}$ had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 arc interval, up to $400^{\circ}$ of total arc degree, the values of $ V_{50}$ decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. At $30^{\circ}$ of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At $45^{\circ}$ arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with n and n mm or collimator diameters, up to $400^{\circ}$ or total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. Conclusion : In the stereotactic radiotherapy planning for brain lesions, planning with $400^{\circ}$ of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of $500^{\circ}\;and\;600^{\circ}$ of total arc degrees make the increase of$V_{50}$ and integral biologically effective dose. Therefore stereotactic radiotherapy planning using $400^{\circ}$ of total arc degree can increase the therapeutic ratio and produce the effective outcome in the management of personal and mechanical sources in radiotherapy department.

  • PDF

The Basic Study on 800kV GIS Development (800kV GIS 개발을 위한 기본연구)

  • Kim, J.B.;Yang, D.I.;Song, W.P.;Lee, C.H.;Noh, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1341-1343
    • /
    • 1995
  • The maximum transmission voltage in our country is going to change 345kV into 765kV owing to the increase of Electrical Power Demand and power System Stability. Our company is developing 800kV GIS and 765kV Transformer which are main equipments in 765kV substation. This paper describs the specification on 800kV GIS which we prepared for 800kV 8,000A 50kA GIS development. This specification is supported by Public Standards and Data. And, we are designing the 800kV GIS on this specification and drawing up the 800kV GIS layout for type test.

  • PDF

Wear Mechanism and Machinability of PCD Tool in Turning Tungsten Carbides (초경합금재의 선반절삭에 있어서 PCD공구의 마멸 기구와 절삭성)

  • Heo, Sung Jung
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.1
    • /
    • pp.85-91
    • /
    • 2013
  • The machinability of wear-resistible tungsten carbides and the tool wear behavior in machining of V30 and V50 tungsten carbides using PCD (Poly Crystalline Diamond) cutting tool was investigated to understand machining characteristics. This material is one of the difficult-to-cut materials in present, but their usage has been already broadened to every commercial applications such as mining tools, and impact resistant tools etc. Summary of the results are as follows. (1) Tool wear progression of PCD tools in turning of wear-resistible tungsten carbides were observed specially fast in primary cutting distance within 10m. (2) Three components of cutting resistance in this research were different in balance from the ordinary cutting such as that cutting of steel or cast iron. Those were expressed large value by order of thrust force, principal force, feed force. (3) If presume from viewpoint of high efficient cutting within this research, a proper cutting speed was 15m/min and a proper feed rate was 0.1mm/rev. In this case, it was found that the tool life of PCD tool was cutting distance until 230m approximately. (4) In cutting of wear-resistible tungsten carbides such as V30 and V50, it was recognized that the tool wear rate of V30 was very fast as compared with V50. (5) When the depth of cut was 0.1mm, there was no influence of the feed rate on the feed force. And the feed force tended to decrease as the cutting distance was long, because the tool was worn and the tool edge retreated. (6) It was observed that the tungsten carbides were adhered to the flank.