• Title/Summary/Keyword: Utility-reduction

Search Result 196, Processing Time 0.029 seconds

A Study on the Removal of Slagging and Fouling for an Optimal Operation of Power Utility Boilers (보일러 최적운전을 위한 슬래깅 및 파울링 제거 연구)

  • Yook, Sim-Kyun;Kim, Sung-Ho;Lee, Byeong-Eun;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.12
    • /
    • pp.1772-1780
    • /
    • 2003
  • An optimal soot blowing system has been developed for an optimal operation of power utility boilers by both minimization of the use of steam and the number of soot blowers worked during soot blowing. Traditionally, the soot blowing system has been operated manually by operators. However, it causes the reduction of power and thermal performance degradation because all soot blowers installed in the plant should be worked simultaneously even there are lots of tubes those are not contaminated by slagging or fouling. Heat transfer area is divided into four groups, furnace, convection area including superheater, reheater and economizer, and air preheater in the present study. The condition of cleanness of the tubes is calculated by several parameters obtained by sensors. Then, a part of soot blowers works automatically where boiler tubes are contaminated. This system has been applied in a practical power plant. Therefore, comparison has been done between this system and manual operation and the results are discussed.

A New 12-Pulse Diode Rectifier System With Low kVA Components For Clean Power Utility Interface

  • ;Prasad N.Enjeti
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.5
    • /
    • pp.423-432
    • /
    • 1999
  • This paper proposes a 12­pulse diode rectifier system with low kVA components suitable for powering switch mode power supplies or ac/dc converter applications. The proposed 12-pulse system employs a polyphase transformer, a zero sequence blocking transformer (ZSBT) in the dc link, and an interphase transformer. Results produce near equal leakage inductance in series with each diode rectifier bridge ensuring equal current sharing and performance improvements, The utility input currents and the voltage across the ZSBT are analyzed the kVA rating of each component in the proposed system is computed. The 5th , 7th , 17th and 19th harmonics are eliminated in the input line currents resulting in clean input power. The dc link voltage magnitude generated by the proposed rectifier system is nearly identical to a conventional to a conventional 6-pulse system. The proposed system is suitable to retrofit applications as well as in new PWM drive systems. Simulation and experimental results from a 208V , 10kVA system are shown.

  • PDF

Economic Feasibility Study for Peak Load Control (최대부하제어(最大負荷制御)의 경제적(經濟的) 타당성(妥當性) 검토(檢討))

  • Yu, Sung-Chul;Yoon, Kap-Koo;Cho, Soon-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.19-22
    • /
    • 1993
  • Demand side management (DSM) is the planning and implementation of those utility designed to influence customer use of electricity in ways that will produce desired changes in the utility's load shape. It is conspicuous that the peak load control of DSM is efficiently adopted. In this paper, the package type air conditioner(A/C) mounted radio controlled switch. During the summer of 1990 KEPCO conducted tests in Seoul areas to determine the economic feasibility of interrupting A/C units for short periods of time during peak load periods. These tests were performed between July 30 and September 20 and were limited to the hours of between 1 and 6 p.m. These tests indicated that each A/C contributes approximately 4.5kW to the system peak and can be switched off 10 minutes out of each 1/2 hour without causing the customer any discomfort. Switching each A/C off for 10 minutes out of each 1/2 hour results in a peak load demand reduction of one kW per unit.

  • PDF

Utility Interactive PV Systems with Power Shaping Function for Increasing Peak Power Cut Effect

  • Choe, Gyu-Ha;Kim, Hong-Sung;Heo, Hye-Seong;Jeong, Byong-Hwan;Choi, Young-Ho;Kim, Jae-Chul
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.371-380
    • /
    • 2008
  • This paper describes the Utility Interactive PV (UIPV) system which can improve the peak-cut effect by adding an energy storage device of batteries to the power converter. The proposed system has three possible operation modes depending on relative condition of PV output, which can have the power shaping function covering the peak power for 3 hours. A new power circuit and an application algorithm have been applied to the UIPV system which is based on working PV system during a 3-hour peak time. The energy relationship by the proposed system is analyzed theoretically and experimentally. The proposed system is evaluated at the viewpoint of cost and total spacing, which enables the proposed UIPV system to have the reduction of the peak power demand and hence to improve the power capacity of peak cut.

Utility Interactive Solar Power Conditioner with Zero Voltage Soft Switching High frequency Sinewave Modulated Inverter Link

  • Terai H.;Sumiyoshi S.;Kitaizumi T.;Omori H.;Ogura K.;Chandhaket S.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.668-672
    • /
    • 2001
  • The utility interactive sinewave modulated inverter for the solar photovoltaic (PV) power conversion and conditioning with a new high frequency pulse modulated link is presented for domestic residential applications. As compared with the conventional full-bridge hard switching PWM inverter with a high frequency AC link, the simplest single-ended quasi-resonant soft switching sinewave modulated inverter with a duty cycle pulse control is implemented, resulting in size and weight reduction and low-cost. This paper presents a prototype circuit of the single-ended zero voltage soft switching sinewave inverter for solar power conditioner and its operating principle. In addition, this paper proposes a control system to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed from an experimental point of view. A newly developed interactive sinewave power processor which has $92.5\%$ efficiencty at 4kW output is demonstrated. It is designed 540mm-300mm-125mm in size, and 20kg in weight.

  • PDF

Evaluation of Health-Related Quality of Life among Patients with Cervical Cancer in Indonesia

  • Endarti, Dwi;Riewpaiboon, Arthorn;Thavorncharoensap, Montarat;Praditsitthikorn, Naiyana;Hutubessy, Raymond;Kristina, Susi Ari
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3345-3350
    • /
    • 2015
  • Background: Evaluation of health-related quality of life (HRQOL) in cervical cancer patients is important in order to design the interventions for improving patient outcomes. Reports of HRQOL among cervical cancer patients in Indonesia are limited. Moreover, measurement using EQ-5D-3L is to our best knowledge has hitherto not been performed. This study aimed to examine the HRQOL of cervical cancer patients in Indonesia using EQ-5D-3L. Materials and Methods: A cross-sectional study was conducted by interviewing cervical cancer patients using the EQ-5D-3L questionnaire. Percentages of patients who reported having problems in each dimension of EQ-5D as well as EQ-5D index score (utility) were calculated. Results: Our findings indicated that the most frequent reported problems were pain/discomfort (67.8%) followed by anxiety/depression (57.5%). The mean of EQ-5D VAS was 75.8 (SD=17.0). The mean (SD) utility scores were 0.85 (0.19), 0.76 (0.20), 0.71 (0.21), and 0.77 (0.13) for cervical cancer patients in stage I, II, III, and IV, respectively. Conclusions: Cervical cancer significantly affects patient HRQOL. Efforts should be made to improve the quality of life of cervical cancer patients especially in terms of pain /discomfort and anxiety/depression reduction.

Decision-Making of Determining the Start Time of Charging / Discharging of Electrical Vehicle Based on Prospect Theory

  • Liu, Lian;Lyu, Xiang;Jiang, Chuanwen;Xie, Da
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.803-811
    • /
    • 2014
  • The moment when Electrical Vehicle (EV) starts charging or discharging is one of the most important parameters in estimating the impact of EV load on the grid. In this paper, a decision-making problem of determining the start time of charging and discharging during allowed period is proposed and studied under the uncertainty of real-time price. Prospect theory is utilized in the decision-making problem of this paper for it describes a kind of decision making behaviors under uncertainty. The case study uses the parameters of Springo SGM7001EV and adopts the historical realtime locational marginal pricing (LMP) data of PJM market for scenario reduction. Prospect values are calculated for every possible start time in the allowed charging or discharging period. By comparing the calculated prospect values, the optimal decisions are obtained accordingly and the results are compared with those based on Expected Utility Theory. Results show that with different initial State-of-Charge ($SoC_0$) and different reference points, the optimal start time of charging can be the one between 12 a.m. to 3 a.m. and optimal discharging starts at 2 p.m. or 3p.m. Moreover, the decision results of Prospect Theory may differ from that of the Expected Utility Theory with the reference points changing.

Non-inferiority study of the efficacy of two hyaluronic acid products in post-extraction sockets of impacted third molars

  • Yang, Hyunwoo;Kim, Junghun;Kim, Jihong;Kim, Dongwook;Kim, Hyung Jun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.40.1-40.5
    • /
    • 2020
  • Background: Hyaluronic acid (HA) is well known to exert an anti-inflammatory effect during oral wound healing and is commonly applied after tooth extraction. However, no double-blind randomized controlled study comparing two hyaluronate mouthwash products has been conducted so far. The aim of this study was to comparatively analyze the efficacy of Mucobarrier® and Aloclair® in terms of clinical symptoms. Results: A total of 112 patients were randomly assigned to assess the degree of discomfort, pain reduction, redness, burning sensation, and swelling between two groups on the day of surgery and 7 days later in a double blind test, with a total 56 Aloclair patients and 56 Mucobarrier patients. There was no statistically significant difference in the overall discomfort, degree of pain reduction, redness, burning sensation, and swelling between the Mucobarrier and Aloclair groups. Conclusion: The local application of hyaluronic acid mouth wash after wisdom tooth extraction is beneficial in reducing overall discomfort and pain reduction, and the clinical utility of Mucobarrier® is no different from Aloclair®. Trial registration: Institutional Review Board of Yonsei University College of Dentistry, 2-2018-0036. Registered 10 September 2018-prospectively registered, https://eirb.yuhs.ac/

A Methodology for Evaluating the Effects of Transportation Policies Related to Greenhouse Gas Reduction (교통온실가스 감축정책의 효과분석 방법론 연구)

  • LEE, Kyu Jin;YI, Yongju;CHOI, Keechoo
    • Journal of Korean Society of Transportation
    • /
    • v.36 no.1
    • /
    • pp.1-12
    • /
    • 2018
  • The purpose of this study is to establish a methodology for evaluating quantitative effects of transportation GHG (greenhouse gas) reduction-related policies that were implemented based on the reduction goals of transportation GHG and effective implementation plans. This study uses a modal utility function and demand estimation models as well as a GHG emission basic unit estimation model by each transportation mode based on actual traffic and emission data. The results showed that the effects of GHG reduction policies such as electric vary from region to region, and from vehicle to vehicle. It is also confirmed that an eco-drive promotion policy, one of the lowest budget policies, is expected to contribute to high reduction in GHG. In addition, not only automobile emission improvement policies but also the promotion policies of public transportation are expected to highly reduce GHG as confirmed quantitatively in this study. The results of this study are expected to be useful for national and local governments' evaluation of GHG reduction policies to cope with the post 2020.

Development of the Performance Measurement Model of Electronic Medical Record System - Focused on Balanced Score Card - (균형성과표를 활용한 전자의무기록시스템의 성과측정 모형개발)

  • Lee, Kyung Hee;Kim, Young Hoon;Boo, Yoo Kyung
    • Korea Journal of Hospital Management
    • /
    • v.21 no.4
    • /
    • pp.1-12
    • /
    • 2016
  • The purpose of this study are suggest to performance measurement model of Electronic Medical Record(EMR) and Key Performance Index(KPI). For data collection, 665 questionnaires were distributed to medical record administrators and insurance reviewers at 31 hospitals, and 580 questionnaires were collected(collection rate: 87.2%). Regarding methodology, Critical Success Factor(CSF) and index of the information system were derived based on previous studies, and these were set as performance measurement factors of EMR system. The performance measurement factors were constructed by perspective using BSC, and analysis on causal relationship between factors was conducted. A model of causal relationship was established, and performance measurement model of EMR system was proposed through model validation. Analysis on causal relationship between performance management factors revealed that utility cognition of the learning & growth perspective factor had causal relationship with job efficiency(${\beta}=0.20$) and decision support(${\beta}=0.66$) of the internal process perspective factors, and security had causal relationship with system satisfaction(${\beta}=0.31$) of the customer perspective factor. System quality had causal relationship with job efficiency(${\beta}=0.66$) and decision support(${\beta}=0.76$) of the internal process perspective factors, all of which were statistically significant(P<0.01). Job efficiency of the internal process perspective had causal relationship with system satisfaction(${\beta}=0.43$), and decision support had causal relationship with decision support satisfaction(${\beta}=0.91$) and job satisfaction (${\beta}=0.74$), all of which were statistically significant(P<0.01). System satisfaction of the customer perspective had causal relationship with job satisfaction(${\beta}=0.12$), job satisfaction had causal relationship with cost reduction(${\beta}=0.53$) of the financial perspective, and decision support satisfaction had causal relationship with productivity improvement(${\beta}=0.40$)of the financial perspective(P<0.01). Also, cost reduction of the financial perspective had causal relationship with productivity improvement(${\beta}=0.37$), all which were statistically significant(P<0.05). Suitability index verification of the performance measurement model whose causal relationship was found to be statistically significant revealed that $X^2/df=2.875$, RMR=0.036, GFI=0.831, AGFI=0.810, CFI=0.887, NFI=0.838, IFI=0.888, RMSEA=0.057, PNFI=0.781, and PCFI=0.827, all of which were in suitable levels. In conclusion, the performance measurement indices of EMR system include utility cognition, security, and system quality of the learning & growth perspective, decision support and job efficiency of the internal process perspective, system satisfaction, decision support satisfaction, and job satisfaction of the customer perspective, and productivity improvement and cost reduction of the financial perspective. In this study, it is expected that the performance measurement indices and model of EMR system which are suggested by the author, will be a measurement tool available for system performance measurement of EMR system in medical institutions.