• Title/Summary/Keyword: Utility Value of Floor

Search Result 5, Processing Time 0.025 seconds

An analysis of Change on the Apartment Unit Plans Based on the Interior Spaces for Women (여성 공간을 중심으로 본 수도권 아파트의 공간구조 변화)

  • Choi, Byung-Sook;Park, Jung-A
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.354-359
    • /
    • 2008
  • The purpose of this study is to find out the changes on the metropolitan apartment unit plans based on the interior spaces for women such as master bedroom, bathroom and attached spaces to the master bedroom, living room, diningroom, kitchen, utility room, and balcony. This study used the content analysis method, space syntax. Contents were the floor plans with 3 rooms type and limited to about $105m^2$ among drawings of an apartment encyclopedia. Above all, 174 unit plans were analyzed until now. Specifically, using $S^3$-Convex program, the integration and control value periodically of the interior spaces for women(master bedroom, bathroom and attached spaces to the master bedroom, living room, diningroom, kitchen, utility room) is understood. Second, using SPSS package 16.0, relative size of the interior spaces for women on the unit floor plan is understood periodically. Finally, the changes on the apartment unit plans based on a woman' aspect after 1980's is reanalyzed.

  • PDF

Performance Test and Flue Gas Characteristics of a 350 kW Wood Pellet Boiler (350 kW(300,000 kcal/h)급 우드 펠렛 보일러 운전 특성 및 성능 평가)

  • Kim, Jong-Jin;Kang, Sae-Byul
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.167-171
    • /
    • 2009
  • We conducted performance test of a 350 kW class wood pellet boiler installed at a dormitory whose total area is $1,354\;m^2$. The maximum heating capacity of the boiler is 350 kW(300,000 kcal/kg). The wood pellet boiler consists of 3 parts; boiler, hot water storage tank and wood pellet storage tank. In testing the boiler, we shut off hot water utility supply and open up floor heating water system in order to measure exact value of the heating output of the wood pellet boiler. To determine the efficiency and heating output of the wood pellet boiler, we measured mass flow rate of wood pellet, the lower heating value(LHV) of the wood pellet, mass flow rate and temperature of water for floor heating and so on. We measured the mass flow rate of fuel, wood pellet with respect to rotational speed of auger, wood pellet feeding screw. We also measured the flue gas concentration of the wood pellet boiler by using a gas analyser. The result shows that the efficiency of the wood pellet boiler is 80.6% based on lower heating value at 124 kW of heating output. At this condition, O2 concentration of the flue gas is 6.0%, CO and NOx concentrations are 85 and 102 ppm.

  • PDF

Estimation of Dynamic Load of the Utility in Building by TPA Method (TPA 기법을 이용한 건물 내 설비 동하중 산정)

  • Jeong, Min-Ki;Lee, Seong-Soo;Kim, Yong-Ku;Ahn, Sang-Kyung;Lee, Sang-Yeop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.8
    • /
    • pp.773-780
    • /
    • 2009
  • The facility equipments generate dynamic force on building floor and the force can be measured with force transducer. However, this method depends on the measuring capacity or range of sensor, or mounts installation condition of equipments. Because of this restricting condition on force measuring system, this paper suggests a indirect method, the TPA(transfer path analysis) method, that produces a closely approximate dynamic force of equipments. This method calculates the dynamic force by using transfer response function. Firstly, the calculated dynamic force of impact load and continuous load was respectively compared with the sensor-measured value to examine the accuracy of TPA method. After that, the dynamic force and response induced by large facility equipments - a cooling tower, AHU and a large ventilator - were calculated by TPA method and the validity of these value were examined.

GDP Linked Bonds and Currency Risk Premiums (GDP 연계채권과 환리스크 프리미엄)

  • Sohn, Kyoung-woo
    • Asia-Pacific Journal of Business
    • /
    • v.12 no.3
    • /
    • pp.379-396
    • /
    • 2021
  • Purpose - The purpose of this paper is to study the rational payoff from the standpoint of foreign investors and the government when the government issues GDP-linked bonds to foreign investors. Design/methodology/approach - In this paper, the prices of 12 types of GDP-linked bond structures, which are classified according to the calculation cycle of the rate of change of linked GDP, the currency issued, and whether options are embedded, were evaluated. The Fama-French 3-factor model and the GMM-SDF model are used in the asset pricing model, and domestic and overseas investors used different basis assets. Findings - The KRW premium for US investors is estimated to be 43bp on a quarterly basis and 30bp on an annual basis, respectively, meaning that when the government issues bonds in KRW, the interest rate paid to US investors will be reduced by 30bp to 160bp (annually converted). Using the Fama-French 3 factor model, the KRW premium is the risk premium for the US market beta, meaning that if US investors do not intend to invest in US market beta, it is advantageous to receive an additional interest rate by investing in USD-denominated GDP-linked bonds. Korea's GDP- linked bond give US investors diversified investment utility, so they are willing to incorporate Korean GDP-linked bonds even if -150bp of interest is deducted from the structure issued to Korean investors. And as a result of estimating the value of the option through the GDP-linked bond with options that provides a floor for guaranteeing the principal, the value of the option linked to the annual GDP issued in dollars was the lowest. Research implications or Originality - Issuing dollar-denominated GDP-linked bonds linked to annual GDP with the option of guaranteeing the principal by the government is a way to increase investment opportunities for US investors and achieve financial stability of the government.

Resident Preference Trends and Perceptions Regarding Royal Floors in High-rise Housing - Questionnaire Survey from Residents and Realtors of One through Four of the Jamshil Redeveloped Apartment Complexes - (아파트 로열층에 대한 선호도 변화 및 인식 특성에 대한 연구 - 서울 잠실재건축단지 거주자 및 부동산중개업자 설문조사를 중심으로 -)

  • Choi, Jung-Min
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.6
    • /
    • pp.161-172
    • /
    • 2011
  • Although the term royal floors is broadly used in high-rise housing, it is hard to find any clear scholarly definition of this term or any in-depth study exploring people's perceptions of it. This study reviewed ongoing discussions about concepts and definitions regarding royal floors, collected opinions from high-rise housing residents and realtors about the term, and compared the opinions of these two groups. First, the statistically analyzed results verified five main factors affecting people's perceptions of royal floors: locational characteristics (i.e., daylight, view, orientation), 2) price characteristics (i.e., premium, price increase level, number of houses on urgent sale), 3) best location of apartment building (i.e., location within a neighborhood, unit size), 4) architectural characteristics of apartment complex (i.e., size of complex, housing type, size options of units), and 5) personal characteristics of respondents (i.e., personal concepts of the meaning of housing, lifestyles). Results from the analysis showed that realtors perceived strong relationships between royal floors and 1) locational and 2) price characteristic factors, while residents perceived strong relationships between royal floors and personal preference as well as three factors from the five identified above: 1) locational, 2) price, and 4) architectural characteristics. Third, in defining royal floors in a building, the past rule of 1/4 is no longer effective. Instead, the rule of 1/n has become more prevalent (i.e., 1/6 to 1/8). Fourth, royal floors can be defined as the 15th to 25th floors in a 30-story high-rise housing structure based on the agreement of 50% of residents and 70% of realtors.