• 제목/요약/키워드: Utility Interface

Search Result 126, Processing Time 0.031 seconds

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.7 no.2
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.

A Wide Input Range Active Multi-pulse Rectifier For Utility Interface Of Power Electronic Converters

  • Hahn Jaehong;Enjeti Prasad N.;Park In-Gyu
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.512-517
    • /
    • 2001
  • In this paper, a wide input range active multi-pulse rectifier for utility interface of power electronic converters is proposed. The scheme combines multi-pulse method using a V-A transformer and boost rectifier modules. A current control scheme for the rectifier modules is proposed to achieve sinusoidal line currents in the utility input over a wide input range of input voltage and output load conditions. A design example is included for a 208V to 460V input, $700V_{dc}$ do 10kW output rectifier system. Simulation results are shown.

  • PDF

Utility Interactive Inverter with High-frequency Link for Photovoltaic Power System (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.W.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1050-1052
    • /
    • 2000
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system (3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation. a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Implementation of MPEG-21 DIA Utility Software for Stereoscopic Video Adaptation

  • Kwon Hyukmin;Kim Manbae
    • Journal of Broadcast Engineering
    • /
    • v.10 no.2
    • /
    • pp.139-148
    • /
    • 2005
  • This paper presents recent works of the development of MPEG-21 DIA utility software as one of MPEG-21 activities. The main purpose of this work is to make integrated utility software for DIA C/C++ modules in a Java framework. To do this, JNI plays a role of the interface of a main module with C/C++ DIA adaptation modules. Furthermore, DIA and DID parsers are integrated to the utility software. Our software is designed such that all DIA modules are easily integrated. A variety of adaptation modules have been adopted in MPEG-21 standard. Among them, stereoscopic video conversion that is one of DIA adaptation modules is chosen and we show that our utility software is correctly implemented based on experiments.

A Study on the Implementation of Automation Network for Power Utility using UCA and Fieldbus (UCA와 필드버스를 이용한 전력 설비 자동화 통신망 구축 방안 연구)

  • Choe, In-Ho;Hwang, In-Hwi;Hong, Seung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.6
    • /
    • pp.287-298
    • /
    • 2000
  • The UCA is a standard-based approach to utility communications which provides for wide scale integration of functional areas including customer interface, distribution, transmission, power plant, control center, and corporate information systems. Field devices in the power facilities require real-time communications, and they must be interconnected into fieldbus. This study introduces a method of implementing gateway that interfaces UCA and fieldbus. In this study, PROFIBUS and FOUNDATION Fieldbus are selected as candidate fieldbus protocols. Protocol interface in the gateway can be accomplished by mapping objects and services of UCA and fieldbus. MOst of the UCAs CASM objects and services are directly mapped into those of the application and user layers of fieldbus. However, some CASM services are not supported in the application and user layers of fieldbus. This study presents the method of implementing those services. In order to show that the implementation of interface is possible, this study presents pseudo-codes of interface program that maps the objects and services of UCA and fieldbus.

  • PDF

High frequency Linked Grid-Connected PV System for Residential Use (고주파링크 방식의 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.J.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1281-1283
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors a net size, weight, and parts cost saying result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

High frequency Linked Grid-Connected PV System for Residential Use (고주파링크 방식을 이용한 계통연계형 태양광발전시스템)

  • Jung, Y.S.;Yu, G.J.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.467-469
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kW) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kW high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier, four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

High-Frequency DC Link Inverter for Grid-connected PV System (계통연계형 태양광발전시스템을 위한 고주파 DC 링크 인버터)

  • Jung Young-Seok;Yu Gwon-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.46-49
    • /
    • 2001
  • An investigation into power conditioners that interface with photovoltaic array and utilities has been completed. The rating for this investigation is residential system(3-5kVA) that interface with a 220V single phase utility connection. As the result of this investigation, a 3kVA high frequency PWM IGBT inverter feeding a high frequency isolation transformer with a sinusoidal current wave was selected. The output of the transformer rectified with a diode bridge rectifier. four IGBT, used as 60Hz switched, reverse the polarity of the rectified current on every other half cycle of the utility voltage. Even though the high frequency link system used more power semiconductors, a net size, weight, and parts cost saving result compared to the other systems due to elimination of 60Hz transformer.

  • PDF

Evaluation of Planning Transparence of User Interface Reflecting State Schemas (스키마 개념을 도입한 사용자 계획수립의 용이도 평가)

  • ;Yoon, Wan Chul
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.17 no.2
    • /
    • pp.45-54
    • /
    • 1992
  • It become increasingly important to design user interface to carry low complexity. The cognitive limitations of users severely restrict utility of highly intelligent but complex modern systems. Since humans are known to use schemas to reduce cognitive complexity, imposing good consistency to an interface design that may help that user form useful schemas will provide powerful control over the complexity. This present a research effort to develop a quantitative method for evaluating interface complexity that the user would experience planning his or her course of action. Taking into account the user's potential schemas, a quantitative measure based on information theory was develped to assess the navigational complexity. This approach does not rely on the subjective judgment of the researcher as most schemes dealing with user schemas do. The proposed method may benefit the rapid prototyping approach to design a better user interface by allowing handy assessment of the design.

  • PDF

A Study on Improvement of the Interface Control of NPP Construction and Operation Activities

  • Chung, Ku-Young;Lee, Woo-Ho;Lee, Jae-Hun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.05a
    • /
    • pp.1221-1222
    • /
    • 2005
  • Interface control activities during the nuclear power plant (NPP) construction and operation have been reviewed for enhancing the safety of NPP. The primary focus of the study is given on analysis of lessons learned from the recent significant events of Korean Standard Nuclear Power plant (KSNP), such as a series of break-off of thermal sleeves at YGN 5 & 6 and radioactivity leak at YGN 5, in respect of interface control. Based on the results of the analysis, this study recommends measures for the improvement of interface control among utility and technical supporting organizations (TSO), and suggests new regulatory systems, such as reporting of safety significant non-conformances, to effectively verify the adequacy of interface control activities during construction and operation of NPPs.

  • PDF