• 제목/요약/키워드: Utility Grid

검색결과 244건 처리시간 0.029초

A Study of Islanding Detection of Grid-connected Three-phase Photovoltaic Power Conditioning System

  • Jung Y.S.;Yu G.J.;Choi J.Y.;Choi J.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.761-764
    • /
    • 2003
  • Islanding phenomenon of a grid-connected photovoltaic (PV) power conditioning system (PCS) is said to occur if the PCS continues to power a section of the utility system after that section has been disconnected from the utility source. Since islanding creates hazards for personnel and equipment, PCSs are required to detect and prevent Et. In this paper, several islanding detection methods (IDMs) and reactive power variation method are described. Islanding test results for 9kW PCS are presented for verification.

  • PDF

자동동기장치 성능평가를 위한 3상 정밀파형발생기 개발 (3-Phase High Precision Sinusodial Signal Generator for Performance Measure of Autosyncronizer)

  • 정태진;차영호;박호철;천영식;정찬수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.478-480
    • /
    • 1998
  • We develops a simulator to evaluate the performance of the autosyncronizer. The autosyncronizer is used to automatically syncronize magnitude, frequency, and phase of 3 phase signals of generator with respect to those of the utility grid. This autosyncronizer needs to be evaluated its performance to prevent malfunctions. To do this, 3 phase signals of generator and the utility grid are simulated and signals of the generator should be changed by ouput of the autosyncronizer with high precision. In this paper, we uses TMS320C31 to generate high precision sinusoidal 3 phase signals using Table Lookup method. In this process, it is very desirable to control magnitude, frequency, and phase of the signal with high precision and this is achieved by appropriate interpolation method. The resulted signal is well controlled and has low THD and could be used to evaluate the performance of the autosyncronizer.

  • PDF

무효전력 제어를 통한 새로운 독립운전 검출법 (A Novel Method for Anti-Islanding Using Reactive Power Control)

  • 정진범;최봉주;안강순;김희준
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권4호
    • /
    • pp.208-216
    • /
    • 2005
  • Recently, the study of islanding phenomenon, maintains its operation even when the utility grid is removed has lead to the trend of utility interactive inverters in photovoltaic generation systems. In this paper, a novel Anti-islanding method is presented. the proposed method can keep the real average power component constant by MPPT control and cause the load current frequency with only change of reactive power component under the islanding condition. its periodical change of Reactive power component can decrease the NDZ(Non-Detective zone) so that the detection of various loads will be possible. the insufficient effect if additional reactive power component to the grid is proved theoretically and the islanding detection is also confirmed from a experimental result with a inverter for 3kW photovoltaic generation system applied the proposed Anti-islanding method.

선박의 유동해석 문제에 대한 중첩격자기법(Suggar++)의 활용 (Application of the Overset Grid Scheme (Suggar++) for Flow Analysis around a Ship)

  • 김유철;김윤식;김진;김광수
    • 대한조선학회논문집
    • /
    • 제56권1호
    • /
    • pp.47-57
    • /
    • 2019
  • Recent CFD solvers in engineering have to treat geometrically complex domains and moving body problems. In ship hydrodynamics, flow around the stern and ship motions in waves are examples of such cases mentioned before. The unstructured grid scheme is successfully applied for these problems, but it has weakness of inefficient memory usage and intensive computational time as compared to the structured grid method. Overset grid scheme is one of the alternatives for structured grid system taking advantage of fast and memory efficiency. Overset grid scheme is especially useful for moving body problem because there is no need to re-mesh around the body. In this paper, we adopted the Suggar++, the grid connectivity and interpolation utility for the overlapping grid, to WAVIS which is the in-house flow solver of KRISO. Then we introduced some applications using the overset grid method for flow analysis around the ships. The computed results show that WAVIS with Suggar++ is practically feasible and has an advantages for moving geometry cases.

Compensation Strategy to Eliminate the Effect of Current Measurement Offsets in Grid-Connected Inverters

  • Lee, Chang-Hee;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • 제14권2호
    • /
    • pp.383-391
    • /
    • 2014
  • For the digital control of systems such as grid-connected inverters, measuring inverter output currents accurately is essential. However, current measurement offsets are inevitably generated by current measurement paths and cause DC current components in real inverter output currents. Real inverter output currents with DC components cause the DC-link capacitor voltage to oscillate at the frequency of a utility voltage. For these reasons, current measurement offsets deteriorate the overall system performance. A compensation strategy to eliminate the effect of current measurement offsets in grid-connected inverters is proposed in this study. The validity of the proposed compensation strategy is verified through simulations and experiments. Results show that the proposed compensation strategy improves the performance of grid-connected inverters.

계통 연계형 태양광 발전 인버터의 디지털 제어 (Digital Control of Utility-Connected PV Inverter)

  • 김용균;최종우;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1161-1165
    • /
    • 2004
  • The fundamental digital control of utility-connected PV inverter are presented with detailed analysis and simulation and experimental results. PLL controller using virtual two phase detector, current controller of DC-DC converter, dc link voltage controller and inverter current controller are discussed. The novel PLL controller using virtual two phase detector can detect the information of utility voltage instantaneously and is not sensitive to the noise. Current controller of DC-DC converter, dc link voltage controller and inverter current controller are the conventional methods. We have constructed utility-Connected PV Inverter and applied to those controllers. The simulation and experimental results demonstrate an excellent performance in the single-phase grid-connected operation.

  • PDF

전력 HILs를 활용한 스마트 인버터의 LVRT 시험 (Low Voltage Ride Through Test for Smart Inverter in Power Hardware in Loop System)

  • Sim, Junbo
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.101-105
    • /
    • 2021
  • Encouragement of DER from Korean government with several policies boosts DER installation in power system. When the penetration of DER in the grid is getting high, loss of generation with break-away of DER by abnormal grid conditions should be considered, because loss of high generation causes abnormal low frequency and additional operations of protection system. Therefore, KEPCO where is Korean power utility is preparing improvement in regulations for DERs connected to the grid to support abnormal grid conditions such as low and high frequencies or voltages. This is called 'Ride Through' because the requirement is for DER to maintain grid connection during required periods when abnormal grid conditions occur. However, it is not easy to have a test for ride through capability in reality because emulation of abnormal grid conditions is not possible in real power system in operation. Also, it is not easy to have a study on grid effect when ride through capability fails with the same reason. PHILs (Power Hardware In the Loop System) makes it possible to analyze power system and hardware performance at once. Therefore, this paper introduces PHILs test methods and presents verification of ride through capability especially for low voltage grid conditions.

Wi-SUN을 이용한 메시지 동시동보 방송 시스템 구성 (The Concurrent Message Broadcasting and Speaking System using Wireless Smart Utility Network)

  • 김재수;판이첸
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2019년도 제60차 하계학술대회논문집 27권2호
    • /
    • pp.329-330
    • /
    • 2019
  • 스마트 유틸리티 네트워크 (SUN)는 가정, 빌딩, 공장 등에서 사용하는 전기, 수도, 가스와 같은 유틸리티를 효과적으로 관리할 수 있는 통신 네트워크 기술이다. 본 논문은 IEEE 802.15.4g 표준에 기반하는 Wireless-SUN 네트워크를 이용하여 원격 검침과 음성 동보 시스템을 구현하는 방안을 제시한다.

  • PDF

Communication Architecture of the IEC 61850-based Micro Grid System

  • Yoo, Byong-Kwan;Yang, Seung-Ho;Yang, Hyo-Sik;Kim, Won-Yong;Jeong, Yu-Seok;Han, Byung-Moon;Jang, Kwang-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권5호
    • /
    • pp.605-612
    • /
    • 2011
  • As the power grids are integrated into one big umbrella called a "smart grid," communication protocol plays a key role in successful operations. The successful deployment of smart grid interoperability is a major hurdle that must be overcome. The micro grid, a small power system that distributes energy resource, is operated in diverse regions. Different vendors use different communication protocols in the operation of the micro grid. Recently, the IEC 61850 has been legislated to solve the interoperability problems in power utility automation. The present paper presents a micro grid system based on the IEC 61850 protocol. It consists of a micro grid monitoring system, a protocol converter that transforms serial data to IEC 61850 data, and distributed energy resource controllers for diverse DER nodes. A developed communication gateway can be deployed for DER controllers with serial links to exchange data with IEC 61850-based devices. The gateway can be extended to IEC 61850-based distribution automation systems, substation automation systems, or SCADA.

스마트 그리드 지원을 위한 컴퓨터 기반 3상 전력 데이터 수집 솔루션 개발 (The Development of Collection Solution of the Three-Phase Power Data based on the Personal Computer for Supporting the Smart Grid)

  • 고윤석
    • 한국전자통신학회논문지
    • /
    • 제6권4호
    • /
    • pp.553-558
    • /
    • 2011
  • 스마트 그리드는 기존의 전력망에 디지털 정보망을 결합한 지능형 전력망으로 전력공급자와 사용자간에 양방향 통신을 통해서 전력을 공급 및 제어함으로써 전기 에너지 이용 효율을 극대화한다. 본 연구에서는 스마트 그리드를 지원하기 위해 스마트 수용가를 위한 컴퓨터 기반의 병렬 통신을 이용한 3상 전력 데이터 수집 솔루션을 설계하고 그 시작품을 제작하는 것을 연구목표로 한다.