• Title/Summary/Keyword: Using time

Search Result 81,041, Processing Time 0.082 seconds

The Use of Real-Time Ultrasound Imaging for Feedback during Abdominal Hollowing (복부 할로잉 운동에서 실시간 초음파 영상 피드백의 사용 효과)

  • Kwon, Nam-Hee;Lee, Hyun-Ok;Park, Du-Jin
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.3
    • /
    • pp.303-310
    • /
    • 2011
  • Purpose : This study examined the feedback effect of real-time ultrasound imaging on the thickness of transversus abdominis(TrA), internal abdominal oblique(IO) and external abdominal oblique(EO) during abdominal hollowing exercise(AHE) in crook lying. Methods : We performed this study on 30 healthy men who voluntarily consented to participate in this study after listening to its purpose and method. All subject were divided into an experimental group(n=15) with using the real-time ultrasound imaging feedback(RUIF) and a control group(n=15) without the RUIF The thickness changes between rest and AHE were compared between the two groups in crook lying. Results : The difference in TrA and EO thickness changes between the groups were significant in crook lying (p<0.05). Conclusion : The group with using real-time ultrasound imaging feedback showed a higher increase in the thickness of TrA than the other group without real-time ultrasound imaging feedback. And the thickness of EO in the group with using real-time ultrasound imaging feedback decreased than the other group without real-time ultrasound imaging feedback. If the muscle thickness can be regarded as an indicator of muscle activity, RUIF will be helpful for inducing the independent activity of TrA by reducing the activities of abdominal muscles such as EO.

On-Line Feed-Forward Dead-Time Compensation Method (온라인 전향 데드타임 보상기법)

  • 김현수;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.267-274
    • /
    • 2004
  • In this paper, a new on-line dead-time compensation method is proposed. The output voltage errors due to the dead-time effect is considered as disturbance voltages. The magnitude of the disturbance voltages is estimated using a time delay control technique and the disturbance voltages are calculated using the estimated values, measured currents, and position information. The calculated disturbance voltages are fed to voltage references in order to compensate the dead-time effect. The proposed method is applied to a PM synchronous motor drive system and implemented in a digital manner using a digital signal processor (DSP) TMS320C31. The experiments are carried out for this system to show the effectiveness of the proposed method and the results show the validity of the proposed method.

Pre- and In-Hospital Delay in Treatment and in-Hospital Mortality after Acute Myocardial Infarction

  • An, Kyuneh;Koh, Bongyeun
    • Journal of Korean Academy of Nursing
    • /
    • v.33 no.8
    • /
    • pp.1153-1160
    • /
    • 2003
  • Purpose. 1) To identify the time taken from symptom onset to the arrival at the hospital (pre-hospital delay time) and time taken from the arrival at the hospital to the initiation of the major treatment (in-hospital delay time) 2) to examine whether rapid treatment results in lower mortality. 3) to examine whether the pre- and in-hospital delay time can independently predict in-hospital mortality. Methods. A retrospective study with 586 consecutive AMI patients was conducted. Results. Pre-hospital delay time was 5.25 (SD=10.36), and in-hospital delay time was 1.10 (SD=1.00) hours for the thrombolytic therapy and 50.24 (SD=121.18) hours for the percutaneous transluminal coronary angio-plasty (PTCA). In-hospital mortality was the highest when the patients were treated between 4 to 48 hours after symptom onset using PTCA (p=.02), and when treated between 30 minutes and one hour after hospital arrival using thrombolytics (p=.01). Using a hierarchical logistic regression model, the pre- and in-hospital delay times did not predict the in-hospital mortality. Conclusion. Pre- and in-hospital delay times need to be decreased to meet the desirable therapeutic time window. Thrombolytics should be given within 30 minutes after arrival at the hospital, and PTCA should be initiated within 4 hours after symptom onset to minimize in-hospital mortality of AMI patients.

Compression of time-varying volume data using Daubechies D4 filter (Daubechies D4 필터를 사용한 시간가변(time-varying) 볼륨 데이터의 압축)

  • Hur, Young-Ju;Lee, Joong-Youn;Koo, Gee-Bum
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.982-987
    • /
    • 2007
  • The necessity of data compression scheme for volume data has been increased because of the increase of data capacity and the amount of network uses. Now we have various kinds of compression schemes, and we can choose one of them depending on the data types, application fields, the preferences, etc. However, the capacity of data which is produced by application scientists has been excessively increased, and the format of most scientific data is 3D volume. For 2D image or 3D moving pictures, many kinds of standards are established and widely used, but for 3D volume data, specially time-varying volume data, it is very difficult to find any applicable compression schemes. In this paper, we present a compression scheme for encoding time-varying volume data. This scheme is aimed to encoding time-varying volume data for visualization. This scheme uses MPEG's I- and P-frame concept for raising compression ratio. Also, it transforms volume data using Daubechies D4 filter before encoding, so that the image quality is better than other wavelet-based compression schemes. This encoding scheme encodes time-varying volume data composed of single precision floating-point data. In addition, this scheme provides the random reconstruction accessibility for an unit, and can be used for compressing large time-varying volume data using correlation between frames while preserving image qualities.

  • PDF

The Bus Delay Time Prediction Using Markov Chain (Markov Chain을 이용한 버스지체시간 예측)

  • Lee, Seung-Hun;Moon, Byeong-Sup;Park, Bum-Jin
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.8 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • Bus delay time is occurred as the result of traffic condition and important factor to predict bus arrival time. In this paper, transition probability matrixes between bus stops are made by using Markov Chain and it is predicted bus delay time with them. As the results of study, it is confirmed a possibility of adapting the assumption which it has same bus transition probability between stops through paired-samples T-test and overcame the limitation of exiting studies in case there is no scheduled bus arrival time for each stops with using bus interval time. Therefore it will be possible to predict bus arrival time with Markov Chain.

  • PDF

A real-time QRS complex detection algorithm using topological mapping in ECG signals (심전도 신호의 위상학적 팹핑을 이용한 실시간 QRS 검출 알고리즘)

  • 이정환;정기삼;이병채;이명호
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.48-58
    • /
    • 1998
  • In this paper, we proposed a new algorithm using characteristics of th ereconstructed phase trajectory by topological mapping developed for a real-tiem detection of the QRS complexes of ECG signals. Using fill-factor algorithm and mutual information algorithm which are in genral used to find out the chaotic characteristics of sampled signals, we inferred the proper mapping parameter, time delay, in ECG signals and investigated QRS detection rates with varying time delay in QRS complex detection. And we compared experimental time dealy with the theoretical one. As a result, it shows that the experimental time dealy which is proper in topological mapping from ECG signals is 20ms and theoretical time delays of fill-factor algorithm and mutual information algorithm are 20.+-.0.76ms and 28.+-.3.51ms, respectively. From these results, we could easily infer that the fill-factor algorithm in topological mapping from one-dimensional sampled ECG signals to two-dimensional vectors, is a useful algorithm for the detemination of the proper ECG signals to two-dimensional vectors, is a useful algorithm for the detemination of the proper time delay. Also with the proposed algorithm which is very simple and robust to low-frequency noise as like baseline wandering, we could detect QRS complex in real-time by simplifying preprocessing stages. For the evaluation, we implemented the proposed algorithm in C-language and applied the MIT/BIH arrhythmia database of 48 patients. The proposed algorithm provides a good performance, a 99.58% detection rate.

  • PDF

Time-domain analyses of the layered soil by the modified scaled boundary finite element method

  • Lu, Shan;Liu, Jun;Lin, Gao;Wang, Wenyuan
    • Structural Engineering and Mechanics
    • /
    • v.55 no.5
    • /
    • pp.1055-1086
    • /
    • 2015
  • The dynamic response of two-dimensional unbounded domain on the rigid bedrock in the time domain is numerically obtained. It is realized by the modified scaled boundary finite element method (SBFEM) in which the original scaling center is replaced by a scaling line. The formulation bases on expanding dynamic stiffness by using the continued fraction approach. The solution converges rapidly over the whole time range along with the order of the continued fraction increases. In addition, the method is suitable for large scale systems. The numerical method is employed which is a combination of the time domain SBFEM for far field and the finite element method used for near field. By using the continued fraction solution and introducing auxiliary variables, the equation of motion of unbounded domain is built. Applying the spectral shifting technique, the virtual modes of motion equation are eliminated. Standard procedure in structural dynamic is directly applicable for time domain problem. Since the coefficient matrixes of equation are banded and symmetric, the equation can be solved efficiently by using the direct time domain integration method. Numerical examples demonstrate the increased robustness, accuracy and superiority of the proposed method. The suitability of proposed method for time domain simulations of complex systems is also demonstrated.

Time-domain Computation of Broadband Noise due to Turbulence-Cascade Interaction (난류-캐스케이드 상호 작용에 의한 광대역 소음장의 시간영역 계산)

  • Cheong, Cheol-Ung;Jeong, Sung-Su;Cheung, Wan-Sup;Lee, Soo-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.812-817
    • /
    • 2005
  • The objective of the present work is to develop a time-domain numerical method of broadband noise in a cascade of airfoils. This paper focuses on dipole broadband noise sources, resulting from the interaction of turbulent inflows with the flat-plate airfoil cascade. The turbulence response of a two-dimensional cascade is studied by solving both of the linearised and full nonlinear Euler equations employing accurate higher order spatial differencing, time stepping techniques and non-reflecting inflow/outflow boundary condition. The time-domain result using the linearised Euler equations shows good agreement with the analytical solution using the modified LINSUB code. Through the comparison of the nonlinear time-domain result using the full nonlinear Euler equations with the linear, it is found that the acoustic mode amplitude of the nonlinear response is less than that of the linear response due to the energy cascade from low frequency components to the high frequency ones. Considering the merits of the time-domain methods over the typical time-linearised frequency-domain analysis, the current method is expected to be promising tools for analyzing the effects of the airfoil shapes, non-uniform background flow, linear-nonliear regimes on the broadband noise due to gust-cascade interaction.

  • PDF

A Study of Air-source Heat Pump Performance Analysis for Replacing Night Time Electric Heating Boiler (심야전기보일러 대체용 공기열 히트펌프 성능평가)

  • Jo, J.Y.;Jung, H;Lee, C.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.81-85
    • /
    • 2011
  • The night time electric cost is cheaper due to electric supply and demand policy in Korea from 1985. Currently about 900,000 customers are using night time electric heating boilers and this causes shift of peak demand time to night in winter and increase of deficit spending. To solve this problem, replacing night time electric heating boiler by air-source heat pump using night time electricity has been proposed. An air-source heat pump can provide efficient heating equipment especially in a warm climate. For estimating the night time electric heat pump COP(Coefficient of Performance), Korean Standard KS C 9306:2010 and European Standard EN-14511:2004 is available. SCOP(Seasonal COP) using European weather bin data is also calculated. SCOP is not available yet but European Committee for Standardization will establish a standard in the near future. The evaluation result show that the replacing night time electric heating boiler by heat pump can be possible.

Performance Characteristics for the Variation of Altitude and Tilt Angle in the Satellite Imager Using Time Delay and Integration(TDI) (Time Delay and Integration(TDI)을 사용하는 위성 영상 기기의 고도 및 촬영각 변화에 대한 성능 특성)

  • 조영민
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.2
    • /
    • pp.91-96
    • /
    • 2002
  • The performance characteristics of a satellite imager using a Time Delay and Integration(TDI) Charge Coupled Device (CCD) with fixed integration time is investigated for the variation of satellite altitude and tilt angle. In consequence of the investigation TDI synchronization using tilt imaging is proposed as a solution to compensate geometric performance degradation due to altitude decrease. The tilt angle optimized for the TDI synchronization at decreased altitude is presented. This result can be used for a TDI CCD imager with variable integration time in a certain range as well.