Kim, Hong-Jun;Kim, Jee-Hwan;Kim, Sung-Tae;Lee, Jae-Hoon;Park, Young-Bum
The Journal of Korean Academy of Prosthodontics
/
v.49
no.4
/
pp.346-353
/
2011
Purpose: The peri-implant soft tissue is remodeled by the initial marginal bone resorption affecting the prognosis and esthetic result of treatment. Thus various designs on implant neck design are studied to preserve peri-implant bone. The purpose of this study is to review on the causes of initial marginal bone resorption, the configuration of peri-implant soft tissue, and the implant crestal module favorable in preserving peri-implant tissue. Materials and methods: The studies on the causes of initial marginal bone resorption and the implant crestal modules are researched and reviewed using Pubmed database. The implant crestal modules including one piece and two-piece implant, internal and external hex abutment, taper and butt joint connection, scalloped design abutment, and platform switching concept are reviewed. Results: A number of clinical and experimental studies preferred one piece implant to two-piece in preserving initial peri-implant tissue. For two piece implants, internal hex abutment and taper joint connection appear more favorable than external hex abutment and butt joint connection relatively. Controversial issues still exist on scalloped design requiring more studies on it. Although the rationale is not certain, the concept of platform switching seems favorable in preserving initial peri-implant tissue based on clinical and experimental studies. Conclusion: Each implant crestal module contains its own advantages and disadvantages with various controversial issues. In the aspect of preservation of initial peri-implant tissue, however, one-piece implant seems beneficial. In cases when two-piece implant is more appropriate due to prosthodontic concerns or any other problems, the application of platform switching concept, internal connection abutment, and taper joint connection may be favorable for the preservation of peri-implant tissues.
Pae, Ah-Ran;Won, Hyun-Du;Lee, Richard Sung-Bok;Kim, Hyeong-Seob;Woo, Yi-Hyung
The Journal of Korean Academy of Prosthodontics
/
v.49
no.4
/
pp.333-340
/
2011
Purpose: The aim of this study was to study the effect of hydroxyapatite (HA) coating crystallinity on the proliferation and differentiation of human osteosarcoma cells. Materials and methods: Surface roughness of the titanium disks increased by anodizing treatment and then HA was coated using ion beam-assisted deposition (IBAD). HA coating was crystallized by heat-treated at different temperature ($100^{\circ}C$, $300^{\circ}C$, $500^{\circ}C$, $800^{\circ}C$). According to the temperature, disks were divided into four groups (HA100, HA300, HA500, HA800). With the temperature, crystallinity of the HA coating was different. Anodized disks were used as control group. The physical properties of the disk surface were evaluated by surface roughness tests, XRD tests and SEM. The effect of the crystallinity of HA coating on HOS cells was studied in proliferation and differentiation. HOS cells were cultured on the disks and evaluated after 1, 3, 5, and 7 days. Growth and differentiation kinetics were subsequently investigated by evaluating cell proliferation and alkaline phosphatase activity. Results: Regardless of the heat-treated temperature, there is no difference on the surface roughness. Crystallinity of the HA was appeared in the groups of HA500, HA800. HOS cells proliferation, ALP activity were higher in HA500 and HA800 group than HA100 and HA300. Conclusion: Within the results of this limited study, heat treatment at $500^{\circ}C$ of HA coating produced by IBAD has shown greater effect on proliferation and differentiation of HOS cells. It is considered that further in vivo study will be necessary.
Purpose: Resonance frequency analysis, Periotest, and removal torque (RT) test were known as the methods to assess implant stability. The results of these methods are affected by the bone condition, implant diameter and shape. The purpose of this study is to access the meaning and the correlationship of the resonance frequency analysis, Periotest and RT test in osseointegration simulated acrylic resin when the engaged bone thickness and peri-implant bone defect are changed. Materials and methods: To simulate osseointegration, the fixture was fixed to an aluminum mold with a screw. Acrylic resin powder and liquid were poured into the mold for polymerization. The engaged resin thickness with implant was controlled. Simulated cortical bone thicknesses were 1, 3, 5 and 10 mm. Additional 1, 3 and 5 mm peri-implant bone defects were simulated. Three types of implants were used; 4 mm diameter implants of straight shape, 4 mm diameter implants of tapered shape and 5 mm diameter implants of tapered shape. Five fixtures per each type were tested in respective bone condition. Resonance frequency analysis and Periotest were evaluated in all bone conditions. Peak removal torque was measured at simulated cortical bone thicknesses of 1 and 3 mm. The statistical analysis was performed with the Kruskal-Wallis test, Mann-Whitney U test, and Spearman test using a 95% level of confidence. Results: With increasing engaged bone depth, the Implant Stability Quotient (ISQ) values increased and the Periotest values (PTVs) decreased (P<.001, P<.001). With increasing peri-implant bone defect, ISQ values decreased and PTVs increased (P<.001). When the diameter of implant increased, ISQ values increased and Periotest values (PTV) decreased (P<.001). There was a strong correlation between ISQ values and PTVs (r = -0.99, P<.001). Furthermore, the peak removal torque values had weak correlations with both ISQ values and PTVs (r = 0.52, P<.001 ; r = -0.52, P<.001). Conclusion: This study confirmed favorable implant stability with increasing engaged bone depth and implant diameter and decreasing peri-implant bone defect. ISQ values and PTVs showed strong correlation with each other and not with the peak removal torque values.
Kim, Min-Ho;Yeo, In-Sung;Kim, Sung-Hun;Han, Jung-Seok;Lee, Jai-Bong;Yang, Jae-Ho
The Journal of Korean Academy of Prosthodontics
/
v.49
no.2
/
pp.168-176
/
2011
Purpose: This study aims at investigating the influence of various insertion torques on thermal changes of bone. A proper insertion torque is derived based on the thermal analysis with two different implant designs. Materials and methods: For implant materials, bovine scapula bone of 15 - 20 mm thickness was cut into 35 mm by 40 - 50 mm pieces. Of these, the pieces having 2 - 3 mm thickness cortical bone were used as samples. Then, the half of the sample was immersed in a bath of $36.5^{\circ}C$ and the other half was exposed to ambient temperature of $25^{\circ}C$, so that the inner and surface temperatures reached $36.5^{\circ}C$ and $28^{\circ}C$, respectively. Two types of implants ($4.5{\times}10\;mm$ Br${\aa}$nemark type, $4.8{\times}10\;mm$ Microthread type) were inserted into bovine scapula bone and the temperature was measured by a thermocouple at 0.2 mm from the measuring point. Finite element method (FEM) was used to analyze the thermal changes at contacting surface assuming that the sample is a cube of $4\;cm{\times}4\;cm{\times}2\;cm$ and a layer up to 2 mm from the top is cortical bone and below is a cancellous bone. Boundary conditions were set on the basis of the shape of cavity after implants. SolidWorks was used as a CAD program with the help of Abaqus 6.9-1. Results: In the in-vitro experiment, the Microhead type implant gives a higher maximum temperature than that of the Br${\aa}$nemark type, which is attributed to high frictional heat that is associated with the implant shape. In both types, an Eriksson threshold was observed at torques of 50 Ncm (Br${\aa}$nemark) and 35 Ncm (Microthread type), respectively. Based on these findings, the Microthread type implant is more affected by insertion torques. Conclusion: This study demonstrate that a proper choice of insertion torque is important when using a specific type of implant. In particular, for the Microthread type implant, possible bone damage may be expected as a result of frictional heat, which compensates for initial high success rate of fixation. Therefore, the insertion torque should be adjusted for each implant design. Furthermore, the operation skills should be carefully chosen for each implant type and insertion torque.
Statement of problem: Proper finishing and polishing enhance both the esthetics and the longevity of restored teeth. Blade finishing technique would be suited for smoothing and finishing. Evaluation of this technique are necessary. Purpose: The purpose of this study was to evaluate the blade finishing and polishing procedures on the surface profile and roughness of ormocer-based composite resin and nanohybrid composite resin. Material and methods: The material included a ormocer-based composite resin ($Admira^{(R)}$ & $Admira^{(R)}$ Flow); a nanohybrid composite resin ($Grandio^{(R)}$ & $Grandio^{(R)}$ Flow). One hundred forty specimens of each group were prepared using a mylar strip and randomly divied into blade finishing and rubber polishing groups (n=10). The average surface roughness (Ra) in micrometers was measured and the surface profile was examined by scanning electron microscopy (SEM) (Magnification ${\times}$ 200). The data were analyzed by Mann-Whitney Test at 0.05 significance level. Conclusion: The results of this study indicated that the mylar strip produced the smoothest surface on all materials and among the finishing-polishing methods was not significanct difference (P>0.05). Ormocer-based flowable composite resin performedthe lowest variability in initial surface roughness among the tested materials.
Park, Jae-Kyoung;Jeong, Chang-Mo;Jeon, Young-Chan;Yoon, Ji-Hoon
The Journal of Korean Academy of Prosthodontics
/
v.46
no.2
/
pp.137-147
/
2008
Statement of problem: Dental implant procedure has been recognized as a very effective treatment to rehabilitate fully or partially edentulous patients. However, mechanical failures such as screw loosening, screw fracture have been still reported frequently. Purpose: The purpose of this study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on implant-abutment screw loosening of three different joint connections after one million cyclic loading. Material and methods: The values of detorque before and after loading were measured in three different joint connections (Osstem Implant, Korea), one external butt joint, US II implant system and two internal cones, SS II and GS II system. The values of detorque before loading was analyzed by one-way ANOVA, and two-way ANOVA and Scheffe' test were performed for the value of detorque after loading. Results: 1. The values of initial detorque of tungsten carbide/carbon coated Ti alloy screw were smaller those of Ti alloy screw (P<.01), and there were no differences among implant systems in each screw (P>.05). 2. In comparison of loss rate of detorque value after cyclic loading, US II system was greater than SS II and GS II system but there was no difference between SS II and GS II system (P<.01). 3. Loss rates of detorque value after cyclic loading decreased consistently at tungsten carbide/carbon coated Ti alloy screw comparing with Ti alloy screw in all implant systems (P<.01), and there were no differences among three systems in reduction of loss rates by using tungsten carbide/carbon coated Ti alloy screw (P>.05). Conclusion: Tungsten carbide/carbon coating to increase preload with reduction of friction resistance was a effective way to decrease screw loosening by functional loading.
Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.
Journal of the korean academy of Pediatric Dentistry
/
v.32
no.3
/
pp.576-583
/
2005
Tooth formation is a complex developmental process that is mediated through a series of reciprocal epithelial-mesenchymal interactions. Several signal pathways and transcription factors have been implicated in regulating molar crown development, but relatively little is known about the regulation of root development. It was reported that NFI-C knockout mice showed abnormal root formation with normal crown. The aims of this study are to elucidate how the NFI-C regulate the determine of root shape and odontoblasts differentiation. We carried out immunohistochemistry using cytokeratin to investigate the role of Hertwig's epithelial root sheath and DSPP mRNA in-situ hybridization to conform the nature of root dentin during root development in NFI-C knockout mice. Cytokeratin reacted with all the HERS cells and the continuity of cytokeratin positive cells between the HERS cells and enamel epithelium was lost in the cervical region both wild and K/O types. After root dentin deposition cytokeratin positive-HERS cells showed irregularity and loss of polarity in the cervical region in K/O type. DSPP mRNA was strongly expressed in odontoblasts of crown and root dentin in wild type mice, whereas expression of DSPP mRNA was restricted in odontoblast of crown dentin in the K/O type. During root formation in NFI-C knockout mice, HERS normally grow out of the crown but fail to induce odontoblast differentiation in root portion. These results suggest that NFI-C may play important roles in odontoblast differentiation during root dentin formation.
Kim, Jae-Gon;Kim, Young-Jin;Kim, Young-Sin;Baik, Byeong-Ju
Journal of the korean academy of Pediatric Dentistry
/
v.28
no.4
/
pp.613-619
/
2001
The aims of this study were to compare the accuracy, sensitivity and specificity of cnventional visual examination, radiography and a new laser fluorescence method, KaVo Diagnodent, for the detection of occlusal caries lesions. One hundred sound human premolars and molars which had no restorations or interproximal cavities were tested by three methods. Tooth lesions depth was assessed at histologic examination using Caries detector dye The following results were obtained. 1. Diagnodent show 7.8 in sound tooth, 25.4 in initial caries, 30.5 in enamel caries, and 53.8 in dentin caries with average score 2. Spearman and Pearson relation coefficient was high between tooth-specimen test with dye and Diagnodent(0.736, 0.619), visual examination(0.664, 0.666), and was low between tooth-specimen test with dye and radiographic examination(P<0.01, total) 3. Accuracy of occlusal caries was highest on Diagnodent(65%) and lowest on radiographic examination(35%) 4. In initial caries, the sensitivity and specificity of Diagnodent method was the highest. In enamel caries, the sensitivity of visual examination was the highest and specificity of Diagnodent method was the highest. In dentinal caries, the sensitivity and specificity of Diagnodent method was the highest and sensitivity of visual examination was the lowest.
Journal of the korean academy of Pediatric Dentistry
/
v.28
no.4
/
pp.583-592
/
2001
This study was undertaken to evaluate the clinical effect of inhibiting plaque formation of Lactococcus lactis 1370, a acid producing bacterium residing in the mouth. 30 children were asked to use 10ml of control mouth-wash and mouthwash containing Lactococcus lactis 1370. The plaque index and plaque area rate at 24h and 48h after the use of the mouthwashes were measured. And the number of Lactococcus lactis 1370 was counted at 1h, 3h, and 6h in the mouth. The results are as follow. 1. The mean plaque index at 24h after the use of the control mouthwash and the mouthwash containing Lactococcus lactis 1370 were 2.43 and 2.06, respectively. The inhibiting rate of plaque formation was 15% (P<0.05). 2. The mean plaque index at 48h after the use of the control mouthwash and the mouthwash containing Lactococcus lactis 1370 were 2.95 and 2.17, respectively. The inhibiting rate of plaque formation was 26%, showing more decrease than at 24h(P<0.05). 3. The mean plaque area rate at 24h after the use of the control mouthwash and the mouthwash containing Lactococcus lactis 1370 were 21.2% and 15.6%, respectively. The inhibiting rate of plaque formation was 26% (P<0.05). 4. The mean plaque area rate at 48h after the use of the control mouthwash and the mouthwash containing Lactococcus lactis 1370 were 33.0% and 17.8%, respectively. The inhibiting rate of plaque formation was 46% (P<0.05). 5. The number of Lactococcus lactis 1370 in the mouth decreased significantly from mouthwashing to 3h, but increased slightly between 3h and 6h. As seen with the above results, we think that using the mouth wash with Lactococcus lactis 1370 would prevent the formation of plaque in the mouth and can be an effective method to prevent dental caries and periodontal disease.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.