• Title/Summary/Keyword: Used Blade

Search Result 1,088, Processing Time 0.03 seconds

Turbine Case Containment Capability Evaluation Using Finite Element Analysis (유한요소해석을 이용한 터빈 케이스의 컨테인먼트 성능 평가)

  • Jun-woo Baek;Sang-woo Kim;Soo-yong Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.5
    • /
    • pp.19-27
    • /
    • 2023
  • In this study, we used finite element analysis to conduct a containment capability evaluation of a turbine case. When analyzing the impact behavior of structures subjected to impact loads, it is important to consider the strain rate, as it affects the increase in flow stress. Therefore, we applied three material models (Cowper-Symonds, Johnson-Cook, and Modified Johnson-Cook) for the impact analysis. To validate these material models, we performed an impact test on an aluminum 6061 plate. By comparing and analyzing the experimental and analytical results, we determined that the Modified Johnson-Cook material model exhibited the least error. As a result, we applied this material model to evaluate the containment capability of the turbine case. This evaluation involved determining the occurrence of penetration, as well as the stress and strain induced at the collision area due to the initial velocity of the blade.

Performance Evaluation of WWTP Based on Reliability Concept (신뢰성에 기초한 하수처리장 운전효율 평가)

  • Lee, Doo-Jin;Sun, Sang-Woon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.348-356
    • /
    • 2007
  • Statistical and probabilistic method was used in the analysis of data, which is the most effective one in describing the various natures, and the methodology relating the results with the design was developed. Influents and effluents of three treatment plants were analyzed and the focus was made on BOD, COD, SS, IN, TP The fluctuations of influent such as BOD, COD, SS were extremely large and their standard deviations(st.dev) were more than 10 mg/L. but those of TN, TP were small; the st.dev was 6.6 mg/L for TN, 0.6 mg/L for TP, respectively. But, effluent concentration showed consistent pattern regardless of the influent fluctuations, the st.dev was ranged between 0.28 and 4.48 mg/L. Effluent distributional characteristics were as follows; BOD, COD were distributed normally, but SS, TN, and TP, log-normally; unsymmetric and skewed to the right. The coefficient of reliability(COR) based on the results of statistics of data was introduced to evaluate the process performance an4 to reflect the process performance to the process design. The coefficient of reliability relates the design value(the goal) with the standards and it can be used in operating treatment facilities under a certain reliability level and/or in evaluating the reliability of the treatment facilities on operation. Each treated water quality of effluent showed the half of water quality standards in the level of 50% percentile and all treatment plant was achieved 100% probability of water quality standards. It was concluded that the variability of the process performance should be reflected to the design procedure and the standards through the analysis based on the statistics and the probability.

Changes in Quality of Salted and Dried Brown-Croaker Product Prepared with Deep Seawater Salt (해양심층수 소금을 이용한 민어 염건품 제조 및 저장 중 품질 변화)

  • Joo, Dong-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.2
    • /
    • pp.235-244
    • /
    • 2011
  • The physicochemical properties and quality changes in salted and dried brown croaker products using deep seawater salt were investigated for preparation with different pretreatment, salting and drying conditions. Optimum salt concentration, salting time and drying time for product were 20% of body weight, 12 hrs at room temperature ($25{\pm}2^{\circ}C$), and 24 hrs at $30{\pm}2^{\circ}C$, respectively. The volatile basic nitrogen (VBN), peroxide value (POV), viable cell count and acid value (AV) of viscera and blade removed products were 18.9~22.4 mg%, 21.0~32.5 meq/L, and 2.3~4.4 mg/mL, $2.0\sim3.5{\times}10^3$ CFU/g, respectively and only viscera removed products were 31.2~38.1 mg%, 40~55.2 meq/L, 7.0~11.5 mg/mL, $4.1\sim5.5{\times}10^3$ CFU/g, respectively. Changes in quality of salted and dried brown croaker products were investigated during storage at room temperature and $5{\pm}2^{\circ}C$. The POV, AV and viable cell counts of salted and dried brown croaker products increased in commercial salt used and only viscera removed products compared with deep seawater salt used and viscera and blade removed products during storage time. Results in this study showed that the deep seawater salt was very effective for quality control of salted and dried brown croaker products and pretreatment method was a very important factor for preparation products. The optimum conditions for preparation of salted and dried brown croaker product were 20% of body weight for salt concentration, 12 hrs at $25{\pm}2^{\circ}C$ for salting time, and 24 hrs at $30{\pm}2^{\circ}C$ for drying time. Optimum storage time for quality maintenance was 14 days at $5{\pm}2^{\circ}C$.

Progress of Composite Fabrication Technologies with the Use of Machinery

  • Choi, Byung-Keun;Kim, Yun-Hae;Ha, Jin-Cheol;Lee, Jin-Woo;Park, Jun-Mu;Park, Soo-Jeong;Moon, Kyung-Man;Chung, Won-Jee;Kim, Man-Soo
    • International Journal of Ocean System Engineering
    • /
    • v.2 no.3
    • /
    • pp.185-194
    • /
    • 2012
  • A Macroscopic combination of two or more distinct materials is commonly referred to as a "Composite Material", having been designed mechanically and chemically superior in function and characteristic than its individual constituent materials. Composite materials are used not only for aerospace and military, but also heavily used in boat/ship building and general composite industries which we are seeing increasingly more. Regardless of the various applications for composite materials, the industry is still limited and requires better fabrication technology and methodology in order to expand and grow. An example of this is that the majority of fabrication facilities nearby still use an antiquated wet lay-up process where fabrication still requires manual hand labor in a 3D environment impeding productivity of composite product design advancement. As an expert in the advanced composites field, I have developed fabrication skills with the use of machinery based on my past composite experience. In autumn 2011, the Korea government confirmed to fund my project. It is the development of a composite sanding machine. I began development of this semi-robotic prototype beginning in 2009. It has possibilities of replacing or augmenting the exhaustive and difficult jobs performed by human hands, such as sanding, grinding, blasting, and polishing in most often, very awkward conditions, and is also will boost productivity, improve surface quality, cut abrasive costs, eliminate vibration injuries, and protect workers from exposure to dust and airborne contamination. Ease of control and operation of the equipment in or outside of the sanding room is a key benefit to end-users. It will prove to be much more economical than normal robotics and minimize errors that commonly occur in factories. The key components and their technologies are a 360 degree rotational shoulder and a wrist that is controlled under PLC controller and joystick manual mode. Development on both of the key modules is complete and are now operational. The Korean government fund boosted my development and I expect to complete full scale development no later than 3rd quarter 2012. Even with the advantages of composite materials, there is still the need to repair or to maintain composite products with a higher level of technology. I have learned many composite repair skills on composite airframe since many composite fabrication skills including repair, requires training for non aerospace applications. The wind energy market is now requiring much larger blades in order to generate more electrical energy for wind farms. One single blade is commonly 50 meters or longer now. When a wind blade becomes damaged from external forces, on-site repair is required on the columns even under strong wind and freezing temperature conditions. In order to correctly obtain polymerization, the repair must be performed on the damaged area within a very limited time. The use of pre-impregnated glass fabric and heating silicone pad and a hot bonder acting precise heating control are surely required.

Study on the Manufacturing Techniques of Metallic Ornament of Treasure 930, the Staffs of Yi Gyeong-seok (보물 제930호 이경석 지팡이에 사용된 장석의 제작기법 고찰)

  • Lee, Jae-sung;Jeon, Ik-hwan
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.309-318
    • /
    • 2015
  • The staff given with chair to Yi Gyeong-seok, senior official over 70 years old by King Hyeonjong of Joseon Dynasty is representative handcraft of Joseon Dynasty. Results of analysis on the metallic decoration show that the metallic ornament of the end part which is connected to the spade was made by rolling of iron plate and brass plating. The plated part is limited to the ornament of the end part connected to the spade and the plating was not applied to the spade. Brass including 20% zinc was used for the connecting part of guard while brass gilded iron was used for the spade. This suggests that the tone of the connecting part of the guard and the spade was not different for reason of visual harmonization. Potential applied plating method can be amalgam, dippping in molten brass, and brushing but the analysis result suggests that dipping in molten brass method is the most likely accepted method. The brass guard of knife was joined by tin-lead solder. Rivet used to fix the blade was made by pure iron as an optimum material which satisfies flexibility and strength.

Development of Drainage Pump for Rescue Sinking Ship (침수선박 구조를 위한 대용량 배수펌프 개발)

  • Kim, Kyeong-Soo;Jung, Kang-Hyun;Kim, Hae-Young;Kim, Nam-Hun;Cho, Je-Hyoung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.248-254
    • /
    • 2015
  • There has been no previous study on technology development of large capacity drainage pump for rescue sinking ship in the country. The agricultural drainage pump was widely used for rescue sinking ship but this pump has several problems such as efficiency, low displacement and malfunction in winter. Therefore, this paper proposes to solve the problems for swiftly rescue sinking ship and develops the drainage pump system that has $20m^3/min$ mass flow rate specification at suction head 8 m. The centrifugal pump type the most commonly used in the field of naval architecture and ocean engineering was selected and designed based on the requirement specification. The blade design of impeller was derived from the Stepanoff coefficient and requirement specification and used computational fluid dynamics to review the target mass flow rate according to the impeller RPM at design operating conditions. We also performed structure analysis of the impeller to find structurally vulnerable points for the pump in service and completed the theoretical design of drainage pump system.

Microstructures and Mechanical Properties of GTD 111DS Welds by $CO_2$ Laser Welding ($CO_2$ 레이저를 이용한 GTD111DS 초합금 용접부의 미세조직과 기계적 성질)

  • Lee, Tack-Woon;Yang, Sung-Ho;Kim, Sang-Hun
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.108-108
    • /
    • 2009
  • Precipitation hardening nickel base alloys strengthened by intermetallic compounds are extensively used to manufacture on the components of the hot section of gas turbine engines. To ensure structural stability and maintenance of strength properties for a long time, nickel alloys are normally subjected to complex alloying with elements to form ${\gamma}'$(gamma prime). Such alloys have a limited weldability, are normally welded in high temperature. However, laser welding have a merit that applies in room temperature as easy control of welding parameter and heat input. In this study, $CO_2$ laser welding is applied on STS304 plate with good ductility and precipitation hardening nickel base alloy (GTD111DS) used blade material. Also, several welding parameters are applied on powder, power and travel speed. There are no cracks in Rene 80 and IN 625 powder when STS304 plate is used. But IN 625 powder has no cracks and Rene 80 have some cracks in welds with GTD111DS substrate. Adjusting of welding parameter is tried to apply Rene 80 having a good strength compare to IN 625. In the result of adjusted welding parameter, optimized welding parameters are set with low power, low feed rate and high welding speed. Tensile strength of GTD111DS substrate with Rene 80 powder is same and over than the one of base metal in room temp and high temp($760^{\circ}C$).

  • PDF

Comparison of Optimum Drilling Conditions of Aircraft CFRP Composites using CVD Diamond and PCD Drills (CVD 다이아몬드 및 PCD이 드릴을 이용한 항공용 CFRP 복합재료의 홀 가공성 비교)

  • Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Park, Joung-Man
    • Composites Research
    • /
    • v.24 no.4
    • /
    • pp.23-28
    • /
    • 2011
  • Recently CFRP laminate joints process by bolts and nets are developed rapidly in aircraft industries. However, there are serious drawback during jointing process. Many hole processes are needed for the manufacturing and structural applications using composite materials. Generally, very durable polycrystalline crystalline diamond (PCD) drill has been used for the CFRP hole process. However, due to the expensive price and slow process speed, chemical vapor deposition (CVD) diamond drill has been used increasingly which are relatively-low durability but easily-adjustable process speed via drill shape change and price is much lower. In this study, the comparison of hole process between PCD and CVD diamond coated drills was done. First of all, CFRP hole processbility was evaluated using the equations of hole processing conditions (feed amount per blade, feed speed). The comparison on thermal damage occurring from the CFRP specimen was also studied during drilling process. Empirical equation was made from the temperature photo profile being taken during hole process by infrared thermal camera. In addition, hole processability was compared by checking hole inside condition upon chip exhausting state for two drills. Generally, although the PCD can exhibit better hole processability, hole processing speed of CVD diamond drill exhibited faster than PCD case.

Optimal effect-site concentration of remifentanil to prevent hemodynamic changes during nasotracheal intubation using a video laryngoscope

  • Yoon, Ji-Young;Park, Chul-Gue;Kim, Eun-Jung;Choi, Byung-Moon;Yoon, Ji-Uk;Kim, Yeon Ha;Lee, Moon Ok;Han, Ki Seob;Ahn, Ji-Hye
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.4
    • /
    • pp.195-202
    • /
    • 2020
  • Background: Nasotracheal intubation is the most commonly used method to secure the field of view when performing surgery on the oral cavity or neck. Like orotracheal intubation, nasotracheal intubation uses a laryngoscope. Hemodynamic change occurs due to the stimulation of the sympathetic nervous system. Recently, video laryngoscope with a camera attached to the end of the direct laryngoscope blade has been used to minimize this change. In this study, we investigated the optimal effect-site concentration (Ce) of remifentanil for minimizing hemodynamic responses during nasotracheal intubation with a video laryngoscope. Methods: Twenty-one patients, aged between 19 and 60 years old, scheduled for elective surgery were included in this study. Anesthesia was induced by slowly injecting propofol. At the same time, remifentanil infusion was initiated at 3.0 ng/ml via target-controlled infusion (TCI). When remifentanil attained the preset Ce, nasotracheal intubation was performed using a video laryngoscope. The patient's blood pressure and heart rate were checked pre-induction, right before and after intubation, and 1 min after intubation. Hemodynamic stability was defined as an increase in systolic blood pressure and heart rate by 20% before and after nasotracheal intubation. The response of each patient determined the Ce of remifentanil for the next patient at an interval of 0.3 ng/ml. Results: The Ce of remifentanil administered ranged from 2.4 to 3.6 ng/ml for the patients evaluated. The estimated optimal effective effect-site concentrations of remifentanil were 3.22 and 4.25 ng/ml, that were associated with a 50% and 95% probability of maintaining hemodynamic stability, respectively. Conclusion: Nasotracheal intubation using a video laryngoscope can be successfully performed in a hemodynamically stable state by using the optimal remifentanil effect-site concentration (Ce50, 3.22 ng/ml; Ce95, 4.25 ng/ml).

High Cycle Fatigue Life Evaluation of Damaged Composite Rotor Blades (손상된 복합재 로터 블레이드의 고주기 피로수명 평가)

  • Kee, Young-Jung;Kim, Seung-Ho;Han, Jeong-Ho;Jung, Jae-Kwon;Heo, Jang-Wook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.10
    • /
    • pp.1275-1282
    • /
    • 2012
  • Helicopter rotor systems are dynamically loaded structures with many composite components such as the main and the tail rotor blades. The fatigue properties of composite materials are extremely important to design durable and reliable helicopter rotor blades. The safe-life methodology has generally been used in the helicopter industry to substantiate dynamically loaded composite components. However, it cannot be used to evaluate the strength reducing effects of flaws and defects that may occur during manufacturing and operational usage. The damage tolerance methodology provides a proper means to overcome this shortcoming; however, it is difficult to economically apply it to every composite component. The flaw tolerant methodology is an equivalent option to the damage tolerance methodology for civil and military rotorcraft. In this study, the flaw tolerant safe-life evaluation is described and illustrated by means of successful application to substantiate the retirement time of composite rotor blades.