• Title/Summary/Keyword: Use of radiation

Search Result 2,035, Processing Time 0.028 seconds

Intent to Use a Smartphone Application for Radiation Monitoring in Correlation with Anxiety about Exposure to Radiation, Recognition of Risks, and Attitudes toward the Use of Radiation

  • Han, Eunkyoung;Rott, Carsten;Hong, Seung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.4
    • /
    • pp.205-211
    • /
    • 2017
  • Background: Radiation is used in a variety of areas, but it also poses potential risks. Although radiation is often used with great effectiveness in many applications, people perceive potential risks associated with radiation and feel anxious about the possibility of radiation exposure. Various methods of measuring radiation doses have been developed, but there is no way for the general public to measure their doses with ease. Currently, many people use smartphones, which provide information about the location of an individual phone through network connections. If a smartphone application could be developed for measuring radiation dosage, it would be a very effective way to measure individuals' radiation doses. Thus, we conducted a survey study to assess the social acceptance of such a technology by the general public and their intent to use that technology to measure radiation doses, as well as to investigate whether such an intention is correlated with anxiety and attitudes toward the use of radiation. Materials and Methods: A nationwide online survey was conducted among 355 Koreans who were 20 years old or older. Results and Discussion: Significant differences were found between the genders in attitudes, perceptions of radiation risk, and fears of exposure to radiation. However, a significant difference according to age was observed only in the intent to use a smartphone dose measurement application. Attitudes towards the use of radiation exerted a negative effect on radiation risk perception and exposure anxiety, whereas attitudes towards the use of radiation, risk perception, and anxiety about exposure were found to have a positive impact on the intent to use a smartphone application for dose measurements. Conclusion: A survey-based study was conducted to investigate how the general public perceives radiation and to examine the acceptability of a smartphone application as a personal dose monitoring device. If such an application is developed, it could be used not only to monitor an individual's dose, but also to contribute to radiation safety information infrastructure by mapping radiation in different areas, which could be utilized as a useful basis for radiation research.

An Investigation on The Necessity of the Use of Radiation and The Recognition of Radiation Hazard among College Students (방사선 이용의 필요성 및 인체장해에 대한 대학생의 인식조사)

  • Han, Eun-Ok;Moon, In-Ok
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.7
    • /
    • pp.51-58
    • /
    • 2006
  • Background & Objectives: This study investigates the recognition on the necessity of the use of radiation for both college students who are considered that they have a high knowledge level in radiation and proposes basic materials to change the recognition of the use of radiation. Also, the investigation was applied to average people who showed the most negative attitudes on radiation. Methods: A questionnaire was applied to 600 college students for five days from October 10 to 15, 2005 and used in statistical analysis. Results: The average value obtained in the recognition of the use of radiation was 76.60 points in which male respondents who were majored in natural science, health, and engineering department and respondents who have experienced radiation related education, radiation diagnosis, and radiation treatment demonstrated higher levels. Also, the average value obtained in the recognition of the radiation damage was 71.66 points in which respondents who were majored in natural sciences, humanities, engineering, and health department showed higher levels than that of respondents who were majored in art and physical department. Groups that exhibited higher recognition levels in the necessity of the use of radiation were male respondents and respondents who were majored in natural science, humanities, and health department and have experienced radiation diagnosis and radiation treatment. In the results of the correlation analysis on the necessity of the use of radiation and recognition of radiation damages, the recognition of radiation damages was presented as negative attitudes in the case of the higher recognition level in the necessity of the use of radiation. Conclusions: Regarding the frequency of the use of radiation in Korea, a 80.9% of university students who showed a high education level had no experiences in radiation related education. Although they showed a relatively high level of 76.6 points in the recognition level of the necessity of the use of radiation, the negative attitude on the radiation damage was also presented as a high level of 71.7 points. Because the providing chance of radiation related information was limited as compared to the atomic power used in Korea and dependancy of the use of radiation, it is necessary to provide the basic information related in the use of radiation to the public. In addition, various investigations on the use of radiation and such negative attitudes are required in future for the public. Also, the correct information of the radiation safety should be delivered to the public.

  • PDF

Radiation Safety and Education in the Applicants of the Final Test for the Expert of Pain Medicine

  • Park, Pyong-Eun;Park, Jung-Min;Kang, Joo-Eun;Cho, Jae-Hun;Cho, Suk-Ju;Kim, Jae-Hun;Sim, Woo-Seog;Kim, Yong-Chul
    • The Korean Journal of Pain
    • /
    • v.25 no.1
    • /
    • pp.16-21
    • /
    • 2012
  • Background: The C-arm fluoroscope is known as the most important equipment in pain interventions. This study was conducted to investigate the completion rate of education on radiation safety, the knowledge of radiation exposure, the use of radiation protection, and so on. Methods: Unsigned questionnaires were collected from the 27 pain physicians who applied for the final test to become an expert in pain medicine in 2011. The survey was composed of 12 questions about the position of the hospital, the kind of hospital, the use of C-arm fluoroscopy, radiation safety education, knowledge of annual permissible radiation dose, use of radiation protection, and efforts to reduce radiation exposure. Results: In this study, although most respondents (93%) had used C-arm fluoroscopy, only 33% of the physicians completed radiation safety education. Even though nine (33%) had received education on radiation safety, none of the physicians knew the annual permissible radiation dose. In comparing the radiation safety education group and the no-education group, the rate of wearing radiation-protective glasses or goggles and the use of radiation badges or dosimeters were significantly higher in the education group. However, in the use of other protective equipment, knowledge of radiation safety, and efforts to reduce radiation exposure, there were no statistical differences between the two groups. Conclusions: The respondents knew very little about radiation safety and had low interest in their radiation exposure. To make the use of fluoroscopy safer, additional education, as well as attention to and knowledge of practices of radiation safety are required for pain physicians.

The evaluation of usefulness for far-infrared radiating under inner-wear on dysmenorrhea (월경통(月經痛)에 대한 원적외선 방사 기능성 under inner-wear의 유용성 평가)

  • Cho, Jung-Hoon;Lee, Kyung-Sub;Yoon, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.20 no.3
    • /
    • pp.129-136
    • /
    • 2007
  • Purpose: We intended to observe the usefulness of far-infrared radiation functional under inner-wear for dysmenorrhea. Methods: We introduced far-infrared radiation functional under inner-wear to women in childbearing-age by internet portal site. Then, we preliminarily examined dysmenorrhea severity by VAS(visual analogue scale) questionnaire to women interested in far-infrared radiation functional under inner-wear. We selected women scored 5 and above of 10 measurement VAS score. Finally, 121 women were the subject of study and used far-infrared radiation functional under inner-wear for one menstrual cycle. Before and after use of far-infrared radiation functional under inner-wear, we conducted a questionnaire survey of dysmenorrhea severity by VAS. After that, we compared VAS score before and after use. Also, we studied correlation between frequency of far-infrared radiation functional under inner-wear use and ${\Delta}VAS$(VAS score before use minus VAS score after use). For statistics, we used Paired samples test and Spearman's rho correlations, SPSS 13.0 for windows. Results: Before and after use of far-infrared radiation functional under inner-wear, VAS score means were different. Frequency of far-infrared radiation functional under inner-wear use was correlated to ${\Delta}VAS$. Statistically they showed significant result (p<0.05>. Conclusion: The results showed that dysmenorrhea severity by VAS decreased after far-infrared radiation functional under inner-wear use. As frequency of use increased, ${\Delta}VAS$ increased. So we can consider far-infrared radiation functional under inner-wear effects dysmenorrhea severity.

  • PDF

Trends in intensity-modulated radiation therapy use for rectal cancer in the neoadjuvant setting: a National Cancer Database analysis

  • Wegner, Rodney E.;Abel, Stephen;White, Richard J.;Horne, Zachary D.;Hasan, Shaakir;Kirichenko, Alexander V.
    • Radiation Oncology Journal
    • /
    • v.36 no.4
    • /
    • pp.276-284
    • /
    • 2018
  • Purpose: Traditionally, three-dimensional conformal radiation therapy (3D-CRT) is used for neoadjuvant chemoradiation in locally advanced rectal cancer. Intensity-modulated radiation therapy (IMRT) was later developed for more conformal dose distribution, with the potential for reduced toxicity across many disease sites. We sought to use the National Cancer Database (NCDB) to examine trends and predictors for IMRT use in rectal cancer. Materials and Methods: We queried the NCDB from 2004 to 2015 for patients with rectal adenocarcinoma treated with neoadjuvant concurrent chemoradiation to standard doses followed by surgical resection. Odds ratios were used to determine predictors of IMRT use. Univariable and multivariable Cox regressions were used to determine potential predictors of overall survival (OS). Propensity matching was used to account for any indication bias. Results: Among 21,490 eligible patients, 3,131 were treated with IMRT. IMRT use increased from 1% in 2004 to 22% in 2014. Predictors for IMRT use included increased N stage, higher comorbidity score, more recent year, treatment at an academic facility, increased income, and higher educational level. On propensity-adjusted, multivariable analysis, male gender, increased distance to facility, higher comorbidity score, IMRT technique, government insurance, African-American race, and non-metro location were predictive of worse OS. Of note, the complete response rate at time of surgery was 28% with non-IMRT and 21% with IMRT. Conclusion: IMRT use has steadily increased in the treatment of rectal cancer, but still remains only a fraction of overall treatment technique, more often reserved for higher disease burden.

Review of Shielding Evaluation Methodology for Facilities Using kV Energy Radiation Generating Devices Based on the NCRP-49 Report

  • Na Hye Kwon;Hye Sung Park;Taehwan Kim;Sang Rok Kim;Kum Bae Kim;Jin Sung Kim;Sang Hyoun Choi;Dong Wook Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.53-62
    • /
    • 2022
  • In this study, we have investigated the shielding evaluation methodology for facilities using kV energy generators. We have collected and analysis of safety evaluation criteria and methodology for overseas facilities using radiation generators. And we investigated the current status of shielding evaluation of domestic industrial radiation generators. According to the statistical data from the Radiation Safety Information System, as of 2022, a total of 7,679 organizations are using radiation generating devices. Among them, 6,299 facilities use these devices for industrial purposes, which accounts for a considerable portion of radiation. The organizations that use these devices evaluate whether the exposure dose for workers and frequent visitors is suitable as per the limit regulated by the Nuclear Safety Act. Moreover, during this process, the safety shields are evaluated at the facilities that use the radiation generating devices. However, the facilities that use radiating devices having energy less than or equal to 6 MV for industrial purposes are still mostly evaluated and analyzed according to the National Council on Radiation Protection and Measurements 49 (NCRP 49) report published in 1976. We have investigated the technical standards of safety management, including the maximum permissible dose and parameters assessment criteria for facilities using radiation generating devices, based on the NCRP 49 and the American National Standards Institute/Health Physics Society N.43.3 reports, which are the representative reports related to radiation shielding management cases overseas.

The Increased Use of Radiation Requires Enhanced Activities Regarding Radiation Safety Control (방사성 물질 등의 이용 증가에 따른 안전 관리 문제점 고찰)

  • Lee, Yunjong;Lee, Jinwoo;Jeong, Gyo-Seong
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.103-109
    • /
    • 2015
  • More recently, companies that have obtained permission to use radioactive materials or radiation device and registered radiation workers have increased by 10% and 4% respectively. The increased use of radiation could have an effect on radiation safety control. However, there is not nearly enough manpower and budget compared to the number of workers and facilities. This paper will suggest a counteroffer thought analyzing pending issues. The results of this paper indicate that there are 47 and 31.3 workers per radiation protection officer in educational and research institutes, respectively. There are 20.1 persons per RPO in hospitals, even though there are 2 RPOs appointed. Those with a special license as a radioisotope handler were ruled out as possible managers because medical doctors who have a special license for radioisotope handling normally have no experience with radiation safety. The number of staff members and budget have been insufficient for safety control at most educational and research institutes. It is necessary to build an optimized safety control system for effective Radiation Safety Control. This will reduce the risk factor of safety, and a few RPOs can be supplied for efficiency and convenience.

Radiation safety for pain physicians: principles and recommendations

  • Park, Sewon;Kim, Minjung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • v.35 no.2
    • /
    • pp.129-139
    • /
    • 2022
  • C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.6
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

Recent trends in intensity-modulated radiation therapy use in Korea

  • Huh, Seung Jae;Park, Won;Choi, Do Ho
    • Radiation Oncology Journal
    • /
    • v.37 no.4
    • /
    • pp.249-253
    • /
    • 2019
  • Purpose: We aimed to analyze the trend in intensity-modulated radiation therapy (IMRT) use in Korea from 2011 to 2018. Materials and Methods: We collected data from the Health and Insurance Review and Assessment Service (HIRA) big data based on the National Health Insurance Service claims and reimbursements records using primary treatment planning codes (HD 041) for IMRT from 2011 to 2018. We analyzed the changing patterns in clinical application to specific tumor sites and regional differences in IMRT utilization. Results: The use of IMRT has exhibited an 18-fold steep rise from 1,921 patients in 2011 to 34,759 in 2018. With regard to IMRT in 2018, 70% of patients (24,248/34,759) were treated in metropolitan areas (Seoul, Incheon, and Gyeonggi Province). IMRT was most commonly used to treat breast, lung, and prostate cancers in 2018. Among these, the use of IMRT for breast cancer shows the most remarkable increase from 2016 when the National Health Insurance began to cover IMRT for all solid tumors. Conclusion: The use of IMRT is steadily increasing to treat cancer and is concentrated in metropolitan areas.