• Title/Summary/Keyword: Usability Measurement

Search Result 181, Processing Time 0.032 seconds

User Centered Interface Design of Web-based Attention Testing Tools: Inhibition of Return(IOR) and Graphic UI (웹 기반 주의력 검사의 사용자 인터페이스 설계: 회귀억제 과제와 그래픽 UI를 중심으로)

  • Kwahk, Ji-Eun;Kwak, Ho-Wan
    • Korean Journal of Cognitive Science
    • /
    • v.19 no.4
    • /
    • pp.331-367
    • /
    • 2008
  • This study aims to validate a web-based neuropsychological testing tool developed by Kwak(2007) and to suggest solutions to potential problems that can deteriorate its validity. When it targets a wider range of subjects, a web-based neuropsychological testing tool is challenged by high drop-out rates, lack of motivation, lack of interactivity with the experimenter, fear of computer, etc. As a possible solution to these threats, this study aims to redesign the user interface of a web-based attention testing tool through three phases of study. In Study 1, an extensive analysis of Kwak's(2007) attention testing tool was conducted to identify potential usability problems. The Heuristic Walkthrough(HW) method was used by three usability experts to review various design features. As a result, many problems were found throughout the tool. The findings concluded that the design of instructions, user information survey forms, task screen, results screen, etc. did not conform to the needs of users and their tasks. In Study 2, 11 guidelines for the design of web-based attention testing tools were established based on the findings from Study 1. The guidelines were used to optimize the design and organization of the tool so that it fits to the user and task needs. The resulting new design alternative was then implemented as a working prototype using the JAVA programming language. In Study 3, a comparative study was conducted to demonstrate the excellence of the new design of attention testing tool(named graphic style tool) over the existing design(named text style tool). A total of 60 subjects participated in user testing sessions where their error frequency, error patterns, and subjective satisfaction were measured through performance observation and questionnaires. Through the task performance measurement, a number of user errors in various types were observed in the existing text style tool. The questionnaire results were also in support of the new graphic style tool, users rated the new graphic style tool higher than the existing text style tool in terms of overall satisfaction, screen design, terms and system information, ease of learning, and system performance.

  • PDF

Usability assessment of thermoplastic Bolus for skin VMAT radiotherapy (피부 병변에 대한 VMAT 치료 시 열가소성 bolus의 유용성 평가: case review)

  • Kim, Min Soo;Kim, Joo Ho;Shin, Hyun Kyung;Cho, Min Seok;Park, Ga Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.85-92
    • /
    • 2020
  • Purpose: To find out the advantages of thermoplastic bolus compared to conventional bolus, which is mainly used in clinical practice, We evaluated Two cases in terms of dose and location reproducibility to assess Usability of thermoplastic Bolus for skin VMAT radiotherapy. Materials and Methods: Two patient's treated with left breast skin lesion were simulated using thermoplastic Bolus and planned with 2arc VMAT. the prescription dose was irradiated to 95% or more of the target volume. We evaluated The reproducibility of the bolus position by measuring the length of the air gap in the CBCT (Cone Beam CT) image. to evaluate dose reproducibility, we compared The dose distribution in the plan and CBCT and measured in vivo for patient 2. Results: The difference between the air gap in patient 1's simulation CT and the mean air gap (M1) during 10 treatments in the CBCT image was -0.42±1.24mm. In patient 2, the difference between the average air gap between the skin and the bolus (M2) during 14 treatments was -1.08±1.3mm, and the air gap between the bolus (M3) was 0.49±1.16. The difference in the dose distribution between Plan CT and CBCT was -1.38% for PTV1 D95 and 0.39% for SKIN (max) in patient 1. In patient 2, PTV1 D95 showed a difference of 0.63% and SKIN (max) -0.53%. The in vivo measurement showed a difference of -1.47% from the planned dose. Conclusion: thermoplastic Bolus is simpler and takes less time to manufacture compared to those produced by 3D printer. Also compared to conventional bolus, it has high reproducibility in the set-up side and stable results in terms of dose delivery.

Evaluation of Physical Properties of Liposome Essences as Customized Cosmetic Bases and Evaluation of Satisfaction According to Skin Type (맞춤형화장품 베이스로서 리포좀 에센스의 물성 평가 및 피부타입에 따른 만족도 평가)

  • An, Hyung Guen;Hyeon, Tong-Il;Yoon, Kyung-Sup
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.1
    • /
    • pp.1-10
    • /
    • 2022
  • Customized cosmetics are continuously mentioned as a trend in the cosmetics industry to respond to the recent rapid changes in the social environment and pursue individuality and diversity. Accordingly, four types of liposome essence corresponding to skin types were prepared by varying the ratio of liposome formulation and essence formulation as a customized cosmetic base that can be easily mixed and applied at the workplace. The volatilization residues of four types of liposome essence were measured and the nanoparticle size, polydispersity index, zeta potential and viscosity according to time for 90 d were measured, and Turbiscan was measured as a method for evaluating the stability of a colloidal dispersion system. In addition, a simple usability evaluation was performed for four types of liposome essence corresponding to the skin type. As a result, the amount of volatile residue in the four types of liposome essence was increased in dry products rather than oily ones, and the particle size showed a tendency to increase with time in the range of 165 to 175 nm, increasing up to 31.5%, and the polydispersity index was 0.23 to 0.26. There was little change with time, and the zeta potential was -74 to -72 mV, showing a slight decrease with time, but there was little change to the extent of a maximum decrease of 14.0%. Viscosity showed a decreasing trend with time in the range of 2,580 ~ 3,290 cps, showing a maximum decrease of 17.5%. In the turbiscan measurement, all of the turbiscan stability index, a measure of stability, were less than 1.0, indicating dispersion stability. In the overall simple usability satisfaction evaluation for skin types (6 points), products for oily skin (5.33 ± 0.75 points) > products for medium dry skin (5.13 ± 0.95 points) > products for dry skin (5.03 ± 0.96 points) > products for oily skin (4.80 ± 1.04 points) points) were evaluated in order. The four types of liposome essence corresponding to skin types with different ratios of liposome formulation and essence formulation were physically stable, and the possibility of application as a customized cosmetic base according to skin type was confirmed.

Evaluation of Physical Properties of Nanoemulsion Ampoule as Customized Cosmetic Bases and Evaluation of Satisfaction According to Skin Type (맞춤형화장품 베이스로서 나노에멀젼 앰플의 물성 평가 및 피부타입에 따른 만족도 평가)

  • Se-Yeon, Kim;Hyung Guen, An;Ja Young, Kim;Kyung-Sup, Yoon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.48 no.4
    • /
    • pp.343-355
    • /
    • 2022
  • Customized cosmetics are continuously mentioned as cosmetics in response to changes in the social environment and trends that emphasize individuality. Therefore, in this study, four types of nanoemulsion ampoules corresponding to skin types were prepared by different ratios of nanoemulsion formulation and ampoule formulation, and the applicability as a customized cosmetic base was checked. Particle size, polydispersity index, zeta potential, and viscosity according to time for 90 d were measured for four nanoemulsion ampoules with different volatile residues, and turbiscan was measured as a method for evaluating the stability of a colloidal dispersion system. Finally, human usability satisfaction was evaluated. As a result, it was confirmed that four kinds of nanoemulsion ampoules had a higher amount of volatile residue in the dry skin test product than in the oily skin test product. The pH was in the range of 6.41 to 6.88, and the particle size was in the range of 170 to 174 nm, and the change after 90 d was within 1.2% of the maximum, and there was no specificity in particle size stability. It was confirmed that the polydispersity index was almost constant, and showed a particle size distribution close to monodispersity by showing a change within a value smaller than 0.21 in all test products. The zeta potential was initially -63 mV or more for all four types of test products, and although it showed a slight decrease with time, there was little change to the extent of a maximum decrease of 2.5%. Viscosity was initially in the range of 4,100 to 5,100 cps and showed a decreasing trend with time, showing a maximum decrease of 37.7%. In the turbiscan measurement, the turbiscan stability index, a measure of stability, was all below 1.0, indicating dispersion stability. In the usability satisfaction evaluation (6 points) of 4 nanoemulsion ampoules corresponding to skin type, oily skin product (5.42 ± 0.67 points) > neutral oily skin product (5.36 ± 0.67 points) > neutral dry skin product (5.15 ± 0.69 point) > dry skin product (4.75 ± 0.75 points) in the order of evaluation. Four types of nanoemulsion ampoules are physically stable and have confirmed their applicability as a customized cosmetic base according to skin type, and are expected to expand in various ways.

A Study on the Use of Scientific Investigation Equipment to Support Decision-making of the Resident Evacuation in the Event of a Chemical Accident (화학사고 발생에 따른 주민대피 의사결정 지원을 위한 과학조사장비 활용방안 연구)

  • Oh, Joo-Yeon;Lee, Tae Wook;Cho, Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_3
    • /
    • pp.1817-1826
    • /
    • 2022
  • After the hydrogen fluoride leak in Gumi in 2012, the government has been systemizing the disaster management system, such as responding to and managing chemical accidents. In particular, the Ministry of the Interior and Safety (MOIS) is in charge of evacuation of residents following chemical accidents based on the Framework Act on Management of Disaster and Safety. In this study, an application plan was presented to support and utilize the decision-making support for evacuation of residents after a chemical accident using the chemical accident investigation equipment of the National Disaster Management Research Institute (NDMI). In the equipment operation system for scientific information collection due to chemical accidents, the roles and purpose of use of long/short distance measurement equipment were presented according to regular and emergency situations. Using the data acquired through long/short distance measurement equipment, it can be used as basic data for resident evacuation decision-making by monitoring whether chemicals are detected in an emergency and managing data on detected substances by company in a regular situation. As a result of measuring chemical substances in order to verify on-site usability by equipment only for the regular operation system, it was confirmed that real-time detection of chemical substances is possible with long distance measuring equipment. In addition, it was confirmed that it was necessary to check the measurable distance and range of the equipment in the future. In the case of short distance measurement equipment, hydrocarbon-based substances were mainly detected, and it was confirmed that it was measured at a higher level in Ulsan-Mipo National Industrial Complex than in Onsan National Industrial Complex. It is expected that it can be used as basic data to support decision-making in the event of chemical accidents through continuous data construction in the future.

An Evaluation Model of Information Quality of UCC Service Site (UCC 서비스 사이트의 정보품질 평가 모델 개발)

  • Kang, So-Ra;Kim, Yoo-Jung;Lee, Hyun-Ju;Moon, Yoon-Ji;Kim, Woo-Dy
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.8
    • /
    • pp.2818-2826
    • /
    • 2010
  • This research was conducted to develop a model appropriate for the measurement of information quality of UCC service site. The evaluation factors that reflect more improvement of the information utilization capability were verified. Enhancement of information utilization capability can control greater amount of information among the users and site companies, and among users. Therefore, Wikipedia, for example, provides a Web 2.0 based information quality that is more advanced than Web 1.0 by allowing effective control of information among the users. This type of information quality presents 'information reliability' and 'information stability' as evaluation factors added to the factors such as 'information sufficiency' and 'information usability.' Information reliability and information stability are essential factors that need to conduct an evaluation in the Web 2.0 environment that can distribute greater number of information in the environment where all the users serve as participants. Moreover, 'interesting information' and 'originality of information' suggests that information itself should include the attributes that can attract the attention of users, due to the nature of the Attention Economics, which points out one of the Web 2.0 phenomenon that the number of information consumers is smaller than that of information suppliers.

Effect of Drying Time and Additives regarding the Physical Properties of Vegetable Fatty Acid Soap (식물성 지방산 비누의 물리적 특성에 대한 건조시간과 첨가물의 효과)

  • Lee, Sung-Hee;Lee, Ki-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.4032-4038
    • /
    • 2014
  • Vegetable fatty acid solid soap requires a drying process for moisture evaporation and hardness after being manufactured through saponification. Although the soap is manufactured by mixing additives mainly from natural ingredients, existing studies have focused primarily on the usability of vegetable solid soap. Consequently, research into the physical properties of vegetable fatty acid solid soap mixed with natural ingredients has been unsatisfactory. Therefore, this study attempted to compare and observe the changes in the physical properties (pH, surface tension, critical micelle concentration, and cleansing power) of solid soap in accordance with the drying period and additives (tea tree E.O and $TiO_2$) using pH paper, the Du Nouy measurement method, sedimentation method, and ultrasound washer. Regardless of the mixture with additives, vegetable fatty acid solid soap showed the same pH, and there was no change in the pH while maintaining pH 8 beginning from the $2^{nd}$ weeks to $12^{th}$ weeks of drying. In addition, as a result of measuring the surface tension and CMC, regardless of the drying period, only the soap added with $TiO_2$ showed an even value of 62.5mg/L, whereas the other soap specimens showed a decline in CMC to 25mg/L on the fourth week of drying. As a result of measuring the detergency, the removal efficiency of vegetable fatty acid solid soap mixed with tea tree E.O and $TiO_2$ and dried for four weeks was 4.50~4.65%, which was higher than that of the vegetable fatty acid solid soap without additives (3.62~3.92%).

A Study on The Evaluation for Quality Factors of SNS and SNS Media by Using AHP (AHP 기법을 적용한 SNS 품질요인 및 SNS 매체 평가에 관한 연구)

  • Li, Nan;Park, Deuk
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.12
    • /
    • pp.299-307
    • /
    • 2014
  • Nowadays, SNS media has become one of the most common and economic communication methods in the modern word. With the rapid development of communication technology, a variety of SNS media makes easier for us to reach other people everywhere and people are getting more and more reliant on them. The surge in SNS media users and SNS media diversity gets more important every day, but academic research on SNS media evaluation program is scanty. In order to present an evaluation program on the SNS media, this study selected some applicable measurement factors based on reference research, and then evaluate major SNS medias by using AHP analysis method. With these purposes, Kakaotalk, Twitter and Facebook, are the three major SNS medias that were chosen for the analysis. Through collections and analysis of usability evaluation factors about SNS quality from related literature, some factors were concluded: system quality, information quality, interface quality and service quality, to build an AHP frame. And to achieve these purposes, this study applied comprehend mutual questionnaire survey for experts and users to gather research date. Empirical studies about the results were performed using AHP method with Microsoft Office Excel 2010. In this study, the final SNS media evaluation result is that Kakaotalk ranks first of the three SNS media, Facebook is in the second place, and Twitter as least. When SNS media are evaluated, system quality, information quality, interface quality and service quality should be considered. Among all factors, service quality is the most important.

Attack Detection in Recommender Systems Using a Rating Stream Trend Analysis (평가 스트림 추세 분석을 이용한 추천 시스템의 공격 탐지)

  • Kim, Yong-Uk;Kim, Jun-Tae
    • Journal of Internet Computing and Services
    • /
    • v.12 no.2
    • /
    • pp.85-101
    • /
    • 2011
  • The recommender system analyzes users' preference and predicts the users' preference to items in order to recommend various items such as book, movie and music for the users. The collaborative filtering method is used most widely in the recommender system. The method uses rating information of similar users when recommending items for the target users. Performance of the collaborative filtering-based recommendation is lowered when attacker maliciously manipulates the rating information on items. This kind of malicious act on a recommender system is called 'Recommendation Attack'. When the evaluation data that are in continuous change are analyzed in the perspective of data stream, it is possible to predict attack on the recommender system. In this paper, we will suggest the method to detect attack on the recommender system by using the stream trend of the item evaluation in the collaborative filtering-based recommender system. Since the information on item evaluation included in the evaluation data tends to change frequently according to passage of time, the measurement of changes in item evaluation in a fixed period of time can enable detection of attack on the recommender system. The method suggested in this paper is to compare the evaluation stream that is entered continuously with the normal stream trend in the test cycle for attack detection with a view to detecting the abnormal stream trend. The proposed method can enhance operability of the recommender system and re-usability of the evaluation data. The effectiveness of the method was verified in various experiments.

Evaluation for Ultimate Flexural Strength of Steel Composite Girder with High Strength Concrete (고강도 콘크리트 강합성 거더의 극한휨강도 실험 평가)

  • Kim, Woon Hak;Lee, Juwon;Lee, Seokmin
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.796-805
    • /
    • 2020
  • Purpose: A static loading test was performed to evaluate the ultimate flexural strength of a girder in which 80MPa high-strength concrete was synthesized on the compressive flange of the I-shape steel girder. Method: This test is designed and fabricated two types of specimens with different shear-connection specifications, and evaluated their ultimate flexural behavior until reaching the extreme event limit states. In addition, the ultimate strength was evaluated by comparing the test results and the results of the strain compatibility method. Result: By confirming the displacement within 0.02mm as a result of the relative slip measurement, it was verified that the two specimens secured perfect bonding. Therefore, the difference in the shear specification does not have a great effect on the stiffness, and if the specimens are completely synthesized, there is no difference in the behavior until it reaches the extreme-event limit states. Conclusion: The girder to be tested has a working load within the elastic range and meets the usability requirements for allowable deflection. Therefore, even if a part of the casing is subjected to the tensile force at the level of cracking, the deck will first reach the compression failure due to the role of the reinforcing bar.