• Title/Summary/Keyword: Urine dipstick

Search Result 19, Processing Time 0.022 seconds

Urinalysis: The Usefulness and Limitations of Urine Dipstick Testing (요검사: 요시험지봉 검사의 유용성과 한계)

  • Han, Tae Hee
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.42-48
    • /
    • 2013
  • The urinalysis is an essential part of the diagnostic work-up for kidney disease and other renal system disorders. The dipstick test allows rapid and simultaneous chemical analyses of urine, including factors such as pH, specific gravity, protein, glucose, ketones, occult blood, bilirubin, urobilinogen, nitrite, and leukocyte-esterase. The chemical reactions on dipstick are complicated and can be affected by oxidizing, reducing, and discoloring substances in the urine. Therefore, false positive and false negative results are common in dipstick testing. To obtain reliable results with the dipstick, it is necessary to collect urine cleanly and examine the urine carefully. It is mandatory to clearly understand the principles of dipstick testing to evaluate abnormal findings. If the urine dipstick results suggest hematuria, proteinuria, or urinary tract infection, microscopy of the urine should be performed to confirm the findings.

Monoclonal Antibody-Based Dipstick Assay: A Reliable Field Applicable Technique for Diagnosis of Schistosoma mansoni Infection Using Human Serum and Urine Samples

  • Demerdash, Zeinab;Mohamed, Salwa;Hendawy, Mohamed;Rabia, Ibrahim;Attia, Mohy;Shaker, Zeinab;Diab, Tarek M.
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.1
    • /
    • pp.93-98
    • /
    • 2013
  • A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

Comparison of three types of analyzers for urine protein-to-creatinine ratios in dogs

  • Ji, Sumin;Yang, Yeseul;Jeong, Yeji;Hwang, Sung-Hyun;Kim, Myung-Chul;Kim, Yongbaek
    • Journal of Veterinary Science
    • /
    • v.22 no.1
    • /
    • pp.14.1-14.11
    • /
    • 2021
  • Background: Quantitation of urine protein is important in dogs with chronic kidney disease. Various analyzers are used to measure urine protein-to-creatinine ratios (UPCR). Objectives: This study aimed to compare the UPCR obtained by three types of analyzers (automated wet chemistry analyzer, in-house dry chemistry analyzer, and dipstick reading device) and investigate whether the differences could affect clinical decision process. Methods: Urine samples were collected from 115 dogs. UPCR values were obtained using three analyzers. Bland-Altman and Passing Bablok tests were used to analyze agreement between the UPCR values. Urine samples were classified as normal or proteinuria based on the UPCR values obtained by each analyzer and concordance in the classification evaluated with Cohen's kappa coefficient. Results: Passing and Bablok regression showed that there were proportional as well as constant difference between UPCR values obtained by a dipstick reading device and those obtained by the other analyzers. The concordance in the classification of proteinuria was very high (κ = 0.82) between the automated wet chemistry analyzer and in-house dry chemistry analyzer, while the dipstick reading device showed moderate concordance with the automated wet chemistry analyzer (κ = 0.52) and in-house dry chemistry analyzer (κ = 0.53). Conclusions: Although the urine dipstick test is simple and a widely used point-of-care test, our results indicate that UPCR values obtained by the dipstick test are not appropriate for clinical use. Inter-instrumental variability may affect clinical decision process based on UPCR values and should be emphasized in veterinary practice.

Classification of UTI Using RBF and LVQ Artificial Neural Network in Urine Dipstick Screening Test (RBF와 LVQ 인공신경망을 이용한 요(尿) 딥스틱 선별검사에서의 요로감염 분류)

  • Min, Kyoung-Kee;Kang, Myung-Seo;Shin, Ki-Young;Lee, Sang-Sik;Hun, Joung-Hwan
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.340-347
    • /
    • 2008
  • Dipstick urinalysis is used as a routine test for a screening test of UTI (urinary tract infection) in primary practice because urine dipstick test is simple. The result of dipstick urinalysis brings medical professionals to make a microscopic examination and urine culture for exact UTI diagnosis, therefore it is emphasized on a role of screening test. The objective of this study was to the classification between UTI patients and normal subjects using hybrid neural network classifier with enhanced clustering performance in urine dipstick screening test. In order to propose a classifier, we made a hybrid neural network which combines with RBF layer, summation & normalization layer and L VQ artificial neural network layer. For the demonstration of proposed hybrid neural network, we compared proposed classifier with various artificial neural networks such as back-propagation, RBFNN and PNN method. As a result, classification performance of proposed classifier was able to classify 95.81% of the normal subjects and 83.87% of the UTI patients, total average 90.72% according to validation dataset. The proposed classifier confirms better performance than other classifiers. Therefore the application of such a proposed classifier expect to utilize telemedicine to classify between UTI patients and normal subjects in the future.

The Clinical Use of Routine Urinalysis (기본 요분석검사의 임상적 이용)

  • Lee, Seung Joo
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.35-41
    • /
    • 2013
  • Routine urinalysis is a simple, economical, and useful test that facilitates the detection of urinary system diseases and monitoring of renal disease progression. It consists of 4 parts of specimen evaluation, gross examination, a dipstick urinalysis, and a sediment microscopic urinalysis. Urine specimens should first be evaluated in terms of acceptability, and thereafter, the gross appearance is examined for color, turbidity, and odor. In particular, a dipstick urinalysis is an easy and rapid test that provides information on the multiple physicochemical properties of the urine sample. Moreover, although a sediment microscopic urinalysis is time-consuming, it provides information on the cells, microorganisms, casts, and crystals. In the present report, the clinical significance of the routine urinalysis and the problems concerning interpretation are summarized.

Effect of Illuminance on Color-based Analysis of Diabetes-Related Urine Fusion Analytes on Dipstick Using a Smartphone Camera (스마트폰 카메라를 활용한 뇨시험지 당뇨병관련 융합 분석인자의 색기반 분석에 미치는 외부 조도 영향)

  • Kim, Na-Kyung;Cho, Young-Sik;Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.5
    • /
    • pp.93-99
    • /
    • 2021
  • Recently, the miniaturization and digitalization for the inspection devices of point-of-care testing (POCT) are rapidly evolving. In the urine test, a lot of researches on index paper technology are being conducted because people can be self-diagnosed through visual color comparison using a urine test paper, Dipsick. The purpose of this study is to analyze the RGB values from the color changes on Dipstick Pad, which isused for urine test, using a smartphone camera. To this end, the primary, analytes in urine wasdiabetes-related parameters such as glucose, ketone body and pH, which is the most frequently tested elements, and we pursuited to quantify the changes in dipstick color caused from artificial urine containing different ranges of sugar, ketone body, and pH. In this experiment, changes in RGB values under bright and dark illuminances were compared, and changes in RGB value were monitored as a function of concentration of analytes under the ambient illumination of laboratory. As a result, color separation at the bright luminance region was good, but it did not appearat the low luminance region, and the changed profiles in RGB value under different illuminances was suggested to correct the problem of the color separation algorithm.

Measurement of urinary protein in children

  • Myung Hyun Cho
    • Childhood Kidney Diseases
    • /
    • v.26 no.2
    • /
    • pp.69-73
    • /
    • 2022
  • Proteinuria is an early hallmark of kidney disease and a major risk factor for systemic cardiovascular diseases. There are several methods to measure proteinuria, such as the urine dipstick test, 24-hour urinary protein excretion method, and spot urine for the protein-to-creatinine ratio. The urine dipstick test is simple but inaccurate. The 24-hour urinary protein excretion method is the gold standard; however, it is cumbersome, especially in children. Spot urine for the protein-to-creatinine ratio is simple and accurate, but has limitations. Specific urinary protein such as albumin can be measured instead of the total protein content. Tests should be avoided in situations that cause transient proteinuria or false-positive results. It should be performed correctly, and its limitations should be recognized and interpreted accurately.

Urinalysis and Imaging Studies in Children with Urinary Tract Infection (소아 요로감염증으로 진단된 환아에서 요분석 검사와 신영상 검사)

  • Kim Il-Kyung;Seong Ho;Choi Chang-Hee;Kim Kyong-Il
    • Childhood Kidney Diseases
    • /
    • v.3 no.2
    • /
    • pp.117-122
    • /
    • 1999
  • Purpose : We studied the correlation between urinalysis and radiologic findings in infants and children with urinary tract infection. Method : Urine Dipstick test and unstained urine microscopic examination were carried out in 56 infants and children who were hospitallized with the diagnosis of urinary infection by pocitive urine culture at Seoul Adventist from September 1996 through August 1998. Urine was collected by midsream, catheter, urine bag after cleansing or bladder puncture. Renal sonography and $^{99m}Tc-DMSA$ renal scan or voiding cystoureterography were studied. Results : 1)In dipstick analysis, leukocyte esterase(LE) were positive in 30 cases of 56 patients(54%) and Nitrite were positive in 20 cases of 56 patients(36%) and LE or Nitrite were positive in 38 cases of 56 children with UTI(68%). 2)In microscopic analysis, WBC were positive in 38 cases of patients(68%) and bacteria were positive in 23 cases of 56 patients(41%) and WBC or bacteria were positive in 41 cases of 56 children with UTI(71%). 3)Ten cases of 56 UTI patients(18%) showed negative finding in Dipstick and microscopic analysis. 4)There was no significant difference in positive rate of dipstick(71% vs 66%) and microscopia analysis(83% vs 66%) between two group with or without renal scar on $^{99m}Tc-DMSA$ scan (P=0.117). 5)There was no significnt difference in positive rate of dipstick(100% vs 91%) and microscopic analysis(100% vs 100%) between two groups with or without vesicoureteral reflux on VCUG. Conclusion : There was no specific relationships between the abnormal urinalysis and the abnormal findings on $^{99m}Tc-DMSA$ scan or VCUG.

  • PDF

Diagnostic Value of Dipstick Urinalysis (Leukocyte Esterase and Nitrite) as a Screening Test for Urinary Tract Infection in Acute Febrile Children (급성 발열 환아에서 요로감염 선별검사로서 Dipstick 요분석(Leukocyte esterase와 Nitrite)의 진단적 가치)

  • Hwang Soo-Ja;Park So-Young;Kim Hye-Soon;Park Eun-Ae;Kim Ho-Sung;Seo Jung-Wan;Lee Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1998
  • Purpose : To evaluate the diagnostic value of dipstick urinalysis($Multistix^{(R)}$) as a screening test for urinary tract infection(UTI) in acute febrile children. Methods : We compared dipstick uinalysis (leukocyte estease(LE) and nitrite) with microscopic urinalysis (WBC and bacteria) and urine culture in 80 children with UTI and 605 children without UTI, who were admitted due to acute fever at EWHA Womans University Hospital between Oct. 1994 and Feb. 1996. Results : 1) In dipstick urinalysis, LE and nitrite were positive in 38.7%, and 13.8% of 80 children with UTI and in 2.1%. and 1.2% of 605 children without UTI. 2) In microscopic urinalysis, WBC and bacteria were positive in 31.2%, and 17.5% of 80 children with UTI and in 4.1%, and 0.6% of 605 children without UTI. 3) Positive rate of LE on dipstick urinalysis was 38.7%, which was significantly higher than 31.5% of WBC on microscopic urinalysis (P<0.05). Positive rate of nitrite was not significantly different to that of bacteria. 4) Sensitivity, specificity, positive predictive value, negative predictive value of dipstick urinalysis were 43.7%, 98.3%, 63.6%, 92.9% which were not significant different to 40.0%, 99.0%, 54.0%, 92.3% of microscopic urinalysis. The sensitivity of combined dipstick and microscopic urinalysis were still low(50%). 5) Additional positive rate of microscopic urinalysis to negative dipstick urinalysis was 6.3%(5/80) in 80 children with UTI. Conclusion : The sensitivity of dipstick urinalysis was low and additional value of microscopic urinalysis was minimal in febrile UTI. So urine culture is mandatory in acute febrile children even though dipstick and microscopic urinalysis are negative.

  • PDF

Dipstick Urine Protein, as a Predictor of Cardiovascular Mortality in Korean Men: Korea Medical Insurance Corporation Study (심혈관 사망 예측인자로써의 반정량적 단백뇨 검사: KMIC 연구)

  • Ha, Kyoung-Soo;Kim, Hyeon-Chang;Kang, Dae-Ryong;Nam, Chung-Mo;Ahn, Song-Vogue;Suh, Il
    • Journal of Preventive Medicine and Public Health
    • /
    • v.39 no.5
    • /
    • pp.427-432
    • /
    • 2006
  • Objectives: This study was to investigate if the dipstick proteinuria can predict cardiovascular mortality in a population of Korean men. Methods: We measured urine protein and other cardiovascular risk factors in 100059 Korean men, aged between 35-59 years in 1990 and 1992. Levels of proteinuria measured by dipstick method were trace or less, 1+, 2+, and 3+ or greater. The primary outcomes were deaths from all causes, cardiovascular disease, cancer, and others in a 12 year follow-up from 1993 to 2004. Results: The multivariate-adjusted relative risks (95% CI) for cardiovascular death according to the level of proteinuria (1+, 2+, 3+ and more) in 1990 examination were 2.18 (1.36-3.48), 2.55 (1.37-4.78), and 4.57 (2.16-9.66) respectively. The corresponding relative risks according to the level of proteinuria in 1992 examination were 2.49 (1.71-3.64), 2.64 (1.53-4.58), and 2.78 (1.15-6.73). The relative risks for cardiovascular death of men with proteinuria (1+ or greater) once and twice among the examinations were 2.18 (1.63-2.92) and 3.75 (2.27-6.18), compared with men without proteinuria in 1990 and 1992 examinations. Conclusions: Our results showed that dipstick proteinuria is associated with cardiovascular mortality in Korean men. Dipstick proteinuria could be a predictor for cardiovascular mortality.