• Title/Summary/Keyword: Urinary bladder pressure

Search Result 23, Processing Time 0.028 seconds

A Non-Invasive Ultrasonic Urinary Bladder Internal Pressure Monitoring Technique: Its Theoretical Foundation and Feasibility Test (비침습적 초음파 방광 내압 측정 기술: 이론적 기초 및 실현 가능성 평가)

  • Choi, Min Joo;Kang, Gwan Suk;Lee, Kang Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.5
    • /
    • pp.526-539
    • /
    • 2012
  • A new approach was proposed in this article, named, a non-invasive ultrasonic method to monitor the urinary bladder internal pressure which can resolve the shortcomings of the existing methods. The proposed method makes use of acoustic cavitation. It is based on a physical phenomenon that an extracorporeal high intensity focused ultrasonic pulse generates bubbles inside the urinary bladder and the dynamic properties of the bubbles are related to the urinary bladder internal pressure. The article presents the theoretical foundation for the proposed technique and verifies its feasibility with preliminary experimental data. The suggested ultrasonic urinary bladder internal pressure monitoring method is non-invasive and can be used any time regardless of sex and age, so that it will be of a great benefit to the diagnosis and therapy of urination related diseases.

Urinary bladder rupture during voiding cystourethrography

  • Lee, Kyong-Ok;Park, Se-Jin;Shin, Jae-Il;Lee, Suk-Young;Kim, Kee-Hyuck
    • Clinical and Experimental Pediatrics
    • /
    • v.55 no.5
    • /
    • pp.181-184
    • /
    • 2012
  • Voiding cystourethrography (VCUG) is a commonly performed diagnostic procedure for the evaluation of vesicoureteral reflux with urinary tract infection or congenital renal diseases in children. The procedure is relatively simple and cost-effective, and complications are very rare. The iatrogenic complication of VCUG range from discomfort, urinary tract infection to bacteremia, as well as bladder rupture. Bladder rupture is a rare complication of VCUG, and only a few cases were reported. Bladder rupture among healthy children during VCUG is an especially uncommon event. Bladder rupture associated with VCUG is usually more common in chronically unused bladders like chronic renal failure. Presented is a case of bladder rupture that occurred during a VCUG in a healthy 9-month-old infant, due to instilled action of dye by high pressure. This injury completely healed after 7 days of operation, and it was confirmed with a postoperative cystography. The patient's bladder volume, underlying disease, velocity of the contrast media instilled, catheter size, and styles of instillation are important factors to prevent bladder rupture during VCUG. Management of bladder rupture should be individualized, but the majority of infants are treated with the operation. In conclusion, bladder rupture is a rare complication, however, delicate attention is needed in order to prevent more dire situations.

The Effects of Sa-am Acupuncture on Radial Pulse in Healthy Human Subjects: A Comparative Study on Tonifications of Kidney and Urinary Bladder (신정격 및 방광정격 자침이 정상 성인의 맥파 변화에 대한 비교 연구)

  • Kwak, Kyu In;Kang, Jae Hui;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.32 no.2
    • /
    • pp.105-121
    • /
    • 2015
  • Objectives : The purpose of this study is to observe the effects of Sa-am acupuncture with tonifications of kidney and urinary bladder on radial pulse in healthy subjects. Methods : Sixty healthy subjects participated in this study, and were divided into a kidney tonifying acupuncture group(KI group), urinary bladder tonifying acupuncture group(BL group) and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, immediately after, 30 minutes after, and 60 minutes after acupuncture at Cun, Guan, and Chi in each time. Results : 1. BL group exhibited significantly reduced T1 / T, T4 / T, T4 / (T-T4), T5 / T and increased(T-T4) / T compared to KI group. 2. BL group showed increase of radial augmentation index / heart rate(RAI / HR) in left Cun, H5, Ad / Ap in left Chi, H1, As / Ap in right Chi compared to KI group. BL group showed decrease of As / Ap, Aw / Ap in left Chi, H1, pulse depth, Ad / Ap in right Chi compared to KI group. 3. KI group showed increase of Aw / Ap, H1, H2, H4, pulse area in right Guan, pulse depth in right Chi compared to BL group. KI group showed decrease of RAI in left Cun, applied pressure, pulse depth in left Guan, Aw / Ap in right Chi compared to BL group. Conclusions : The effects of Sa-am acupuncture with tonifications of kidney and urinary bladder in healthy humans have been observed on various parameters. The parameters analysed in this study can be used to differentiate the effects of Sa-am acupuncture with tonifications of kidney and urinary bladder on radial pulse.

Study for portable bladder function monitoring system (휴대용 방광기능 검사 장치에 대한 연구)

  • Kim, K.S.;Lee, S.O.;Lee, G.S.;Lee, T.H.;Kim, G.H.;Kim, H.J.;Jang, C.H.;Yoon, S.I.;Kim, C.H.;Chae, H.C.;Song, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.379-381
    • /
    • 2005
  • Urodynamics describes a collection of tests designed to evaluate lower urinary tract function and can be performed using retrograde filling of the bladder within a room. In this study, we designed and calibrated the potable urodynamics monitoring system using DSP chip (TMS320VC33, Texas InstrumentTM, U.S.) and obtained signals of bladder(Pves) and bladder neck pressure(Pneck) and EMG using calibration kit (DPT9022K0122, MedtronicsTM, U.s,). This system monitor spontaneous urination during daily life and can make patients more comportable.

  • PDF

Sacral Block with Phenol in Hyperreflexic Bladder Patient (과반사성 방광 환자에서 페놀에 의한 천골신경 차단)

  • Lee, Won-Hyung;Shin, Hyo-Cheul;Yoon, Kun-Joong
    • The Korean Journal of Pain
    • /
    • v.8 no.2
    • /
    • pp.357-362
    • /
    • 1995
  • Percutaneous/intrathecal chemical neurolysis of sacral nerve with 12% phenol was performed on 13 cases of hyperreflexic bladder to augment bladder capacity and to reduce bladder pressure. Urodynamic evaluations were done before and after chemical neurolysis. Mean bladder capacity increased significantly after chemical neurolysis (from 171.4 ml to 375 ml). No significant changes in bowel or injection sites were noted. The result suggests that the chemolysis of sacral nerve was available modality for hyperreflexic bladder patients, who did not respond to anticholinergic medication, before decide the more aggressive alternatives such as augmentation cystoplasty or urinary diversion.

  • PDF

Design of ambulatory urodynamics monitoring system (휴대용 하부요로기능 검사 장치의 설계)

  • Lee, S.O.;Kim, K.S.;Yoon, D.Y.;Seo, J.H.;Song, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.48-50
    • /
    • 2005
  • Urodynamics describes a collection of tests designed to evaluate lower urinary tract function and can be performed using retrograde filling of the bladder within a room. In this study, we designed and calibrated the potable urodynamics monitoring system using DSP chip (TMS320VC33, Texas Instrument$^{TM}$, U.S.) and collected pressure and EMG using calibration kit (DPT9022K0122, Medtronics$^{TM}$, U.S.). This system can make patients more comportable and monitor spontaneous urination during daily life.

  • PDF

Predictors of outcomes after the trans-obturator tape procedure in females with equal severity for stress and urge mixed urinary incontinence

  • Young-Joo Kim
    • Journal of Medicine and Life Science
    • /
    • v.20 no.4
    • /
    • pp.166-171
    • /
    • 2023
  • Mixed urinary incontinence (UI) is common in women. This study aimed to assess the efficacy of anti-incontinence surgery in female patients with equally severe stress UI (SUI) and urge UI (UUI). All patients had equal severity of SUI and UUI. The postoperative cure rate was categorized into the cure group (CG) and failure group (FG). Postoperative satisfaction was categorized into the satisfaction group (SG) and the dissatisfaction group (DG). Statistical significance was set at P<0.05. Ninety patients (SG, 73.3%; DG, 26.7%; CG, 93.3%; FG, 6.7%) were included in the study. In the univariate analysis, body mass index (BMI), total bladder capacity, and overactive bladder symptom score (OABSS) were significantly different between the SG and DG groups. Peak urinary flow, Valsalva leak point pressure (VLPP), and OABSS were significantly different between the CG and FG groups. In the multivariate analysis, OABSS (P=0.001) and BMI (P=0.032) were independent predictors of postoperative satisfaction. VLPP (P=0.023) was the only independent factor associated with the postoperative cure rate. In equal severity of SUI and UUI, VLPP was found to be the only independent factor associated with postoperative cure rates. Higher VLPP values were associated with higher cure rates. BMI and OABSS were identified as independent predictors of postoperative satisfaction, with lower BMI and OABSS associated with higher postoperative satisfaction.

Implementation and Evaluation of the LUTS Diagnosis System Using FPGA (FPGA를 이용한 LUTS 진단 시스템 구현 및 평가)

  • Jeong, Do-Un;Chung, Wan-Young;Jeon, Gye-Rock
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.1
    • /
    • pp.6-14
    • /
    • 2007
  • The purpose of urodynamic investigation is to determine information on the function of the urinary system. One of the most frequently used measurement procedures in urodynamics is filling and voiding cystometry using invasive method. But in this method transurethral catheter is use and it makes patients uncomfortable. The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfortable method. Therefor in this study, a sensor and measuring system were implemented to measure uroflow, urophonography and noninvasive bladder pressure signal during urination for diagnosing the LUTS(lower urinary tract symptoms) using noninvasive method. The implemented system compose of the sensor parts, signal conditioning parts, system control parts using FPGA and PC monitoring program. For the evaluation of the implemented system, the simulation of system's control part was performed and the model system for the lower urinary system was designed. From the evaluation of the model system, the mean error rate of the uroflow measurement part was 1.08% and coefficient of variation was 1,48. And the mean error rate of the noninvasive bladder pressure measurement part was 2.41% and coefficient of variation was 2.81. urophongraphy signal analysis was accomplished in a time domain and frequency domain. Average RMS power was used in a time domain analysis, and MF was used in a frequency domain analysis. From the evaluation of the model system average RMS power and MF was dependent on the occlusion degree significantly and median frequency range of $60{\sim}160Hz$ was correlated with the occlusion.

  • PDF

Usefulness Assessment of Noninvasive Bladder Pressure Measurement for BPH Diagnosis (전립선 비대증 진단에서의 비침습적 방광내압계측 유용성 평가)

  • Jeong, Do-Un;Chung, Wan-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.865-866
    • /
    • 2006
  • The aim of this study was to implement the system that could evaluate the function of urinary tract with noninvasive and comfort methods. There for in this study hardware device and computer software have been developed that enables the analysis of the urine flow rate and vesical pressure signal measured during voiding. These signals were recorded simultaneously and transmitted to the PC. For the measurement system evaluation, the model system for the lower urinary system of men was designed. From the evaluation of the model system, vesical pressure was correlated with the occlusion degree. In a pilot study on 5 male subjects, means of standard deviation was 1.06, average error rate was 2.09 and coefficient variation was 2.09.

  • PDF

Development of an Improved Animal Model of Overactive Bladder: Transperineal Ligation versus Transperitoneal Ligation in Male Rats

  • Kim, Woo Hyun;Bae, Woong Jin;Park, Jung Woo;Choi, Jin Bong;Kim, Su Jin;Cho, Hyuk Jin;Ha, U Syn;Hong, Sung Hoo;Lee, Ji Youl;Hwang, Sung Yeoun;Kim, Sae Woong
    • The World Journal of Men's Health
    • /
    • v.34 no.2
    • /
    • pp.137-144
    • /
    • 2016
  • Purpose: We compared a transperineal ligation model and a transperitoneal ligation model in male rats to determine which animal model of overactive bladder (OAB) was more useful based on cystometrography, estimations of oxidative stress, and measurements of pro-inflammatory cytokine levels. Materials and Methods: Male rats were randomly divided into three groups (n=15 in each): the control group, the transperineal ligation group, and the transperitoneal ligation group. Four weeks after the ligation procedure, cystometrography was performed and oxidative stress, pro-inflammatory cytokine levels, and histologic changes were evaluated. Oxidative stress was assessed by measuring 8-hydroxy-20-deoxyguanosine and superoxide dismutase, and pro-inflammatory cytokine activity was investigated by measuring levels of interleukin (IL)-6, IL-8, and tumor necrosis $factor-{\alpha}$. Results: The transperineal model led to results similar to those observed for the transperitoneal model, namely (1) increased voiding frequency and reductions in the non-voiding contraction interval and the maximal vesical pressure, (2) increased levels of oxidative stress markers, (3) increased pro-inflammatory cytokine levels, and (4) fibrotic changes in the bladder tissue. Conclusions: We suggest that the transperineal procedure can be used as an alternative OAB model in male rats.