• Title/Summary/Keyword: Urban temperature simulation

Search Result 115, Processing Time 0.03 seconds

A Numerical Simulation for Thermal Environments by the Modification of Land-use in Busan (부산지역 토지이용(land-use) 변화에 의한 열환경 수치모의)

  • 김유근;문윤섭;오인보;임윤규
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.453-463
    • /
    • 2002
  • Prognostic meteorological model, MM5V3 (Mesoscale Model 5 Version 3) was used to assess the effects of the land-use modifications on spatial variations of temperature and wind fields in Busan during the selected period of summer season in 2000. We first examined sensitivity analysis for temperature between MM5V3 predictions and meteorological data observed at 4 AWS (Automatic Weather System) stations in Busan, which exhibited low structural and accurate errors (Mean Bias Error, MBE: 0.73, Root Mean Square Error, RMSE: 1.18 on maximum). The second part of this paper, MMSV3 simulations for the modification of land-use was performed with 1 km resolution in target domain, 46$\times$46 $\textrm{km}^2$ area around city of Busan. It was found that modification result from change of surface land-use in central urban area altered spatial distributions of temperature and wind. In particular, heat island core moved slightly to the seaward at 1300 LST. This results may imply that modification of surface land-use leads to change the thermal environments; in addition, it has a significant effect on local wind circulations and dispersions of air pollutants.

Evaluation of Condensation Prevention for Centralized Hybrid Ventilation System Using TDR (TDR을 이용한 중앙집중형 하이브리드 환기시스템의 결로방지 성능 평가)

  • Kim, Yu-Min;Lee, Jong-Eun;Choi, Gyeong-Seok;Lee, Yong-Jun;Kang, Jae-Sik
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.81-86
    • /
    • 2015
  • Purpose: Condensation in the apartment housing is one of the most significant defects and complaints for condensation are rapidly increasing according to the growing interest in residential environment. Korea government established a regulation for reducing condensation in the apartment housing and TDR is adapted as a standard. However prevention of condensation depend on improving the performance of building envelop has limitation because of the increase of the cost. Centralized Hybrid ventilation system is suggested to prevent condensation. Method: Field measurement was conducted to verify the ventilation rate of the ventilation system. Based on the measurement, air network and CFD simulation was conducted to analyze ventilation rate for each room. Surface temperature was calculated by regulated TDR according to the regions and surfaces. The performance of condensation prevention was evaluated by the ventilation rate and surface temperature. Result: In the results, it was found that condensation was prevented in more than 90% of households by the centralized hybrid ventilation system which provided 0.19 ~ 0.81ACH for each room.

Urban Street Planting Scenarios Simulation for Micro-scale Urban Heat Island Effect Mitigation in Seoul (미시적 열섬현상 저감을 위한 도시 가로수 식재 시나리오별 분석 - 서울시를 대상으로 -)

  • Kwon, You Jin;Lee, Dong Kun;Ahn, Saekyul
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.1
    • /
    • pp.23-34
    • /
    • 2019
  • Global warming becomes a serious issue that poses subsidiary issues like a sea level rise or a capricious climate over the world. Because of severe heat-wave of the summer in Korea in 2016, a big attention has been focused on urban heat island since then. Not just about heat-wave itself, many researches have been concentrated on how to adapt in this trendy warming climate and weather in a small scope. A big part of existing studies is mitigating "Urban Heat Island effect" and that is because of huge impervious surface in urban area where highly populated areas do diverse activities. It is a serious problem that this thermal context has a high possibility causing mortality by heat vulnerability. However, there have been many articles of a green infrastructures' cooling impact in summer. This research pays attention to measure cooling effect of a street planting considering urban canyon and type of green infrastructures in neighborhood scale. This quantitative approach was proceeded by ENVI-met simulation with a spatial scope of a commercial block in Seoul, Korea. We found the dense double-row planting is more sensitive to change in temperature than that of the single-row. Among the double-row planting scenarios, shrubs which have narrow space between the plant and the land surface were found to store heat inside during the daytime and prevent emitting heat so as to have a higher temperature at night. The quantifying an amount of vegetated spaces' cooling effect research is expected to contribute to a study of the cost and benefit for the planting scenarios' assessment in the future.

A Study on the Ventilation Improvement of Diesel Locomotive Engine Load Test Building using Computational Fluid Dynamics (전산유체역학을 이용한 디젤엔진 부하시험장의 환기 개선에 관한 연구)

  • Park Duckshin;Jeong Byungcheol;Cho Youngmin;Park Byunghyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.227-242
    • /
    • 2005
  • The aim of this study is to relieve the poor ventilation problem of the diesel locomotive engine load test building, located in an urban area. This paper evaluates the ventilation performances of the studied load test building based on the temperature measurement experiment and the computational fluid dynamics (CFD) during the engine load test. The temperature rise caused by the radiator blower of the building was turned out to be the main cause of disturbing the thermal conditions of the building. The indoor temperature distributions simulated by Fluent were validated with the temperature measurement results obtained from the studied building. The simulation results indicated that the comfort condition of this building was poor We suggested several remedial changes in the duct structure of this building for the improvement of the comfort conditions. In addition, a prototype drawing combining several improved design options was proposed. and then the simulation of the temperature distribution in the proposed prototype was performed. The result indicated that the indoor thermal condition of this proposed building was improved when compared with that of the current building.

Performance Simulation of Geothermal Heat Pump (GHP) System with Different Control Schemes (제어 방식에 따른 지열 히트펌프 시스템의 성능 시뮬레이션)

  • Lee, Doo-Young;Choi, Jae-Ho;Min, Kyong-Chon;Sohn, Byonghu
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.35-41
    • /
    • 2016
  • Geothermal heat pump (GHP) systems have been proved to be one of the most efficient systems for heating and cooling in buildings. However, an optimal energy performance depends on a good control of the system components, including heat pumps and circulation pumps, which affect to the total energy consumption of system. This paper presents the simulation results of the heat pump performance for two different control schemes, i.e. constant setting temperature (Control-A) and variable setting temperatures (Control-B) in buffer tank. A dynamic simulation tool, TRNSYS 17, was used to model the entire system and to assess the performance of the system. Simulation results show that the Control-B, which controls the temperature in buffer tank with outdoor air temperature, is a effective way to reduce the energy consumptions in heat pump (7.7%) and circulation pump (7.5%).

A Study on the Analysis of Temperature Reduction Effect by the Types and Public Awareness of the Green Roof (옥상녹화의 녹화유형별 기온저감효과 및 시민의식 분석)

  • Lee, Chun-Woo;Kim, Soo-Bong;Moon, Hye-Shick;Jeon, Eun-Jeong
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.316-320
    • /
    • 2009
  • Recently, concerns about conserving proper size of urban green spaces and accessibility are increasing, regarding it as a solution to diverse urban environmental problems including pollution, ecosystem deterioration, urban climate change. Artificial ground greening such as green roofs is regarded as the only alternative that can conserve green spaces which are impossible to be secured on the ground. However, green roofs are not popularized yet and levels are very low in provincial cities despite of related technology development and support systems of related agencies. Based on the background, this study tries to present a theoretical basis of methods for green roofs, conducting green roof simulations and collecting ideas about problems and improving measures from green roof users. Finally, it aims to offer base data which help establish policy direction for activation of green roof technology. As a result of a simulation for verifying temperature reduction effect, it was possible to affirm effect of a plot that green roofs applied. Especially, it was revealed that a green roof method using ground covers such as mixed planting was the most effective way to reduce temperature. Activation methods for green roofs based on this study are as follows: First, it is a priority to readjust systems related to green roofs. Second, citizens' active and voluntary participation must be attained. Third, it is required to establish detailed promotion procedures which aim at actual conduct and to maintain an expert department which is able to manage and control the establishment. After conduct, continuous aftercare stages are also needed.

  • PDF

An Experimental and Simulation Analysis of Condensation in the Walk-in Closet Attached to Apartment Bathroom (욕실과 인접한 아파트 드레스룸의 결로 원인 분석)

  • Choi, Young-Woo;Kim, Sean Hay
    • KIEAE Journal
    • /
    • v.17 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • Purpose: Condensation in walk-in closets attached to apartment bathroom has been known as an emerging issue that may threat occupants' comfort and health. Despite a number of design guidelines and enforcements to prevent condensation, condensation issues may still occur depending on various cases and scenarios. We aim to identify what condensation scenarios may lead to walk-in closet condensation and/or worse the existing condensation issues. Method: First we choose an actual walk-in closet of an apartment that suffers from sporadic condensation and resulting mold and mildew. Then we observe its relative humidity and temperature after the bathroom is used, in which excessive vapor is thought to be transported to the walk-in closet. We analyze Temperature Difference Ratio - a domestic indicator of condensation occurrence, and dew point temperature to compare it with surface temperature using 2D heat transfer simulation upon various condensation scenarios. Result: TDR of the test walk-in closet turns out be OK despite mold and mildew actually occurring. Hot water pipe installed in the floor would greatly reduce condensation. If hot water pipe in the upper floor, however, is not used, or hot water pipe of the closet is turned off during swing seasons, it is expected that condensations may still occur.

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

A Study on Generator Temperature and Power Converter Efficiency according to change of Wind Velocity (풍속 변화에 따른 발전기 온도 및 전력변환장치 효율에 관한 연구)

  • Song, Young-Sang;Han, Woon-Ki;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo;Jeon, Taehyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.7
    • /
    • pp.8-13
    • /
    • 2015
  • Recently, because a renewable power source must operate as a constant rate in accordance with RPS(Renewable Portfolio Standard), the study of the renewable power sources has been ongoing. Especially because of noise of wind turbine, troubleshooting, and urban greening business, research related with small wind turbine are underway. The economics and reliability are important parts for the activation of small wind turbine, such as solar energy. In this paper, by analyzing the temperature variations for each location and efficiency of power conversion devices in accordance with short period wind speed changes in simulation test, we reviewed the safety about temperature variations of wind generator and the method of selection of power converter.

The Study on Establishment of the Urban Atmospheric Environment Map for Analysis of Atmospheric Environment in Busan Metropolitan City (부산광역시 대기환경 파악에 활용가능한 도시대기환경지도 작성에 관한 연구)

  • Kim, Min-Kyoung;Jung, Woo-Sik;Lee, Hwa Woon
    • Journal of Environmental Science International
    • /
    • v.24 no.6
    • /
    • pp.807-817
    • /
    • 2015
  • In this study the urban atmospheric environment map in Busan was made and it consist of the atmospheric environment element map and the atmospheric environment analysis map. The atmospheric environment element map covered the topography, the urban climate, the air pollutant emission, ozone and PM10 concentrations in Busan and the atmospheric environment analysis map included the thermal environment and the wind flow by using WRF meteorological numerical simulation. The meteorological elements from 2007 to 2011 in Busan were used in this study. As a result, in the center of Busan and Buk-gu along to the Nakdong river was the temperature high. To analyze the air flow of Busan 3 clusters depending on the wind direction were extracted with the cluster analysis. The results of the analysis on the detailed wind field of each cluster showed that the weak ventilation could be happened locally at the specific meteorological condition.