• Title/Summary/Keyword: Urban temperature simulation

Search Result 116, Processing Time 0.033 seconds

Ventilation Load Reduction Plan Using Cool Tube System Case (Cool Tube System 사례를 활용한 환기부하 절감방안)

  • Jeong, Min Yeong;Park, Jin Chul;Yang, Young Kwon
    • Land and Housing Review
    • /
    • v.10 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • In this study, the case analysis data on underground temperature are presented. In addition, numerical analysis of the ventilation load reduction plan was derived according to the residence schedule change for the building with cool tube. The research scope and method are as follows. The overall system principle was examined through reviewing the theory of the Cool tube system. Case study and analysis were conducted. Numerical simulation was used to examine the change in energy usage. Also, the change of load energy in case of varying amount of ventilation was derived based on actual building room schedule. When the Cool tube system was applied to the residential buildings, the cooling load was reduced from 3,331 kW to 193 kW, which showed a reduction effect of about 90%.The heating load was reduced from 42,276kW to 32,575kW by 23%.Also, result shows that the cooling load decreased by 24% and the heating load decreased by 66% when the number of ventilation according to the occupancy schedule was applied.

Estimation of Flame Temperature Ejected from the Opening for the Development of Urban Fires Simulation. (도시화재 시뮬레이션 구축을 위한 개구분출화재의 온도 예측)

  • Kim, Nam-Hyuk;Shin, Yi-Chul;Koo, In-Hyuk;Nam, Dong-Gun;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.346-350
    • /
    • 2010
  • 도시화재의 연소 확대성상을 모델화하기 위해 화재실의 개구를 통하여 분출하는 열기류의 온도 평가 실험을 실시하였다. 실험은 축소모형 형태로 개구 조건과 화원조건에 의해 진행이 되었다. 실험 결과 온도분포 Trajectory는 개구종횡비 n에 의해 횡정(橫井)의 연구결과와 비교하여 n=2일때를 제외하고는 다른 경향을 나타냈다. 동일 조건에서 분출화재보유열량 $Q_{ef}$은 개구 조건이 횡장창($B0.2m{\times}H0.1m$)이고, 단일개구일 때 가장 높은 값을 나타냈다. 또한, 분출화재의 발생 한계 발열속도 $Q_{verit}$에서도 굴웅아(堀雄児)의 연구와 유사한 결과를 보이며, 다른 개구조건보다 횡장창($B0.2m{\times}H0.1m$)일 때 높은 값을 나타냈다.

  • PDF

E/V Shaft Cooling Method as a Stack Effect Countermeasure in Tall Buildings

  • Lee, Joonghoon;Song, Doosam;Jeong, Eunyoung
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.2
    • /
    • pp.99-105
    • /
    • 2012
  • The higher the building height and the larger the temperature difference between the outdoor and indoor space, the more remarkable is the draft driven by the stack effect in high-rise buildings. Moreover, the stack effect can bring about the deterioration of habitability and the degradation of the performance of the indoor control system in high-rise buildings. In this study, as a measure to attenuate the stack effect, the E/V shaft cooling method was proposed and its performance was compared with the conventional stack effect control method for strengthening the air-tightness of the building using a numerical simulation method. The total decreasing ratios on the stack effect in a building were compared, and the probabilities of the secondary problems were analyzed. The results show that the E/V shaft cooling is very effective to decrease the stack effect in a high-rise building in terms of the reduction performance and application. Moreover, this method does not cause secondary problems, such as stack pressure transition to other walls, unlike the conventional stack effect mitigation method.

Preliminary Modelling of Plasco Tower Collapse

  • Yarlagadda, Tejeswar;Hajiloo, Hamzeh;Jiang, Liming;Green, Mark;Usmani, Asif
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.397-408
    • /
    • 2018
  • In a recent tragic fire incident, the Plasco Tower collapsed after an intense outburst of fire lasting for three and a half hours and claiming the lives of 16 firefighters and 6 civilians. This paper will present continuing collaborative work between Hong Kong Polytechnic University and Queen's University in Canada to model the progressive collapse of the tower. The fire started at the 10th floor and was observed to have travelled along the floor horizontally and through the staircase and windows vertically. Plasco Tower was steel structure and all the steel sections were fabricated by welding standard European channel or angle profiles and no fire protection was applied. Four internal columns carried the loads transferred by the primary beams, and box columns were constructed along the perimeter of the building as a braced tube for resisting seismic loading. OpenSees fibre-based sections and displacement-based beam-column elements are used to model the frames, while shell elements are used for the reinforced concrete floor slabs. The thermal properties and elevated temperature mechanical properties are as recommended in the Eurocodes. The results in this preliminarily analysis are based on rough estimations of the structure's configuration. The ongoing work looks at modeling the Plasco Tower based on the most accurate findings from reviewing many photographs and collected data.

A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis (가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구)

  • Ah-Reum, Kim;Byeong Sub, Kwak;Tae-Hyun, Jun;Hyun-joo, Park
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

Analysis of Thermal Environment Impact by Layout Type of Apartment Complexes for Carbon Neutrality Net-Zero: Based on CFD Simulation (공동주택단지 배치유형별 열환경 영향성 분석: 유체역학 시뮬레이션을 기반으로)

  • Gunwon Lee;Youngtae Cho
    • Land and Housing Review
    • /
    • v.14 no.3
    • /
    • pp.93-106
    • /
    • 2023
  • This study attempted to simulate changes in the thermal environment according to the type of apartment complex in Korea using CFD techniques and evaluate the thermal environment by type of apartment. First, apartment complex types in the 2000s and 2010s were referred from previous studies and four types of apartment complex were extracted from. Second, the layout of the apartment complex and temperature changes were analyzed by the direction of wind inflow. Third, a standardized model was created from each type using tower type, plate type, and mixed driving. Last, CFD simulations were performed by setting up the inflow of wind from a total of eight directions. The temperature was relatively low in the type consisting of only the tower type and the type of placing the tower type in the center of the complex, regardless of the direction of the wind. It was due to the good inflow of wind from these types to the inside of the complex. It can be interpreted because wind flows easily into the complex in these types. The findings showed that wind flow and resulting temperature distribution patterns differed depending on the building type and complex layout type, confirming the need for careful consideration of the complex layout in the early design stage. The results are expected to be used as basic data for creating a sustainable residential environment in the early design stage of apartment complexes in the future.

Performance Evaluation of the High-Resolution WRF Meteorological Simulation over the Seoul Metropolitan Area (WRF 모형의 수도권 지역 상세 국지 기상장 모의 성능 평가)

  • Oh, Jun-Seo;Lee, Jae-Hyeong;Woo, Ju-Wan;Lee, Doo-Il;Lee, Sang-Hyun;Seo, Jihyun;Moon, Nankyoung
    • Atmosphere
    • /
    • v.30 no.3
    • /
    • pp.257-276
    • /
    • 2020
  • Faithful evaluation of the meteorological input is a prerequisite for a better understanding of air quality model performance. Despite the importance, the preliminary meteorological assessment has rarely been concerned. In this study, we aim to evaluate the performance of the Weather Research and Forecasting (WRF) model conducting a year-long high-resolution meteorological simulation in 2016 over the Seoul metropolitan area. The WRF model was configured based on a series of sensitivity simulations of initial/boundary meteorological conditions, land use mapping data, reanalysis grid nudging method, domain nesting method, and urban canopy model. The simulated results of winds, air temperature, and specific humidity in the atmospheric boundary layer (ABL) were evaluated following statistical evaluation guidance using the surface and upper meteorological measurements. The statistical evaluation results are presented. The model performance was interpreted acceptable for air quality modeling within the statistical criteria of complex conditions, showing consistent overestimation in wind speeds. Further statistical analysis showed that the meteorological model biases were highly systematic with systematic bias fractions (fSB) of 20~50%. This study suggests that both the momentum exchange process of the surface layer and the ABL entrainment process should be investigated for further improvement of the model performance.

Comparison of Disaster Vulnerability Analysis and Risk Evaluation of Heat Wave Disasters (폭염재해의 재해취약성분석 및 리스크 평가 비교)

  • Yu-Jeong SEOL;Ho-Yong KIM
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.26 no.1
    • /
    • pp.132-144
    • /
    • 2023
  • Recently, the frequency and intensity of heat waves due to the increase in climate change temperature are increasing. Therefore, this study tried to compare the evaluation process and evaluation results of the heat wave disaster evaluation, which is the government's analysis of the heat wave disaster vulnerability and the risk evaluation method recently emphasized by the IPCC. The analysis of climate change disaster vulnerability is evaluated based on manuals and guidelines prepared by the government. Risk evaluation can be evaluated as the product of the possibility of a disaster and its impact, and it is evaluated using the Markov chain Monte Carlo simulation based on Bayesian estimation method, which uses prior information to infer posterior probability. As a result of the analysis, the two evaluation results for Busan Metropolitan City differed slightly in the spatial distribution of areas vulnerable to heat waves. In order to properly evaluate disaster vulnerable areas due to climate change, the process and results of climate change disaster vulnerability analysis and risk assessment must be reviewed, and consider each methodology and countermeasures must be prepared.

The Application of High-resolution Land Cover and Its Effects on Near-surface Meteorological Fields in Two Different Coastal Areas (연안지역 특성에 따른 상세 토지피복도 적용 효과 및 기상장에 미치는 영향 분석)

  • Jeong, Ju-Hee;Kim, Yoo-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.432-449
    • /
    • 2009
  • In this study, the effects of high-resolution land cover on the simulation of near-surface meteorological fields were evaluated in two different coastal regions using Weather Research and Forecasting (WRF) model. These analyses were performed using the middle classification land cover data upgraded by the Korean Ministry of Environment (KME). For the purpose of this study, two coastal areas were selected as follows: (1) the southwestern coastal (SWC) region characterized by complex shoreline and (2) the eastern coastal (EC) region described a high mountain and a simple coastline. The result showed that the application of high-resolution land cover were found to be notably distinguished between the SWC and EC regions. The land cover improvement has contributed to generate the realistic complex coastline and the distribution of small islands in the SWC region and the expansion of urban and built-up land along the sea front in the EC region, respectively. The model study indicated that the improvement of land cover caused a temperature change on wide areas of inland and nearby sea for the SWC region, and narrow areas along the coastal line for the EC region. These temperature variations in the two regions resulted in a decrease and an increase in land-breeze and sea-breeze intensity, respectively (especially the SWC region). Interestingly, the improvement of land cover can contribute large enough to change wind distributions over the sea in coastal areas.

Numerical Interpolation on the Simulation of Air Flow Field and the Effect of Data Quality Control in Complex Terrain (객관 분석에 의한 복잡지형의 대기유동장 수치모의와 모델에 의한 자료질 조절효과)

  • Lee Hwa woon;Choi Hyun-Jung;Lee Kang-Yoel
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.1
    • /
    • pp.97-105
    • /
    • 2005
  • In order to reduce the uncertainties and improve the air flow field, objective analysis using asynoptic observational data is chosen as a method that enhances the reality of meteorology. In surficial data and their numerical interpolation for improving the interpretation of meteorological components, objective analysis scheme should perform a smooth interpolation, detect and remove the bad data and carry out internal consistency analysis. For objective analysis technique which related to data reliability and error suppression, we carried out two quality control methods. In site quality control, asynoptic observational data at urban area revealed low representation by the complex terrain and buildings. In case of wind field, it was more effective than temperature field when it were interpolated near waterbody data. Many roads, buildings, subways, vehicles are bring about artificial heat which left out of consideration on the simulation of air flow field. Therefore, in temperature field, objective analysis for more effective result was obtained when surficial data were interpolated as many as possible using value quality control rather than the selection of representative site.