• Title/Summary/Keyword: Urban air quality

Search Result 388, Processing Time 0.029 seconds

Issue Difference of Ecosystem Service Demand and Supply through Text Mining Analysis: Case Study of Shiheung using Complaints and Urban Planning Materials (텍스트 마이닝 분석을 통한 생태계서비스 수요-공급의 이슈 차이분석 - 시흥시 민원과 도시계획 자료를 활용하여 -)

  • Lee, Jae-hyuck;Park, Hong-jun;Kim, Il-kwon;Kwon, Hyuk-soo
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.3
    • /
    • pp.63-71
    • /
    • 2018
  • The comparison of demand and supply is needed for efficient ecosystem services planning. However, the gap between them cannot be analyzed as existing studies mainly dealt with only the supply of ecosystem services. This study compares the demand and supply of ecosystem services in Shiheung using environmental complaints and urban planning by semantic network analysis. As a result, 'air' and 'water' quality are magnified in demand, 'energy' and 'water' are crucial in supply. This result presents that citizen ask for the improvement of air quality in regulation services, although local government has plans for energy support in provisioning services. Periodic ecosystem services demand and supply monitoring will be the base of effective ecosystem services planning, which reduce insufficiency and surplus.

A Study on the Application Cases of Smart Environment Management in Urban Area (도시지역의 스마트 환경관리 적용 사례에 대한 고찰)

  • Park, Chanjin
    • Journal of Urban Science
    • /
    • v.11 no.2
    • /
    • pp.31-44
    • /
    • 2022
  • In this study, smart environmental management, which is an essential element for building a sustainable city, was studied. Incheon area in the metropolitan area was selected as a research subject, the recent atmospheric environment was reviewed comprehensively, and the main air quality policies of Incheon city were summarized. The smart environment management application cases were organized and analyzed to summarize the results. Based on this study, smart environment management plans for the creation of a smart city in an urban area were suggested.

Quality Control on Neutron Activation Analysis for Urban Dust by the Proficiency Test (비교숙련도 시험을 통한 도시대기분진에 대한 중성자방사화분석법의 품질관리)

  • Moon, Jong-Hwa;Kim, Sun-Ha;Chung, Yong-Sam
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.433-438
    • /
    • 2002
  • Trace elements in two air filters (V-50, P-50) artificially loaded with urban dust provided from IAEA were determined non-destructively using instrumental neutron activation analysis. Standard reference material (Urban Particulate Matter, SRM 1648) of National Institute of Standard and Technology was used for analytical quality control. About 20 elements in both of loaded filter samples were determined. To evaluate inter-laboratory comparison and proficiency test, analytical data were statistically treated with the results which collected from 49 laboratories, 40 countries participated in this study using neutron activation analysis, particle induced X-ray emission, inductively coupled plasma mass spectroscopy, etc,. From the results of statistical treatment, Z-scores are within ${\pm}2$. Furthermore, accuracy and precision of obtained analytical values are passed according to the criteria of the proficiency test. Consequently, it was proved that analytical quality for air dust samples being performed has been controlled properly.

A Study on Air Pollution Measurement Model in Inchon City (인천직할시 대기오염 측정 MODEL의 개발)

  • 김윤선;이동인
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.102-108
    • /
    • 1996
  • Urban air pollution has been gradually increasing by the increase of population and vehicles recently. There are shown larger effects of air pollution in Incheon city which has more than 2 million people and has heavy holding amounts ratio of transportation vehicles as compared with other cities. However, it is very difficult to predict the air quality condition of their moving pollutants. Therefore, in this study air pollution measuring model was designed to estimate the air pollution level by line sources(transprtation vehicles ) of air pollutants and to detect the $NO_x$ emission amounts in ordinary times, and it became clear that it is functionally operative.

  • PDF

Analysis of Cold Air Flow Characteristics according to Urban Spatial Types to Construct a Wind Road - Focused on Urban Area of Changwon - (바람길 조성을 위한 도시공간유형별 찬공기 유동 특성 분석 - 창원시 도시지역을 중심으로 -)

  • LEE, Su-Ah;SONG, Bong-Geun;PARK, Kyung-Hun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.25 no.2
    • /
    • pp.30-47
    • /
    • 2022
  • This study analyzed the characteristics of cold air flow according to spatial types in urban areas of Changwon-si, Gyeongsangnam-do. The spatial types were classified by cluster analysis considering the land use map, building information, and topographic characteristics produced on the Changwon biotope map. The amount of cold air and wind speed were derived by KLAM_21 modeling. As a result, spatial types were classified into a total of 14 types considering the density and height of buildings, land use types, and topographic characteristics. Cold air flow was found to generate cold air in the valley of the forest area outside urban area, move through roads and open spaces, and accumulate in the low-lying national industrial complex, and then spread cold air throughout the urban areas. There was a lot of cold air flow in the tall building area, and the cold air accumulation was less in the slope and ridge areas. The results of this study were able to understand the characteristics of cold air flow according to building density, land use type, and topography, which will be usefully used as basic data for urban wind road construction to mitigate climate and improve air quality in urban areas.

Urban Greening: A Sustainable Method for Particulate Matter (PM) Reduction

  • Sanghee Park;Myeong Ja Kwak;Jongkyu Lee;Yea Ji Lim;Handong Kim;Su Gyeong Jeong;Joung-a Son;Hanna Chang;Sun Mi Je;Chang-Young Oh;Kyongha Kim;Su Young Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.1
    • /
    • pp.1-10
    • /
    • 2023
  • Urbanization and industrialization associated with rapid economic development have resulted in air pollution in urban areas, which adversely affects human health and the environment around the world. Growing awareness of the health effects of airborne particulate matter (PM) has led to the emergence of urban greening as a promising eco-friendly, nature-based solution to reduce the concentration of PM (especially PM2.5) to which individuals are exposed, thereby promoting public health. In this review, we highlight fundamental insights about PM and recent research on the ability of urban greening to capture PM. Reports from the scientific literature on PM published from 1992 to 2021 were retrieved from Google Scholar. Here, we explore some of the main complex relationships between leaf traits and the ability to retain PM for research or management to optimize greenspaces.

Size distributions of atmospheric particulate matter and associated trace metals in the multi-industrial city of Ulsan, Korea

  • Kwon, Hye-Ok;Park, Min-Kyu;Kim, Seong-Joon;Choi, Jinsoo;Oh, Jun;Ahn, Joon-Young;Choi, Sung-Deuk
    • Environmental Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.331-338
    • /
    • 2019
  • Particulate matter (PM) was collected using micro-orifice uniform deposit impactors from a residential (RES) site and an industrial (IND) site in Ulsan, South Korea, in September-October 2014. The PM samples were measured based on their size distributions (11 stages), ranging from $0.06{\mu}m$ to over $18.0{\mu}m$. Nine trace metals (As, Se, Cr, V, Cd, Pb, Ba, Sb, and Zn) associated with PM were analyzed. The PM samples exhibited weak bimodal distributions irrespective of sampling sites and events, and the mean concentrations of total PM (TPM) measured at the IND site ($56.7{\mu}g/m^3$) was higher than that measured at the RES site ($38.2{\mu}g/m^3$). The IND site also showed higher levels of nine trace metals, reflecting the influence of industrial activities and traffic emissions. At both sites, four trace metals (Ba, Zn, V, and Cr) contributed to over 80% of the total concentrations in TPM. The modality of individual trace metals was not strong except for Zn; however, the nine trace metals in $PM_{2.5}$ and $PM_{10}$ accounted for approximately 50% and 90% of the total concentrations in TPM, respectively. This result indicates that the size distributions of PM and trace metals are important to understand how respirable PM affects public health.

A Study on the Microbial Air Pollution of Urban Living and Indoor Environment (생활환경과 실내공기의 미생물학적 오염에 관한연구)

  • 정윤희;홍준배;장윤희
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.1-9
    • /
    • 2001
  • This study was carried out to investigate the microbial characteristics of the urban air pollution in the subway stations, streets, department stores, wholesale markets, underground shopping centers, buildings, parks, houses and apartments in the Seoul and the suburbs area. Total cell count, total mold count and the presence of opportunistic pathogens(Streptococcus pneumoniae, Klebsiella pneumoniae, Aspergillus spp., Penicillium spp.) were evaluated determine the microbial air quality. Total cell count and mold count of indoor air in the houses and apartments were 2.9$\times$10$^2$-6.3$\times$10$^2$cfu/㎥ and 60-1.8$\times$10$^2$cfu/㎥, respectively, and the department stores and wholesale markets had much lower cell count than the houses and apartments. Ground level of commercial stations were 2.6 fold higher than the general subway stations, and Apergillus spp. and Penicillium spp. which could cause the bronchus and lung diseases were detected 17 sampling site out of 45. Dust were collected from the commercial facilities and houses, and total cell and mold count of the dust were 4.3$\times$10$^3$-1.7$\times$10$^{6}$ cfu/g and 2.3$\times$10$^3$-6.5 $\times$10$^4$cfu/g, respectively. Therefore the dust might be one of the main reservoir of microorganims.

  • PDF

A Method for monitoring air pollution using base stations (이동통신 기지국을 이용한 대기환경 모니터링)

  • Oh, Hyun-Jung;Lee, Jae-Wook;Baik, Song-Hoon
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.205-208
    • /
    • 2008
  • This article presents a methodology for the monitoring of air pollution. All over the world, the interest in the environment has been continuously increasing. Unfortunately, much of this interest is due to emerging problems, such as the greenhouse effect and climate change. For this reason, research into carbon dioxide, which causes the greenhouse effect, is progressing rapidly. This article presents a method of measuring the level of carbon dioxide and other substances in the air through the utilization of mobile-networking base stations and measured data. First of all, sensors are attached at the appropriate position of the mobile-networking base stations. These sensors will measure the air quality in their respective positions, and send sensor data to an urban management center via network gateways and data-collecting systems. The measured data can be used for various purposes. In general, it can be used to measure the air quality, which can then be used as a basis for urban planning. The method described herein utilizes airpollution sensors that are attached to the base stations in different locations and at varying heights. The data obtained hereby will be applicable in many fields. At this time this is simply a methodology, however we hope that it will lead to a practical application.

  • PDF

Energy Saving Potential and Indoor Air Quality Benefits of Multiple Zone Dedicated Outdoor Air System

  • Lee, Soo-Jin;Jeong, Jae-Weon
    • International Journal of High-Rise Buildings
    • /
    • v.8 no.1
    • /
    • pp.71-82
    • /
    • 2019
  • The purpose of this study is to evaluate the indoor air quality (IAQ) and energy benefits of a dedicated outdoor air system (DOAS) and compare them with a conventional variable air volume (VAV) system. The DOAS is a decoupled system that supplies only outdoor air, while reducing its consumption using an enthalpy wheel. The VAV system supplies air that is mixed outdoor and transferred indoor. The VAV has the issue of unbalanced ventilation in each room in multiple zones because it supplies mixing air. The DOAS does not have this problem because it supplies only outdoor air. That is, the DOAS is a 100% outdoor air system and the VAV is an air conditioning system. The transient simulations of carbon dioxide concentration and energy consumption were performed using a MATLAB program based on the thermal loads from the model predicted by the TRNSYS 18 program. The results indicated that when the air volume is large, such as in summer, the distribution of air is not appropriate in the VAV system. The DOAS however, supplies the outdoor air stably. Moreover, in terms of annual primary energy consumption, the DOAS consumed approximately 40% less energy than the VAV system.