• Title/Summary/Keyword: Urban air monitoring network

Search Result 17, Processing Time 0.028 seconds

Feasibility Study for the Location of Air Quality Monitoring Network in Daegu Area (대구지역 대기오염자동측정망 위치의 타당성 분석)

  • Choi, Sung-Woo;Lee, Jung-Beom
    • Journal of Environmental Science International
    • /
    • v.20 no.1
    • /
    • pp.81-91
    • /
    • 2011
  • Air quality monitoring networks are very important facilities to manage urban air pollution control and to set up an environmental policy. Since air quality monitoring network of Daegu was allocated from 1980s to mid-90s, there is need to reevaluate it and relocated its site. This study was evaluated the position of Daegu air quality monitoring station by unit environmental sensitivity index, grid emission rate, CAI (Comprehensive Air-quality Index) point. The investigation domain covered an area of 16 $\times$ 24 km centered at the metropolitan area of Daegu with grid spacing of 2 km. The location of alternative air quality monitoring networks was selected through optimization and quintiles analysis of total score. The result showed that all things considered, new air quality monitoring network need to install grid numbers 10, 28, 36, 37, 46. We also recommand three scenarios of alternative air quality monitoring network when considering unit environmental sensitivity index, emission rate and CAI point.

Study on Optimal Location of Air Pollution Monitoring Networks in Urban Area Using GIS : Focused on the case of Seoul City (GIS를 이용한 도심지 대기오염 측정망 최적위치 선정에 대한 연구 : 서울특별시를 대상으로)

  • Kim, Ayoung;Kwon, Changhee
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.4
    • /
    • pp.358-365
    • /
    • 2016
  • Micro dust is closely related to real life. Especially, the micro dust forecasting system is being implemented from February 2014. Reliability of data through air pollution monitoring network is important. The Ministry of Environment operates 506 air pollution monitoring networks (11 types) to analyze national air quality and establish air policies. However, there is not enough system to confirm and check the site suitability of the measurement site. Therefore, this study analyzes urban space using GIS. Assess the appropriateness and equity of air pollution measurement facilities. The final goal is to reflect the results of the analysis into the Seoul Metropolitan Air Pollution Monitoring Network Installation Plan.

Suggestions on the Selection Method of Priority Monitoring Sites for Hazardous Air Pollutants in Megacities (유해대기오염물질 모니터링을 위한 대도시 우선순위 측정지점 선정기법 제안)

  • Kwon, Hye-Ok;Kim, Seong-Joon;Kim, Yong Pyo;Kim, Sang-Kyun;Hong, Ji-Hyung;Choi, Sung-Deuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.544-553
    • /
    • 2017
  • There is an overall guideline of the installation of air quality monitoring stations in Korea, but specified steps for the selection of monitoring sites for hazardous air pollutants(HAPs) are not provided. In this study, we proposed a systematic method for the selection of monitoring sites for HAPs using geographic information system (GIS). As a case study, the Seoul metropolitan area (Seoul, Incheon, and Gyeonggi Province) was chosen, and 15 factors including population, vehicle registration, and emission data were compiled for each grid cell ($7km{\times}7km$). The number of factors above the top 30% of individual data for each grid cell was used to select priority monitoring sites for HAPs. In addition, several background sites were added for data comparison and source identification. Three scenarios were suggested: Scenario 1 with 7 sites, Scenario 2 with 17 sites, and Scenario 3 with 30 sites. This proposal is not the final result for an intensive monitoring program, but it is an example of method development for selecting appropriate sampling sites. These results can be applied not only to HAPs monitoring in megacities but also to the national HAPs monitoring network.

Cluster Analysis of PM10 Concentrations from Urban Air Monitoring Network in Korea during 2000 to 2005 (전국 도시대기 측정망의 2000~2005년 PM10 농도 군집분석)

  • Han, Ji-Hyun;Lee, Mee-Hye;Ghim, Young-Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.3
    • /
    • pp.300-309
    • /
    • 2008
  • Variations in PM10 concentration between 2000 and 2005 from 84 urban air monitoring stations operated by the government were analyzed. The K-means cluster analysis was attempted using annual average and the 99th percentile of daily averages as parameters. The results obtained by excluding Asian dust episode days were compared with those obtained by using all available data. In any cases, the cluster with the highest mean concentration was mostly composed of stations in Seoul and Gyeonggi. Annual average of the cluster with the highest mean concentration showed a distinct decreasing trend, but that excluding Asian dust episode days did not show such a trend. Without Asian dust episode days high concentrations of monthly averages in March and April were also not observed. The effect of Asian dust was more pronounced in the 99th percentile of daily averages. The 99th percentile of daily averages of the cluster with the highest mean concentration was the highest in June following downs in April and May.

A Method for monitoring air pollution using base stations (이동통신 기지국을 이용한 대기환경 모니터링)

  • Oh, Hyun-Jung;Lee, Jae-Wook;Baik, Song-Hoon
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.205-208
    • /
    • 2008
  • This article presents a methodology for the monitoring of air pollution. All over the world, the interest in the environment has been continuously increasing. Unfortunately, much of this interest is due to emerging problems, such as the greenhouse effect and climate change. For this reason, research into carbon dioxide, which causes the greenhouse effect, is progressing rapidly. This article presents a method of measuring the level of carbon dioxide and other substances in the air through the utilization of mobile-networking base stations and measured data. First of all, sensors are attached at the appropriate position of the mobile-networking base stations. These sensors will measure the air quality in their respective positions, and send sensor data to an urban management center via network gateways and data-collecting systems. The measured data can be used for various purposes. In general, it can be used to measure the air quality, which can then be used as a basis for urban planning. The method described herein utilizes airpollution sensors that are attached to the base stations in different locations and at varying heights. The data obtained hereby will be applicable in many fields. At this time this is simply a methodology, however we hope that it will lead to a practical application.

  • PDF

On the Recent Air Pollution Levels Observed in the Regional Air Monitoring Network -High Air Pollution Concentration Episodes and Their Meteorological Characteristics in 2002 (지역 대기질 측정망에 나타난 국내 대기오염도의 최근 동향 -2002년 고농도 사례 및 그 기상 특징)

  • Kim C.-H;Park I.-S;Lee S.-J;Kim J.-S;Jin H.-A;Sung H.-G
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.2
    • /
    • pp.215-224
    • /
    • 2004
  • We report the high concentration episodes for PM$_{10}$, SO$_2$, NO$_2$, and $O_3$ in many urban areas Korea during 2002. The high concentration episodes are identified based on the National Ambient Air Quality Standards and the observations obtained from the Regional Air Monitoring Network composed of approximately 160 air pollution monitoring stations located in a number of major or big cities in South Korea including Seoul, Pusan, Daegu, and Incheon cities. The results show that the twenty cases of high concentration episodes in 2002 consists of both ozone warning episodes (6 cases) and high PM$_{10}$ concentration cases (14 cases), and one half of the latter are found to occur in association with the Yellow Sand (Asian Dust) phenomena. The most outstanding characteristics of the reported episodes are the excessively high levels of maximum PM$_{10}$ concentrations during the Yellow Sand period (i.e., exceeding 3,000$\mu\textrm{g}$/㎥ in April, 2002) and their variable occurrence frequencies across seasons. The high ozone concentration episode days are mainly resulting from both the high photochemical reactions and poor ventilations. The high PM$_{10}$ concentration days during non Yellow Sand periods, however, mostly occurred under the influence of synoptic meteorological conditions such as stagnant or slowly passing high pressure centers, and consequently prevailing weak wind speeds over the Korean peninsula. The overall results of our study thus suggest the importance of both synoptic and local meteorological factors for high concentration levels in the major and/or big cities in Korea.n Korea.

Investigation of Urban High Temperature Phenomenon in Summer using the High Density Ground Monitoring System in Daegu Metropolitan Area (지상 고밀도 관측 시스템을 이용한 대구의 여름철 고온현상 조사)

  • Kim, Sang-Heon;Cho, Chang-Bum;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1619-1626
    • /
    • 2014
  • We analyzed diurnal variations in the surface air temperature using the high density urban climate observation network in Daegu metropolitan city, the representative basin-type city in Korea, in summer, 2013. We used a total of 28 air temperature observation points data(16 thermometers and 12 AWSs). From the distribution of monthly average air temperature, air temperature at the center of Daegu was higher than the suburbs. Also, the days of daily minimum air temperature more than or equal to $25^{\circ}C$ and daily maximum air temperature more than or equal to $35^{\circ}C$ at the schools near the center of Daegu was more than those at other schools. This tendency appeared more clearly on the days of daily minimum air temperature more than or equal to $25^{\circ}C$. Also, the air temperature near the center of the city was higher than that of the suburbs in the early morning. Thus it was indicated that the air temperature was hard to decrease as the bottom of the basin. From these results, the influence of urbanization to the formation of the daily minimum temperature in Daegu was indicated.

Issue Difference of Ecosystem Service Demand and Supply through Text Mining Analysis: Case Study of Shiheung using Complaints and Urban Planning Materials (텍스트 마이닝 분석을 통한 생태계서비스 수요-공급의 이슈 차이분석 - 시흥시 민원과 도시계획 자료를 활용하여 -)

  • Lee, Jae-hyuck;Park, Hong-jun;Kim, Il-kwon;Kwon, Hyuk-soo
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.3
    • /
    • pp.63-71
    • /
    • 2018
  • The comparison of demand and supply is needed for efficient ecosystem services planning. However, the gap between them cannot be analyzed as existing studies mainly dealt with only the supply of ecosystem services. This study compares the demand and supply of ecosystem services in Shiheung using environmental complaints and urban planning by semantic network analysis. As a result, 'air' and 'water' quality are magnified in demand, 'energy' and 'water' are crucial in supply. This result presents that citizen ask for the improvement of air quality in regulation services, although local government has plans for energy support in provisioning services. Periodic ecosystem services demand and supply monitoring will be the base of effective ecosystem services planning, which reduce insufficiency and surplus.

GIS-based PM10 Concentration Real-time Service (GIS기반 PM10 미세먼지농도 실시간 서비스)

  • Yoon, Hoon Joo;Han, Gwang In;Cho, Sung Ho;Jung, Byung hyuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.6
    • /
    • pp.585-592
    • /
    • 2015
  • In this study, by applying mobile based GIS and image analysis of particulate matter ($PM_{10}$) concentration in Seoul and Ulsan in Korea, to identify the user's location and also implemented the application to information exchange. It strengthened citizens' access to air quality information through the application and derived the expanded environment information sharing through real-time user participation. Through atmospheric concentrations image analysis, it showed a new environmental information construction possibility. It had the effect of expanding the information collecting through the local user participation on the limited information collected area which place is not yet constructed atmospheric monitoring network. Location-based particulate matter information service application provides a user location's $PM_{10}$ information from the 25 urban air monitoring network real-time database of the Ministry of Environment. Furthermore, if the user sent a picture of the atmosphere to the server, should match the image density values of the database and express on Seoul's maps through the IDW interpolation. And then a $PM_{10}$ concentration result is transmitted to user in real time.

The Analysis of PM10 Concentration and the Evaluation of Influences by Meteorological Factors in Ambient Air of Daegu Area (대구지역 대기 중 미세먼지의 오염도 분석 및 기상인자에 따른 영향 평가)

  • Hwang, Yoon-Jung;Lee, Soon-Jin;Do, Hwa-Seok;Lee, Yun-Ki;Son, Tae-Jung;Kwon, Taek-Gyu;Han, Jung-Wook;Kang, Dong-Hun;Kim, Jong-Woo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.5
    • /
    • pp.459-471
    • /
    • 2009
  • Air Monitoring Network(11 urban stations) is operated to measure ambient air quality in Daegu city. The urban air monitoring stations include 6 in residence area, 3 in industrial area, 1 in commercial area, and 1 in green area. In this study, hourly data (2006. 1. 1~2008. 12. 31) of $PM_{10}$ were measured at 11 urban air monitoring stations. $PM_{10}$ mean concentrations were high in fall and winter because of low wind speed and many haze days. The number of exceeding the daily standard of $PM_{10}$ in industrial area was approximately twice as many as that in residence area. $PM_{10}$ concentrations and visibility were influenced significantly by wind speed. Wind speed and visibility were below 1.8 m/s and 10 km, respectively when $PM_{10}$ concentrations were over $120{\mu}g/m^3$. $PM_{10}$ concentrations were high when haze was observed. The mean concentrations of $PM_{10}$ were $104{\pm}41.3{\mu}g/m^3$, $63{\pm}35.1{\mu}g/m^3$, and $49{\pm}26.9{\mu}g/m^3$, respectively when haze, mist and clear were observed.