• Title/Summary/Keyword: Urban Heat island effect

Search Result 172, Processing Time 0.022 seconds

Urbanization and Urban Heat Island Analysis Using LANDSAT Imagery: Sejong City As a Case Study (LANDSAT 영상을 이용한 세종특별자치시의 도시화와 열섬현상 분석)

  • Kim, Mi-Kyeong;Kim, Sang-Pil;Kim, Nam-Hoon;Sohn, Hong-Gyoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.1033-1041
    • /
    • 2014
  • Rapid urbanization of Korea was an unprecedented example in the world and urban population increased significantly. As a result, unbalanced distribution of population is serious problem in Korea because approximately 50% of the population is concentrated in the capital area that is 10% of nation's territory, thereby occurring various urban problems including UHI. Hence, Sejong Special Autonomous City was inaugurated officially on 2 July 2012 in order to decentralize population of capital area and induce more balanced regional development. The Sejong City has been changed drastically over a period of years as developed practically since the late 2000's and is expected to have new problems of urbanization. The land cover change due to urbanization is the main cause of UHI that urban area is significantly warmer than its surrounding areas and UHI is not only affecting urban climate change but also natural environment. So the purpose of this research is to analyze level of urbanization and UHI effect and to provide the correlation analysis between Land Surface Temperature and spectral indices. To achieve this, satellite imagery from LANDSAT were used. NDVI, NDBI, and UI were calculated using red, near-infrared, mid-infrared ($0.63{\mu}m-1.75{\mu}m$) images and LST was retrieved utilizing thermal infrared ($10.4{\mu}m-12.5{\mu}m$) image. Based on each index and LST, Changes of NDVI, UI and UHI through TVI were analyzed in Sejong City. UHI effect increased around newly constructed multi-functional administrative city, the correlation between LST and NDVI was negative and UI was strong positive.

Assessment of Regional Climate Change in Urban and Rural Areas Based on Anthropogenic Climate Change and Urbanization (도시화에 따른 도시 및 농촌 지역의 국지적 기후변화 비교 분석)

  • Nam, Won-Ho;Yoon, Dong-Hyun;Hong, Eun-Mi;Kim, Taegon;Baigorria, Guillermo A.
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.25-25
    • /
    • 2017
  • 국지 혹은 지역적인 기후의 특성은 지구규모 또는 종관규모에서의 온실가스 증가로 인한 온난화와 동시에 도시화 (urbanization)에 따른 열섬 현상 (heat island effect)을 포함한 인위적인 요소들이 복합적으로 작용하여 나타날 수 있다. 도시화에 따른 지면피복의 변화는 관측된 온난화 신호에 일정부분 기여하며, 도시 지역은 농촌 및 산림 지역과 비교하여 수문 및 기후학적 측면에서 지역 내 에너지수지 및 물수지의 특성이 상이하기 때문에, 지구온난화에 의한 전 지구적 현상과 도시화에 의한 국소적 현상을 구분하여 파악하는 것은 중요하다. 또한 향후 도시/비도시에 따른 도시화 편향 영향으로 인한 기후변화 예측의 편이를 분석하는데 필수적으로 요구된다. 본 연구에서는 급격한 도시화로 인한 인위적인 기후변화 (anthropogenic climate change)와 종관규모에서의 자연적 기후변화 (natural climate change or climate change)에 기인한 부분을 정량적으로 구분하고자 한다. 이를 위해 도시화의 정도가 서로 다른 도시 지역 및 농촌, 산림 지역을 선정하여 최근 50년간 (1966~2015년) 기상청 관측소의 기상자료와 각 관측지점별 인구수 및 인구증가/감소 추세를 비교함으로써 도시화율의 변화가 기상요소에 미치는 영향의 지역별 차이를 정량적으로 분석하였다.

  • PDF

Assessment of Temperature Reduction and Heat Budget of Extensive Modular Green Roof System (경량모듈형 옥상녹화시스템의 온도저감 및 열수지 평가)

  • Kim, Se-Chang;Park, Bong-Ju
    • Horticultural Science & Technology
    • /
    • v.31 no.4
    • /
    • pp.503-511
    • /
    • 2013
  • The purpose of this study was to evaluate temperature reduction and heat budget of extensive modular green roof planted with Sedum sarmentosum and Zoysia japonica. Plant height and green coverage were measured as plant growth. Temperature, net radiation and evapotranspiration of concrete surface, green roof surface, in-soil and bottom were measured from August 2 to August 3, 2012 (48 hours). On 3 P.M., August 3, 2012, when air temperature was the highest ($34.6^{\circ}C$), concrete surface temperature was highest ($57.5^{\circ}C$), followed by surface temperature of Sedum sarmentosum ($40.1^{\circ}C$) and Zoysia japonica ($38.3^{\circ}C$), which proved temperature reduction effect of green roof. Temperature reduction effect of green roof was also shown inside green roof soil, and bottom of green roof. It was found that Zoysia japonica was more effective in temperature reduction than Sedum sarmentosum. Compared with the case of concrete surface, the highest temperature of green roof surface was observed approximately 2 hours delayed. Plant species, temperature and soil moisture were found to have impact on surface temperature reduction. Plant species, air temperature, soil moisture and green roof surface temperature were found to have impact on temperature reduction in green roof bottom. As results of heat budget analysis, sensible heat was highest on concrete surface and was found to be reduced by green roof. Latent heat flux of Zoysia japonica was higher than that of Sedum sarmentosum, which implied that Zoysia japonica was more effective to improve thermal environment for green roof than Sedum sarmentosum.

Landuse oriented Water Balance Analysis Method by the Hydrological Model BAGLUVA based on Soil and Vegetation (토양-식생기반의 수문모델 BAGLUVA를 적용한 토지이용별 물수지 분석 방법론)

  • Kwon, Kyung Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.98-111
    • /
    • 2015
  • Urban environmental problems such as flooding, depletion of ground water, pollution of urban streams and the heat island effect caused by urban development and climate change can be mitigated by the improvement of the urban water cycle. For the effective planning of water cycle management it is necessary to establish aerial Hydrotope Maps, with which we can estimate the status and change of the water allowance for any site. The structure of the German water balance model BAGLUVA, which is based on soil and vegetation, was analyzed and the input data and boundary condition of the model was compared with Korean data and research results. The BAGLUVA Model consists of 5 Input categories (climate, land use, topography, soil hydrology and irrigation). The structure and interconnection of these categories are analyzed and new concepts and implementation methods of topographic factor, maximum evapotranspiration ratio, effective rooting depth and Bagrov n parameter was compared and analyzed. The relation of real evapotranspiration ($ET_a$)-maximum evapotranspiration ($ET_{max}$) - precipitation (P) was via Bagrov n factor represented. The aerial and land use oriented Hydrotope Map can help us to investigate the water balance of small catchment areas and to set goals for volume of rainwater management and LID facilities effectively in the city. Further, this map is a useful tool for implementing water resource management within landscape and urban planning.

Deducing environmentally conscious factors for apartment complex planning and weight evaluation (환경요소를 고려한 공동주택 단지계획요소 도출 및 가중치 평가)

  • Jung, Suk-Jin;Seo, Jung-Bum;Yoon, Seong-Hwan
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.51-56
    • /
    • 2016
  • Purpose: As declines in the quality of residential environments occur, such as urban heat island effect, tropical night phenomenon, and violations of right to light and privacy due to urban densification and high rise building, these problems are emerging as social issues. In order to improve these issues, design factors which consider environmental aspects must be selected when planning apartment complexes, and ways to reflect them in the planning phase must be explored. Method: In this study, the analytical hierarchy process(AHP) was used to deduce design factors that considered environmental elements during the planning of apartment complexes. Furthermore, the priority and weight for each evaluation index were assessed. The objective was to propose a guideline for planning apartment complexes by finding the best solution for each evaluation index using complex weight values. Result: Floor area ratio was selected as the most important evaluation criterion in the environmentally conscious evaluation index for apartment complex planning. The shape and placement of skylights were selected as the most important evaluation criteria in the sunshine environment for a pleasant residential environment. Ground surface cover design was selected as the most important criterion in the outdoor thermal environment index for improving the microclimate within cities and apartment complexes. Thus, the results of this study can serve as an investigation guideline that concerns policy and regulations, and as reference data that can be used in planning apartment complexes.

The Analysis of Evergreen Tree Area Using UAV-based Vegetation Index (UAV 기반 식생지수를 활용한 상록수 분포면적 분석)

  • Lee, Geun-Sang
    • Journal of Cadastre & Land InformatiX
    • /
    • v.47 no.1
    • /
    • pp.15-26
    • /
    • 2017
  • The decrease of green space according to the urbanization has caused many environmental problems as the destruction of habitat, air pollution, heat island effect. With interest growing in natural view recently, proper management of evergreen tree which is lived even the winter season has been on the rise importantly. This study analyzed the distribution area of evergreen tree using vegetation index based on unmanned aerial vehicle (UAV). Firstly, RGB and NIR+RG camera were loaded in fixed-wing UAV and image mosaic was achieved using GCPs based on Pix4d SW. And normalized differences vegetation index (NDVI) and soil adjusted vegetation index (SAVI) was calculated by band math function from acquired ortho mosaic image. validation points were applied to evaluate accuracy of the distribution of evergreen tree for each range value and analysis showed that kappa coefficient marked the highest as 0.822 and 0.816 respectively in "NDVI > 0.5" and "SAVI > 0.7". The area of evergreen tree in "NDVI > 0.5" and "SAVI > 0.7" was $11,824m^2$ and $15,648m^2$ respectively, that was ratio of 4.8% and 6.3% compared to total area. It was judged that UAV could supply the latest and high resolution information to vegetation works as urban environment, air pollution, climate change, and heat island effect.

A field Study to Evaluate Cooling Effects of Green Facade under Different Irrigation Conditions - Focusing on modular green facade planted with Hedera helix L and Pachysandra terminalis - (관수조절에 의한 벽면녹화의 냉각효과 분석 연구- 아이비, 수호초를 식재한 모듈형 벽면녹화를 중심으로-)

  • Kim, Eun-Sub;Yun, Seok-Hwan;Piao, Zheng-gang;Jeon, Yoon-Ho;Kang, Hye-Won;Kim, Sang-Hyuck;Kim, Ji-Yeon;Lee, Young-Gu;Lee, Dong-Kun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.6
    • /
    • pp.121-132
    • /
    • 2021
  • Green facade has a significant impact on building's energy performance by controlling the absorption of solar radiation and improving outdoor thermal comfort through shading and evapotranspiration. In particular, since high-density building does not enough green space, green facade, and rooftop greening using artificial ground plants are highly utilized. However, the level of cooling effect according to plant traits and irrigation control is different. Therefore, in this study, the cooling effect analyzed for a total of 4 cases by controlling the irrigation condition based on hedera and spurge. Although hedera under sufficient water had the highest cooling effect(-2℃~-4℃), had the lowest cooling effect under non-irrigation(+1.1℃~+4.4℃). In addition, hedera under sufficient water had cooling effect than hedera under non-irrigation(-1℃~-8.1℃) and in the case of spurge, it had cooling effect(-0.3℃~-7.8℃) more than non-irrigation. As a result of measuring the amount of transpiration according to the light intensity (PAR) and carbon dioxide concentration conditions, transpiration of hedera was higher than the spurge (respectively 0.63204mmolm-2s-1, 0.674367mmolm-2s-1). The difference in the cooling effect of the green facade under irrigation condition was significant. But the potential cooling effect of green facade according to plants species was different. Therefore, in order to maximize and continuously provide the cooling effect of green facade in urban areas, it is necessary to consider the characteristics of plants and the control of water supply through the irrigation system.

Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof (쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과)

  • Song, Bong-Geun;Kim, Gyeong-Ah;Park, Kyung-Hun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

Urbanization Effect on the Observed Warming in Korea during the Recent Half Century (우리나라의 기온상승-도시효과인가 지구온난화인가)

  • 윤진일
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.4 no.1
    • /
    • pp.58-63
    • /
    • 2002
  • Since the rapid urbanization period coincides with the start of global warming, climate data might be contaminated with urbanization effect in Korea. Monthly normals of daily minimum, maximum, and mean temperature of 14 stations were calculated for 1951-1980 and 1971-2000 periods. Differences in two temperature normals were regressed to the natural logarithms of population increase at corresponding 14 cities from 1966 to 1990. The regression models were used to remove potential effects of urbanization from the apparent warming, and to determine the net contribution of global warming to the temperature change in Korea during the recent half century. According to the model calculation, there was little evidence of global warming in the warm season (May through November), while urbanization effect was common in all season except April. Up to 0.5$^{\circ}C$ warming of nighttime temperature was found to be induced by urbanization. Cool season temperature was increased by up to 0.6$^{\circ}C$ due mainly to the global warming of daytime temperature.

Assessment of Temperature Reduction and Evapotranspiration of Green Roof Planted with Zoysia japonica (한국잔디식재 옥상녹화의 온도저감 및 증발산량 평가)

  • Kim, Se-Chang;Lee, Hyun-Jeong;Park, Bong-Ju
    • Journal of Environmental Science International
    • /
    • v.22 no.11
    • /
    • pp.1443-1449
    • /
    • 2013
  • This was an experimental study to evaluate temperature reduction and evapotranspiration of extensive green roof. Three test cells with a dimension of $1.2(W){\times}1.2(D){\times}1.0(H)$ meters were built using 4-inch concrete blocks. Ten-centimeter concrete slab was installed on top of each cell. The first cell was control cell with no green roof installed. The second and third cells were covered with medium-leaf type Zoysiagrass (Zoysia japonica) above a layer of soil. Soil thickness on the second cell was 10cm and that on the third cell was 20cm. Air temperature, relative humidity and solar irradiance were measured using AWS (automatic weather system). Temperature on top surface and ceiling of the control cell and temperature on top surface, below soil and ceiling of green roof cells was measured. Evapotranspiration of the green roof cells were measured using weight changes. Compared with temperature difference on the control cell, temperature difference was greater on green roof cells. Between two green roof cells, the temperature difference was greater on the third cell with a thicker soil layer. Temperature differences below soil and on ceilings of green roof cells were found greater than those of the control cell. Between the green roof cells, there was no difference in the temperature reduction effects below soil and on ceilings based on substrate depth. In summary, green roof was found effective in temperature reduction due to evapotranspiration and shading effect.