• Title/Summary/Keyword: Uranyl ion sensor

Search Result 4, Processing Time 0.022 seconds

Salphen H2 as a Neutral Carrier for the Uranyl Ion-Selective PVC Membrane Sensor

  • Kim, Dong-Wan;Park, Kyeong-Won;Yang, Mi-Hyi;Kim, Jin-eun;Lee, Shim-Sung;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.899-902
    • /
    • 2006
  • The complexation of N,N'-4,5-(ethylenedioxy)benzenebis(salicylideneimine), (salphen$H_2$) with uranyl ion was studied in acetonitrile solution spectrophtometrically, and the formation constant of the resulting 1 : 1 complex was evaluated. The salphen$H_2$ ligand was used as an ionophore in plasticized poly(vinyl chloride) (PVC) matrix membrane sensor for uranyl ion. The prepared sensors exhibited a near Nernstian response, 28.0-30.9 mV/decade for uranyl ion over the concentration range $1.0\;{\times}\;10^{-2}$ to $1.0\;{\times}\;10^{-6}$M with a limit of detection of $3.2\;{\times}\;10^{-7}$ M. The proposed electrode could be used at a working pH range of 1.5 - 4.0.

Fabrication and pH response characteristics of LAPS(Light addressable potentiometric sensor) with electrolyte/$Si_3N_4/SiO_2$/Si structure (Electrolyte/$Si_3N_4/SiO_2/Si$ 구조의 LAPS 제작 및 pH 응답특성)

  • Chang Su-Won;Koh Kwang-Nak;Kang Shin-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.40-44
    • /
    • 1998
  • The LAPS device of fast response and high sensitivity, based on electrochemical potential difference, and its system were fabricated for the precise measurement of pH changes and its characteristic were investigated. The electrostatic variation characteristics of LAPS according to the pH changes and parameters in the device were verified through a simulation using LAPS equivalent circuit model. The LAPS device and its system were fabricated on the basis of the result of simulation. The fabricated LAPS system showed linear sensitivity (about 56 mV/pH within the range of pH 2 to pH 11. In order to overcome the defect of general urea sensor (especially slow response time), urease immobilized nitrocellulose membrane was attached on the LAPS and resulted in the very fast response time, 0.29 mV/sec, 0.86 mV/sec at urea concentration of $50{\mu}g/ml,\; 500{\mu}g/ml$, respectively. And also in order to measure the uranyl ion, the uranyl ion selective sensing membrane with calix[6]arene derivative was used and its sensitivity was 25mV/concentration decade in the wide uranyl ion concentration range of $10^{-11}M\;to\;10^{-4}M$.

Beryllium(II) Recognition by Allosteric Effects in 1,2-Ethylenedioxybenzene Based Ditopic Receptors

  • Kim, Dong-Wan;Kim, Jung-Hwan;Hwang, Jae-Young;Choi, Myong-Yong;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2643-2647
    • /
    • 2011
  • Efficient ditopic receptor, uranyl(II) N,N'-(ethylenedioxy)benzenebis(salicylideneimine) (3) for beryllium ion has been obtained upon functionalization of 1,2-ethylenedioxybenzene (1) with a uranyl-salphen (salphen = N,N'-phenylenebis(salicylideneimine)) unit. Binding affinities of the receptor, 3 in AN-DMSO (v/v 95:5) solution have been measured for alkali and alkaline earth metal ions by conductometry comparing 1. The results showed that both monotopic 1 and ditopic receptor 3 were selective for $Be^{2+}$ ions over other cations, while especially 3 that can complex both with cations (coordinated to basic oxygen of ethylenedioxybenzene) and anions (coordinated to the Lewis acidic uranyl center) results in an increase of the stability constants by a factor of $10^{2.42}$ with respect to 1. Furthermore, the $Be^{2+}$-3 interactions are demonstrated by $^1H$ NMR experiments in highly polar solvent medium, DMSO-$d_6$. Higher selectivities were also observed for $Be^{2+}$ when the ditopic receptor, 3 was incorporated into PVC membranes and tested as ion selective electrodes at neutral pH.

UO22+ Ion-Selective Membrane Electrode Based on a Naphthol-Derivative Schiff's Base 2,2'-[1,2-Ethandiyl bis(nitriloethylidene)]bis(1-naphthalene)

  • Shamsipur, Mojtaba;Saeidi, Mahboubeh;Yari, Abdullah;Yaganeh-Faal, Ali;Mashhadizadeh, Mohammad Hossein;Azimi, Gholamhasan;Naeimi, Hossein;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.5
    • /
    • pp.629-633
    • /
    • 2004
  • A new PVC membrane electrode for $UO_2^{2+}$ ion based on 2,2'-[1,2-ethanediyl bis (nitriloethylidene)]bis(1-naphthalene) as a suitable ionophore was prepared. The electrode exhibites a Nernstian response for $UO_2^{2+}$ ion over a wide concentration range ($1.0{\times}10^{-1}-1.0{\times}10^{-7}$M) with a slope of 28.5 ${\pm}$ 0.8 mV/decade. The limit of detection is $7.0{\times}10^{-8}$M. The electrode has a response time of < 20 s and a useful working pH range of 3-4. The proposed membrane sensor shows good discriminating abilities towards $UO_2^{2+}$ ion with regard to several alkali, alkaline earth transition and heavy metal ions. It was successfully used to the recovery of uranyl ion from, tap water and, as an indicator electrode, in potentiometric titration of $UO_2^{2+}$ ion with Piroxycam.