• Title/Summary/Keyword: Ups

Search Result 1,693, Processing Time 0.029 seconds

Industry Structure, Technology Characteristics, Technology Marketing and Performance of Technology -Based Start-ups: With Focus on Technology Marketing Strategy (기술창업의 산업구조 기술특성 및 기술마케팅전략이 창업성과에 미치는 영향: 기술마케팅 전략 유형 조절변수)

  • Han, Sang-Seol
    • Journal of Distribution Science
    • /
    • v.14 no.2
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose - This study aims to advance our knowledge about factors influencing technical startup performance through analysing technical startup process empirically. This study was conducted to focus on industry structure(industry growth rate, competitive intensity, and enter barriers), technology characteristics(technical excellence and wide range of technical application), and the performance in the technology-based start-ups. Specifically, analyzing moderating effect of technology-marketing strategy, this studied how moderating variables affect technical startup performance under industry structure. Research design, data, and methodology - The subject of this study was technology-based start-ups company that received technology transfer from public organization. The development of the paper model is based on the literature of the preceding research analysis in technology commercialization, performance of technology-based start-ups, and marketing strategy. This study has a construct that was defined in the previous studies, such that technology marketing strategy was defined into the two ways of being broad or narrow in strategic application. From November 3. 2015 to December 22, 220 questionnaires were distributed with targeting to start-up companies in technology-based. 188 responses were collected for empirical analysis except the missing and wrong value responses. This data were used for structural equation modeling and regression analysis. Results - The results of this study are as follows. First, as industry structure variables influencing on performance(technical, financial) of technology-based start-ups, industry growth rate, competitive intensity and enter barriers of variables were verified; high growth rate has more positive effect on performance than low growth rate, competitive low intensity has more positive effect on performance than competitive high intensity, low enter barriers have more positive effect on performance than high enter barriers. Second, as technology characteristics variables influences on the performance(technical, financial) of technology-based start-ups, technical excellence and wide range of technical application of variables were verified ; technical high-excellence has more positive effect on performance than technology low-excellence, wide range of technical application has more positive effect on performance than narrow range of technical application. We also find that technology marketing strategy(broad/narrow) in moderating factors on performance (technical, financial) is as follows. Analyzing the moderating effect depending on technology marketing strategy(broad/narrow), application of technology, and the types of technology strategy(broad/narrow) were revealed that broad marketing strategy had a more significant effect on performance of technology-based start-ups. With AMOS, the relevancy of the study model revealed higher for broad technology-marketing strategy than narrow technology marketing strategy, and the explanatory power revealed to be 6.4% higher in broad marketing strategy than narrow marketing strategy. Conclusions - This study confirmed that industry structure and technology characteristics are important factors influencing the performance of technology-based start-ups. Technology-marketing strategy affects the performance of technology-based start-ups between industry structure and technology characteristics. According to additional analysis, moderating variables and technology-marketing strategy are important factors influencing the performance of technology-based start-ups under industry structure and technology characteristics. Broad type of technology-marketing strategy has more attractive industry structure and excellent technology characteristics than narrow types of technology-marketing.

The Effect of Location Satisfaction of Innovative Start-ups on the Intention of Relocation: Focusing on Capital and Non-Capital Areas (혁신형 창업기업의 입지 만족도가 기업 이전 의도에 미치는 영향: 수도권과 비수도권 기업을 중심으로)

  • Choi, Jongmin
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.16 no.6
    • /
    • pp.57-68
    • /
    • 2021
  • The purpose of this study is to investigate the effect of location satisfaction of innovative start-ups, located in capital and non-capital areas, on the intention of relocation. The analysis was based on the data of a survey of 231 innovative start-ups that were founded less than 7 years ago. 10 factors related to the aspects of business management, network building, and business environment were considered as location satisfaction of start-ups. The dependent variable was whether innovative start-ups plan to relocate. First, it was confirmed that in the case of innovative start-ups in capital area, the intention to relocate was found to decrease when the location satisfactions related to the promptly provision of products and services to consumers and ease of supplying labor were increased. Second, in the case of innovative start-ups in non-capital area, it was found that the intention to relocate was found to decrease when the location satisfactions related to creating a network, convenient transportation and free and creative start-up environment were increased. In addition, it was found that the higher the sales of start-ups in non-capital area, the lower their intention to relocate while the higher firm age of start-ups in non-capital area, the higher their intention to relocate. This study has an academic contribution to examining the relationship between between the location satisfactions of start-ups and the intention to relocate, which has been rarely addressed in Korea, and to shedding light on the difference in capital and non-capital areas. Furthermore, this study has policy implications since it suggests factors that the government should consider for geographical agglomeration of start-ups.

Accessibility Factors to Health Check-Ups for People with Disability: A Qualitative Study (장애인 건강검진 접근성 저해요인과 개선방안 도출에 대한 질적 연구)

  • Hong, Hye-Su;Lim, Myung Joon;Kim, Oi-Sook;Choi, Eun-Sook;Kim, Jung Hwan
    • Health Policy and Management
    • /
    • v.30 no.3
    • /
    • pp.335-344
    • /
    • 2020
  • Background: The purpose of this study was to identify factors inhibiting access of people with disability to health check-ups as well as identify pertinent solutions for improvement. Methods: Twenty-three people with disability older than the age of 19 who took respective health check-ups within the last 3 years were selected as participants. For the data collection, the 1:1 intensive interview was used. The data were analyzed by the grounded theory by Corbin and Strauss. Results: The results comprised nine categories, 23 subcategories, and 179 concepts. The central phenomenon was 'failure to obtain check-ups.' Causal conditions were observed as a 'lack of communication method,' 'physical difficulties,' and 'staff unfamiliar with people with disability,' Interventional conditions comprised 'physical accessibility,' 'staffs' competency,' and 'assistant manpower.' The active strategy was included 'to investigate the professional medical institution,' 'to find the medical institution of convenient traffic accessibility,' 'to overcome communication difficulties through equipment,' and 'to overcome linguistic barriers through sufficient communication.' Whereas, 'utilization of ancillary equipment,' 'the education of staffs on people with disability,' 'universal design manual,' and 'customized check-ups' were included in the passive strategy. Such processes arose in the contextual conditions of 'lack of expectations for daily lives' and 'lack of government support.' As a consequence, the subjects participated experienced the 'disadvantages,' 'discrimination,' and 'reduced reliability of the health check-ups.' Conclusion: The subjects who participated in this study emphasized 'staffs familiar with people with disability' and 'systems customized for people with disability' are mandatory to secure complete health check-ups for people with disability.

A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator (새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구)

  • Kwak, A-Rim;Park, Seong-Mi;Son, Gyung-Jong;Park, Sung-Jun;Kim, Jong-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

New established cell lines from undifferentiated pleomorphic sarcoma for in vivo study

  • Eun-Young Lee;Young-Ho Kim;Md Abu Rayhan;Hyun Guy Kang;June Hyuk Kim;Jong Woong Park;Seog-Yun Park;So Hee Lee;Hye Jin You
    • BMB Reports
    • /
    • v.56 no.4
    • /
    • pp.258-264
    • /
    • 2023
  • As a high-grade soft-tissue sarcoma (STS), undifferentiated pleomorphic sarcoma (UPS) is highly recurrent and malignant. UPS is categorized as a tumor of uncertain differentiation and has few options for treatment due to its lack of targetable genetic alterations. There are also few cell lines that provide a representative model for UPS, leading to a dearth of experimental research. Here, we established and characterized new cell lines derived from two recurrent UPS tissues. Cells were obtained from UPS tissues by mincing, followed by extraction or dissociation using enzymes and culture in a standard culture environment. Cells were maintained for several months without artificial treatment, and some cell clones were found to be tumorigenic in an immunodeficient mouse model. Interestingly, some cells formed tumors in vivo when injected after aggregation in a non-adherent culture system for 24 h. The tissues from in vivo study and tissues from patients shared common histological characteristics. Pathways related to the cell cycle, such as DNA replication, were enriched in both cell clones. Pathways related to cell-cell adhesion and cell-cell signaling were also enriched, suggesting a role of the mesenchymal-to-epithelial transition for tumorigenicity in vivo. These new UPS cell lines may facilitate research to identify therapeutic strategies for UPS.

Development of UPS System Embedded in Computer Power Supply Using GUI (GUI를 이용한 컴퓨터 Power Supply 내장형 UPS 시스템의 개발)

  • Roh, Inh-Bae;Park, Jee-Ho;Hwang, Gi-Hyun;Kim, Dong-Wan;Woo, Jung-In
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.4
    • /
    • pp.190-194
    • /
    • 2004
  • In this paper, UPS, which is embedded in computer power supply, is developed against the poor utility power system. In the developed system, PIC16C54 is used as the main controller, and UPS system consists of micom control module, power failure detecting module, charging module, power module, synchronous transfer module, and GUI module. Additionally, GUI module consists of battery charging state unit, power operating unit and operating state unit. The effectiveness of the developed system has been verified by the experimental results.

A Modular UPS Design with an Active Multiple Interphase Reactor and Double PLL Control (능동 다중인터페이스 리액터와 Double PLL제어를 이용한 Modular UPS 설계)

  • 박인덕;정상식;안형회;김시경
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.489-497
    • /
    • 2001
  • The proposed dobule phase locked loop and active multiple interphase reactor are used to eliminate the circular current and the voltage ripples caused by the system parameter unbalance of parallel connected UPSs. In this paper, digital controller for the dobule PLL and active interphase reactor is implemented with ADSP21061 as an aspect of functional convenience.

  • PDF

A PFC Controller Design for 3-Phase Modular UPS (3상 모듈형 UPS용 PFC 제어기 설계)

  • Kim, Sang-Hoon;Park, Nae-Chun
    • Journal of Industrial Technology
    • /
    • v.31 no.B
    • /
    • pp.75-79
    • /
    • 2011
  • In this paper a new PFC Controller for 3-Phase Modular UPS(Uninterruptible Power Supplies) is proposed. The PFC circuit for 3-Phase Modular UPS is implemented using three 1-phase 3-level boost PFC circuits. To control DC output voltage, single voltage controller considering imbalance of two capacitor voltages and to regulate AC input current three independent current controllers are used in proposed PFC controller. By the proposed method, without additional hardware, THD(Total Harmonic Distortion) of input currents can be readily limited below 5% which is the harmonic current requirements by IEEE std. 519. Its validity is verified by simulations and experiments.

  • PDF

Performance Analysis of Free-Style Writing and Drawing using Ultrasonic Position System

  • Shin, Low-Kok;Park, Soo-Hong
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.1
    • /
    • pp.6-9
    • /
    • 2008
  • In future domestic context aware applications the location of mobile devices is often required. Ultrasonic technology enables high resolution indoor position measurements. A disadvantage of state-of-art ultrasonic systems is that several base stations are required to estimate 3D position. This study aims to evaluate the efficiency and effectiveness of using UPS as a 3D free-hand writing or drawing tool. The processes include the design and testing of UPS as an efficient 3D free-hand writing or drawing tool in the air. The paper will further explain the system architecture of the UPS and how to use GPS as 3D free-hand writing or drawing tool. The efficiency and effectiveness of the system was confirmed by a computer software simulation. The software will further display the result of drawing or writing from the user by graphics. As a result, it is possible to implement UPS as a 3D free-hand writing or drawing tool in the air.

Reduction of Current Harmonic Occurred form between Uninterruptible Powers Supply and Rectifier Load (정류기 부하와 무정전전원장치 사이에 발생되는 Current Harmonic 저감)

  • 곽철훈;반한식;최규하;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.41-44
    • /
    • 1999
  • The main purpose of the UPS is to supply independent and stable power to connected equipment. In installing and operating the UPS system, songle module, three phase UPS in more benefit than multi module, songle phase UPS in the point of volume and cost. However, when supplying Rectifier with output power form three phase UPS, by connecting auto-transformer, occurred harmonic and ripple current makes output filter damaged and leads to nonlinear current coasted by unbalance load. Therefor, in this paper the aim of concentring compound-wound transformer and harmonic filter is supplying liner current by reducing harmonic and ripple current and improving unbalance in voltage and distortion in current wave.

  • PDF