• 제목/요약/키워드: Upper electrode

검색결과 155건 처리시간 0.029초

생체임피던스에 의한 상지운동 감지를 위한 최적 전극 위치의 평가 및 검증 (Evaluation and Verification of Optimal Electrode Configurations for Detection of Arm Movement Using Bio-Impedance)

  • 안선희;김수찬;남기창;김덕원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.399-402
    • /
    • 2002
  • In this study, we constructed a four-channel impedance measurement system including a two-channel goniometer to analyze human arm movement. Impedances and joint angles were simultaneously measured for wrist and elbow movements. As the impedance changes resulting from wrist and elbow movements depended heavily on electrode placement, we determined the optimal electrode configurations for those movements by searching for high correlation coefficients, large impedance changes, and minimum interferences in ten subjects (age: 29+6). Our optimal electrode configurations showed very strong relationships between the wrist joint angle and forearm impedance (correlation coefficient = 0.95+0.04), and between the elbow joint angle and upper arm impedance (correlation coefficient = -0.98+0.02). Although the measured impedances changes of the wrist (1.1+1.5 ohm) and elbow (-5.0+2.9 ohm) varied among individuals, the reproducibilities of wrist and elbow impedance changes of five subjects were 5.8+1.8 % and 4.6+1.4 % for the optimal electrode pairs, respectively. We propose that this optimal electrode configuration would be useful for future studies involving the measurement of accurate arm movements by impedance method.

  • PDF

Analysis on the Change of Hand Grip Strength as per the Circumference of Upper Arm and Forearm and the Muscle Activity of Upper Arm and Forearm as per the Duration of Gripping

  • Jeong, Yoo Ahn;Min, Ji Hee;Yun, Young Dae;Choi, Jung Hyun;Yoo, Kyung Tae
    • 국제물리치료학회지
    • /
    • 제4권1호
    • /
    • pp.532-538
    • /
    • 2013
  • The purpose of this study is to analyze the grip strength by the girth of upper arm and forearm and their muscle activities by duration of grip strength. The subjects were consisted of 20 healthy adults(10 males & 10 females) who had no medical history of neurological and surgical problems with their arms. Girth of upper arm/ forearm and maximum grip strength for 4sec and 30sec were measured. Muscle activity was by wireless electrode EMG system. Co-relation of girth of upper arm/ forearm was significantly high. Upper arm's muscle activity performed for 4sec and 30sec was significantly high. In this study. It suggests that training of upper arm should be performed with the training of grip strength because both of upper arm and forearm affected grip strength.

캘릭스[4]크라운 유도체를 이온선택성 물질로 사용한 납이온 선택성 막전극 (Lead Ion-Selective Electrode Based on Upper-rim Calix[4]crown Ionophore)

  • 남궁미옥;임혜재;백경수;윤영자
    • 대한화학회지
    • /
    • 제44권2호
    • /
    • pp.115-119
    • /
    • 2000
  • 새로운 캘릭스[4] 크라운 화합물을 이온 선택성 물질로 사용하고 지지체로 PVC(poly(vinylchloride)), 가소제로 DOS(Dioctyl sebacate}를 사용하여 막전극을 제작 하였다. 제작한 막전극을 지시전극으로 사용하여 알칼리, 알칼리토금속 이온 그리고 전이금속 이온에 대하여 각각의 감응전위를 측정한 결과, $10^{-6}{\sim}10^{-2}M\;Pb(NO_3)_2$ 용액에서 $Pb^{2+}$이온의 감응전위가 이론적인 Nernstian식 기울기에 가까운 27.0 mV/decade로 직선성이 잘 성립하는 감응전위를 나타내었다. $Pb^{2+}$ 이온 농도변화에 따른 막의 감응시간은 $t_{90}$=10 sec 이었고, 막의 사용기간은 2개월 정도이다. 또한 pH 영향을 조사해 본 결과 pH $2.0{\sim}12$ 범위에서 감응전위 값이 일정하게 유지되었다.

  • PDF

전극재에 의한 실리콘 고무의 C-V 특성에 관한 연구 (A Study on Properties of C-V of Silicone Rubber due to Electrode Materials)

  • 이성일
    • 한국전기전자재료학회논문지
    • /
    • 제28권11호
    • /
    • pp.721-726
    • /
    • 2015
  • In this study, the properties of C-V degradation for thermal conductivity silicone rubber sample which is attached by copper-copper, copper-aluminum, aluminum-aluminum on upper-side and under-side has been measured at temperature of $80^{\circ}C{\sim}140^{\circ}C$. The results of this study are as follows. In case the frequency is increased, it found that the electrostatic capacity increased with increasing temperature to $80^{\circ}C$, $110^{\circ}C$, $140^{\circ}C$ regardless of kind of electrode. It found that the electrostatic capacity increased with becoming high temperature range of frequency regardless of kind of electrode. This result is considered to be caused by thermal absorption on the thermal conductivity silicone rubber sample. It found that the electrostatic capacity decreased with increasing temperature and frequency. This result is considered to be caused by molecular motion of C-F radical or OH radical.

Effects of Sealing Time of Anodic Aluminum Oxide (AAO) for Upper Electrode of Etcher

  • 송제범;신재수;신용현;강상우;김진태;윤주영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.115-115
    • /
    • 2012
  • 반도체/디스플레이 산업분야의 발전으로 진공 공정 기술력 또한 증진되고 있다. 반도체소자의 초미세화, 진공부품의 대면적화가 진행 되면서 진공 공정 중에 발생하는 오염입자를 제어하는 것이 이슈가 되고 있다. 오염입자는 플라즈마의 물리적인 부식과 활성이 높은 화학반응에 의해 진공부품에서 부식이 진행되어 발생하며, 이는 반도체 및 디스플레이 부품의 신뢰성측면과 수율저하 등 life time의 근본적인 문제점으로 대두되고 있다. 본 연구에서는 반도체/디스플레이 장비용 코팅부품으로 많이 사용되고 있는 Al2O3 코팅막을 이용하였으며, sealing time에 따른 Anodic Aluminum Oxide (AAO) electrode의 물성특성평가 및 진공평가기술을 이용하여 life time을 예측하는 연구를 수행하였다.

  • PDF

선형 저밀도 폴리에틸렌과 에틸렌 비닐아세테이트의 혼합비에 따른 체적고유저항 특성 (The Volume Resistivity Properties due to Mixture ratio of Linear Low Density Polyethylene and Ethylene Vinyl Acetate)

  • 박정구;육영수;신현택;신종열;이충호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.552-555
    • /
    • 1999
  • In this paper, the volume resistivity properties due to mixture ration of linear low density polyethylene(LLDPE) and ethylene vinyl acetate(EVA) are studied. Electrodes is composed of upper electrode 37(mm $\Phi$), guardring electrode(inner 55(mm $\Phi$ ), and lower electrode 87(mm $\Phi$ In order to measure the leakage current, We used electrometer and stable oven with temperature controller. Measurement method is to measure the leakage current of next specimen after applying the voltage according to 'Step Apply Methods' for ten minutes. In order to measure the volume resistivity properties, the micro electrometer is used, the range of temperature and applying voltage are 25 to 100[$^{\circ}C$] to 100[V] respectively.

  • PDF

펄스 전기장에 의한 $Pb(Zr_xTi_{1-x})O_3$ 강유전체의 전자 방출 (Electron Emission from $Pb(Zr_xTi_{1-x})O_3$ Ferroelectrics by Pulsed Electric Field)

  • 김용태;윤기현;김태희;박경봉;곽상희
    • 한국세라믹학회지
    • /
    • 제37권1호
    • /
    • pp.6-11
    • /
    • 2000
  • Electron emission from the Pb(ZrxTi1-x)O3 ferroelectrics by pulsed electric field has been investigated as a function of Zr/Ti ratios such as 35/65, 50/50 and 65/35 below 250kV/cm. Electrons were emitted regardless of the applied field polarity to the rear electrode. When the negative field was applied to the rear electrode, the electron emission charge was more stable. It was proved that the electrons were emitted at the edge of the upper electrode. The emission charge increased in order of 65/35>50/50>35/65. The electron emission characteristics were dependent on the ferroelectric properties such as polarization and coercive field. The emission charge and emission threshold field were affected by the polarization change and the coercive field, respectively. This result explains that the electron emission is a field emission with polarization induced surface potential by a modified Fowler-Nordheim plot of emission charge.

  • PDF

전동의수용 근전위 센서 설계 (Design of myoelectrical sensor for myoelectric hand prosthesis)

  • 최기원;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.247-249
    • /
    • 2007
  • This paper proposes a dry-type surface myoelectric sensor for the myoelectric hand prosthesis. The designed surface myoelectric sensor is composed of skin interface and processing circuits. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. Considering the conduction velocity and the median frequency of the myoelectric signal, the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22mm is selected. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60㎐ power-line noise, amplifier, and a level circuit. Using SUS440, six prototype skin interface with different reference electrode shape and IED is fabricated, and their output characteristics are evaluated by output signal obtained from the forearm of a healthy subject. The experimental results show that the skin interface with parallel bar shape and the 18mm IED has a good output characteristics. The fabricated dry-type surface myoelectric sensor is evaluated for the upper-limb amputee.

  • PDF

정전기력 방식의 Drop-on-Demand 토출을 위한 MEMS 잉크젯헤드 제작 (Fabrication of MEMS Inkjet Head for Drop-on-Demand Ejection of Electrostatic Force Method)

  • 손상욱;김영민;최재용;고한서;김용재;변도영;이석한
    • 전기학회논문지
    • /
    • 제56권8호
    • /
    • pp.1441-1444
    • /
    • 2007
  • This paper presents a novel electrostatic drop-an-demand ejector with a conductive pole inside nozzle. The MEMS fabricated pole-type nozzle shows a significant improvement in the performance and reliability of forming meniscus and generating a micro dripping mode of droplet out of the meniscus. It is verified experimentally that the use of the pole-type nozzle. The liquid is used D20+SDS+SWNT (5 %wt). The gap between upper electrode and nozzle is about 600 um. Electrostatic drop-an-demand ejection is observed when a DC voltage of 1.5 kV is applied between the control electrode and ground electrode. Droplet diameter is $100{\mu}m$.

폴리이미드 용량형 습도센서의 전극 패턴에 따른 감습 특성 (Humidity Sensitive Characterization by Electrode Pattern on the Capacitive Humidity Sensor Using Polyimide)

  • 박성백;신훈규;임준우;장상목;권영수
    • 한국전기전자재료학회논문지
    • /
    • 제27권9호
    • /
    • pp.566-570
    • /
    • 2014
  • Electrode pattern effects on the capacitive humidity sensor were investigated. The fabrication of the capacitive humidity sensor was formed with three steps. The bottom electrode was formed on the silicon substrate with Pt/Ti thin layer by using shadow mask and e-beam evaporator. The photo sensitive polyimide was formed on the bottom electrode by using photolithography process as a humidity sensitive thin film. The upper electrode was formed on the polyimide thin film with Pt/Ti thin layer by using e-beam evaporator and lift-off method. Three electrode patterns, such as circle, square, and triangle pattern, were used and changed the sizes to investigate the effects. The capacitances of the sensors were decreased 622 to 584 pF with the area decreament of patterns 250,000 to $196,250{\mu}m^2$. From these results, a capacitive humidity sensor with photo sensitive polyimide is expected to be applied to a high sensitive humidity sensor.