• Title/Summary/Keyword: Upper electrode

Search Result 155, Processing Time 0.032 seconds

A unit pixel drive and field emission characteristics of oxidized porous polysilicon field emission display (산화된 다공질 폴리실리콘 전계방출 소자의 픽셀별 구동 및 특성)

  • You, Sung-Won;Kim, Jin-Eui;Choi, Sie-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.8-15
    • /
    • 2007
  • In this paper, we fabricated the field emitter display using oxidized porous polysilicon(OPPS). Their field emission characteristics and the brightness were investigated for each pixel. The OPPS emitter was operated to each pixel using passive matrix for application of large panel display. We set up the proper thickness and width of upper electrode. The fine structure of OPPS was analyzed and the field emission characteristics of each pixel were investigated. As a result of field emission characteristics of different upper electrode thickness and width, we confirmed that the most efficient thickness was 2nm/7nm and increased the emission efficiency over the width of 2.5 mm. Even if field emission characteristics of each pixel was a little different but we confirmed the same leakage current and emission current, emission efficiency at each pixel. The leakage current and emission current was decreased according to the time increases but all of each pixel were uniformly decreased. We confirmed that the brightness of each pixel was not different and the brightness of OPPS field emitter was 700 cd/m2 at the Vps=20 V. Accordingly, the patterned OPPS field emitter can be applied to high quality field emission display devices.

Unified solutions for piezoelectric bilayer cantilevers and solution modifications

  • Wang, Xianfeng;Shi, Zhifei
    • Smart Structures and Systems
    • /
    • v.16 no.5
    • /
    • pp.759-780
    • /
    • 2015
  • Based on the theory of piezoelasticity, the static performance of a piezoelectric bilayer cantilever fully covered with electrodes on the upper and lower surfaces is studied. Three models are considered, i.e., the sensor model, the driving displacement model and the blocking force model. By establishing suitable boundary conditions and proposing an appropriate Airy stress function, the exact solutions for piezoelectric bilayer cantilevers are obtained, and the effect of ambient thermal excitation is taken into account. Since the layer thicknesses and material parameters are distinguished in different layers, this paper gives unified solutions for composite piezoelectric bilayer cantilevers including piezoelectric bimorph and piezoelectric heterogeneous bimorph, etc. For some special cases, the simplifications of the present results are compared with other solutions given by other researches based on one-dimensional constitutive equations, and some amendments have been found. The present investigation shows: (1) for a PZT-4 piezoelectric bimorph, the amendments of tip deflections induced by an end shear force, an end moment or an external voltage are about 19.59%, 23.72% and 7.21%, respectively; (2) for a PZT-4-Al piezoelectric heterogeneous bimorph with constant layer thicknesses, the amendments of tip deflections induced by an end shear force, an end moment or an external voltage are 9.85%, 11.78% and 4.07%, respectively, and the amendments of the electrode charges induced by an end shear force or an end moment are both 1.04%; (3) for a PZT-4-Al piezoelectric heterogeneous bimorph with different layer thicknesses, the maximum amendment of tip deflection approaches 23.72%, and the maximum amendment of electrode charge approaches 31.09%. The present solutions can be used to optimize bilayer devices, and the Airy stress function can be used to study other piezoelectric cantilevers including multi-layered piezoelectric cantilevers under corresponding loads.

Fabrication of CO2 Sensor Membrane by Photolithographic Method (사진식각법을 이용한 CO2 센서 감지막의 제조)

  • Park, Lee Soon;Kim, Sang Tae;Koh, Kwang-Nak
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.6-12
    • /
    • 1998
  • A FET(Field Effect Transistor) type dissolved $CO_2$ sensor based on Severinghaus type $CO_2$ sensor was fabricated by the photolithographic process. The sensor consists of Ag/AgCl reference electrode and membranes (hydrogel membrane and $CO_2$ gas permeable membrane) on the pH-ISFET base chip. Ag/AgCl reference electrode was fabricated as follows. Ag layer was thermally evaporated and then its upper surface was chemically chloridized into the AgCl. The hydrogel used as an internal electrolyte solution was fabricated by a photolithographic method using 2-hydroxyethyl methacrylate(HEMA) and acrylamide. $CO_2$ permeable membrane on the top of the hydrogel layer was formed by photolithographic process with UV-oligomer. The FET type $pCO_2$ sensor fabricated by photolithographic method showed good linearity within the concentration range of $10^{-3}{\sim}10^0mole/{\ell}$ of dissolved $CO_2$ in aqueous solution with high sensitivity.

  • PDF

Effect of alumina coating on the Pull-in Voltage in Electrostatically actuated micro device (알루미나 코팅이 정전기적 구동의 마이크로 소자의 풀 인 전압에 미치는 영향)

  • Park, Hyun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5758-5762
    • /
    • 2014
  • Electrostatically-actuated Micro device have been used widely in a variety of integrated sensors and actuators. Electrostatically-actuated micro devices with a gap of several micrometers or less between the electrodes have shown failure problems by electrostatic adhesion. To improve this adhesion phenomenon, micro devices of varying lengths and widths in electrodes were fabricated, and an alumina coating was then deposited using atomic layer deposition technology. The effects of improving adhesion phenomenon were compared by measuring the pull-in voltage before and after the coating process. The pull-in voltage increased with increasing length of the upper electrode after the coating. An increase in the electrode area results in an increase in the pull-in voltage after coating. The alumina coating method applied to improve the adhesion on an electrostatically-actuated micro device was observed as an effective method.

Fluoride Intake by the Duplicate-Diet Technique and Urinary Excretion in Korean Children Aged 3-6 Years

  • Jung, Se-Hwan;Ma, Deuk-Sang;Ryu, Jae-In;Hwang, Jung-Hee;Kho, Young-Lim
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.6
    • /
    • pp.475-482
    • /
    • 2005
  • This study aimed to determine the fluoride intakes in 120 preschool children aged 3 to 6 residing in Jumunjin (community water fluoridation area) and Gangneung (non-fluoridation area). The parents were asked to collect 24-hour urine samples and to duplicate the samples of all the diets that their children ingested in the day of urine collection. The acid-diffusible fluoride in the food and non-carbonate beverages were isolated by the acid-diffusion technique and then measured with a fluoride electrode. The fluoride in carbonate beverages, drinking waters and urine samples were measured directly with a fluoride electrode. The geometric mean (geometric standard deviation) of daily fluoride intakes from all kinds of diet was 5.99 (2.27) $\mu$g/kg/day in the children in Gangneung and that of the children in Jumunjin was 18.36 (2.69). The amount of fluoride intake by food and drinking water in fluoridation area were significantly larger than that in non-fluoridation area but the statistical difference of fluoride intake by beverages between two areas was not observed. The GMs (GSDs) of daily fluoride excretion by urine of children in non-fluoridation area and in fluoridation area were 8.39 (1.73) and 18.62 (1.77) $\mu$g/kg/day, respectively. The correlation between fluoride intake from diet excluding beverage and urinary excretion was statistically significant. It is concluded that the amount of fluoride intake of children living in fluoridation area did not exceed the upper intake level to avoid the risk of dental fluorosis (2.2 mg/day in 4- to 8-year-olds) and urinary excretion of fluoride was good indicator of fluoride intake from diets.

Detection of 10-GHz Optical Single-/Double-Sideband Labels Using Fiber-Optic Interleavers (광섬유 인터리버를 이용한 10-GHz 광 단측파대/양측파대 레이블 검출)

  • Park, Kyoung-Deuk;Shin, Jong-Dug;Kim, Boo-Gyoun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.7C
    • /
    • pp.652-657
    • /
    • 2007
  • Optical subcarrier-multiplexed (OSCM) labels in optical label switching networks have been detected using interleavers composed of fiber-optic Mach-Zehnder interferometer. 10-GHz optical single-/double-sideband signals generated from dual-electrode Mach-Zehnder intensity modulator have been used as the OSCM labels. In the case of single-sideband signals, the upper-sideband was observed to be suppressed about 16.8 dB compared with the lower-sideband from the optical spectrum measured at the label extraction output. For the case of double-sideband signals, both sidebands appeared with small insertion loss at the interleaver output. Since we used the phase-shift method to generate single-sideband signals, the power level of the single-sideband was higher by 3 dB than that of the double-sidebands.

Resonant Mode Analysis of Microwave Film Bulk Acoustic Wave Resonator using 3D Finite Element Method (3차원 유한 요소법을 이용한 초고주파 압전 박막 공진기의 공진 모드해석)

  • 정재호;송영민;이용현;이정희;고광식;최현철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.18-26
    • /
    • 2001
  • In this paper, the resonant characteristics and modes of the film bulk acoustic wave resonator (FBAR) used in 1~2 GHz frequency region are analyzed by it's input impedance which was calculated by three dimensional finite element method formulated as eigenvalue problem using electro-mechanical wave equation and boundary condition. It was extracted that the resonant and the spurious characteristics considering the effects of electrode area and shape variation and unsymmetry of upper and lower electrode. Those effects couldn't be analyzed by on dimensional analysis, e.g. Mason equivalent model. The simulation result was confirmed by comparing with the simulation data from Mason model analysis and the measured data of the ZnO FBAR fabricated using micro-machining technique. Also, through the simulation of the area variations of FBAR, it was obtained that the optimum ratio of length and thickness is 20:1 and the minimum ratio is 5:1 to operate thickness vibration mode.

  • PDF

The Characteristics of Decomposition of NOx by Superposing Discharge Plasma Reactor (중첩 방전 반응기에 의한 NOx의 분해 특성)

  • ;;;;;山常 端樹
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.32-37
    • /
    • 1999
  • The superposing effect of SPCP(Surfoce Induced Plasma Chemical Process) and corona discharge has been studied for rerroval of NOx from industrial flue gases. NOx rermval rates by SPCP, corona discharge and superposing discharge were monitored and compared. Parameters were the concentration and the flow rate of gas, frequency and the type of discharge. Experirrental results showed that NOx removal rate by sUIffPOSing discharge was 10-15[%] higher than that by the other two modes. The higher NOx. rermval rate was observed with the lower frequency of upper electrode in the combined reactor and with the higher frequency of lower electrode. 'The maximum obtainable NOx. rerroval rate by SPCP (18 [W]) and corona discharge (8.5 [W]) was 80[%] and 10[%], respectively. With the combination of the two modes, however, 90[%] of NOx removal rate was observed with the discharge power of 14 [W].14 [W].

  • PDF

Microstructure properties with variation of doped amount $Pr_{2}O_{3}$ of BSCT ceramics ($Pr_{2}O_{3}$ 첨가량에 따른 BSCT 세라믹의 미세구조 특성)

  • Noh, Hyun-Ji;Lee, Sung-Gap;Park, Sang-Man;Yun, Sang-Eun;Kim, Ji-Eun;Lee, Young-Hie
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1283-1284
    • /
    • 2007
  • The barium strontium calcium titanate((Ba,Sr,Ca)$TiO_3$) powders prepared by the sol-gel method and $MnCO_3$ as acceptor were mixed oxide method. The microstructure was investigated with variation of $Pr_{2}O_{3}$ amount. The BSCT powder and $Pr_{2}O_{3}$ were mixed with organic vehicle(Ferro. B75001). BSCT thick films were fabricated by the screen-printing method on alumina substrates. The bottom electrode was Pt and upper electrode was Ag, respectively. All BSCT thick films were sintered at $1420^{\circ}C$, for 2h. The result of the differential thermal analysis(DTA), exothermic peak at around $654^{\circ}C$ due to the formation of the polycrystalline perovskite phase. In the X-ray diffraction(XRD) patterns, all BSCT thick films showed the typical perovskite polycrystalline structure and no pyrochlore phase was dbserved. The microstructure investigated by scanning electron microscope(SEM). Pore and grain size of BSCT thick films were decreased with increasing amount of $Pr_{2}O_{3}$ dopant. And the average grain size and thickness of BSCT thick films doped with 0.1 mol% $Pr_{2}O_{3}$ was $3.09{\mu}m$, $60{\mu}m$, respectively. The relative dielectric constant decreased and dielectric loss decreased with increasing amount of $Pr_{2}O_{3}$ dopant, the values of the BSCT thick films no doped with $Pr_{2}O_{3}$ were 7443 and 4 % at 1 kHz, respectively.

  • PDF

A Study of Surface Electromyography Measurement of Orbicularis oris motion in Healthy People (정상인의 구륜근 운동 시 표면근전도(SEMG) 측정연구)

  • Kim, Ju Yong;Kim, Bo Hyun;Kim, Hye Bin;Yook, Tae Han;Kim, Jong Uk
    • Journal of Acupuncture Research
    • /
    • v.33 no.4
    • /
    • pp.93-100
    • /
    • 2016
  • Objectives : To find an acupuncture point where more exact Surface Electromyography(SEMG) measurement can be drown, through the study of measurement of orbicularis oris. Methods : Of healthy people from 19 to 40 years of age, who did not fall under exclusion criteria (22 males and 22 females), were selected as subjects, after relaxation for 10 minutes, and they were told how to pronounce 'O' and 'U' with their lips puckered. The SEMG figures were measured with attaching disposable electrode on acupuncture point of right-and-left Hwaryo(LI19) and 1 cun away from Seungjang(CV24) on both sides when the subjects pronounced 'O' and 'U'. Results : The average value was highest on left 1 cun away from Seungjang(CV24) in pronouncing 'O' and 'U', and the average SEMG value was higher in the order of right 1 cun away from Seungjang(CV24), right Hwaryo(LI19), left Hwaryo(LI19). Average of the lower orbicularis oris is statistically higher than that of the upper orbicularis oris, which has significant meaning. However, there was no significant difference when compared by pronunciation. Average of percentage mark of differences of right-and-left measured value of each pronunciation and each acupuncture point : Pronounced 'O' and the upper part of orbicularis oris: $16.76{\pm}11.29%$, pronounced 'O' and the lower part of orbicularis oris: $22.41{\pm}12.92%$, pronounced 'U' and the upper part of orbicularis oris: $17.10{\pm}9.89%$, pronounced 'U' and the lower part of orbicularis oris : $19.20{\pm}10.82%$. Conclusion : The difference of pronunciation will not affect the results in SEMG measurement. In addition, the average of the lower orbicularis oris is statistically and significantly higher than that of the upper orbicularis oris.