• Title/Summary/Keyword: Upper abdomen

Search Result 268, Processing Time 0.025 seconds

The Retrospective Comparative Study of General Acupuncture Therapy and Hominis placenta Pharmacopuncture Therapy on Severe Dyspepsia (중증 소화불량증 환자에 대해 체침요법과 자하거 약침요법의 치료 효과에 대한 후향적 비교 연구)

  • Lee, Ah-Ram;Kim, Won-Il
    • Korean Journal of Acupuncture
    • /
    • v.30 no.4
    • /
    • pp.319-328
    • /
    • 2013
  • Objectives : The purpose of this research was to compare the effect of general acupuncture therapy to Hominis placenta Pharmacopuncture therapy on pain and discomfort of severe dyspepsia in upper abdomen. Methods : We investigated 60 cases of patients with severe dyspepsia, who had been treated at Dept. of Internal Medicine, College of Oriental Medicine Dongeui University from May 2011 to September 2012. We divided patients into two groups : Group I was treated by general acupuncture(ACU, n=30) and Group II was treated by Hominis placenta Pharmacopuncture therapy(PHA, n=30). The symptoms and quality of life were measured with the Nepean dyspepsia index-Korean version(NDI-K) at baseline and 2 weeks. The responsiveness of the NDI-K was evaluated by correlation with symptom scores. Results : In ACU group, the 13 symptom scores were significantly decreased after treatment(p<0.05). In PHA group, the 9 symptom scores were significantly decreased after treatment(p<0.05). In ACU group, the 3 Quality of life(QOL) scores were significantly increased after treatment(p<0.01). In PHA group, the 3 QOL scores were significantly increased after treatment(p<0.05). Conclusions : General acupuncture therapy and Hominis placenta Pharmacopuncture therapy improves the symptoms and the quality of life in patients with severe dyspepsia. But there were no significant differences statistically between the two groups.

Building up the foundation for the elderly apparel industry through the study on the body shapes of elderly obese males (노년 비만남성의 체형연구를 통한 실버 의류산업 활성화 기반 구축)

  • Seong, Ok jin;Kim, Sook jin
    • The Research Journal of the Costume Culture
    • /
    • v.26 no.5
    • /
    • pp.665-678
    • /
    • 2018
  • The purpose of this study is to promote the elderly apparel industry for the increasing numbers of elderly obese male population. In the study, a total number of 249 males between the ages of 60 to 85 were studied to analyze their body types and differences. The group had a Rohrer Index of 1.6 or higher and BMI of 25 or higher. The noticeable physical differences in the group were shorter waist front length, bigger waist and hip circumferences with increasing age and slimmer limbs that are associated with the natural aging process with or without obesity. The obese body types have been classified in the following 3 different categories. Type 1 is the group that has lower body obesity with broad shoulders and relatively slimmer abdomen than a heavy bottom. A total number of 84 people belonged to the type 1 obesity category which makes up 33.8% of the total. Type 2 is the group that has upper body obesity with especially large abdominal obesity. A total number of 76 people, 30.5% of the total, were classified as type 2. Type 3 is the group that has whole body obesity with balanced obesity in the whole body. A total number of 89 people, 35.7% of the total, made up type 3.

A Study on the Fit Preferences of the Tailored Jacket for Women Using 3D Clothes Modeling System (3차원 의상 모델링 시스템을 이용한 여성용 테일러드 재킷의 맞음새 평가)

  • Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.9
    • /
    • pp.940-951
    • /
    • 2012
  • This study evaluates the fit preference of the tailored jacket according to body types for 20's adult women through a comparison of real and virtual fit. A five point fit evaluation scale utilizing a wearer acceptability scale by Shen and Huck was used to evaluate the degree of the preference of real and virtual fit. This scale contained 23 items in three categories: front fit, back fit, and side fit. For each item, 5 responses from 'too tight' fit (1 point) to 'too loose' fit (5 point) were possible. The middle position for each fit criterion indicated a 'good' fit (3 point). The data were analyzed with a t-test using statistical program SPSS 17.0. According to the results, there were no significant differences ($p{\leq}.05$) between the real and virtual fit preference in total measurement items such as front collar, lapel and roll line, front shoulder slope, front armhole, front waist, abdomen, sideseam, hemline, front silhouette, side shoulder, side armhole, side sleeve width, side hip, side silhouette, back collar stand, upper back, back armhole, back waist, back hip, back silhouette except front bust, side waist, and back center back. The factor that caused a difference in the fit preference between the real and virtual fit evaluation was a specific body type such as Body Type A that indicated a small bust circumference and a big hip circumference.

Clinical Evaluation and The Diagnositic Significances of Disital Infrared Thermal Image(D.I.T.I.) on the Patients of Dam Hun(痰暈) (담훈(痰暈)환자의 임상적 고찰과 복부 적외선 체열촬영의 의의)

  • Park, Mee-Yeon;Choi, Hae-Yun;Kim, Jong-Dae;Song, Kwang-Kyu
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.2
    • /
    • pp.488-493
    • /
    • 2006
  • To make a objective diagnosis of Dam Hun(痰暈), we investigated the 63 patients with Dam Hun(痰暈) and 34 normal people as control group. we compared the thermal difference between Chon-jung(CV17 ) and Chung-wan(CV12 中脘), Chon-jung(CV17 ) and Gwan-won(CV4 關元) and we compared the thermal difference of Yang-mun(ST21 梁門), Chun_chu(ST25 天樞), Su-do(ST28 水道), too. All 63 patients had dizziness and GI trouble. They had the symptom - fatigue, nausea vomitting, head heaviness, indigestion, cold limbs, headache, heart burn, constipation, diarrhea, anorexia. And some had edema, numbness, insomnia, palpitation, facial flushing, dysuria, ringing. Considering the average temparature of Chon-jung(CV17 ), Chung-wan(CV12 中脘), Gwan-won(CV4 關元), Yang-mun(ST21 梁門), Chun-chu(ST25 天樞), Su-do(ST28 水道) between the patients group and the control group, the patients group were lower than the control group except for Chon-jung(CV17 ), Gwan-won(CV4 關元), but the statistical significance was not. Considering the thermal difference of Chon-jung(CV17 ) and Chung-wan(CV12 中脘), Gwan-won(CV4 關元), Yang-mun(ST21 梁門), Chun-chu(ST25 天樞), Su-do(ST28 氷道) between the patients group and the control group, the temparature deviation of Chon-jung(CV17 ) and Chung-wan(CV12 中脘), Chon-jung(CV17 ) and Yang-mun(ST21 梁門) was significant. We suggest that coldness of upper abdomen is significant in diagnosis of Dam Hun(痰暈).

Ectopic Human Fasciola hepatica Infection by an Adult Worm in the Mesocolon

  • Kim, Ah Jin;Choi, Chang Hwan;Choi, Sun Keun;Shin, Yong Woon;Park, Yun-Kyu;Kim, Lucia;Choi, Suk Jin;Han, Jee Young;Kim, Joon Mee;Chu, Young Chae;Park, In Suh
    • Parasites, Hosts and Diseases
    • /
    • v.53 no.6
    • /
    • pp.725-730
    • /
    • 2015
  • We report here an ectopic case of Fasciola hepatica infection confirmed by recovery of an adult worm in the mesocolon. A 56-year-old female was admitted to our hospital with discomfort and pain in the left lower quadrant of the abdomen. Abdominal CT showed 3 abscesses in the left upper quadrant, mesentery, and pelvic cavity. On surgical exploration, abscess pockets were found in the mesocolon of the sigmoid colon and transverse colon. A leaf-like worm found in the abscess pocket of the mesocolon of the left colon was diagnosed as an adult fluke of F. hepatica. Histologically, numerous eggs of F. hepatica were noted with acute and chronic granulomatous inflammations in the subserosa and pericolic adipose tissues. Conclusively, a rare case of ectopic fascioliasis has been confirmed in this study by the adult worm recovery of F. hepatica in the mesocolon.

Structure and Histochemistry of the Skin of a Flat-headed Goby, Luciogobius guttatus (Gobiidae, Pisces) from Korea (한국산 미끈망둑 Luciogobius guttatus (망둑어과) 피부의 구조 및 조직화학적 특성)

  • Park, Jong-Young;Lee, Yong-Joo;Kim, Ik-Soo
    • Korean Journal of Ichthyology
    • /
    • v.19 no.2
    • /
    • pp.120-127
    • /
    • 2007
  • To investigate the skin of the flat-headed goby, Luciogobius guttatus, it was used 8 body regions such as the head, the upper and lower jaw, the chin, the back, lateral region, abdomen, and the operculum. The epidermis consisted of three layers: the outermost layer, middle layer and stratum germinativum (basal layer). The outermost layer consisted of rather flattened cells arranged in 1 to 4 layers and mucous cells. The middle layer consisted of large epidermal cells occupying the height of the epidermis with 1 to 10 layers, causing a web-shaped structure. Due to the large epidermal cells of the middle layer, L. guttaus had a thick epidermis. The large epidermal cell contains tonofilaments, lucent contents, and desmosome. The basal layer was comprised of a single layer having cuboidal cells. A large number of fine blood capillaries were found just under the basal layer. The dermis consisted mostly of stratum compactum with numerous blood capillaries but had no scale.

The Effect of Electrical Stimulation of Body Composition in Obese Person (전기자극이 체성분에 미치는 효과)

  • Kim, Yong-Seong;Bang, Sang-Bun
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.3
    • /
    • pp.13-24
    • /
    • 2004
  • The purpose of this study is to reveal the effect of electrical stimulation of body composition in obese person. Subjects were 30s to 40s aged healthy workers(2004. 3. 8~4. 17) in the S general Hospital in Suwon and they were brought to manage obesity. Subjects were divided into control group(Female<0.85, Male<0.90) and study group(Female>0.85, Male>0.90) by WHR(waist-hip ratio) that is measured by Automatic body composition analyzer(InBody 3.0). And we divided the study group with randomized methods into group A(n=8) and group B(n=8). Then we compared and analyzed the change of muscle mass, body fat, abdominal girth, WHR, BMI(body mass index) after application of electrical stimulation, three times a week, for 30 minutes in each session with 50 Hz of pulse frequency, $20\;{\mu}s$ or $250\;{\mu}s$ of pulse duration. There was statistically meaningful decrement of body fat(p<0.05) and abdominal girth(p<0.05) but not of body weight, muscle mass, WHR and BMI in the control group after application of electrical stimulation with 50 Hz, $20\;{\mu}s$. There were meaningful change of abdominal girth(p<0.05), WHR(p<0.05) and BMI(p<0.05), but not of body weight, muscle mass and body fat after application of electrical stimulation with 50 Hz, $20\;{\mu}s$ in group A. We applied electrical stimulation with 50 Hz, $250\;{\mu}s$ in group B, then there were meaningful change of body weight(p<0.05), body fat(p<0.01), abdominal girth(p<0.01), WHR(p<0.05) and BMI(p<0.01) but not of muscle mass only. Consequently, the pulse duration is the main parameter of electrical stimulation that affect the body composition of obese person in this study and if we combined the diet control to reduce blood components we could have better result. So it would be more effective to manage localized obesity(in abdomen, thigh, upper arm, etc.) if you apply electrical stimulation considering the pulse duration.

  • PDF

The Effects of Uncooked Grains and Vegetables with Mainly Brown Rice on Weight Control and Serum Components in Korean Overweight/obese Female (현미로 주원료로 한 생식이 과체중/비만 여성의 비만도와 혈액 성분에 미치는 영향)

  • 하태열;김나영
    • Journal of Nutrition and Health
    • /
    • v.36 no.2
    • /
    • pp.183-190
    • /
    • 2003
  • This study was designed to investigate the effects of weight control and changes in serum components using a commercial uncooked food diet on 36 obese women over a period of 8 weeks. The subjects had uncooked food (40 g) with milk or soymilk twice a day instead of meals. The mean body weight and height measurements of the subjects at the outset were 69.1 $\pm$ 9.3 kg and 159.5 $\pm$ 4.4 cm, respectively. Initial daily calorie intake was 103.6 % of RDA, but was significantly lower at 4 and 8 weeks. The subjects showed a significant reduction in weight, body fat mass (p<0.05), anthropo-metric value and skinfold thickness during the experimental period. Hip and upper thigh girth were 102.7 $\pm$ 6.4 cm and 61.7 $\pm$ 4.3 cm at the outset, and fell to 99.3 $\pm$ 5.0 cm and 58.8 $\pm$ 4.1 cm after 8 weeks. The most significant reduction was in abdomen skinfold thickness (p < 0.05) , which went from 32.4 $\pm$ 8.7 mm at first to 24.2 $\pm$ 8.3 mm in after 8 weeks. Serum albumin levels were higher at 4 and 8 weeks than initially but the figures for all of the subjects were within the normal range. Hemoglobin and blood glucose levels were also within the normal range during the experimental period. Initial serum triglyceride level was 110.5 $\pm$ 49.5 mg/dl but fell to 93.2 $\pm$ 48.5 mg/dl after 8 weeks. Our results show that uncooked foods are effective in the diet therapy of obese women.

Alteration in Infrared Thermal Imaging by Use of Acupuncture-like Electric Stimulation on Finger Control Gate (체열촬영으로 관찰한 전기수지자극의 효과)

  • Lee, Sang-Hun;Lee, Kyu-Chang;Woo, Nam-Sik;Lee, Ye-Chul;Kim, Sun-Bok;Lee, Hyung-Hoan
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.222-230
    • /
    • 1994
  • Acupuncture-like transcutaneous electrical nerve stimulation(ALTENS) on acupuncture site(dorsal and ventral side of finger) were compared with a placebo site(forearm) by infrared thermal imaging. Six disease-free volunteers underwent, on different days, an ALTENS treatment and a placebo treatment in a cross-over sequences of stimulation control and inhibition control in excess of 50 treatments. ALTENS treatments were given at 30Hz at an intensity just below pain threshold delivered to acupuncture points on fingers. Placebo stimulations were administered in similar manner. After every thirty minutes of ALTENS and placebo treatment with stimulation, inhibition control sequence and vice versa, we examined whole body infrared thermal imaging and checked changed skin temperature on frontal, anterior chest, upper and lower abdomen, dorsal and ventral aspect of hand, thoracic and lumbar area, anterior and posterior aspect of lower leg. There were significant skin temperature elevations with ALTENS treatment, especially finger control gate corresponding organ area. Placebo treatment revealed no skin temperature change. We concluded that ALTENS on finger control gate influence physiologic state as opposed to conventional electric stimulation.

  • PDF

Characteristics of Acupuncture at LU10 on Abdominal Thermography of Health Subject (어제(魚際)(LU10) 자침(刺鍼)이 복부(腹部) 한열변화(寒熱變化)에 미치는 영향(影響))

  • Jeon Moon-Kee;Kim Jae-Hyo;Byun Kee-Won;Do Jin-Woo;Kim Kyung-Sik;Sohn In-Cheul
    • Korean Journal of Acupuncture
    • /
    • v.20 no.2
    • /
    • pp.1-20
    • /
    • 2003
  • This study was examined for characteristics of acupuncture of LU10 on the abdominal thermography of health subject. The volunteers who participating in this study had taken rest for 20 - 30 mins in room temperature $(23-25^{\circ}C)$ before the examination and informed them what to prohibit smoking, drinking and administration of drug for the previous day. The thermography of abdomen including a below part of the chest was taken using Infra-Red Imaging System (IR 2000, MEDI-CORE Co., Korea) by time interval of 15 minutes at 15 min before, just before and 15 min after, 30 min after and 45 min after acupuncture stimulation. Acupuncture was applied to both LU10 for 30 mins. The results showed that acupuncture of LU10 for 30 mins had more potencies of changes on all the ROIs of abdominal thermography than those of control group. Also, those responses were significantly clear at the A1, A3, A6, A7 and A9 areas. It was observed that the quantities of thermal changes following acupuncture of LU10 been increased significantly comparing that of control group at the all ROIs (region of interest). These effects have more potencies at the upper (A1 and A2) and below (A7, A8, A9) abdominal areas than midline ones (A4, A5, and A6). These results suggest that acupuncture of LU10 having the characteristics of controls of chill and fever (寒熱) may modulate thermal distributions and changes of abdominal areas including the below of chest.

  • PDF