A STUDY ON MEASUREMENT OF MINIMAL DISTANCE BETWEEN PULP CHAMBER AND CORONAL SURFACE (치수강(齒髓腔)과 치관외면(齒冠外面)과의 최단거리(最短距離)에 관(關)한 실측연구(實測硏究))

  • Kim, Yung-Hai
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.2
    • /
    • pp.1-4
    • /
    • 1989
  • To determine the thickness of coronal hard structure the minimal distance between pupal surface and outer surface of crown was measured by means of Bowley gauge on extracted first molars. Upper(28 teeth) and lower(24 teeth) were carefully collected from 30-39 years of age and male. The teeth were split mesio-distally through central pit. On the split surface various part which are deeply related in cavity preparation were measured (schematic drawing). The results were as follows: A : Distance from mesio-cervical enamel to pulp chamber surface. upper $2.63{\pm}0.19$(mm) Lower $2.18{\pm}0.27$(um) B : Distance from mesial chamber ceiling to mesial surface upper $2.75{\pm}0.34$ Lower $2.62{\pm}0.31$ C : Distance from mesial chamber ceiling to occlusal surface upper $3.82{\pm}0.51$ Lower $3.49{\pm}0.50$ D : Distance from distal chamber ceiling to occlusal surface upper $4.28{\pm}0.69$ Lower $3.90{\pm}0.52$ E : Distance from distal chamber ceiling to distal surface upper $2.79{\pm}0.45$ Lower $2.41{\pm}0.40$ F : Distance from disto cervical enamel to pulp chamber surface upper $2.49{\pm}0.24$ Lower $2.39{\pm}0.25$.

  • PDF

Cor triatriatum associated with partial anomalous pulmonary venous drainage: one case report (폐정맥 환류이상을 동반한 삼중방심 치험 1)

  • Kim, Yeong-Ho;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.381-388
    • /
    • 1984
  • Cor triatriatum is rare congenital cardiac anomaly first described by Church in 1868. The anomaly consists of an abnormal partitioning of the left atrium by a fibromuscular membrane that divides the atrium into an upper chamber, which receives the pulmonary veins, and a lower chamber, which contains the atrial appendage and the mitral valve. The upper and lower chambers communicate through a stenotic fenestration in the membrane, which has the hemodynamic consequence of pulmonary venous obstruction. Recently we experienced cot triatriatum associated with partial anomalous pulmonary drainage to right atrium. The upper chamber was connected to right atrium through a sinus venous type of ASD and received left superior and both inferior pulmonary vein, whereas the lower chamber so called true left atrium communicated with right atrium through foramen ovale type of ASD, left atrial appendage and mitral orifice. And the anomalous membrane has no fenestrations which permit blood flow. The operation was made right atrial approach under the CPB. We excised completely the anomalous septum and reconstructed atrial septal defect with pericardial patch to drain the right upper pulmonary vein to the left atrium. The postoperative course has been good during follow up.

  • PDF

Cor triatriatum(A case report) (삼중방심 치험 1예)

  • 정경영
    • Journal of Chest Surgery
    • /
    • v.16 no.3
    • /
    • pp.331-336
    • /
    • 1983
  • Cor triatriatum is a rare congenital malformation of the heart, in which a septum stretches in a transverse or oblique plane through the left atrium, thus separating it into two compartments. The upper one connects with the pulmonary veins, and the lower one connects with the left ventricle. Due to the rarity of, and great difficulty in-diagnosing, cor trlatrlatum, data On the surgery of this disease are of necessity very limited and so accurate pre-operative diagnosis was very difficult to make. `We experienced a case of the cyanotic congenital heart disease which was diagnosed as a large atrlal septal defect with streaming venous blood from inferior vena cava to left atrium through atrial septal defect in August, 1982. We found that there were transverse septum in the left atrium through atrlal septal defect, the pulmonary venous drainage were located in the upper chamber of the left atrium, and the lower chamber was connected with the left atrial appendage, mitral valve and `left ventricle. But our case had not any opening in this transverse septum and the right atrium was connected with the upper chamber of the left atrium through the upper part of the atrlal septal defect, and was communicated with the lower chamber of the left atrium through the lower part of the atrlal septal defect. We excised the transverse septum and repair this atrial septal defect with Woven Dacron patch accompanying with the drainage of coronary sinus to right atrium. The post-operative course was not eventful and he was discharged with good result on the post-operative 8th day, and has been in good .condition up to now for longer than 10 months.

  • PDF

STUDY ON THE THERMAL-FLUID ANALYSIS OF CRYOGENIC CHAMBER FOR COLD CLIMATE TEST OF LARGE WIND TURBINE PARTS (대형 풍력발전기 부품의 극한 환경 시험을 위한 극저온 챔버의 열유동 해석에 대한 연구)

  • Kim, M.K.;Kang, Y.H.;Park, W.G.
    • Journal of computational fluids engineering
    • /
    • v.20 no.3
    • /
    • pp.8-14
    • /
    • 2015
  • More and more, spaces are decreasing which satisfy multiple requirements for wind power plants. However, areas which have excellent wind resources and are free to civil complaints occupy a large space, although they are exposed to the cryogenic environment. This study conducted a thermal-fluid analysis of a cryogenic chamber for testing large wind turbine parts exposed to the cryogenic environment. The position of supply air is placed to the upper area to compare each cooling performance for each location of various outlets in mixing ventilated conditions. The study carried out CFD analysis for the chamber both with and without a test object. For the cases without the test object, the air temperature of the upper supply and down extract type chamber was cooled faster by 5-100% than the others. However, for the cases with the test object, the object temperature of upper supply and center extract on the opposite side type chamber was cooled faster by 33-132% than the others. The cooling performance by the air inside the chamber and the test object did not show the same pattern, which implicates the need to consider the cooling performance by not only the air but also the test object in the large cryogenic chamber design for testing large parts.

Development of having double-chamber in micro-bubble pump (두 개의 챔버를 갖는 마이크로 버블펌프의 개발)

  • 최종필;박대섭;반준호;김병희;장인배;김헌영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1186-1190
    • /
    • 2003
  • In this paper, a valveless bubble-actuated fluid micropump was has been developed and its performance was tested. The valveless micropump consists of the lower plate, the middle plate, the upper plate and a resistive heater. The lower plate includes the nozzle-diffuser elements and the double-chamber. Nozzle-diffuser elements and a double-chamber are fabricated on the silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The lower plate also has inlet/outlet channels for fluid flow. The middle plate is made of glass and plays the role of the diaphragm. The chamber in the upper plate is filled with deionized water, and which contacts with the resistive heater. The resistive heater is patterned on a silicon substrate by Ti/Pt sputtering. Three plates and the resister heater are laminated by the aligner and bonded in the anodic bonder. Since the bubble is evaporated and condensed periodically in the chamber, the fluid flows from inlet to outlet with respect to the diffusion effect. In order to avoid backflow, the double chamber system is introduced. Analytical and experimental results show the validity of the developed double-chamber micropump.

  • PDF

A Study on the CFD Analysis and Estimation of the Energy Efficiency of Cryogenic Chamber for Extreme Climate Test (극한 환경 시험을 위한 극저온 챔버의 CFD 해석 및 에너지 효율 평가에 관한 연구)

  • Kang, Yul-Ho;Kim, Min-Kyu;Park, Warn-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.2
    • /
    • pp.81-88
    • /
    • 2016
  • There are many types of national and international standards for low temperature tests depending on the products. This study conducted CFD analysis and estimation of the energy efficiency of the chamber both with and without a test object by considering variations of COP and specific volume according to temperature. The supply air was located in the upper area to compare the cooling performance for each location using various outlets in mixed ventilated conditions. For cases without the test object, the air temperature of the upper supply and center extract on the opposite side type chamber cooled faster than other areas by 4.3~29.8%. However, for cases with the test object, the object temperature of the upper supply and lower extract type chamber cooled faster than the other areas by 7.2~31.5%. The cooling efficiency of the air inside the chamber and the test object did not show the same pattern, which indicates the need to consider the cooling performance by not only the air but also the test object in the cryogenic chamber design for testing.

Combustion Stability Characteristics of the Model Chamber with Various Configurations of Triplet Impinging-Jet Injectors

  • Sohn Chae-Hoon;Seol Woo-Seok;Shibanov Alexander A.
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.874-881
    • /
    • 2006
  • Combustion stability characteristics in actual full-scale combustion chamber of a rocket engine are investigated by experimental tests with the model (sub-scale) chamber. The present hot-fire tests adopt the combustion chamber with three configurations of triplet impinging-jet injectors such as F-O-O-F, F-O-F, and O-F-O configurations. Combustion stability bound-aries are obtained and presented by the parameters of combustion-chamber pressure and mixture (oxidizer/fuel) ratio. From the experimental tests, two instability regions are observed and the pressure oscillations have the similar patterns irrespective of injector configuration. But, the O-F-O injector configuration shows broader upper-instability region than the other configurations. To verify the instability mechanism for the lower and upper instability regions, air-purge acoustic test is conducted and the photograph or the flames is taken. As a result, it is found that the pressure oscillations in the two regions can be characterized by the first impinging point of hydraulic jets and pre-blowout combustion, respectively.

The Flow Analysis and Evaluation of the Peristaltic Micropump (마이크로 정량펌프의 유동해석과 작동성능 평가)

  • 박대섭;최종필;김병희;장인배;김헌영
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.195-202
    • /
    • 2004
  • This paper presents the fabrication and evaluation of mechanical behavior for a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of the lower plate, the middle plate, the upper plate and the tube that connects inlet and outlet of the pump. The lower plate includes the channel and the chamber, and the plain middle plate are made of glass and actuated by the piezoelectric translator. Channels and a chamber on the lower plate are fabricated on high processability silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The upper plate does the roll of a pump cover and has inlet/outlet/electric holes. Three plates are laminated by the aligner and bonded by the anodic bonding process. Flow simulation is performed using error-reduced finite volume method (FVM). As results of the flow simulation and experiments, the single chamber pump has severe flow problems, such as a backflow and large fluctuation of a flow rate. It is proved that the double-chamber micropump proposed in this paper can reduce the drawback of the single-chamber one.

Development of a Garlic Peeling System Using High-Pressure Water Jets (II) - Garlic peeling by cylindrical chamber with drilled nozzles - (습식 마늘박피 시스템 개발 (II) - 다수의 노즐이 배열된 원통형 챔버를 이용한 박피 실험)

  • 양규원;배영환;백성기
    • Journal of Biosystems Engineering
    • /
    • v.29 no.3
    • /
    • pp.225-232
    • /
    • 2004
  • A new type of garlic peeling chamber has been developed which separates and peels garlic cloves using high-Pressure water Jets. The cylindrically-shaped chamber was fabricated with stainless steel plate and has a number of drilled holes, which function as solid-stream spray nozzles, on its interior wall. The chamber was divided into upper and lower section so that water can be applied at different pressures from each section. Three chambers of similar design were tested to evaluate their performances according to various pressure levels. The strongest correlation was observed between the pressure difference(lower-upper) and the proportion of unseparated and completely-peeled garlic cloves. Hanji-type garlic required higher or pressure difference to separate cloves from garlic bulbs than nanji-type garlic. On the other hand, protective leaves(skin) from the cloves were peeled more easily in case of hanji-type garlic. As a result of three consecutive peeling operations, the proportion of completely-peeled garlic cloves changed in the order of 80.1, 82.6, 84.1% in case of hanji-type, and 19.6, 29.1, 40.2% in case of nanji-type garlic.

Hot- Fire Injector Test for Determination of Combustion Stability Boundaries Using Model Chamber

  • Sohn Chae Hoon;Seol Woo-Seok;Shibanov Alexander A.;Pikalov Valery P.
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.9
    • /
    • pp.1821-1832
    • /
    • 2005
  • This study realizes the conceptual method to predict combustion instability in actual full-scale combustion chamber of rocket engines by experimental tests with model (sub-scale) chamber. The model chamber was designed based on the methodologies proposed in the previous work regarding geometrical dimensions and operating conditions, and hot-fire test procedures were followed to obtain stability boundaries. From the experimental tests, two instability regions are presented by the parameters of combustion-chamber pressure and mixture (oxidizer/fuel) ratio, which are customary for combustor designers. It is found that instability characteristics in the chamber with the adopted jet injectors can be explained by the correlation between the characteristic burning or mixing time and the characteristic acoustic time: In each instability region, dynamic behaviors of flames are investigated to verify the hydrodynamically-derived characteristic lengths of the jet injectors. Large-amplitude pressure oscillation observed in upper instability region is found to be generated by lifted-off flames.