• 제목/요약/키워드: Upper/Lower Limit

검색결과 357건 처리시간 0.028초

운고계 후방산란 강도와 기상변수 자료를 이용한 지표면 PM2.5 농도 계산 (Calculations of Surface PM2.5 Concentrations Using Data from Ceilometer Backscatters and Meteorological Variables)

  • 정희정;엄준식
    • 한국환경과학회지
    • /
    • 제31권1호
    • /
    • pp.61-76
    • /
    • 2022
  • In this study, surface particulate matter (PM2.5) concentrations were calculated based on empirical equations using measurements of ceilometer backscatter intensities and meteorological variables taken over 19 months. To quantify the importance of meteorological conditions on the calculations of surface PM2.5 concentrations, eight different meteorological conditions were considered. For each meteorological condition, the optimal upper limit height for an integration of ceilometer backscatter intensity and coefficients for the empirical equations were determined using cross-validation processes with and without considering meteorological variables. The results showed that the optimal upper limit heights and coefficients depended heavily on the meteorological conditions, which, in turn, exhibited extensive impacts on the estimated surface PM2.5 concentrations. A comparison with the measurements of surface PM2.5 concentrations showed that the calculated surface PM2.5 concentrations exhibited better results (i.e., higher correlation coefficient and lower root mean square error) when considering meteorological variables for all eight meteorological conditions. Furthermore, applying optimal upper limit heights for different weather conditions revealed better results compared with a constant upper limit height (e.g., 150 m) that was used in previous studies. The impacts of vertical distributions of ceilometer backscatter intensities on the calculations of surface PM2.5 concentrations were also examined.

DEA with Interval Efficiency Values

  • MAEDA, Yutaka;ENTANI, Tomoe;TANAKA, Hideo
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1998년도 The Third Asian Fuzzy Systems Symposium
    • /
    • pp.69-74
    • /
    • 1998
  • In this paper, we formulate the DEA model with interval efficiency, there exist two phases of efficiency evaluation with respect to the upper limit and the lower limit. From these viewpoints, we can define two extreme points of efficiency. As a result, an interval efficiency for each DMU cam be obtained. We also formulate the interval cross-efficiency.

  • PDF

Diagnosis of Thickness Quality Using Multivariate Statistical Analysis in Hot Finishing Mill

  • Kim, Heung-Mook
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.116.3-116
    • /
    • 2001
  • A diagnosis methodology for thickness quality in hot finishing mill is proposed based on multivariate statistical analysis. The thickness of hot strip is a key quality factor that is measured by x-ray thickness gauge. Currently, the thickness quality is guaranteed by upper and lower limit of thickness deviation from target thickness. But if any over-limit is occurred, there is no in-line method to identify the causes. In this paper, many parameters are extracted from the thickness deviation signal such as mean deviation(top, middle, tail), rms deviation(top, middle, tail) and peak deviation(top, middle, tail) as time domain parameters ...

  • PDF

2-Ethylhexanoic Acid의 폭발위험성에 관한 연구 (Explosion Risk of 2-Ethylhexanoic Acid)

  • 김원길;김정훈;최재욱
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.20-25
    • /
    • 2015
  • 2-Ethylhexanoic acid는 플라스틱의 충격보강제를 제조하는 물질로서 공정 중에 폭발위험성을 고찰하기 위하여 산소농도 변화에 따른 폭발범위, 폭발압력, 최대폭발압력상승속도를 실험한 결과 실험온도 $100^{\circ}C$에서, 산소농도 40~70%에서 폭발하한농도 3.2%를 구하였으며, 산소농도 21%에서 폭발하한 농도는 4.0%, 폭발상한 농도는 4.5%를 구하였다. 또한, 2-ethylhexanoic acid의 폭발압력은 산소농도 70%에서 1.4161 MPa의 최대폭발압력을 나타내었으며, 최대폭발압력상승속도를 구한 결과 산소농도 70%에서 62.692MPa/s를 구하였다.

가연성증기의 폭발한계 및 폭발특성에 관한 연구 (A Study on the Explosion Limit and Explosion Characteristics of Flammable Vapor)

  • 김영수;이민세;신창섭
    • 한국안전학회지
    • /
    • 제13권2호
    • /
    • pp.116-121
    • /
    • 1998
  • Various flammable vapors as energy source and raw material have been stored, transported in the industries, and accidental leakage of these vapors occurs occasionally. Without an appropriate protection system, flammable vapors can be ignited and serious damage results from them. To reduce the risk caused by explosion, we should know the explosion limit and explosion characteristics. In this study, the maximum explosion pressure, the maximum explosion pressure rise, the effect of temperature and mixing with other vapor were measured in a cylindrical vessel. Experimental results showed that maximum explosion pressure of flammable vapor was about 3.1~$4.2 kg/cm^2$ and it was reached 3.4 times faster than that at explosion limit. The lower explosion limit was coincided well with Le Chateilier's equation, however, upper explosion limit was not.

  • PDF

임상보고 가능범위의 실증적 연구 (An Empirical Study of the Clinically Reportable Range in Clinical Chemistry)

  • 장상우;이상곤;최호성;송은영;박용원;이인애
    • 대한임상검사과학회지
    • /
    • 제39권1호
    • /
    • pp.31-36
    • /
    • 2007
  • The purpose of the clinically reportable range (CRR) in clinical chemistry is to estimate linearity in working range. The reportable range includes all results that may be reliably reported, and embraces two types of ranges: the analytical measurement range (AMR) is the range of analyte values that a method can directly measure on the specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. CAP and JCAHO require linearity on analyzers every six months. The clinically reportable range is the range of analyte values that a method can measure, allowing for specimen dilution, concentration, or other pretreatment used to extend the direct analytical measurement range. The AMR cannot exceed the manufacturer's limits. Establishing AMR is easily accomplished with Calibration Verification Assessment and experimental Linearity. For example: The manufacturer states that the limits of the AST on their instrument are 0-1100. The lowest level that could be verified is 2. The upper level is 1241. The verified AMR of the instrument is 2-1241. The lower limit of the range is 2, because that is the lowest level that could be verified by the laboratory. The laboratory could not use the manufacturer's lower limit of 2 because they have not proven that the instrument values below 2 are valid. The upper limit of the range is 1241, because although the lab has shown that the instrument is linear to 1241, the manufacturer does not make that claim. The laboratory needs to demonstrate the accuracy and precision of the analyzer, as well the validation of the patient AMR. Linearity requirements have been eliminated from the CLIA regulations and from the CAP inspection criteria, however, many inspectors continue to feel that linearity studies are a part of good lab practice and should be encouraged. If a lab chooses to continue linearity studies, these studies must fully comply with the calibration/calibration verification requirements of CLIA and/or CAP. The results of lower limit and upper limit of clinically reportable range were total protein (2.1 - 79.9), albumin (1.3 - 39), total bilirubin (0.2 - 106.2), alkaline phosphatase (13 - 6928.2), aspartate aminotransferase (24 - 7446), alanine aminotransferase (13 - 6724.2), gamma glutamyl transpeptidase (16.64 - 9904.2), creatine kinase (15.26 - 4723.8), lactate dehydrogenase (127.66 - 13231.8), creatinine (0.4 - 129.6), blood urea nitrogen (8.67 - 925.8), uric acid (1.6 - 151.2), total cholesterol (48.52 - 3162), triglycerides (36.91 - 3367.8), glucose (31 - 4218), amylase (21 - 6694.2), calcium (3.1 - 118.2), inorganic phosphorus (1.11 - 108), HDL (11.74 - 666), NA (58.3 - 1800), K (1.0 - 69.6), CL (38 - 1230).

  • PDF

노말헥산의 연소특성치의 측정 및 고찰 (The Measurement and Investigation of Combustible Properties for n-Hexane)

  • 하동명
    • 한국안전학회지
    • /
    • 제26권2호
    • /
    • pp.36-41
    • /
    • 2011
  • For the safe handling of n-hexane, the explosion limit at $25^{\circ}C$, the temperature dependence of the explosion limits and the lower flash point were investigated. And AITs(auto-ignition temperatures) by ignition delay time for n-hexane were experimented. By using the literatures data, the lower and upper explosion limits of n-hexane recommended 1.0 Vol% and 8.0 Vol%, respectively. In this study, the lower flash points of n-hexane recommended $-23^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659-78 apparatus for n-hexane, and the experimental AIT of n-hexane was $240^{\circ}C$. The new equations for predicting the temperature dependence of the explosion limits of n-hexane is proposed. The values calculated by the proposed equations were a good agreement with the literature data.

Bounds on the Overflow Probability in Jackson Networks

  • 이지연
    • 한국통계학회:학술대회논문집
    • /
    • 한국통계학회 2000년도 추계학술발표회 논문집
    • /
    • pp.109-113
    • /
    • 2000
  • We consider the probability that the total population of a Jackson network exceeds a given large value. By using the relation to the stationary distribution, we derive upper and lower bounds on this probability. These bounds imply the stronger logarithmic limit than that in Glasserman and Kou(1995) when several nodes have the same maximal load.

  • PDF

안면신경마비 환자의 재건에 관한 증례보고 (A CASE REPORT OF RECONSTRUCTION OF FACIAL PARALYZED PATIENT)

  • 최문기
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권3호
    • /
    • pp.288-297
    • /
    • 2005
  • Rehabilitation of the paralyzed face as a result of trauma or surgery remains a daunting task. Complete restoration of emotionally driven symmetric facial motion is still unobtainable, but current techniques have enhanced our ability to improve this emotionally traumatic deficit. Problems of mass movement and synkinesis still plague even the best reconstructions. The reconstructive techniques used still represent a compromise between obtainable symmetry and motion at the expense of donor site deficits, but current techniques continue to refine and limit this morbidity. In chronically paralyzed face, direct nerve anastomosis, nerve graft, or microvascular-muscle graft is not always possible. In this case, regional muscle transposition is tried to reanimate the eyelid and lower face. Regional muscle includes maseeter muscle, temporalis muscle and anterior belly of the digastric muscle. Temporalis muscle is preferred because it is long, flat, pliable and wide-motion of excursion. In order to reanimate the upper and lower eyelid, Upper eyelid Gold weight implantion and lower eyelid shortening and tightening is mainly used recently, because this method is very simple, easy and reliable.

동적 도착의 총 납기 지연 최소화 문제 (A Batching Problem to minimize the total Tardiness with Dynamic Arrivals)

  • 오세호;이근부;양희중
    • 산업경영시스템학회지
    • /
    • 제28권1호
    • /
    • pp.92-96
    • /
    • 2005
  • This paper deals with a batch processor model in which the batch processing times depend on the jobs assigned to the batch. Each job has a distinct processing time which is determined as not the exact value but the range from the lower limit to the upper, which makes it possible to group several jobs into the same batch. In point of this flexibility our model can be referred to as the generalization of the bum-in model in which the upper limit of each job is unbounded. The jobs to be scheduled may be available nonsimultaneously. Therefore they have different ready times. We develop the model to describe the problem situation and the heuristic methods to minimize the total tardiness. And our batching rule is compared with other dispatching ones.