• Title/Summary/Keyword: Upper/Lower Limit

Search Result 357, Processing Time 0.025 seconds

Reliability of Combustion Properties of MSDS(Material Safety Data Sheet) of tert-Amylalcohol(TAA) (tert-Amylalcohol(TAA)의 물질안전보건자료(MSDS) 연소특성치의 신뢰도)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.17-24
    • /
    • 2019
  • The combustion properties of the flammable substance used in industrial fields include lower/upper flash point, lower/upper explosion limit, autoignition temperature(AIT), fire point, and minimum oxygen concentration(MOC) etc.. The accurate assessment of these characteristics should be made for process and worker safety. In this study, tert-amylalcohol(TAA), which is widely used as a solvent for epoxy resins, oxidizers of olefins, fuel oils and biomass, was selected. The reason is that there are few researches on the reliability of combustion characteristics compared to other flammable materials. The flash point of the TAA was measured by Setaflash, Pensky-Martens, Tag, and Cleveland testers. And the AIT of the TAA was measured by ASTM 659E. The lower/upper explosion limits of the TAA was estimated using the measured lower/upper flash points by Setaflash tester. The flash point of the TAA by using Setaflash and Pensky-Martens closed-cup testers were experimented at 19 ℃ and 21 ℃, respectively. The flash points of the TAA by Tag and Cleveland open cup testers were experimented at 28 ℃ and 34 ℃, respectively. The AIT of the TAA was experimented at 437 ℃. The LEL and UEL calculated by using lower and upper flash point of Setaflash were calculated at 1.10 vol% and 11.95 vol%, respectively.

The Measurement and Investigation of Fire and Explosion Characteristics of Isopropyl Alcohol (이소프로필 알코올의 화재 및 폭발 특성치의 측정 및 고찰)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.3
    • /
    • pp.8-15
    • /
    • 2012
  • For the safe handling of isopropyl alcohol, the explosion limits were investigated. The lower flash points, upper flash points, fire point, and AITs(autoignition temperatures) by ignition time delay for isopropyl alcohol were experimented. By using literature data, the lower and upper explosion limits of isopropyl alcohol were recommended as 2.0 and 12.0 vol%, respectively. The lower flash points of isopropyl alcohol were experimented $12{\sim}14^{\circ}C$ by using closed-cup tester and $18{\sim}19^{\circ}C$ by using open cup tester. And the upper flash points of isopropyl alcohol was experimented $38^{\circ}C$ by using Setaflash closed-cup tester. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus was $463^{\circ}C$.

Atypical Coarctation in the Descending Thoracic Aorta: Treated by Bypass Graft (만성 비특이성 동맥염에 의한 비전형적 하행 흉대동맥 협착증: Bypass graft 를 시행한 1예)

  • Jang, Un-Ha;Yu, Hoe-Seong
    • Journal of Chest Surgery
    • /
    • v.11 no.1
    • /
    • pp.81-84
    • /
    • 1978
  • A 15 years Old girl was admitted with chief complaints of intermittent claudication of lower extremity, dizziness, and headache for 5 years. On admission, malignant hypertension was noted in the upper part of body [190-150/120-110] but femoral & dorsalis pedis pulse could not palpate. Once she had experienced C. V. A. due to hypertension of upper part, about years ago. On auscultation, systolic murmur was audible along the left sternal border. E.C.G. Showed left ventricular hypertrophy pattern, and others within normal limit. Retrograde aortography demonstrated diffuse narrowing of entire thoracic aorta with underdeveloped lower abdominal aorta [below the renal artery] & both common lilac artery, and rich collaterals, but normally visualized greater arteries in the aortic arch. On left posterolasteral thoracotomy, entire descending thoracic aorta revealed marked narrowing with mild perivascular adhesion, but no mediastinal pleura adhesion. These findings suggest as congenital type of atypical coarctation in the entire thoracic aorta with mild secondary change. But histopathology was showed the findings of chronic non-specific aortitis, later. Dacron by pass graft was performed with end to side anastomosis between graft and aortic wall. After operation, all her preoperative symptoms & signs were disappeared, and discharged with good general condition.

  • PDF

P-value significance level test for high-performance steel fiber concrete (HPSFC)

  • Abubakar, Abdulhameed U.;Akcaoglu, Tulin;Marar, Khaled
    • Computers and Concrete
    • /
    • v.21 no.5
    • /
    • pp.485-493
    • /
    • 2018
  • Statistical analysis has found useful application in the design of experiments (DOE) especially optimization of concrete ingredients however, to be able to apply the concept properly using computer aided applications there has to be an upper and lower limits of responses fed to the system. In this study, the production of high-performance steel fiber concrete (HPSFC) at five different fiber addition levels by volume with two aspect ratios of 60 and 83 were studied under two curing methods completely dry cured (DC) and moist cured (MC) conditions. In other words, this study was carried out for those limits based on material properties available in North Cyprus. Specimens utilized were cubes 100 mm size casted and cured for 28 days and tested for compressive strength. Minitab 18 statistical software was utilized for the analysis of results at a 5 per cent level of significance. Experimentally, it was observed that, there was fluctuation in compressive strength results for the two aspect ratios and curing regimes. On the other hand P-value hypothesis evaluation of the response showed that at the stated level of significance, there was a statistically significant difference between dry and moist curing conditions. Upper and lower limit values were proposed for the response to be utilized in DOE for future studies based on these material properties. It was also suggested that for a narrow confidence interval and accuracy of the system, future study should increase the sample size.

A Wind Turbine Simulator for Doubly-Fed Induction-type Generator with Automatic Operation Mode Change during Wind Speed Variation (가변 풍속시 운전모드 절환을 고려한 이중여자 유도형 풍력발전기의 시뮬레이터)

  • Song, Seung-Ho;Sim, Dong-Joon;Jeong, Byoung-Chang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.349-360
    • /
    • 2006
  • Controller for doubly-fed induction-type wind generation system should be designed with mechanical power on blade. The controller in this paper consists of upper level controller and lower level controller. The upper level controller determines operating modes according to mechanical input power and calculates proper reference values. There are 4 operating modes - minimum speed control, variable torque control, torque limit control and idle mode. The lower level controller performs current regulated PWM control of rotor-side converter and grid-side inverter. A wind turbine simulator is implemented using doubly-fed induction-type generator and DSP based back-to-back converter to verify the performance of designed controller experimentally.

A Study of the Presence of Carbonic Acid and Other Potentially Hazardous Substances in Cheongsong Mineral Water (청송약수의 탄산과 유해 가능성 물질 존재에 관한 연구)

  • Lee, Sung-Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.34 no.1
    • /
    • pp.132-136
    • /
    • 2021
  • The purpose of this study is to measure the levels of eluted and dissolved CO2, and CO, volatile organic substances and radiation composition of Cheongsong mineral water which were collected from November 2019 to July 2020 during the autumn, spring, and summer seasons at collection points located in the upper, middle and lower spring waters. Data of the upper, middle and lower spring waters include the following: the amount of eluted water (average value±standard deviation, mL/min) was 30.07±0.52, 15.03±0.16, 23.73±0.42, and the amount of CO2 gas was 1,000 ppm or more. In addition, there was no detection of CO or total volatile organic substances (TVOC) and the radiation dose was 0.08 to 0.13. μSv/h. A blank test value of 0.08 to 0.10 μSv/h, when compared with the median value, showed a high value of 0.02 μSv/h, and the uranium test results provided by the Cheongsong-gun Office were 0.0118 mg/L (date 2019.06.18) and 0.0091 mg/L (date 2020.06.04.) respectively, which was less than the permission limit of 0.03 mg/L. However, it is believed that further research using more precise devices is needed in order to guarantee the safety and health of the water.

Principal Components Regression in Logistic Model (로지스틱모형에서의 주성분회귀)

  • Kim, Bu-Yong;Kahng, Myung-Wook
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.4
    • /
    • pp.571-580
    • /
    • 2008
  • The logistic regression analysis is widely used in the area of customer relationship management and credit risk management. It is well known that the maximum likelihood estimation is not appropriate when multicollinearity exists among the regressors. Thus we propose the logistic principal components regression to deal with the multicollinearity problem. In particular, new method is suggested to select proper principal components. The selection method is based on the condition index instead of the eigenvalue. When a condition index is larger than the upper limit of cutoff value, principal component corresponding to the index is removed from the estimation. And hypothesis test is sequentially employed to eliminate the principal component when a condition index is between the upper limit and the lower limit. The limits are obtained by a linear model which is constructed on the basis of the conjoint analysis. The proposed method is evaluated by means of the variance of the estimates and the correct classification rate. The results indicate that the proposed method is superior to the existing method in terms of efficiency and goodness of fit.

Simulation for Small Lamellar Grating FTIR Spectrometer for Passive Remote Sensing

  • Chung, You Kyoung;Jo, Choong-Man;Kim, Seong Kyu;Kim, In Cheol;Park, Do-Hyun;Bae, Hyo-Yook;Kang, Young Il
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.669-677
    • /
    • 2016
  • A miniaturized FTIR spectrometer based on lamellar grating interferometry is being developed for passive remote-sensing. Consisting of a pair of micro-mirror arrays, the lamellar grating can be fabricated using MEMS technology. This paper describes a method to compute the optical field in the interferometer to optimize the design parameters of the lamellar grating FTIR spectrometer. The lower limit of the micro-mirror width in the grating is related to the formation of a Talbot image in the near field and is estimated to be about $100{\mu}m$ for the spectrometer to be used for the wavelength range of $7-14{\mu}m$. In calculating the far field at the detection window, the conventional Fraunhofer equation is inadequate for detection distance of our application, misleading the upper limit of the micro-mirror width to avoid interference from higher order diffractions. Instead, the far field is described by the unperturbed plane-wave combined with the boundary diffraction wave. As a result, the interference from the higher order diffractions turns out to be negligible as the micro-mirror width increases. Therefore, the upper limit of the micro-mirror width does not need to be set. Under this scheme, the interferometer patterns and their FT spectra are successfully generated.

Cost-effectiveness Outcomes of the National Gastric Cancer Screening Program in South Korea

  • Cho, Eun;Kang, Moon Hae;Choi, Kui Son;Suh, MiNa;Jun, Jae Kwan;Park, Eun-Cheol
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2533-2540
    • /
    • 2013
  • Background: Although screening is necessary where gastric cancer is particularly common in Asia, the performance outcomes of mass screening programs have remained unclear. This study was conducted to evaluate cost-effectiveness outcomes of the national cancer screening program (NCSP) for gastric cancer in South Korea. Materials and Methods: People aged 40 years or over during 2002-2003 (baseline) were the target population. Screening recipients and patients diagnosed with gastric cancers were identified using the NCSP and Korea Central Cancer Registry databases. Clinical outcomes were measured in terms of mortality and life-years saved (LYS) of gastric cancer patients during 7 years based on merged data from the Korean National Health Insurance Corporation and National Statistical Office. We considered direct, indirect, and productivity-loss costs associated with screening attendance. Incremental cost-effectiveness ratio (ICER) estimates were produced according to screening method, sex, and age group compared to non-screening. Results: The age-adjusted ICER for survival was 260,201,000-371,011,000 Korean Won (KW; 1USD=1,088 KW) for the upper-gastrointestinal (UGI) tract over non-screening. Endoscopy ICERs were lower (119,099,000-178,700,000 KW/survival) than UGI. To increase 1 life-year, additional costs of approximately 14,466,000-15,014,000 KW and 8,817,000-9,755,000 KW were required for UGI and endoscopy, respectively. Endoscopy was the most cost-effective strategy for males and females. With regard to sensitivity analyses varying based on the upper age limit, endoscopy NCSP was dominant for both males and females. For males, an upper limit of age 75 or 80 years could be considered. ICER estimates for LYS indicate that the gastric cancer screening program in Korea is cost-effective. Conclusion: Endoscopy should be recommended as a first-line method in Korea because it is beneficial among the Korean population.

Large-scale and small-scale self-excited torsional vibrations of homogeneous and sectional drill strings

  • Gulyayev, V.I.;Glushakova, O.V.
    • Interaction and multiscale mechanics
    • /
    • v.4 no.4
    • /
    • pp.291-311
    • /
    • 2011
  • To simulate the self excited torsional vibrations of rotating drill strings (DSs) in vertical bore-holes, the nonlinear wave models of homogeneous and sectional torsional pendulums are formulated. The stated problem is shown to be of singularly perturbed type because the coefficient appearing before the second derivative of the constitutive nonlinear differential equation is small. The diapasons ${\omega}_b\leq{\omega}\leq{\omega}_l$ of angular velocity ${\omega}$ of the DS rotation are found, where the torsional auto-oscillations (of limit cycles) of the DS bit are generated. The variation of the limit cycle states, i.e. birth (${\omega}={\omega}_b$), evolution (${\omega}_b<{\omega}<{\omega}_l$) and loss (${\omega}={\omega}_l$), with the increase in angular velocity ${\omega}$ is analyzed. It is observed that firstly, at birth state of bifurcation of the limit cycle, the auto-oscillation generated proceeds in the regime of fast and slow motions (multiscale motion) with very small amplitude and it has a relaxation mode with nearly discontinuous angular velocities of elastic twisting. The vibration amplitude increases as ${\omega}$ increases, and then it decreases as ${\omega}$ approaches ${\omega}_l$. Sectional drill strings are also considered, and the conditions of the solution at the point of the upper and lower section joints are deduced. Besides, the peculiarities of the auto-oscillations of the sectional DSs are discussed.