• 제목/요약/키워드: Unutilized heat

검색결과 46건 처리시간 0.021초

LCC 분석에 의한 하천수 미활용에너지 이용시스템의 경제성 평가 (Life-Cycle Analysis of the River Water Unutilized Energy System)

  • 박일환;윤형기;장기창;박준택;박성룡
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.596-604
    • /
    • 2005
  • This paper presents the work on evaluating the LCC (Life-Cycle Cost) of a heat pump system as unutilized energy system. The river water as an unutilized energy source was used for the heat source of heat pump system. LCC analysis is a concrete method for evaluating the economical efficiency of energy facilities of building. The present case study shows an example of adequate use of the LCC analysis on a heat pump system and conventional gas boiler and refrigerator for building heat supply. A life cycle of 20 years was used to calculated net present value of energy cost. Over a 20 year life cycle, the energy cost could be reduced by 612 million won if a heat pump system were used instead of a conventional boiler and an absorption refrigerator.

100RT급 하수열원 냉난방시스템 적용 (Application for Heating and Cooling System Using Sewage Water)

  • 장기창;윤형기;박성룡;백영진;나호상;신광호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.215-220
    • /
    • 2006
  • Along with socioeconomic development and improving standard of living, the heat demand for heating and cooling in residential and commercial sectors is expected to expand rapidly, reaching over 43 million TOE by 2010 in Korea(about 80% increase compared with that in 1995). Since most of this heat demand is loop temperature below $60^{\circ}C$, the utilization of 'unused energy' is surely one of very effective measures to both environmental preservation and energy conservation. 'Unused energy' in this paper is implicated as 'temperature differential energy' available from treated sewage water, useful and abundant heat source for heat pump(cooler in summer and warmer in winter than outside air). An analysis was carried out to estimate the energy potential of treated sewage water for heat pump heat source. Some analysis were taken to study the characteristics of a heat pump system using the treated sewage water as heat source.

  • PDF

중고온 히트파이프를 이용한 열회수기술에 관한 연구 (Technology of Waste Heat Recovery Using Heat Pipe Heat Exchanger for Industrial Practice)

  • 이영수;김종률;장기창;백영진
    • 설비공학논문집
    • /
    • 제16권11호
    • /
    • pp.1044-1050
    • /
    • 2004
  • The present study has been conducted to develop a heat pipe heat exchanger for middle-high temperature ranged from 300 to $600^{\circ}C$. Heat transfer rate, overall heat transfer coefficient and temperature effectiveness were investigated using a heat pipe heat exchanger with Dowtherm A as working fluid. Theoretical analysis was also conducted, and the followings were obtained: (1) Heat exchange rate increased as waste gas temperature supplied to evaporator and frontal velocity in condenser increased, (2) Overall heat transfer coefficient increased by $3{\sim}7\%$ as frontal velocity in evaporator and condenser increased, (3) Temperature effectiveness was about $30\%$ in evaporator and was about $40\%$ in condenser, (4) Heat recovery rate was about $38\%$, (5) Pressure drop did not exceed $8\;mmH_{2}O$ under the running condition of $1{\sim}3Nm/s$, (6) Simulation results were corresponded with experimental results.

미활용 열에너지의 집단에너지 주민 수용성에 관한 연구 (A Study on Residents' Acceptance of Unutilized Heat in District Heating)

  • 원두환;오세신
    • 자원ㆍ환경경제연구
    • /
    • 제32권3호
    • /
    • pp.191-215
    • /
    • 2023
  • 본 연구는 미활용 열에너지를 집단에너지 열원으로 활용할 경우 주민 수용성을 비교 평가하는 것에 초점을 두고 있다. 열 부문 탄소중립에 있어 중요한 수단인 미활용 열에너지는 원활한 보급을 위해 주민 수용성의 확보가 중요하기 때문이다. 난방 소비자를 대상으로 한 설문조사를 통해 미활용 열에너지에 대한 인식조사를 수행하였으며, 컨조인트 모형을 이용해 소각열과 수열, 데이터센터 폐열을 기존의 가스 열원과 지불의사액을 평가해 비교하였다. 분석결과 제시된 미활용 열에너지의 보급 활성화가 중요하다고 인식하면서도 미활용 소각열에 비해서 수열과 데이터센터 폐열에 선호도가 높음을 확인하였다.