• 제목/요약/키워드: Unsteady flow measurement

검색결과 115건 처리시간 0.024초

저속 횡 이동하는 선박의 선체에 작용하는 유체력에 관한 연구 (A Study of Hydrodynamic Forces Acting on a Ship Hull Under Lateral Low Speed Motion)

  • 이윤석;김순갑
    • 한국항해학회지
    • /
    • 제23권2호
    • /
    • pp.29-42
    • /
    • 1999
  • An accurate method of estimating ship maneuverability needs to be developed to evaluate precisely and improve the maneuverability of ships according to the water depth. In order to estimate maneuverability by a mathematical model. The hydrodynamic forces acting on a ship hull and the flow field around the ship in maneuvering motion need to be estimated. The ship speed new the berth is very low and the fluid flow around a ship hull is unsteady. So, the transient fluid motion should be considered to estimate the drag force acting on the ship hull. In the low speed and short time lateral motion, the vorticity is created by the body and grow up in the acceleration stage and the velocity induced by the vorticity affect to the body in deceleration stage. For this kind of problem, CFD is considered as a goof tool to understand the phenomena. In this paper, the 2D CFD code is used for basic consideration of the phenomena to solve the flow in the cross section of the ship considering the ship is slender and the water depth is large enough. The flow fields Added and hydrodynamic forces for the some prescribed motions are computed and compared with the preliminary experiment results. The comparison of the force with measurement is shown a fairly good agreement in tendency. The 3D Potential Calculation based on the Hess & Smith Theory is employed to predict the surge, sway added mass and yaw added moment of inertia of hydrodynamic coefficients for M/V ESSO OSAKA according to the water depth. The results are also compared with experimental data. Finally, the sway added mass of hydrodynamic coefficients for T/S HANNARA is suggested in each water depth.

  • PDF

특별피난계단 부속실 제연설비의 방연풍속 측정 방법에 관한 연구 (Study on Measurement Method of Air Egress Velocity in Vestibule of Smoke Control System)

  • 이수경;홍대화
    • 한국화재소방학회논문지
    • /
    • 제25권3호
    • /
    • pp.85-90
    • /
    • 2011
  • 본 연구는 국내 고층건물 특별피난계단의 부속실에 설치되는 급기가압 제연시스템에서 화재 발생 시 피난을 위하여 출입문이 개방되었을 경우 형성되는 방연풍속의 특성을 FDS를 이용하여 해석하였고, 해석 결과를 분산분석으로 기류의 특성에 따른 측정 방안을 분석하고자 한다. 부속실과 같은 구획공간의 설계 조건에서 급기댐퍼에서 토출되는 보충량은 심한 와류를 형성하고 형성된 와류의 범위 안에 출입문이 존재할 경우 비정상적인 기체의 유동이 출입문지점에 발생한다는 것을 선행연구를 통하여 확인할 수 있었다. 국가화재안전기준 NFSC 501A에서 방연풍속을 측정할 때에는 출입문의 개방에 따른 개구부를 대칭적으로 균등 분할하는 10 이상의 지점에서 측정하는 풍속의 평균치로 할 것으로 정하고 있으나 이러한 조건에서는 출입구 상부 지점에 기류의 유입 현상을 파악하기 어렵고 풍속의 편차가 심하기 때문에 측정점을 공기조화설비의 시험조정 평가 기술기준에서 제시하는 64점 이상으로 세분화하여 측정하여야 할 것이다.

계단형 보에서의 파형 난류 흐름 수치모의 (Numerical Modeling of Wave-Type Turbulent Flow on a Stepped Weir)

  • 백중철;이남주;윤영호
    • 대한토목학회논문집
    • /
    • 제37권3호
    • /
    • pp.575-583
    • /
    • 2017
  • 계단형 보와 여수로 같은 수공구조물의 상부에서는 스키밍 흐름 그리고 직하류부에서는 정상파를 포함하는 도수 현상인 파형흐름과 같이 다양한 형태의 흐름이 발생한다. 연구에서는 하이브리드 RANS-LES 난류 모델링 기법과 자유수면 변동을 해석하기 위한 VOF (volume of fluid)기법을 병합한 3차원 부정류 수치모형을 이용하여 계단형 보가 설치된 사각형 개수로에서 발생하는 파형흐름과 스키밍 흐름을 포함하는 난류흐름을 수치모의 하였다. 시간평균 수치모의 결과와 기존 수리모형 실험 결과를 비교분석한 결과, 수치모의는 보 하류부에서의 평균유속분포의 변화, 정체파와 수면와류를 포함하는 파형흐름의 전반적인 수면 변화, 파형흐름의 파고와 길이, 정체파 하부에서 발생하는 재순환 흐름 영역의 길이 등을 양호하게 잘 재현하는 것으로 나타났다. 수치모의를 통해서 자유수면과 순간 유속 벡터의 변동, 전단응력과 난류에너지의 분포 그리고 3차원 난류조직구조와 총압력분포의 형태와 변동 자료를 제시하여 스키밍 흐름과 파형흐름 영역에서의 독특한 흐름 거동 특성을 규명하였다.

고해상도 Cinematic PIV의 개발 (Development of a High Resolution Digital Cinematic Particle Image Velocimetry)

  • 박경현;김경천
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1535-1542
    • /
    • 2001
  • A high resolution digital cinematic Particle Image Velocimetry(PIV) has been developed. The system consists of a high speed CCD camera, a continuous Ar-ion laser and a computer with camera controller. To improve the spatial resolution, we adopt a Recursive Technique for velocity interrogation. At first, we obtain a velocity vector fur a larger interrogation window size based on the conventional two-frame cross-correlation PIV analysis using the FFT algorithm. Based on the knowing velocity information, more spatially resolved velocity vectors are obtained in the next iteration step with smaller interrogation windows. When the correct velocity vector at the first step is found to be critical, a Multiple Correlation Validation(MCV) technique is applied to decrease the spurious vectors. The MCV technique turns out to improve SNR(Signal to Noise Ratio) of the correlation table. The developed cinematic PIV method has been applied to the measurement of the unsteady flow characteristics of a Rushton turbine mixer. A total of 3,245 instantaneous velocity vectors were successfully obtained with 4 ms time resolution. The acquired spatial resolution corresponds to the conventional high resolution digital PIV system using a 1K ${\times}$ 1K CCD camera.

스파이크가 부착된 유도탄의 공력 가열 해석 (Aerodynamic Heating Analysis of Spike-Nosed Missile)

  • 정석영;윤성준;변우식;안창수
    • 한국군사과학기술학회지
    • /
    • 제7권3호
    • /
    • pp.21-29
    • /
    • 2004
  • Numerical analysis of aerodynamic heating for KPSAM is performed using aerodynamic heating model suitable to KPSAM, which has complex flow field resulting from the spike attached to the dome, such as large separation area and the strong shock/boundary layer interaction region around reattachment point on the dome. The aerodynamic heating model is validated and modified through the comparison between the flight test measurement and the thermal analysis results. TFD temperature sensors are installed on the dome to measure surface temperature during the flight. Computation results, obtained from the heat transfer analysis on the sensors, agree well with flight test data. The aerodynamic heating model provides heat transfer rate into surface as a boundary condition of unsteady 1D/axisymmetric thermal analysis on the missile structure. The axisymmetric thermal analysis using FLUENT is more versatile than the 1D analysis and can be applied to the heating problem related with complex structures and multi-dimensional heat transfer problems such as prediction of temperature rise at contact surface of different materials.

HPG로 산정한 합류부 배수영향 구간의 유량 평가 (An Evaluation of River Discharge Estimates in a Junction with Backwater effect using Interpolated Hydraulic Performance Graph)

  • 김지성;김원
    • 대한토목학회논문집
    • /
    • 제38권6호
    • /
    • pp.831-838
    • /
    • 2018
  • 본 논문에서는 합류부 배수영향을 받는 지점에서 유량을 산정할 수 있는 방법을 제안하였다. 먼저, 최근 2개의 홍수사상에 대한 HEC-RAS 부정류 모의를 수행하여 모형을 보정하였으며, 관심구간 상하류 수위와 유량과의 관계 그래프를 작성하고 크리깅 보간을 수행함으로써 HPG (Hydraulic Performance Graph)를 작성하였다. 대상 홍수기간 동안 HPG와 상하류 연속 수위 자료를 이용하여 구간 유량을 산정하였고, ADVM 같은 자동유량측정 자료와 비교하여 비교적 잘 일치하는 것을 확인하였다. 본 연구결과는 수위-유량 관계곡선의 이력현상이 큰 배수영향 구간에서 유량을 산정하는데 경제적이고 실용적인 방법을 제공할 것이다.

수리모형(RMA-2)을 이용한 팔당호의 유속분포 모의실험 (Simulation of Velocity Distribution in the Lake "Paldang" using the RMA-2 Model)

  • 신동석;권순국
    • 한국환경농학회지
    • /
    • 제18권1호
    • /
    • pp.18-23
    • /
    • 1999
  • 팔당호의 수심측량자료와 1997년의 유출${\cdot}$입 유량을 이용하여 RMA-2 수리모형의 팔당호 유속자료를 모의실험한 결과를 정리하면 다음과 같다. 1) 팔당호에 대한 RMA-2 수리모형의 민감도 분석결과 조도계수보다는 난류교환계수가 유속의 변화에 더 민감한 영향을 미치는 것으로 나타났다. 2) 팔당호에 RMA-2를 적용한 결과, 유속의 크기는 완충지역 역할을 하는 경안천 유입부인 남쪽보다는 방류량과 취수량에 영향을 받는 팔당호 북쪽이 10배 정도 크게 계산되었으며, 팔당호 내부의 물의 흐름은 7월까지는 흐름의 방향이 상류에서 하류방향으로 흐르는 정상적인 상태를 보이다가, 7월 이후 유입량이 많아짐에 따라 댐에서의 차단효과 때문에 경안천 및 소내섬 쪽으로 역류를 하는 것으로 나타나 팔당호 내부의 물의 흐름 방향과 지점별 상대적인 크기를 비교할 수 있었다. 3) 팔당호 내부의 역류 현상은 유입량과 유출량이 평형을 이루는 12월까지 지속되며, 특히 소내섬을 중심으로 반시계방향으로 회전하는 현상이 이 시기에 뚜렷하게 나타나, 수질이나 퇴적현상을 예측할 경우 이들을 반드시 고려해야 할 것으로 판단된다. 4) RMA-2모형에 의하여 좀더 정확한 유속을 예측하기 위해서는 실축유속 및 지형자료의 갱신 및 축적이 필요하다.

  • PDF

3차원 곡관에서의 굴절률 일치법을 이용한 맥동 유동의 PIV 측정 (PIV Measurement of Pulsatile Flows in 3D Curved Tubes Using Refractive Index Matching Method)

  • 홍현지;지호성;김경천
    • 대한기계학회논문집B
    • /
    • 제40권8호
    • /
    • pp.511-517
    • /
    • 2016
  • 3차원의 협착 혈관모델을 3D 프린터를 이용하여 제작하였다. 협착부는 관의 중심축에 대하여 대칭인 형태이며, 협착부가 0도인 직관과 10도로 굽어진 관인 두 가지 모델에 대하여 실험을 수행하였다. 협착모델 내부 속도장을 매질에 대한 왜곡 없이 측정하기 위하여 굴절률일치법을 이용하였다. 정량펌프를 사용하여 발생된 맥동유동은 펌프의 회전속도로 세 가지의 속도조건을 조절하였다. 비정상상태의 속도장은 time-resolved PIV 기법을 이용하여 측정되었다. 주기적인 와류의 생성과 이동은 관 내 최대속도 영역과 관련 있으며, 와류의 크기와 위치 및 대칭성은 레이놀즈수와 관의 기하학적 구조에 영향을 받음을 알 수 있었다. 곡선관에서는 협착부 하류에 재순환 영역이 관찰되며, 이는 혈류역학적 관점에서 혈전의 형성과 침착 가능성을 설명해준다.

CFD 해석에 의한 수직형 지열교환기의 성능예측 (A Performance Prediction of a Vertical-type Geothermal Heat Exchanger by CFD Analysis)

  • 우상우;황광일;김종헌;신승호
    • 한국태양에너지학회 논문집
    • /
    • 제27권3호
    • /
    • pp.117-125
    • /
    • 2007
  • This study proposes a CFD(Computational Fluid Dynamics) analysis as a method of verification of the designed-data and a supplement of the insufficient experiences in geothermal system, which shows a rapid growth among the renewable energies. The followings are the results. FLUENT 6.2.12 is used as a CFD tool on this study, with the equations of continuity, motion, energy for unsteady flow through pipes and k-epsilon turbulent model. S-type model which has one borehole with diameter 12m by depth 206m and T-type model which has 3 boreholes with $12m{\times}20m{\times}206m$ are proposed, and also the boundary conditions are described. The temperature differences between temperatures by CFD analysis and by on-site measurement are less than 1.5%, this shows a high reliability of CFD analysis process which this study proposes. After 11 days simulation operated 12 hours interval On/Off mode, it is clearly predicted that the outlet temperatures of geothermal pipes are increased by $1.2^{\circ}C$, and $2.2^{\circ}C$ after 4 months. And the outlet temperatures of geothermal pipes increased with increase of the mass flow rates through the pipes. T-type model shows that the 4m distance between boreholes are reasonable because the temperatures at 2m and 6m from boreholes are nearly same.

냉동 물류 창고 내 도크시스템을 통한 에너지 손실량 분석 (Analysis of Amount of Energy Loss for a Dock System in the Cold Distribution Center)

  • 양성준;김영주;허준;김태성
    • 설비공학논문집
    • /
    • 제29권8호
    • /
    • pp.419-428
    • /
    • 2017
  • In this study, energy loss due to ventilation load in the dock system was analyzed through simulation. Also, flow generated in the dock system of the warehouse was measured using manufactured measuring devices. Numerical simulation was conducted by simulating the most common picking tasks by examining the actual working environment. Incompressible and unsteady turbulent flows were assumed, and the turbulence model was the k-e standard model. Proper grid was selected through grid dependency test. Measurement was conducted using Honeywell and Vaisala sensors, and flow and temperature inside the warehouse were measured and compared with simulation results to validate simulation. When comparing amount of loss occurring in two hours and amount of loss occurring in 15 minutes, docking time of the former was eight times longer but energy loss was 3.8 times lower. Ventilation load occurring during the initial period after opening docking system accounted for a large proportion of total ventilation load. Also, comparing the load when the dock was closed and the load when the truck was parked, ventilation load was significantly higher than load due to heat conduction from the wall. Therefore, in improving the docking system, it is effective to reduce the gap by improving compatibility of the docking system and truck, rather than wall material.