• Title/Summary/Keyword: Unsteady State Flow

Search Result 185, Processing Time 0.025 seconds

Exergy Analysis of On/Off Controlled Heat Pump

  • Jang, Ki-Tae;Nam, Kwan-Woo;Jeong, Sang-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.22-32
    • /
    • 1999
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the unsteady response of a heat pump. First, a basic heat pump cycle is examined at a steady state to show the general trends of exergy variations in each process of the cycle. Entropy generation issue for the heat exchangers is discussed to optimize the heat pump cycle. Secondly, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Thirdly, the exergy destruction rate of the heat pump with On/Off operation is calculated by simulating the thermodynamic states of the working fluid in the condenser and the evaporator. The inefficiency of On/Off operation during the transient period is quantitatively described by the exergy analysis.

  • PDF

Elasto-viscoplastic Dynamic Analysis of Subterranean Storage Cavern for Petroleum Reserve (석유비축을 위한 지하저장공동의 탄.점소성 동적해석)

  • 진지섭;김수석
    • Computational Structural Engineering
    • /
    • v.2 no.2
    • /
    • pp.53-62
    • /
    • 1989
  • In recent times, the subterranean caverns for storing crude oils and oil products are increasingly needed. The elasto-VIScoplastic DYNamic finite element analysis program(VISDYN) has been developed in order to investigate dynamic responses of the storage cavity. And validity of the program is studied through a numerical example. Mohr-Coulomb yield criterion is adopted and associated flow rule is assumed. Geometrically nonlinear behaviour is taken into account using a total Lagrangian formulation. In dynamic deformation reponses, the difference between the steady state displacements and the unsteady state ones by the static analysis can be neglected.

  • PDF

Performance Analysis of Floating Wave Energy Converter by Using CFD (CFD를 이용한 부양식 파력발전 장치의 성능해석)

  • CHOI, Yong-Seok;LIM, Tae-Woo;KIM, You-Taek
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.5
    • /
    • pp.1303-1309
    • /
    • 2015
  • The behavior and flow characteristics of the floating wave energy converter were analyzed by using CFD in this study. The average significant wave height was confirmed as 0.5~2.0m from the Korean coastal sea area. This study was carried out by selecting a range of 1.0~1.6m in the wave height to simulate the operations of realistic wave energy converter system. The principle of a piston wave maker was applied in order to produce periodic wave. The behavior of the wave energy converter and the state of the wave overtopping according to the generated periodic wave were confirmed through the unsteady three-dimensional flow analysis. It was found that the wave overtopping rate according to the generated periodic wave was in range of the 11.6~30.0 kg/s.

Time accurate method for low speed compressible flows using dual time stepping and preconditioning procedure (이중 시간전진법과 Preconditioning을 이용한 저속의 압축성유동에 대한 비정상 해석기법)

  • Choe, Yun-Ho;Gang, Sin-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.788-802
    • /
    • 1998
  • A numerical method using dual time stepping and preconditioning procedure for efficient computations of unsteady low speed compressible flow problems is developed. The time-derivative preconditioning method which is valid at low speed flow conditions cannot maintain temporal accuracy because of the modification of the time-derivative term in Navier-Stokes equations. The dual time stepping procedure is incorporated to enable the time accurate computations and this procedure introduces a pseudo-time derivative in addition to the physical time derivative. At a given physical time, an inner iteration can be carried out until a steady state in pseudo-time is achieved. This will effectively yield a time accurate solution. Computational capabilities of the above algorithm are demonstrated through computation of a variety of practical fluid flows and it is shown that the algorithms is efficient in the essentially incompressible flows and low Mach number compressible flows with heat source.

Quasi-steady State Simulation of Rotating Detonation Engine

  • Niyasdeen, Mohammed;Oh, Sejong;Kim, Kui Soon;Choi, Jeong-Yeol
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.4
    • /
    • pp.548-559
    • /
    • 2015
  • We performed a numerical simulation based on the two-dimensional (2-D) unsteady Euler's equation with a single-step Arrhenius reaction model in order to investigate the detonation wave front propagation of an Argon (Ar) diluted oxy-hydrogen mixture ($2H_2+O_2+12Ar$). This simulation operates in the detonation frame of reference. We examine the effect of grid size and the performance impact of integrated quantities such as mass flow. For a given set of baseline conditions, the minimal and maximum grid resolutions required to simulate the respective detonation waves and the detonation cell structures are determined. Tertiary shock wave behavior for various grids and pre-exponential factors are analyzed. We found that particle fluctuation can be weakened by controlling the mass flow going through the oblique shock waves.

Numerical Simulation of friction Stir Spot Welding Process with AA5083-H18 (AA5083-H18 판재의 마찰 교반 점 용접 공정에 대한 전산 해석)

  • Kim, Don-Gun;Badarinarayan, Harsha;Ryu, Ill;Kim, Ji-Hoon;Kim, Chong-Min;Okamoto, Kazutaka;Wagoner, R.H.;Chung, Kwan-Soo
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.458-461
    • /
    • 2009
  • Thermo-mechanical simulation of the Friction Stir Spot Welding (FSSW) processes was performed for the AA5083-H18 sheets, utilizing commercial Finite Element Method (FEM) and Finite Volume Method (FVM) which are based on Lagrangian and Eulerian formulations, respectively. The Lagrangian explicit dynamic FEM code, PAM-CRASH, and the Eulerian Computational Fluid Dynamics (CFD) FVM code, STAR-CD, were utilized to understand the effect of pin geometry on weld strength and material flow under the unsteady state condition. Using FVM code, material flow pattern near the tool boundary was analyzed to explain the weld strength difference between the weld by cylindrical pin and the weld by triangular pin, while the frictional energy concept using the FEM code had limitation to explain the weld strength difference.

  • PDF

Natural Convection Coupled with Thermal Radiation within Partially Open Enclosure (복사열과 부분열림이 자연대류에 미치는 영향에 관한 연구)

  • 노승균;김광선;이재효
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.11
    • /
    • pp.2999-3007
    • /
    • 1994
  • The unsteady numerical simulations have been presented for the laminar natural convection in a partially open compartment. Computations were performed within the domain of the compartment in order to show the thermal radiation and the partially opening effects on the flow fields and heat transfer characteristics. The results were shown for different Planck numbers(0.05~5) and opening ratios(0.25~0.75) being fixed with Ra=$10^5$ and Pr=0.71. Considering the flow which is buoyancy driven from the heated wall, and the buoyancy is not much affected by the further outside region from the opening, the numerical computations have been performed without an outer region by the particular boundary treatments on the flow velocity and temperature at the different partial openings. The confined numerical domain reduced the CPU time and the memory of computer. P-1 approximation of radiative transfer equation was employed with Marshak type boundary conditions along with the pseudo-black body approximation at the partial openings. The numerical results clearly show that the natural convective flow and heat transfer are much affected by increase of thermal radiation particularly from the initial state. When thermal radiation is not much affecting the flow ($PL{\le}1$), it was found that thermal radiation effects are almost negligible.

Experimental Estimation of Shear Stresses at Pier-Front (교각전면부 하상재료의 입도분포에 따른 전단응력 산정에 관한 실험적 연구)

  • Park, Yoon Sung;Kang, Jun Ku;Yeo, Woon Kwang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.429-433
    • /
    • 2004
  • According to researchers, the influential factors of scouring are generally divided into three factors: the flow conditions, the type and position of structures, and the characteristics of bed materials. In addition, scouring is affected by the 3-dimensional turbulent boundaries, the unsteady flow, the movement of sediment in the scour-hole area, the approach flow velocity and depth, the width of bridge foundation/pier, and the particle size of bed materials. However, it is difficult to estimate the scour depth near bridge piers when all conditions are factored in at once. Therefore, for reasonably accurate estimates of scour depth, it is essential to consider sufficiently the flow force and resisting force for scour. That is, to determine the shear stress concerning the bed material distribution is needed. In this study, the experiments were performed under the condition of a steady state of flow. As a result, scouring occurred at velocity ratios of 0.476,$(V/V_c=0.476)$, and the scour depth was increased linearly as the velocity ratio increased. in addition, the average values of shear stress ratio at zero scouring depth in both rectangular and circular piers were approximately 7$(\tau_c/\tau_{approach})$ and in the case for same size bed particle material. The results of this study can be used for the fundamental material for estimating the scour depth of bed materials.

  • PDF

Unsteady Free Convection Flow in Horizontal Channels with Arbitrary Wall Temperatures (임의의 벽면온도에 따른 수평채널에서의 비정상 자연대류운동)

  • Im, Goeng
    • The Journal of Engineering Research
    • /
    • v.1 no.1
    • /
    • pp.23-30
    • /
    • 1997
  • Energy transfer by free convection arises in many engineering applications, such as a hot steam radiator for heating a room, refrigeration coils, electric transformers, heating elements and electronic equipments. Generally unsteady natural convection flow in a horizontal channel with arbitrary wall temperatures and the mathematical and physical basis of convection transport has been considered in general. A physically meaningful exact solution of the problem has been obtained in a closed form by the application of the standard finite sine transform technique. Influences of the governing parameters, the Prandtl number and the Rayleigh number, to bring the flow and heat transfer to final steady states have been discussed separately. For constant values of the arbitray wall temperatures and of the function, determining the average axial velocity, the final steady state is approached in different times respectively for the cases when the Prandtl number Pr>1 and Pr<1. It is also seen that the function, representing the axial temperature gradient, is influenced by none of the governing parameters : but the steady state flow is influenced only by the Rayleigh number. There are, of course, many applications. Free convection strongly influences heat transfer from pipes and transmission lines, as well as from various electronic devices. It is also relevant to the environmental sciences, where it is responsible for oceanic and atmospheric motions, as well as related heat transfer processes.

  • PDF

A numerical study of natural convection in a square enclosure with a circular cylinder for high Rayleigh number (높은 Rayleigh 수에서 원형 실린더가 존재하는 사각형 실린더 내부의 자연대류에 관한 수치적 연구)

  • Yu, Dong-Hun;Yoon, Hyun-Sik;Ha, Man-Yeong;Kim, Byeong-Su
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2744-2749
    • /
    • 2008
  • Numerical calculations are carried out for the natural convection induced by temperature difference between a cold outer square cylinder and a hot inner circular cylinder for Rayleigh number of $Ra=10^7$. This study investigates the effect of the inner cylinder location on the heat transfer and fluid flow. The location of inner circular cylinder ($\delta$) is changed vertically along the center-line of square enclosure. The natural convection bifurcates from unsteady to steady state according to $\delta$. Two critical positions of ${\delta}_{C,L}$ and ${\delta}_{C,U}$ as a lower bound and an upper bound are ${\delta}_{C,L}=0.05$ and ${\delta}_{C,U}=0.18$, respectively. Within the defined bounds, the thermal and flow fields are steady state. When the inner cylinder locates at ${\delta}{\geq}{\delta}_{C,U}$, the space between the upper surface of inner cylinder and the top surface of the enclosure forms a relatively shallow layer where the natural convection characterized as the pure Rayleigh-Benard convection forms alternately the upwelling and downwelling plums, as a result that a series of cells known as Benard cells is derived.

  • PDF