• Title/Summary/Keyword: Unsteady Fluid Flow

Search Result 518, Processing Time 0.027 seconds

Valve Dynamics and Ggas Pressure Pulsation of a Reciprocating Compressor (왕복동식 압축기의 밸브거동 및 압력맥동에 대한 해석적 연구)

  • 이성욱;홍성철;주재만;박철희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.130-135
    • /
    • 1998
  • The Reciprocating compressor are widely used in the refrigeration field for its simplicity in principle and high efficiency. In this work, we developed a mathematical model of a reciprocating compressor. The suction and discharge valves are modeled by the spring-mass-damper systems. The working fluid flow is derived from unsteady Bernoulli's equation. With the design parameters, the valve motions and pressure fluctuations are studied numerically and experimentally.

  • PDF

Direct Numerical Simulation of Aeolian Tones

  • Inoue Osamu
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.75-76
    • /
    • 2003
  • Direct numerical simulation results of aeolian tones generated by a two-dimensional obstacle (circular cylinder, square cylinder, NACA0012 airfoil) in a uniform flow are presented and the generation and propagation mechanisms of the sound are discussed. The unsteady compressible Navier-Stokes equations are solved by a highly-accurate finite difference scheme over the entire region from near to far fields. The direct numerical simulation results are also compared with the results obtained by Curle's acoustic analogy.

  • PDF

The evaluative study of window defrost using Computational Fluid Dynamics (CFD를 이용한 Window Defrosting 평가)

  • Lee, I.S.;Im, H.N;Choi, J.W.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.179-182
    • /
    • 2011
  • The purpose of this study is to evaluate a defrost model for the possibility of defrosting on wheelhouse window and the heat capacity if defrosting nozzle by using the commercial CFD solver FLUENT. A detailed simulation model has been created which contains the defrosting nozzle, window and the interior/exterior forced convection boundary. In this numerical study, the heat and mass transfer coupled during defrosting and investigated the defrost time for different hot gas temperature, external wind speed and temperature condition.

  • PDF

Numerical Study of Interfacial Flows With Immersed Solids (잠겨진 물체를 포함하는 계면유동의 수치적인 연구)

  • Kim, Sung-Il;Son, Gi-Hun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.706-711
    • /
    • 2003
  • A numerical method is presented for computing unsteady incompressible two-phase flows with immersed solids. The method is based on a level set technique for capturing the phase interface, which is modified to satisfy a contact angle condition at the solid-fluid interface as well as to achieve mass conservation during the whole calculation procedure. The modified level set method is applied for numerical simulation of bubble deformation in a micro channel with a cylindrical solid block and liquid jet from a micro nozzle.

  • PDF

Numerical Analysis of Subsurface Flow in a Hillslope (자연 구릉지에서 지표하 흐름의 수치해석)

  • 최은호;남선우
    • Water for future
    • /
    • v.24 no.1
    • /
    • pp.109-117
    • /
    • 1991
  • The governing equation of flow in porous media is developed on the bases of the continuity equation of fluid for transient flow through a saturated-unsaturated zone, and substitution of Darcy's law. The numerical solutions are obtained by finite element method based on the Galerkin principles weighted residuals. The analysis are carried out by using the unsteady storm data observed and rainfall intensities which are obtained by using the rainfall excess model in considering of the initial losses. The functional relationships between the hydraulic conductivity, capillary pressure head and volumetric water content are applied to the flow of water through unsaturated soil varied with changes of water content.

  • PDF

Saturated - Unsaturated Transient Subsurface Flow Model on a Hillslope

  • Choi, Eun-Ho;Nahm, Sun-Woo
    • Korean Journal of Hydrosciences
    • /
    • v.2
    • /
    • pp.13-24
    • /
    • 1991
  • The governing partial differential equation of flow in porous media is developed on the bases of the continuity equation of fluid for transient flow through a saturated-unsaturated zone, and substitution of Dercy's law. The numerical solution is obtained by the Galerkin finite element method based on the principle of weighted residuals. The analysis is carried out by using the unsteady storm data observed and the functional relationships between the hydraulic conductivities, capillary pressure heads, and volumetric water contents under saturated-unsaturated conditions. As the results the hydraulic conductivities, rates of change of storage and initial moisture conditions are significantly influened on the responses of subsurface flow on a hillslope.

  • PDF

Visualization of the flow between co-rotating disks in shroud with an obstruction (장애물을 포함한 동시회전 디스크 내부의 비정상 유동가시화)

  • 공대위;도덕희;주원구
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1152-1156
    • /
    • 2003
  • Hard disk drives (HDD) in computer are used extensively as data storage capacity. The trend in the computer industry to produce smaller disk drives rotating at higher speeds requires an improved understanding of fluid motion in the space between disks. PIV measurement was used fer the unsteady flow between the center pair of four disks of four times larger than common radius of HDD disk at several rpm in a fixed cylindrical enclosure. The boundary between inner region and outer region is detected using PIV measurement and the number of dominant vortices s determined clearly. Tip vortices generated by an obstruction with actual-like configuration can be found at inner region. Oscillating flow from the obstruction appears at outer region with complex flow pattern.

  • PDF

Simultaneous velocity and temperature measurement of thermo-fluid flows by using particle imaging technique (화상처리기법을 이용한 온도장 및 속도장 동시 측정기법 개발)

  • Lee, Sang-Joon;Baek, Seung-Jo;Yoon, Jong-Hwan;Doh, Deog-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.10
    • /
    • pp.3334-3343
    • /
    • 1996
  • A quantitative flow visualization technique was developed to measure velocity and temperature fields simultaneously in a two-dimensional cross section of thermo-fluid flows. Thermochromic liquid crystal(TLC) particles are used as temperature sensor and velocity tracers. Illuminating a thermo-fluid flow with a thin sheet of white light, the reflected colors from the TLC particles in the flow were captured simultaneously by two CCD cameras; a 3-chip CCD color camera for temperature field measurement and a black and white CCD camera for velocity field measurement. Variations of temperature field were measured by using a HSI true color image processing system and TLC solution. The relationship between the hue values of TLC color image and real temperature was obtained and this calibration curve was used to measure the true temperature under the same camera and illumination condition. The velocity field was obtained by using a 2-frame PTV technique using the concept of match-probability to track true velocity vectors from two consecutive image frames. These two techniques were applied at the same time to the unsteady thermal-fluid flow in a Hele-Shaw cell to measure the temperature and velocity field simultaneously and some results are discussed.

Temperature and Flow Velocity Analysis for Fire in Synthetic Heat Transfer Fluid Boiler (열매유 보일러 내부화재에 따른 온도 및 속도분포 해석)

  • Kim, Yeob-Rae;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.19-25
    • /
    • 2013
  • The fire took place in the synthetic heat transfer fluid boiler. This study uses simulation to investigate the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is more or less unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120 kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The simulation shows that the temperature is $767^{\circ}C$ in the low part of the third pass. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. The temperature rises to $183^{\circ}C$ in the low part of the burner. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner.