• 제목/요약/키워드: Unstable Motion

검색결과 223건 처리시간 0.027초

균형 훈련 플레이트 시스템을 이용한 생체역학적 특성 연구 (Characteristics of ROM and EMG to Balance Training in Unstable Plate System: Primary Study)

  • 전성철;임희철;이창형;김태호;정덕영;전경진
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권5호
    • /
    • pp.235-239
    • /
    • 2015
  • The purpose of this study was to investigate the unstable plate system for the advanced balance ability. 7 male volunteers (age $33.7{\pm}1.2$ years, height $174.7{\pm}3.8cm$, weight $86.0{\pm}3.6kg$, BMI $28.2{\pm}2.0kg/m^2$) performed the partial squat motion on the shape of CAP type(${\cap}$) and BOWL type(${\cup}$) plate system. The range of motion (ROM) and muscle activation were acquired by the motion analysis system and the EMG system. Results of ROMs of the CAP type plate system were shown the widely range of the deviation in the ankle joint on the sagittal plane (sagittal plane - hip joint $10.7^{\circ}$ > $5.4^{\circ}$, knee joint $16.3^{\circ}$ > $6.4^{\circ}$, ankle joint $18.8^{\circ}$ > $6.3^{\circ}$ ; transverse plane - hip joint $3.5^{\circ}$ > $1.8^{\circ}$, knee joint $5.3^{\circ}$ > $3.4^{\circ}$, ankle joint $11.3^{\circ}$ > $5.3^{\circ}$ ; frontal plane - hip joint $0.9^{\circ}$ > $0.5^{\circ}$, knee joint $0.8^{\circ}$ > $0.6^{\circ}$, ankle joint $4.8^{\circ}$ > $3.7^{\circ}$). Muscle activation results of the CAP type plate system were indicated higher in major muscles for balance performance than the BOWL type plate system (vastus lateralis 0.90 > 0.62, peroneus longus 0.49 > 0.21, biceps femoris 0.38 > 0.14, gastrocnemius 0.11 > 0.05). These findings may indicate that the CAP type plate system would expect better effectiveness in perform the balance training. This paper is primary study for developing balance skills enhancement training device.

마커리스 방식의 얼굴 모션캡쳐 데이터 안정화 기법 (The Stabilizing Method for Face Tracking Data from Markerless Motion Capture System)

  • 이준상;이임건
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 춘계학술대회
    • /
    • pp.773-774
    • /
    • 2015
  • 모션캡쳐 기술은 빠른 시간에 움직임을 추적하여 컴퓨터에서 이용할 수 있는 데이터로 기록된다. 모션캡쳐로 얻어진 데이터는 동작을 생성하는 데 있어서 손쉽게 제어할 수 있다. 하지만 키넥트 기반으로 추출된 모션캡쳐 데이터는 불안전한 경우가 많다. 또한 기존의 모션캡쳐 시스템을 활용한 얼굴모션 제작과정은 시간 및 경제적 부담으로 인해 많은 어려움을 갖고 있다. 따라서 본 논문은 키넥트 시스템을 활용하여 얻어진 얼굴 모션캡쳐 데이터에서 부분적 떨림 현상을 일으키는 데이터를 보정하는 방법을 제안한다.

  • PDF

경사면에서 선회운동하는 SUV차량의 롤거동 해석 (A Roll-behavior Analysis of SUV in Turning Motion on a Slope)

  • 방정훈;이병훈
    • 한국자동차공학회논문집
    • /
    • 제22권4호
    • /
    • pp.131-137
    • /
    • 2014
  • The SUV has a risk of rollover because of the highness of center of mass. In this paper the roll-behavior of a SUV in turning motion is analyzed. Dynamic model of the vehicle on the slope is developed and simulation is carried out using the software ADAMS/Car. The results show that the relational expression between the ground force acting on the tire and the roll motion is well established. It is also identified that the driving state of the vehicle becomes unstable at the lower or upper position of the slope.

대화형 감성 로봇의 메커니즘 설계 (Mechanism Design of the Interactive Emotional Robot)

  • 김연훈;윤석준;이동연;곽윤근
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 추계학술대회 논문집
    • /
    • pp.233-238
    • /
    • 2001
  • The mechanism design of the interactive emotional robot has been carried out. The two-wheeled inverted pendulum type mechanism was adopted to improve the mobility and make the innate clumsy monoaxial bicycle motion. Even though the system is unstable in itself, it is expected for the robot to move freely in a plane, keeping the upright position only with two wheels. Two motors attached on head can make 4 motion sets, and two motors on the wheels can make 8. Therefore, 32 independent motion sets can be achieved from the robot to communicate the emotions with humans. The motion's equation of the robot was derived based on nonholonomic dynamics, and the necessary power to the wheel's rotational axis was found by simulation.

  • PDF

날갯짓 비행 로봇의 세로방향 비행 동역학 모델링 및 안정성 해석 (Longitudinal Flight Dynamic Modeling and Stability Analysis of Flapping-wing Micro Air Vehicles)

  • 김중관;한종섭;김호영;한재흥
    • 제어로봇시스템학회논문지
    • /
    • 제21권1호
    • /
    • pp.1-6
    • /
    • 2015
  • This paper investigates the longitudinal flight dynamics and stability of flapping-wing micro air vehicles. Periodic external forces and moments due to the flapping motion characterize the dynamics of this system as NLTP (Non Linear Time Periodic). However, the averaging theorem can be applied to an NLTP system to obtain an NLTI (Non Linear Time Invariant) system which allows us to use a standard eigen value analysis to assess the stability of the system with linearization around a reference point. In this paper, we investigate the dynamics and stability of a hawkmoth-scale flapping-wing air vehicle by establishing an LTI (Linear Time Invariant) system model around a hovering condition. Also, a direct time integration of full nonlinear equations of motion of the flapping-wing micro air vehicle is conducted to see how the longitudinal flight dynamics appear in the time domain beyond the reference point, i.e. hovering condition. In the study, the flapping-wing air vehicle exhibited three distinct dynamic modes of motion in the longitudinal plane of motion: two stable subsidence modes and one unstable oscillatory mode. The unstable oscillatory mode is found to be a combination of a pitching velocity state and a forward/backward velocity state.

불안정한 Neer II형 원위쇄골 골절의 치료에서 Hook 금속판의 이용 (The Use of Hook Plate on the Management of Unstable Neer II Lateral End Fracture of The Clavicle)

  • 고상훈;조성도;박문수;류석우
    • Clinics in Shoulder and Elbow
    • /
    • 제6권2호
    • /
    • pp.131-137
    • /
    • 2003
  • Purpose: Unstable Neer type II lateral end fracture of clavicle may be required operation. The purpose of this study is the effectiveness of the use of Hook plate in the management of unstable Neer type II fractures. We preliminary reported the results of Unstable Neer type II lateral end fracture of clavicle using by Hook plate. Material and Methods: From May 1998 to May 2002, we operated 6 cases unstable Neer type II lateral end fracture of clavicle with Hook plate by one surgeon. We checked radiologic evaluation and disappearance of pain per 1 week, and evaluated improvement of range of motion per 2 week. And we followed up at each interval 3 months,6 months, 12 months and after that per 6months interval, at that each time we checked stress radiogram of shoulder and functional evaluation. The shoulder function was evaluated using Modified Shoulder Rating Scale (MSRC) for Distal Clavicle Fracture and UCLA score. Average follow up was on 37.2 (12∼57) months. Results: All 6 patients were regained satisfactory function. Average MSRC for distal clavicle fracture was 17.3 (15∼20) and average UCLA score was 33.2 (31∼35) at last follow up. Conclusion: There are many advantage of the use of Hook plate on management of unstable Neer II distal clavicle fracture in spite of several disadvantage. There have not yet been reported in our country. So we obtained good to excellent clinical result in surgical treatment of 6 cases on type II displaced lateral end fracture of the clavicle. But we think that more cases will be review and longer follow up will be needed in the future.

근위 상완골 골절 (Proximal Humaral Fractures)

  • 김정우
    • 대한견주관절학회:학술대회논문집
    • /
    • 대한견주관절학회 2007년도 제5차 연수강좌
    • /
    • pp.189-195
    • /
    • 2007
  • $\cdot$ Difficult & Challenging Fracture $\cdot$ Most Treated Nonoperative $\cdot$ ORIF in Young Patients with Unstable Fractures $\cdot$ Fixed Angles Device is Promising $\cdot$ Prosthetic Arthroplasty in Elderly $\cdot$ Loss of Motion Very Common

  • PDF

Comparison of the Duration of Maintained Calf Muscle Flexibility After Static Stretching, Eccentric Training on Stable Surface, and Eccentric Training on Unstable Surfaces in Young Adults With Calf Muscle Tightness

  • Jang, Hee-Jin;Kim, Suhn-Yeop;Jang, Hyun-Jeong
    • 한국전문물리치료학회지
    • /
    • 제21권2호
    • /
    • pp.57-66
    • /
    • 2014
  • The objective of this study was to determine the duration of maintained calf muscle flexibility gained in young adults with calf muscle tightness, as measured by increases in ankle active and passive dorsiflexion range of motion (DFROM) after three stretching interventions. Twenty subjects (5 men and 15 women) with calf muscle tightness received the following three stretching interventions in one leg (assigned at random): static stretching (SS), eccentric training on stable surface (ETS), and eccentric training on unstable surfaces (ETU). The subjects received all three interventions to the same leg, applied in a random order. Each intervention had a break of at least 24 h in-between, in order to minimize any carryover effect. Each intervention used two types of stretching: with the calf muscle stretched and both knees straight, and with the knee slightly bent in order to maximize the activation of the soleus muscle. All three interventions were performed for 200 seconds. We measured the duration of maintained calf muscle flexibility through active and passive ankle DFROM before intervention, immediately after intervention (time 0), and then 3, 6, 9, 15, and 30 min after intervention. We found a difference in the duration of maintained calf muscle flexibility between the three interventions. In the ETS and ETU interventions, a significant improvement in calf muscle flexibility, both ankle active and passive dorsiflexion ranges of motion (ADFROM and PDFROM), was maintained for 30 min. In the SS intervention, however, ADFROM before 9 min and PDFROM before 6 min were statistically different from the baseline. Our results suggest that ETS and ETU may be more effective than SS for maintaining calf muscle flexibility in young adults.

모션센서를 이용한 로봇의 디지털 영상 보정 기술 (Digital Image Stabilization Technique of Robot using Motion Sensor)

  • 오정석;심귀보
    • 한국지능시스템학회논문지
    • /
    • 제19권3호
    • /
    • pp.317-322
    • /
    • 2009
  • 로봇은 일정 속도 이상의 움직임을 가지면 필연적으로 진동을 하기 때문에 장착된 카메라의 경우 이미지가 흔들려 더 이상 로봇의 눈 역할을 수행하지 못하게 된다. 따라서 흔들리는 영상의 안정화를 위한 방법을 연구가 필요해졌다. 영상에서 글로벌 모션 벡터를 계산하여 안정화하는 방법이 존재하지만 이는 프로세서가 처리해야 하는 데이터양이 많아지기 때문에 임베디드 로봇의 사양의 한계로 인하여 실시간으로 영상을 송출하는데 큰 어려움이 있다. 이를 보완하기 위하여 모션벡터를 사용하지 않는 모션센서를 통한 영상 안정화를 제안한다. 모션센서를 통하여 로봇의 진행과 관계없는 움직임을 추출하고 추출한 움직임을 영상에서 제거하는 방법이다.

12주간의 불안정성 신발 착용이 직립 자세 및 보행역학에 미치는 영향 (Effects of 12-week Wearing of the Unstable Shoes on the Standing Posture and Gait Mechanics)

  • 박기란;안송이;이기광
    • 한국운동역학회지
    • /
    • 제16권3호
    • /
    • pp.165-172
    • /
    • 2006
  • The purpose of this study was to determine effects of 12-week wearing of unstable shoe on the standing posture and gait mechanics. Nine healthy men were asked to wear the unstable shoes for 12-week and walk for 30 minute everyday. Their standing posture and gait mechanics were measured before and after treatment. Standing posture was measured for each side(anterior, posterior, lateral) for standing position. And gait analysis was measured joint angle of a right lower limb between first right heel contact and second right heel contact. Kinematic data were collected using video camera at 30 frame per seconds. Statistical analysis was paired t-test(p<.05) to compare before training with after that. A head tilt angle was significantly decreased for posterior side(p<.05). The angle of between center of line and surface was significantly decreased at midstance and take off during walking(p<.05). Ankle dorsiflexion significantly increased at heel contact2(p<.05) and ankle plantarflexion significantly increased at midstance and midswing(p<.05). The increase of ankle dorsiflexion showed that our results consisted with previous study. In conclusion, there was not large significant difference in static standing posture but joint angle of lower limb represented many changes with increasing of ankle motion during walking. These were of benefit to body by increasing leg muscle activity but it was necessary for man having a ankle problem to consider. Further studies concerning optimum outsole angle of unstable shoes are necessary.