• Title/Summary/Keyword: University operating system

Search Result 5,210, Processing Time 0.039 seconds

Heterogeneous Operating Systems Integrated Trace Method for Real-Time Virtualization Environment (다중 코어 기반의 실시간 가상화 시스템을 위한 이종 운영체제 통합 성능 분석 방법에 관한 연구)

  • Kyong, Joohyun;Han, In-Kyu;Lim, Sung-Soo
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.10 no.4
    • /
    • pp.233-239
    • /
    • 2015
  • This paper describes a method that is integrated trace for real-time virtualization environment. This method has solved the problem that the performance trace may not be able to analyze integrated method between heterogeneous operating systems which is consists of real-time operating systems and general-purpose operating system. In order to solve this problem, we have attempted to reuse the performance analysis function in general-purpose operating system, thereby real-time operating systems can be analyzed along with general-operating system. Furthermore, we have implemented a prototype based on ARM Cortex-A15 dual-core processor. By using this integrated trace method, real-time system developers can be improved productivity and reliability of results on real-time virtualization environment.

Study on the Performance Characteristics of the Solar Hybrid System with Heat Pump Operating Temperature during Winter Season (겨울철 열펌프 작동온도에 따른 태양열 하이브리드 시스템의 성능특성에 관한 연구)

  • Kim, Won-Seok;Cho, Hong-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.12
    • /
    • pp.821-827
    • /
    • 2010
  • Study on the performance characteristics of the solar hybrid system with heat pump operating temperature during winter season has performed by using an experimental test. The system performance and operating characteristics with the heat pump operating temperature, hour and load condition were investigated and analyzed. As a result, the hot water temperature was significantly affected by the heat pump operating temperature at the morning(time 1) and noon(time 2). However, hot water temperature was set by the radiation quality and collecting operation hour at the afternoon(time 3). In addition to the solar fraction was decreased for the high heat pump operating temperature because the heat pump operated with a long operating time and short operating period.

Effects of Key Operating Parameters on the Efficiency of Two Types of PEM Fuel Cell Systems (High-Pressure and Low-Pressure Operating) for Automotive Applications

  • Kim Han-Sang;Lee Dong-Hun;Min Kyoungdoug;Kim Minsoo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.4
    • /
    • pp.1018-1026
    • /
    • 2005
  • The proton exchange membrane (PEM) fuel cell system consisting of stack and balance of plant (BOP) was modeled in a MATLAB/Simulink environment. High-pressure operating (compressor type) and low-pressure operating (air blower type) fuel cell systems were con­sidered. The effects of two main operating parameters (humidity and the pressure of the supplied gas) on the power distribution characteristics of BOP and the net system efficiency of the two systems mentioned above were compared and discussed. The simulation determines an optimum condition regarding parameters such as the cathode air pressure and the relative humidity for maximum net system efficiency for the operating fuel cell systems. This study contributes to get a basic insight into the fuel cell stack and BOP component sizing. Further research using muli­object variable optimization packages and the approach developed by this study can effectively contribute to an operating strategy for the practical use of fuel cell systems for vehicles.

Analysis of Economics through Control Method of Heat Source Equipment in Seasonal Air conditioning Building

  • Park, Yool;Kim, Samuel;Jung, Soon-Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.4
    • /
    • pp.209-217
    • /
    • 2003
  • The term “energy saving is economical” is appropriate for the national view point and for design and assessment of one system, but not appropriate when choosing the system by comparing alternative systems in the early design step. Sometimes, non-energy saving system is more economical than energy saving system because of the price of electricity, gas or oil, which are used for operating the air conditioning system. Therefore, when designing a system, we should consider the efficient alternatives through economic assessment of energy saving method. However, research on non-operating number control of the system is not sufficient because it is more common to use operating number control of the system for most economic assessment of air conditioning systems. For this reason, this research can provide the economic operating number control method as basic design data. The data obtained through analysis of life cycle cost based on amount of yearly energy use, are produced by system simulation of HASP/ACLD/8501 and HASP/ACSS/8502 for six alternative heating$.$cooling systems based on seasonal air conditioning system, which is widely used for medium and large size office buildings in Busan.

Trend analysis of Smart TV and Mobile Operating System (모바일 운영체제와 스마트 TV 동향 분석)

  • Bae, Yu-Mi;Jung, Sung-Jae;Jang, Rae-Young;Park, Jeong-Su;Kyung, Ji-Hun;Sung, Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.740-743
    • /
    • 2012
  • The initial role of the operating system acts as an intermediary between the computer and the user, and, hardware and process management, and the convenience of your computer system is to use. Of these operating systems as well as servers and personal computers, smartphones and tablet mounted on mobile devices such as mobile operating system was born. Mobile Operating System has been expanded a TV or Car Area that built into a simple embedded operating system, is emergence of a variety of devices, cloud services, combined with the desire of users due to the high built-in simple embedded operating system that was working on a TV or a car is expanding to the area. The reason for the emergence of a variety of devices, cloud services, combined with the desire of users is high. In this paper, the mobile operating system, N-Screen, Smart TV to find out about and through the analysis of the major smart TV, the future Find out about trends in the mobile operating system.

  • PDF

Evaluating Unity3D Optimization Ways for Mobile Operating System Tizen (모바일 운영체제 Tizen에 대한 Unity 최적화 방안 평가)

  • Kim, Young-Jae;Lee, Sang-Ho
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.6
    • /
    • pp.187-192
    • /
    • 2017
  • The Android operating system currently has a proven method of Unity optimization. However, the Tizen operating system does not know how effective the existing Unity optimization method can be applied to the Tizen operating system and how effective it is. In this paper, we analyze the efficiency of applying Unity optimizing techniques of Android operating system to Tizen operating system. To get this purpose, this study investigates whether the existing Unity optimization method can be applied to Tizen operating system and evaluates the efficiency of the method through Unity Profiler. This research will allow us to further evaluate the Unity optimizations for the existing Android operating system in the future.

Life Cycle Costing through Operating Number Control of Air Conditioning Systems in Office Buildings (사무소 건축물의 공조시스템 대수제어 여부에 따른 LCC 분석)

  • Park, Ryul;Jung, Soon-Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.981-988
    • /
    • 2002
  • Generally, the term "energy saving is economical" is appropriate for the national view point and for design and assessment of one system, but not appropriate when choosing the system by comparing alternative systems in the early design step. Sometimes, non-energy saving system is more economical than energy saving system because of the price of electricity, gas or oil, which are used for operating the air conditioning system. Therefore, when designing the system, we should consider the efficient alternatives through economic assessment of energy saving method. However, research on non-operating number control of the system is not sufficient because it is more common to use operating number control of the system for most economic assessment of air conditioning system. For this reason, this research can provide the economics through operating number control as basic design data. The data obtained through assesment of Life Cycle Cost based on amount of yearly energy use, were produced by system simulation of HASP/ACLD/8501 and HASP/ACSS/8502 for six alternative heating/cooling systems based on constant air volume conditioning system, which is widely used for medium and large office buildings in Busan.

A Study on the Analysis of the Performance and Efficiency of a Low-pressure Operating PEMFC System for Vehicle Applications Using MATLAB/Simulink (MATLAB/Simulink를 이용한 자동차용 상압형 PEM 연료전지 시스템의 성능 및 효율 분석 연구)

  • Park, Raehyeok;Kim, Han-Sang
    • Journal of Hydrogen and New Energy
    • /
    • v.24 no.5
    • /
    • pp.393-400
    • /
    • 2013
  • The air supply system has a significant effect on the efficiency of polymer electrolyte membrane fuel cell (PEMFC) systems. The performance and efficiency of automotive PEMFC systems are greatly influenced by their air supply system configurations. This study deals with the system simulation of automotive PEMFC systems using MATLAB/Simulink framework. In this study, a low-pressure operating PEMFC system adopting blower sub-module (turbo-blower) is modeled to investigate the effects of stack operating temperature and air stoichiometry on the parasitic power and efficiency of automotive PEMFC systems. In addition, the PEMFC net system efficiency and parasitic power of air supply system are mainly compared for the two types (low-pressure operating and high-pressure operating) of automotive PEMFC systems under the same net power conditions. It is suggested that the obtained results from this system approach can be applied for establishing the novel operating strategies for FC vehicles.

A System Operating Algorithm for the Effective Operation of a Multi-type Air-conditioning System (멀티형공조시스템의 효과적인 운전을 위한 시스템운전알고리즘)

  • Han Do-Young;Park Kwan-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.587-595
    • /
    • 2006
  • A system operating algorithm was developed for the effective operation of a multi-type air-conditioning system. The system operating algorithm includes control algorithms for a safety mode, an initial operating mode, a stabilization mode, a fault diagnosis mode, an efficiency mode, and a tracking mode. Various tests were performed to show the effectiveness of these algorithms. Tests showed good results for the operation of a multi-type air-conditioning system. Therefore, these algorithms developed for this study may be used for the effective control of a multi-type air-conditioning system.

Analysis of a Controllable Queueing Model Operating under the Alternating Operating Policies (변동 운용방침이 적용되는 조정가능한 대기모형 분석)

  • Rhee, Hahn-Kyou
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.81-90
    • /
    • 2016
  • Different from general operating policies to be applied for controllable queueing models, two of three well-known simple N, T and D operating policies are applied alternatingly to the single server controllable queueing models, so called alternating (NT), (ND) and (TD) policies. For example, the alternating (ND) operating policy is defined as the busy period is initiated by the simple N operating policy first, then the next busy period is initiated by the simple D operating policy and repeats the same sequence after that continuously. Because of newly designed operating policies, important system characteristic such as the expected busy and idle periods, the expected busy cycle, the expected number of customers in the system and so on should be redefined. That is, the expected busy and idle periods are redefined as the sum of the corresponding expected busy periods and idle periods initiated by both one of the two simple operating policies and the remaining simple operating policy, respectively. The expected number of customers in the system is represented by the weighted or pooled average of both expected number of customers in the system when the predetermined two simple operating policies are applied in sequence repeatedly. In particular, the expected number of customers in the system could be used to derive the expected waiting time in the queue or system by applying the famous Little's formulas. Most of such system characteristics derived would play important roles to construct the total cost functions per unit time for determination of the optimal operating policies by defining appropriate cost elements to operate the desired queueing systems.