• Title/Summary/Keyword: University library air quality

Search Result 11, Processing Time 0.027 seconds

A Study on the Measurement and Investigation of Air Quality in a University Library (대학도서관 실내 공기질 측정 및 조사 연구)

  • Lee, Jae-Won
    • Journal of Korean Library and Information Science Society
    • /
    • v.50 no.4
    • /
    • pp.635-658
    • /
    • 2019
  • In this study, the harmful factors measured in S university's central library were divided into ① air harmful substance ② biological harmful factors ③ carbon monoxide, carbon dioxide, and nitrogen dioxide concentration, measured and analyzed compared to the relevant criteria. The analysis showed that the harmful substances in the air - fine dust, asbestos, volatile organic compounds and formaldehyde - were all lower than the relevant standards, and that biological harmful factors such as fungi in the air, gramophageal bacteria, and endotoxin were also found to have no particular problems. The concentration of carbon monoxide, carbon dioxide, and nitrogen dioxide in the air was also maintained without any unusual factors compared to the concentration in the ordinary atmosphere. However, the library is a multi-use facility that needs regular cleaning and ventilation to manage the environment.

Diurnal Variation of $PM_{10}$ Concentrations in Library and Student Buildings using Scattering Light Integrated Type Digital Dust Indicator (산란광 광량 적산시 Digital Dust Indicator에 의한 도서관과 학생회관내 $PM_{10}$ 농도의 일변화)

  • 김만구;권영진;정영림
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.2
    • /
    • pp.115-122
    • /
    • 1997
  • Diurnal variation of $PM_{10}$ concentration was investigated for 24 sites in library including reading room, bookstock room, lobby, office and so on, and 9 sites in student building at Kangwon National University using scattering light integrated type digital dust indicator. The dimensional conversion factors for mass concentrations (K) were determined by comparing between the $PM_{10}$ concentrations collected by $PM_{10}$ hig volume air sampler and the digital dust indicator. The dimensional conversion factor (K) was 3.33 for indoor air in this experiment. The highest concentrations were 649 $\mug/m^3$/day for smoking room in the library and 242 $\mug/m^3$/day for circle room in the student building. Most of spaces in the library except a office and bookstock rooms were over 150 $\mug/m^3$/day of $PM_{10}$ concentrations and 6 indoor spaces were over the guideline for indoor air quality in student building except a health center and two restaurants. Therefore, it should be required to make an improvement on the indoor air quaility for public facilities in the university buildings.

  • PDF

Impact Assessment of Remodeling Works on Indoor Air Quality in a University Library Building (대학 도서관 건물 리모델링에 따른 실내공기질 영향 평가)

  • Baek, Sung-Ok;Park, Dae-Gwon;Park, Sun-Young;Lee, Yeo-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.6
    • /
    • pp.876-887
    • /
    • 2006
  • Recently, there have been a large number of remodeling (or renovation) works in old buildings in urban areas. Compared to new buildings, environmental risk might be more significant in such buildings where remodeling works are going on, since some parts of the building may still be in service for people. This study was carried out to investigate the impacts of remodeling works on the indoor air quality (IAQ) of a large building (a 22 stories university library). Indoor air monitoring was conducted during and after the remodeling works every two weeks for a one year period, and target compounds included BTEX, styrene, TVOC, carbonyl compounds such as formaldehyde and acetaldehyde. $CO,\;CO_2,\;PM_{10}$, and $PM_{2.5}$. Overall, the IAQ appeared to be recovered within two months after the remodeling works. However, in some places, concentrations of formaldehyde, toluene, xylene. and ethylbenzene showed higher levels even after works than those during the works. The results indicate that painting, glues and office furnitures are major sources of aromatic VOCs and formaldehyde. Therefore, in order to decrease the concentrations of toxic VOCs, the use of environmental-friendly building materials is strongly recommended during the remodeling works. In addition, IAQ control and management scheme (for example, baking the inside of the building) should be taken into consideration before reopening the buildings.

The Factor Analyses of Service Quality Components in University Libraries (대학도서관 서비스 질의 구성요인 분석)

  • Paik, Hang-Ki;Lee, Eun-Chul
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.34 no.4
    • /
    • pp.5-26
    • /
    • 2000
  • The purpose of this study was to measure performance of university libraries, especially investigating the components of service quality and their relationship to the customer satisfaction. The result of the study was summarized as follows: First, the factors on satisfaction of library service revealed 12 factors such as access of information, quality of employees, suitable collections, issues related to civil petitions, equipments and facilities, timeliness, operating hours, use of information technology, library user education, reference service, public relation and individual service. Second, the factors of library service on customer satisfaction showed the following primary factors: suitable collections, issues related to civil petitions, access of information, equipments and facilities, timeliness, public relation, reference service, operating hours, and individual service. Third, the components of library service on customwe satisfaction showed the following primary components: availability, the number of books and journals, facilities of air conditioning, public relation, usefulness of retrieval system, waiting time for Internet use, operating hour, speed of repairs, receipt of civil petitions, use of non-book materials.

  • PDF

The Study On the Distribution of Indoor Concentration of Microorganism in Commercial Building (다중이용시설의 실내공기 미생물 오염실태에 관한 연구)

  • Park Kyung-Su;Choi Sang-Gon;Hong Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.620-626
    • /
    • 2006
  • Recently, indoor air quality (IAQ) is one of the greatest problems in our modern societies. Although research for IAQ is made rapid progress but IAQ problems concerning in door microorganism contamination is required to be studied still more. So we have investigated the indoor microorganism concentration of a variety of department store, subway station, underground shopping center, kindergartens, library where people complain about the in-door air quality. The experiment on microorganism concentration of indoor air was carried out and the average of total microorganisms was measured. Comparing the experimental results with existing foreign criterion, the experimental results show that the ministry of environment recommendation microorganism concentration value ($800 CFU/m^3$) is in need of revision in the near future.

Development of Real time Air Quality Prediction System

  • Oh, Jai-Ho;Kim, Tae-Kook;Park, Hung-Mok;Kim, Young-Tae
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.73-78
    • /
    • 2003
  • In this research, we implement Realtime Air Diffusion Prediction System which is a parallel Fortran model running on distributed-memory parallel computers. The system is designed for air diffusion simulations with four-dimensional data assimilation. For regional air quality forecasting a series of dynamic downscaling technique is adopted using the NCAR/Penn. State MM5 model which is an atmospheric model. The realtime initial data have been provided daily from the KMA (Korean Meteorological Administration) global spectral model output. It takes huge resources of computation to get 24 hour air quality forecast with this four step dynamic downscaling (27km, 9km, 3km, and lkm). Parallel implementation of the realtime system is imperative to achieve increased throughput since the realtime system have to be performed which correct timing behavior and the sequential code requires a large amount of CPU time for typical simulations. The parallel system uses MPI (Message Passing Interface), a standard library to support high-level routines for message passing. We validate the parallel model by comparing it with the sequential model. For realtime running, we implement a cluster computer which is a distributed-memory parallel computer that links high-performance PCs with high-speed interconnection networks. We use 32 2-CPU nodes and a Myrinet network for the cluster. Since cluster computers more cost effective than conventional distributed parallel computers, we can build a dedicated realtime computer. The system also includes web based Gill (Graphic User Interface) for convenient system management and performance monitoring so that end-users can restart the system easily when the system faults. Performance of the parallel model is analyzed by comparing its execution time with the sequential model, and by calculating communication overhead and load imbalance, which are common problems in parallel processing. Performance analysis is carried out on our cluster which has 32 2-CPU nodes.

  • PDF

Birth cohort effects on maternal and child environmental health: a systematic review (모아의 환경적 건강에 대한 출산 코호트 효과: 체계적 고찰)

  • Chae, JungMi;Kim, Hyun Kyoung
    • Women's Health Nursing
    • /
    • v.27 no.1
    • /
    • pp.27-39
    • /
    • 2021
  • Purpose: This study aimed to review recent findings from birth cohort studies on maternal and child environmental health. Methods: Birth cohort studies regarding environmental health outcomes for mothers and their children were investigated through a systematic review. A literature search was conducted in PubMed, CINAHL, the Cochrane Library, Embase, and RISS to identify published studies using the keywords using a combination of the following keywords: maternal exposure, environmental exposure, health, cohort, and birth cohort. Articles were searched and a quality appraisal using the Newcastle-Ottawa Scale for cohort studies was done. Results: A review of the 14 selected studies revealed that prenatal and early life exposure to environmental pollutants had negative impacts on physical, cognitive, and behavioral development among mothers and children up to 12 years later. Environmental pollutants included endocrine disruptors, air pollution (e.g., particulate matter), and heavy metals. Conclusion: This systematic review demonstrated that exposure to environmental pollutants negatively influences maternal and children's environmental health outcomes from pregnancy to the early years of life. Therefore, maternal health care professionals should take steps to reduce mothers' and children's exposure to environmental pollutants.

The Distribution Characteristics of Carbon Dioxide in Indoor School Spaces (교육시설 실내공간의 이산화탄소 농도분포 특성 연구)

  • Cho, Young-Min;Lee, Ji-Yun;Kwon, Soon-Bark;Park, Duck-Shin;Park, Jae-Hyoung;Cho, Ki-Chul
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.117-125
    • /
    • 2011
  • There are many studies reporting the average carbon dioxide levels in various indoor spaces. However, there have been a few studies showing how carbon dioxide concentration varied at many measurement points in one indoor space. In this study, the changes of indoor carbon dioxide concentration at classroom, library, and kindergarten were reported to find its carbon dioxide distribution change at various locations and altitudes. The maximum carbon dioxide concentration of the 3 sites were measured as 2,684, 2,295, and 1,526 ppm, respectively. These values exceeded the guideline concentration of 1,000 ppm for public places. The concentration of carbon dioxide was higher at upper area than lower area, and this is probably due to the rise of warm breathing air generated from students. In the upper area, the carbon dioxide concentration was higher at center area than four corners. However, in the lower area, the carbon dioxide concentration was higher at four corners than center area. Therefore, it could be concluded that the center of upper area is the best place for the installation of ventilation or carbon dioxide removal system.

Making Primary Policies for Reducing Particulate Matter (미세먼지 저감을 위한 정책 선정 연구)

  • Kim, Bong Gyun;Lee, Won Sang;Jo, Hye In;Lee, Bong Gyou
    • The Journal of Society for e-Business Studies
    • /
    • v.25 no.1
    • /
    • pp.109-121
    • /
    • 2020
  • The purpose of this study is to find out primary policies for reducing PM(particulate matter) as well as for improving the quality of life. Serious particulate matters cause to diverse healthcare and economy problems including business transactions. Unfortunately, until recently there are very few researches regarding the decision-making process for particulate matter policies. This study has applied the AHP(Analytic Hierarchy Process) method to develop cooperative policy making processes. The upper layer of this hierarchy analysis consists of four parts, i.e., transportation, production facility, living environment, and urban planning management. And each upper layer parts has their own three policies. 25 experts including policy-makers, academic researchers and industrial specialists have decided the primary policies and directions. The most significant PM policy is the mandatory reduction of air pollution and suspension of factory operation in the production industry. The results of this study can lead to guidelines for making environmental policies.