• 제목/요약/키워드: Unit-to-unit

검색결과 25,897건 처리시간 0.053초

선형 Model에 의한 소류역에 있어서의 무차원 단위도 유도에 관한 연구 (A study on the derivation of Dimensionless Unit Hydrographs by the Linear model in the small watersheds)

  • 이순혁;한중석
    • 한국농공학회지
    • /
    • 제23권3호
    • /
    • pp.78-87
    • /
    • 1981
  • This study was attempted to get dimensionless unit hydrograph by linear model which can be used to the estimation of flood for the development of Agricultural water resources and laid emphasis on the application of dimensionless unit hydrographs for the ungaged watersheds by applying linear model. The results summarized through this study are as follows. 1.Peak discharge is found to be Qp= CAR (C =0. 895A-o.145) having high significance between peak discharge, Qp and effective rainfall, R within the range of small watershed area, 84 to 470km2. consequently, linearity was acknowledged between rainfall and runoff. Reasonability is confirmed for the derivation of dimensionless unit hydrograph by linear model. 2.Through mathematical analysis, formula for the derivation of dimensionless unit hydrograph was derived. qp--p=(tp--t)n-1[e-(n-1)](tp--t-1) 3.Moment method was used for the evaluation of storage constant, K and shape parameter, n for the derivation of dimensionless unit hydrograph. Storage constant, K is more closely related with the such watershed characteristics as length of main stream and slopes. On the other hand, the shape parameter, n was derived with such watershed characteristics as watershed area, river length, centroid distance of the basin and slopes. 4.Time to peak discharge, Tp could be expressed as Tp=1. 25 (√s/L)0.76 having a high significance. 5.Dimensionless unit hydrographs by linear model stood more closely to the observe dimensionless unit hydrographs On the contrary, dimensionless unit hydrographs by S.C. S. method has much difference in comparison with linear model at the falling limb of hydrographs. 6.Relative errors in the q/qp at the point of 0.8 and 1.2 for the dimensionles ratio by linear model and S. C. S. method showed to be 2.41, 1.57 and 4.0, 3.19 percent respectively to the q/qp of observed dimensionless unit hydrographs. 7.Derivation of dimensionless unit hydrograph by linear model can be accomplished by linking the two empirical formulars for storage constant, K, and shape parameter, n with derivation formular for dimensionless unit hydrograph for the ungaged small watersheds.

  • PDF

ECO2 프로그램을 이용한 공동주택의 단위세대 평면 형태에 따른 에너지 효율 평가 (The Influence of Unit Plan Shapes to the Energy Efficiency of Collective Housing Simulated by ECO2 Software)

  • 김창성
    • KIEAE Journal
    • /
    • 제15권5호
    • /
    • pp.89-94
    • /
    • 2015
  • Purpose: Various policies to reduce the energy consumption have been carried out to save Earth environment against global warming and environmental pollution in many countries. Energy consumption of buildings in Korea has reached 24% of total energy consumption, and energy consumption of apartment has been continuously increasing. Therefore, Korea government has executed building energy efficiency rating certification system to control energy consumption of buildings. Method: This study was conducted to evaluate the energy performance of apartment unit plans according to the increasement of front width of unit plans, and tried to present the basic data to design more energy conscious unit plans for apartments. For the study, three shapes of unit plans -the 2Bay, 3Bay and 4bay unit- were selected for imput models. They were simulated using ECO2 software to assess building energy efficiency rating certification in Korea. Result: According to the results, in cases that balcony windows were not installed, the primary energy consumption of the 3Bay and 4Bay units were less than 2Bay unit, respectively, 0.1% and 2,5%. The primary energy consumption of the 3Bay and 4Bay units, in cases that balcony windows were installed, was less than 2Bay unit, respectively, 1.7% and 3.2%.

A Unit Touch Gesture Model of Performance Time Prediction for Mobile Devices

  • Kim, Damee;Myung, Rohae
    • 대한인간공학회지
    • /
    • 제35권4호
    • /
    • pp.277-291
    • /
    • 2016
  • Objective: The aim of this study is to propose a unit touch gesture model, which would be useful to predict the performance time on mobile devices. Background: When estimating usability based on Model-based Evaluation (MBE) in interfaces, the GOMS model measured 'operators' to predict the execution time in the desktop environment. Therefore, this study used the concept of operator in GOMS for touch gestures. Since the touch gestures are comprised of possible unit touch gestures, these unit touch gestures can predict to performance time with unit touch gestures on mobile devices. Method: In order to extract unit touch gestures, manual movements of subjects were recorded in the 120 fps with pixel coordinates. Touch gestures are classified with 'out of range', 'registration', 'continuation' and 'termination' of gesture. Results: As a results, six unit touch gestures were extracted, which are hold down (H), Release (R), Slip (S), Curved-stroke (Cs), Path-stroke (Ps) and Out of range (Or). The movement time predicted by the unit touch gesture model is not significantly different from the participants' execution time. The measured six unit touch gestures can predict movement time of undefined touch gestures like user-defined gestures. Conclusion: In conclusion, touch gestures could be subdivided into six unit touch gestures. Six unit touch gestures can explain almost all the current touch gestures including user-defined gestures. So, this model provided in this study has a high predictive power. The model presented in the study could be utilized to predict the performance time of touch gestures. Application: The unit touch gestures could be simply added up to predict the performance time without measuring the performance time of a new gesture.

원개발자 부재에 따른 원시코드 기반의 단위테스트 노력 분석 (Effort Analysis of Unit Testing Conducted by Non-Developer of Source Code)

  • 윤회진
    • 한국IT서비스학회지
    • /
    • 제11권4호
    • /
    • pp.251-262
    • /
    • 2012
  • Unit testing is one of the test levels, which tests an individual unit or a group of related units. Recently, in Agile Development or Safety-critical System Development, the unit testing plays an important role for the qualities. According to the definition of unit testing, it is supposed to be done by the developers of units. That is because test models for the unit testing refers to the structure of units, and others but its original developers hardly can understand the structures. However, in practice, unit testing is often asked to be done without the original developers. For example, it is when faults are revealed in customer sites and the development team does not exit any more. In this case, instead of original developers, other developers or test engineers take a product and test it. The unit testing done by a non-developer, who is not the original developer, would cause some difficulties or cause more cost. In this paper, we tests an open source, JTopas, as a non-developer, with building test models, implementing test codes, and executing test cases. To fit this experiment to practical testing situations, we designed it based on the practices of unit testing, which were surveyed through SPIN(Software Process Improvement Network). This paper analyzes which part of unit testing done by non-developers needs more effort compared to the unit testing done by original developers. And it concludes that Agile Development contributes on reducing the extra effort caused by non-developers, since it implements test codes first before developing source code. That means all the units have already included their own tests code when they are released.

분양가 자율화이후 공동주택 단위평면의 변화경향에 관한 연구 (A Study of Transformation tendency of an Apartment Unit Plan after The Enforcement of Price Deregulation)

  • 고영석;권영;김용성
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.74-77
    • /
    • 2003
  • After the Enforcement of Price Deregulation of Apartment, Apartment house get down to originality goods, The Housing Market have reorganized the nucleus by a user, have demanding the development for discriminative unit plan. The purpose of this study is that before and after the Price Decontrol of Apartment take part a variety of unit plan, search for transformation factor and analyze into the tendency of the distinction plan of Housing Goods. Before and after the Price Decontrol of Apartment, Apartment unit have analyzed from 85 $m^2$ till 152 $m^2$ private area; ten corporations of civil construction' unit in Seoul and The national capital region supply apartment, will supply apartment. For selected examples, first, unit plan is normalized from the ratio of front to side wall, bay, a Room' organization and a kind of Room, number, and for examples of unit plan of apartment, the examples were analyzed with respect to change of a Room' organization and the number of a room and the ratio of front wall to side wall for item investigated. Finally, I search out course of transformation tendency of an apartment unit plan after Enforcement of Price Deregulation and analyzed a factor. The results of the study are follows, after Enforcement of Price Deregulation, unit plan of apartment lead to change lay out, to secure each family's privacy, to secure feeling for open hearted, tendency of flexibility.

  • PDF

시판 새우젓의 이화학적 특성 (Physicochemical Properties of Commercial Salrt-Fermented Shrimp)

  • 황종현;김진만
    • 한국식품영양과학회지
    • /
    • 제30권4호
    • /
    • pp.760-763
    • /
    • 2001
  • 시판되는 새우젓의 새로운 기능성 지표를 제시하고자 단백분해효소의 활성 및 키토산 분해활성 등을 측정하였다. 시판 되는 새우젓의 염도를 측정한 결과. 29.8~48.3%로 제품에 따라 최대 19% 정도의 염도 차이를 보였다. 총질소량은 3510.5 ~7314.1 mg/100g 으로 A시료가 7314.1 mg/100 g으로 가장 높은 총질소 함량을 보인 반면 D 시료는 3510.5 mg/100 g으로 비교적 낮은 총질소 함량을 보였다. 아미노태 질소량은 321.2~723.9 mg/100g으로 총질소 함량이 가장 낮았던 D시료가 아미노태 질소 함량이 낮았다. 5개 시판 새우젓의 평균 펩타이드 길이(average peptide length: APL)는 10.1~15.0이었다. 휘발성 염기질소는 14.1~98.6mg/100g 으로 D시료에서 가장 높은 98.6mg%의 함량을 보였다. 단백질 분해효소 활성은 18~232 unit로 차이를 보이고 있으며 C번 시료의 단백질 분해 효소 활성이 232 unit로 가장 높은 효소활성을 보였다. Chitinase 활성은 14.4~171 unit의 활성을 보였으며 E번 새우젓이 171 unit로 가장 높은 효소 활성을 보였다.

  • PDF

브랜드 아파트의 단위평면 각 실의 경향분석 (Tendency of Each Space of Unit Plans for Brand Apartments)

  • 오혜경;홍이경
    • 한국실내디자인학회논문집
    • /
    • 제20권1호
    • /
    • pp.128-137
    • /
    • 2011
  • This study aims to examine each space characteristics of unit plans for brand apartments. Through construction companies' web-sites and real estate web-sites, all the apartment unit plans with $66m^2{\sim}164m^2$ unit among the brand apartments were analyzed. On the analysis of the apartment unit plans($66m^2{\sim}164m^2$) provided by top 8 construction companies from March 2004 to December 2008. The remarkable changes compared to existing apartments include an increase in the number of bays; front side allocation of bedrooms beside the main bedroom; installation of a vestibule, a dressing room, and a powder room; installation of built-in closets in bedrooms beside the main bedroom; and installation of a receipt spot on the sidewall in the balcony. Besides, as for minor opinions there were opinions of front side allocation of kitchen/dining room, back side allocation of the main bedroom, and installation of dressing room in bedrooms beside the main bedroom. Therefore, construction companies should pay attention to research result about the unit area ranges of apartment unit plans, and reflect it positively to develop apartment unit plans to satisfy consumers.

적외선 분광법을 이용한 SBR 혼합물의 미세구조 분석 (Microstructural Analysis of SBR Blends Using Infrared Spectroscopy)

  • 김여울;최성신
    • Elastomers and Composites
    • /
    • 제49권2호
    • /
    • pp.103-109
    • /
    • 2014
  • 유화중합 SBR (E-SBR)과 용액중합 SBR (S-SBR) 블렌드를 제조하여 이들의 미세구조(styrene, 1,2-unit, cis-1,4-unit, 그리고 trans-1,4-unit 함량)를 투과 방식 휴리에 변환 적외선 분광법(FTIR)을 이용하여 분석하였다. Valley-to-valley 바탕선으로 흡광도를 측정하는 방법(TV)이 객관적으로 가장 타당한 방법이나 cis-1,4-unit의 피크 세기를 정확히 측정할 수 없는 단점이 있다. cis-1,4-Unit이 포함된 4가지 미세구조에 대한 정보를 얻기 위해, 바탕선을 보정하지 않은 방법(TM)과 최대 투과도를 99%로 조정한 방법(TB)을 TV 방법과 비교하였다. TB 방법으로 구한 결과가 TM 방법으로 구한 결과보다 TV 방법으로 구한 결과와 좀 더 가깝게 나타났다. TM 방법과 TB 방법으로 구한 흡광도를 ISO/FDIS 21561:2005(E)에 제시한 계산식을 이용하여 미세구조 함량을 결정하였다. E-SBR/S-SBR 블렌드 비에 따른 styrene, 1,2-unit, 그리고 trans-1,4-unit 함량의 변화는 비교적 선형성을 보였으며, TM 방법과 TB 방법으로 얻은 결과에는 큰 차이가 없었다. cis-1,4-Unit 함량의 변화는 TM 방법과 TB 방법에 상관없이 직선성이 전혀 나타나지 않았다.

모듈러 유닛에 의한 대학 기숙사 단위 생활공간의 평면 구성에 대한 고찰 (A Study on the Plan Formation of University Dormitory's Living Unit by Modular Unit)

  • 김정헌;김진모
    • 교육시설
    • /
    • 제16권2호
    • /
    • pp.37-45
    • /
    • 2009
  • The purpose of this study is to suggest the plan formation for university dormitory's living unit by the modular unit of the pre-fabricated architecture, Pursuing this, this study conducts the investigation of present domestic situation of prefabricated construction and practices plan formation for living unit concentrating on the dweller's satisfaction by solving the problems which hitherto constructed dormitory had, especially collapse of dweller's territoriality. Consequently, this study presents the feasibility of modular unit of present prefabricated construction as a new method of dormitory's living unit construction, and suggests the pertinent plan formation for the improvement of the dweller's territoriality.

홍수 유출 수문곡선 산출에 단위유량도 적용 오차의 정도 검토 (Review on Application Tolerance of Unit Hydrograph for Calculating Flood Runoff Hydrograph)

  • 유주환;윤여진
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.346-349
    • /
    • 2010
  • In this study several unit hydrographs by rainfall storms are derived and moving averaged unit hydrograph is extracted from them based on the rainfall-runoff data in a small basin 8.5 $km^2$ wide. And peak discharges and peak times of the unit hydrographs are investigated and reviewed. And then a representative unit hydrograph of the moving averaged one is applied to the linear convolution integration for obtaining the flood discharge hydrograph and peak discharge and time of its result are researched and inspected. Variance in application of the representative unit hydrograph in a basin on assumption of linearity is appeared and this is given as a counterevidence about that the runoff response from rainfall on a basin has nonlinear characteristics. And As a result of application of derived representative unit hydrograph the errors in peak discharge and time are investigated.

  • PDF